Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of an Optical-Real Time Polarimetric Imaging System for Aerospace Applications

The design of an optical polarimetric imaging system, aimed to detect cracks or structural defects on the surface of rotating aircraft engine shafts, is presented. The experimental results have been processed by a real time wavelet denouncing system implemented by a Filed Programmable Gate Arrays (FPGA), which has been designed for this purpose. The experimental results clearly indicate that high signal-to-noise ratio signals can be obtained.

Giakos, George C.↗

Differential phase contrast X-ray imaging system and components

A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

47 OTHER INSTRUMENTATION↗

Differential phase contrast X-ray imaging system and components

A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-color pyrometry imaging system and method of operating the same

A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

42 ENGINEERING↗

Differential phase contrast X-ray imaging system and components

A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

A ground-based adaptive optics imaging telescope system attempts to improve image quality by detecting and correcting for atmospherically induced wavefront aberrations. The required control computations during each cycle will take a finite amount of time. Longer time delays result in larger values of residual wavefront error variance since the atmosphere continues to change during that time. Thus an optical processor may be well-suited for this task. This paper presents a study of the accuracy requirements in a general optical processor that will make it competitive with, or superior to, a conventional digital computer for the adaptive optics application. An optimization of the adaptive optics correction algorithm with respect to an optical processor's degree of accuracy is also briefly discussed.

Downie, John D.↗

Improved Interactive Medical-Imaging System

An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

Ross, Muriel D.↗

Peformance evaluation of a passive microwave imaging system

A test program was conducted to evaluate the passive microwave imaging system for possible application in the NASA Earth Resources Program. In addition to test data analysis, the report gives a brief description of the radiometer, its software, and the ground support equipment. The microwave image quality is adequate for remote sensing applications studies. Instrument problems are described, and suggestions are given for possible improvements and potential applications.

Mcallum, W. E.↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗

A high resolution IR/visible imaging system for the W7-X limiter

A high-resolution imaging system, consisting of megapixel mid-IR and visible cameras along the same line of sight, has been prepared for the new W7-X stellarator and was operated during Operational Period 1.1 to view one of the five inboard graphite limiters. The radial line of sight, through a large diameter (184 mm clear aperture) uncoated sapphire window, couples a direct viewing 1344 × 784 pixel FLIR SC8303HD camera. A germanium beam-splitter sends visible light to a 1024 × 1024 pixel Allied Vision Technologies Prosilica GX1050 color camera. Both achieve sub-millimeter resolution on the 161 mm wide, inertially cooled, segmented graphite tiles. The IR and visible cameras are controlled via optical fibers over full Camera Link and dual GigE Ethernet (2 Gbit/s data rates) interfaces, respectively. While they are mounted outside the cryostat at a distance of 3.2 m from the limiter, they are close to a large magnetic trim coil and require soft iron shielding. We have taken IR data at 125 Hz to 1.25 kHz frame rates and seen that surface temperature increases in excess of 350 °C, especially on leading edges or defect hot spots. The IR camera sees heat-load stripe patterns on the limiter and has been used to infer limiter power fluxes (∼1–4.5 MW/m{sup 2}), during the ECRH heating phase. IR images have also been used calorimetrically between shots to measure equilibrated bulk tile temperature, and hence tile energy inputs (in the range of 30 kJ/tile with 0.6 MW, 6 s heating pulses). Small UFO’s can be seen and tracked by the FLIR camera in some discharges. The calibrated visible color camera (100 Hz frame rate) has also been equipped with narrow band C-III and H-alpha filters, to compare with other diagnostics, and is used for absolute particle flux determination from the limiter surface. Sometimes, but not always, hot-spots in the IR are also seen to be bright in C-III light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event-Driven Random-Access-Windowing CCD Imaging System

A charge-coupled-device (CCD) based high-speed imaging system, called a realtime, event-driven (RARE) camera, is undergoing development. This camera is capable of readout from multiple subwindows [also known as regions of interest (ROIs)] within the CCD field of view. Both the sizes and the locations of the ROIs can be controlled in real time and can be changed at the camera frame rate. The predecessor of this camera was described in High-Frame-Rate CCD Camera Having Subwindow Capability (NPO- 30564) NASA Tech Briefs, Vol. 26, No. 12 (December 2002), page 26. The architecture of the prior camera requires tight coupling between camera control logic and an external host computer that provides commands for camera operation and processes pixels from the camera. This tight coupling limits the attainable frame rate and functionality of the camera. The design of the present camera loosens this coupling to increase the achievable frame rate and functionality. From a host computer perspective, the readout operation in the prior camera was defined on a per-line basis; in this camera, it is defined on a per-ROI basis. In addition, the camera includes internal timing circuitry. This combination of features enables real-time, event-driven operation for adaptive control of the camera. Hence, this camera is well suited for applications requiring autonomous control of multiple ROIs to track multiple targets moving throughout the CCD field of view. Additionally, by eliminating the need for control intervention by the host computer during the pixel readout, the present design reduces ROI-readout times to attain higher frame rates. This camera (see figure) includes an imager card consisting of a commercial CCD imager and two signal-processor chips. The imager card converts transistor/ transistor-logic (TTL)-level signals from a field programmable gate array (FPGA) controller card. These signals are transmitted to the imager card via a low-voltage differential signaling (LVDS) cable assembly. The FPGA controller card is connected to the host computer via a standard peripheral component interface (PCI).

Monacos, Steve↗

Developing a camera-based 3D momentum imaging system capable of 1 Mhits/s

A camera-based three-dimensional (3D) imaging system with a superb time-of-flight (TOF) resolution and multi-hit capability was recently developed for electron/ion imaging [Lee et al. J. Chem. Phys. 141, 221101 (2014)]. In this work, we report further improvement of the event rate of the system by adopting an event-driven camera, Tpx3Cam, for detecting the 2D positions of electrons, while a high-speed digitizer provides highly accurate (~30 ps) TOF information for each event at a rate approaching 1 Mhits/sec.

47 OTHER INSTRUMENTATION↗

Thermal surveillance of Cascade Range volcanoes using ERTS-1 multispectral scanner, aircraft imaging systems, and ground-based data communication platforms

A combination of infrared images depicting areas of thermal emission and ground calibration points have proved to be particularly useful in plotting time-dependent changes in surface temperatures and radiance and in delimiting areas of predominantly convective heat flow to the earth's surface in the Cascade Range and on Surtsey Volcano, Iceland. In an integrated experiment group using ERTS-1 multispectral scanner (MSS) and aircraft infrared imaging systems in conjunction with multiple thermistor arrays, volcano surface temperatures are relayed daily to Washington via data communication platform (DCP) transmitters and ERTS-1. ERTS-1 MSS imagery has revealed curvilinear structures at Lassen, the full extent of which have not been previously mapped. Interestingly, the major surface thermal manifestations at Lassen are aligned along these structures, particularly in the Warner Valley.

Friedman, J. D.↗

Analysis and design of a refractive virtual image system

The optical performance of a virtual image display system is evaluated. Observation of a two-element (unachromatized doublet) refractive system led to the conclusion that the major source of image degradation was lateral chromatic aberration. This conclusion was verified by computer analysis of the system. The lateral chromatic aberration is given in terms of the resolution of the phosphor dots on a standard shadow mask color cathode ray tube. Single wavelength considerations include: astigmatism, apparent image distance from the observer, binocular disparities and differences of angular magnification of the images presented to each of the observer's eyes. Where practical, these results are related to the performance of the human eye. All these techniques are applied to the previously mentioned doublet and a triplet refractive system. The triplet provides a 50-percent reduction in lateral chromatic aberration which was the design goal. Distortion was also reduced to a minimum over the field of view. The methods used in the design of the triplet are presented along with a method of relating classical aberration curves to image distance and binocular disparity.

Kahlbaum, W. M.↗

Report of Campaign 3 Imaging Systems Planning Workshop

Many mission applications for NNSA NA-10 use dynamic imaging. These include radiographic systems for hydros and focused experiments as well as smaller-scale science experiments, both present and future. Better understanding and reduced uncertainties would be possible with improved imaging systems. While each application has different specific requirements and issues where technical advances could improve the measurements, there are areas of common need where prioritized research and development could advance imaging systems for multiple applications.

47 OTHER INSTRUMENTATION↗