Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Riders’ perceptions towards transit bus electrification: Evidence from Salt Lake City, Utah

While battery electric buses (BEBs) can lead to energy savings and reduced emissions, BEB adoption is developing slowly. Although BEBs offer quieter operations, better acceleration, and no smell of diesel or gas fumes, little focus has been placed on the user’s perspective. Here, this study investigates bus riders’ preferences toward BEBs. To achieve these objectives, a survey was designed and administered to solicit riders’ typical travel behaviors and patterns as well as preferences and opinions about BEBs’ performance in terms of emissions and noise. Statistical analysis showed that several factors influence rider perceptions towards transit bus electrification that include trip purpose, attitudes towards environmental issues and environmental impacts of BEBs, and certain non-instrumental ride factors such as ride comfort and social image. A better understanding of the importance of electrification to transit riders can help transit service providers adjust their marketing decisions and their systemwide operations to accommodate preferences towards BEBs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microscopic Origin of Twist-Dependent Electron Transfer Rate in Bilayer Graphene

Using molecular simulation and continuum dielectric theory, we consider how electrochemical kinetics are modulated by the twist angle in bilayer graphene electrodes. By establishing a connection between the twist angle and the screening length of charge carriers within the electrode, we investigate how tunable metallicity modifies the statistics of the electron transfer energy gap. Constant potential molecular simulations show that the activation free energy for electron transfer increases with screening length, leading to a non-monotonic dependence on the twist angle. Here, the twist angle alters the density of states, tuning the number of thermally accessible channels for electron transfer and the reorganization energy by affecting the stability of the vertically excited state through attenuated image charge interactions. Understanding these effects allows us to express the Marcus rate of interfacial electron transfer as a function of the twist angle in a manner consistent with experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpreting nanovoids in atom probe tomography data for accurate local compositional measurements

Quantifying chemical compositions around nanovoids is a fundamental task for research and development of various materials. Atom probe tomography (APT) and scanning transmission electron microscopy (STEM) are currently the most suitable tools because of their ability to probe materials at the nanoscale. Both techniques have limitations, particularly APT, because of insufficient understanding of void imaging. Here, we employ a correlative APT and STEM approach to investigate the APT imaging process and reveal that voids can lead to either an increase or a decrease in local atomic densities in the APT reconstruction. Simulated APT experiments demonstrate the local density variations near voids are controlled by the unique ring structures as voids open and the different evaporation fields of the surrounding atoms. We provide a general approach for quantifying chemical segregations near voids within an APT dataset, in which the composition can be directly determined with a higher accuracy than STEM-based techniques.

36 MATERIALS SCIENCE↗

Soft sample deformation, damage and induced electromechanical property changes in contact- and tapping-mode atomic force microscopy

Probe-induced soft sample damage in atomic force microscopy (AFM), as well as the resulting alteration of local mechanical and electrical properties of the material are explored, specifically comparing contact-mode and intermittent-contact-mode imaging methods. In our experiments, performed on conductive polymer films, induced changes are present in contact-mode imaging while they are negligible or absent in tapping-mode imaging. Here, to understand this result, a viscoelastic parameter extraction is performed, which suggests that permanent sample deformation can readily occur for tip-sample interactions with a duration on the timescale of contact-mode interactions. Using the extracted viscoelastic parameters, a dynamic AFM simulation is conducted, which suggests that the material responds more elastically with reduced or absent sample damage in tapping-mode AFM, due to the higher rate of mechanical deformation and shorter timescales.

42 ENGINEERING↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Deep data analysis via physically constrained linear unmixing: universal framework, domain examples, and a community-wide platform

Abstract Many spectral responses in materials science, physics, and chemistry experiments can be characterized as resulting from the superposition of a number of more basic individual spectra. In this context, unmixing is defined as the problem of determining the individual spectra, given measurements of multiple spectra that are spatially resolved across samples, as well as the determination of the corresponding abundance maps indicating the local weighting of each individual spectrum. Matrix factorization is a popular linear unmixing technique that considers that the mixture model between the individual spectra and the spatial maps is linear. Here, we present a tutorial paper targeted at domain scientists to introduce linear unmixing techniques, to facilitate greater understanding of spectroscopic imaging data. We detail a matrix factorization framework that can incorporate different domain information through various parameters of the matrix factorization method. We demonstrate many domain-specific examples to explain the expressivity of the matrix factorization framework and show how the appropriate use of domain-specific constraints such as non-negativity and sum-to-one abundance result in physically meaningful spectral decompositions that are more readily interpretable. Our aim is not only to explain the off-the-shelf available tools, but to add additional constraints when ready-made algorithms are unavailable for the task. All examples use the scalable open source implementation from https://github.com/ramkikannan/nmflibrary that can run from small laptops to supercomputers, creating a user-wide platform for rapid dissemination and adoption across scientific disciplines.

47 OTHER INSTRUMENTATION↗

Renewal of the Advanced Photon Source.

To ensure that state-of-the-art hard x-ray tools are available for US scientists and engineers who are solving key problems in energy, environment, technology development and human health, the nation's unique high-energy x-ray source needs a major renewal of its capabilities. The Advanced Photon Source renewal program responds to key scientific needs driven by our user community. The renewal encompasses many innovations in beamlines and accelerator capabilities, each of which will transform our tools and allow new problems to be solved. In particular the APS renewal dramatically expands two compelling avenues for research. Through x-ray imaging, we can illuminate complex hierarchical structures from the molecular level to the macroscopic level, and study how they change in time and in response to stimuli. Images will facilitate understanding how proteins fit together to make living organisms, contribute to development of lighter, higher-strength alloys for fuel-efficient transportation and advance the use of biomass for alternative fuels. Hard x-rays are also especially suited to the study of real materials, under realistic conditions and in real-time. The advances proposed in this area would help develop more efficient catalysts, enhance green manufacturing, point the way to artificial light-harvesting inspired by biology and help us develop more efficient lighting. The scope of the renewal of our {approx}$1.5B facility is estimated to be {approx}$350M over five years. It is vital that the investment begin as soon as possible. The renewed APS would complement other national investments such as the National Synchrotron Light Source-II and would keep the U.S. internationally competitive.

09 BIOMASS FUELS↗

The Sizes of z ∼ 9−10 Galaxies Identified in the Brightest of Reionizing Galaxies (BoRG) Survey

Redshift z = 9–10 object selection is the effective limit of Hubble Space Telescope (HST) imaging capability, even when confirmed with Spitzer. If only a few photometry data points are available, it becomes attractive to add criteria based on their morphology in these J- and H-band images. One could do so through visual inspection, a size criterion, or alternate morphometrics. We explore a vetted sample of Brightest of Reionizing Galaxies (BoRG) z ∼ 9 and z ∼ 10 candidate galaxies and the object rejected by Morishita+ to explore the utility of a size criterion in z = 9–10 candidate selection. A stringent, point-spread function (PSF)-corrected effective radius criterion ([[Formula]]) would result in the rejection of 65%–70% of the interlopers visually rejected by Morishita et al. It may also remove up to ∼20% of bona fide brightest (L≫L{sup ∗}) z = 9 or 10 candidates from a BoRG selected sample based on the Mason et al. luminosity functions, assuming the Holwerda et al. z∼9 size–luminosity relation. We argue that including a size constraint in lieu of a visual inspection may serve in wide-field searches for these objects in, e.g., Euclid or HST archival imaging with the understanding that some brightest (L≫L{sup ∗}) candidates may be missed. The sizes of the candidates found by Morishita et al. follow the expected size distribution of z ∼ 9 for bright galaxies, consistent with the log normal in Shibuya et al. and single objects. Two candidates show high star formation surface density (Σ{sub SFR}>25M{sub ⊙} kpc{sup −2}) and all merit further investigation and follow-up observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The crustal tectonics and history of Europa: A structural, morphological, and comparative analysis

An evaluation of surface features and structures on the Galilean moon Europa is made using the available high resolution Voyager imagery, low resolution support imaging, and what understanding of ice structure and mechanical behavior science has that is applicable to the problem. A general discussion of the history of Europa studies and the fundamental global morphology is undertaken. The visible lineament and terrain patterns are described, and possible origins discussed. Observations of faulting and block rotation previously described are amplified. A comparison of Europa's structures to terrestrial sea ice and lava lake crust features is also included. Finally, an attempt is made at synthesizing a unified model for the evolution of Europa's crust is presented which is compared with models developed by others.

Schenk, P. M.↗

Local spatial frequency analysis for computer vision

A sense of vision is a prerequisite for a robot to function in an unstructured environment. However, real-world scenes contain many interacting phenomena that lead to complex images which are difficult to interpret automatically. Typical computer vision research proceeds by analyzing various effects in isolation (e.g., shading, texture, stereo, defocus), usually on images devoid of realistic complicating factors. This leads to specialized algorithms which fail on real-world images. Part of this failure is due to the dichotomy of useful representations for these phenomena. Some effects are best described in the spatial domain, while others are more naturally expressed in frequency. In order to resolve this dichotomy, we present the combined space/frequency representation which, for each point in an image, shows the spatial frequencies at that point. Within this common representation, we develop a set of simple, natural theories describing phenomena such as texture, shape, aliasing and lens parameters. We show these theories lead to algorithms for shape from texture and for dealiasing image data. The space/frequency representation should be a key aid in untangling the complex interaction of phenomena in images, allowing automatic understanding of real-world scenes.

Krumm, John↗

Velocity filtering applied to optical flow calculations

Optical flow is a method by which a stream of two-dimensional images obtained from a forward-looking passive sensor is used to map the three-dimensional volume in front of a moving vehicle. Passive ranging via optical flow is applied here to the helicopter obstacle-avoidance problem. Velocity filtering is used as a field-based method to determine range to all pixels in the initial image. The theoretical understanding and performance analysis of velocity filtering as applied to optical flow is expanded and experimental results are presented.

Barniv, Yair↗

Using KD(asterisk)P modulators for polarization measurements of the sun

Longitudinal KD(asterisk)Ps are used in ground-based solar magnetographs to eliminate seeing effects by rapidly changing their retardation characteristics. Although one of the main applications for longitudinal KD(asteriak)Ps has been their use as a variable retarder for 'imaging' applications, an understanding of their limitations is important when developing scientific instruments that make very accurate polarization measurements. This paper discusses some of the problems associated with the use of these devices in the Marshall Space Flight Center (MSFC) vector magnetograph, including temperature, field of view errors, and electrical characteristics.

West, E. A.↗

A high-resolution radio image of a young supernova

A VLBI radio images of the bright supernova 1986J, which occurred in the galaxy NGC891 at a distance of about 12 Mpc, is presented. No detailed image of any supernova or remnant has been obtained before so soon after the explosion. The image shows a shell of emission with jetlike protrusions. Analysis of the images should advance understanding of the dynamics of the expanding debris, the dissipation of energy into the surrounding circumstellar medium, and the evolution of the supernova into the remnant.

Bartel, N.↗

Status of automatic guidance systems for rotorcraft in low altitude flight

Rotorcraft operating in high-threat environments fly close to the earth's surface to utilize surrounding terrain, vegetation, or man-made objects to minimize the risk of being detected by an enemy. The piloting of the rotorcraft is at best a very demanding task and the pilots need help from on-board automation tools in order to devote more time to mission-related activities. The Automated Nap-of-the-Earth (NOE) Flight Program is a cooperative NASA/Army program aimed at the development of technologies for enhancing piloted low-altitude/NOE flight path management and control through computer and sensor aiding. The long-term objective is to work towards achieving automation for aiding the pilot in NOE flight with a flight demonstration of resulting computer/sensor aiding concepts at an established course. The technology for pilot-centered NOE automation is not currently available. Success in automating NOE functions will depend on major breakthroughs in real-time flight path planning algorithms, effective methods for the pilot to interface to the automatic modes, understanding of visual images, sensor data processing/fusion, and sensor development. Our approach to developing the technologies required to solve this problem consist of the following phases: (1) algorithm development, (2) laboratory evaluation, (3) piloted ground simulation, and (4) evaluation in flight. An overview of the research in this area at NASA Ames Research Center is given.

Sridhar, Banavar↗

The use of interactive computer vision and robot hand controllers for enhancing manufacturing safety

Current available robotic systems provide limited support for CAD-based model-driven visualization, sensing algorithm development and integration, and automated graphical planning systems. This paper describes ongoing work which provides the functionality necessary to apply advanced robotics to automated manufacturing and assembly operations. An interface has been built which incorporates 6-DOF tactile manipulation, displays for three dimensional graphical models, and automated tracking functions which depend on automated machine vision. A set of tools for single and multiple focal plane sensor image processing and understanding has been demonstrated which utilizes object recognition models. The resulting tool will enable sensing and planning from computationally simple graphical objects. A synergistic interplay between human and operator vision is created from programmable feedback received from the controller. This approach can be used as the basis for implementing enhanced safety in automated robotics manufacturing, assembly, repair and inspection tasks in both ground and space applications. Thus, an interactive capability has been developed to match the modeled environment to the real task environment for safe and predictable task execution.

Marzwell, Neville I.↗

Seeing the Invisible with the IMAGE Mission

The Global Positioning System, communication, power transmission, and oil pipelines are only a few of the technologies upon which we depend in research and in everyday life. Each is at risk from invisible storms in near-Earth space. The astrophysical plasmas near our planet store and deliver vast amounts of energy from the Sun in the form of high energy particles, electric currents, and heating of the upper atmosphere. This natural plasma environment is the only one routinely measured in situ over the last 40 years and until recently one of the few we haven't been able to see. Much like atmospheric weather satellites brought global context to that field many decades ago, the IMAGE Mission is now revealing a global context for space weather. The contributions being made by the IMAGE Mission to understanding space weather will be presented along with a brief overview of this dynamic environment. Special emphasis will be placed on research involving the plasmasphere, a toroidal region of relatively dense, cold plasma surrounding the Earth that plays a key role in energy and mass transport through near-Earth space.

Gallagher, D. L.↗

The Geospace Dynamics Observatory; a Mission of Discovery for Geospace

A few examples of potential advances include: 1. Unparalleled advances in the connection of the upper atmosphere to the Sun. In the aurora and lower latitudes, extending the duration of uninterrupted images would advance understanding of the transfer of energy from the Sun to the upper atmosphere and the response of the space environment. 2. Advances in the influence of waves and tides on the upper atmosphere. Increasing both the signal to noise and the duration ofthe observations would reveal contributions that are not identifiable using other approaches. 3. The ability to probe the mechanisms that control the evolution of planetary atmospheres. The vantage point provided by this mission allows the flux of hydrogen (which is tied to the escape of water from a planet) to be mapped globally. It also allows unique observations of changes in the atmospheric structure and their causes.

Spann, James↗