Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image system design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Software for Simulating Remote Sensing Systems

The Application Research Toolbox (ART) is a collection of computer programs that implement algorithms and mathematical models for simulating remote sensing systems. The ART is intended to be especially useful for performing design-tradeoff studies and statistical analyses to support the rational development of design requirements for multispectral imaging systems. Among other things, the ART affords a capability to synthesize coarser-spatial-resolution image-data sets from finer-spatial-resolution data sets and multispectral-image-data products from hyperspectral-image-data products. The ART also provides for synthesis of image-degradation effects, including point-spread functions, misregistration of spectral images, and noise. The ART can utilize real or synthetic data sets, along with sensor specifications, to create simulated data sets. In one example of a typical application, simulated data pertaining to an existing multispectral sensor system are used to verify the data collected by the system in operation. In the case of a proposed sensor system, the simulated data can be used to conduct trade studies and statistical analyses to ensure that the sensor system will satisfy the requirements of potential scientific, academic, and commercial user communities.

Zanoni, Vicki↗

Software for Simulating Remote Sensing Systems

The Application Research Toolbox (ART) is a collection of computer programs that implement algorithms and mathematical models for simulating remote sensing systems. The ART is intended to be especially useful for performing design-tradeoff studies and statistical analyses to support the rational development of design requirements for multispectral imaging systems. Among other things, the ART affords a capability to synthesize coarser-spatial-resolution image-data sets from finer-spatial-resolution data sets and multispectral-image-data products from hyperspectral-image-data products. The ART also provides for synthesis of image-degradation effects, including point-spread functions, misregistration of spectral images, and noise. The ART can utilize real or synthetic data sets, along with sensor specifications, to create simulated data sets. In one example of a typical application, simulated data pertaining to an existing multispectral sensor system are used to verify the data collected by the system in operation. In the case of a proposed sensor system, the simulated data can be used to conduct trade studies and statistical analyses to ensure that the sensor system will satisfy the requirements of potential scientific, academic, and commercial user communities.

Vicki Zanoni↗

Simulating Remote Sensing Systems

The Application Research Toolbox (ART) is a collection of computer programs that implement algorithms and mathematical models for simulating remote sensing systems. The ART is intended to be especially useful for performing design-tradeoff studies and statistical analyses to support the rational development of design requirements for multispectral imaging systems. Among other things, the ART affords a capability to synthesize coarser-spatial-resolution image-data products. The ART also provides for simulations of image-degradation effects, including point-spread functions, misregistration of spectral images, and noise. The ART can utilize real or synthetic data sets, along with sensor specifications, to create simulated data sets. In one example of a particular application, simulated imagery of a coarse resolution system was created using high-resolution imagery from another system in order to perform a radiometric cross-comparison. In the case of a proposed sensor system, the simulated data can be used to conduct trade studies and statistical analyses to ensure that the sensor system will satisfy the requirements of potential scientific, academic, and commercial user communities.

Zanoni, Vicki↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Rapid and noncontact photoacoustic tomography imaging system using an interferometer with high-speed phase modulation technique

We designed, fabricated, and tested a rapid and noncontact photoacoustic tomography (PAT) imaging system using a low-coherence interferometer with high-speed phase modulation technique. Such a rapid and noncontact probing system can greatly decrease the time of imaging. The proposed PAT imaging system is experimentally verified by capturing images of a simulated tissue sample and the blood vessels within the ear flap of a mouse (pinna) in vivo. The axial and lateral resolutions of the system are evaluated at 45 and ∼15 μm, respectively. The imaging depth of the system is 1 mm in a special phantom. Our results show that the proposed system opens a promising way to realize noncontact, real-time PAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apple Image Processing Educator

A software system design is proposed and demonstrated with pilot-project software. The system permits the Apple II microcomputer to be used for personalized computer-assisted instruction in the digital image processing of LANDSAT images. The programs provide data input, menu selection, graphic and hard-copy displays, and both general and detailed instructions. The pilot-project results are considered to be successful indicators of the capabilities and limits of microcomputers for digital image processing education.

Gunther, F. J.↗

Pupil Alignment Considerations for Large, Deployable Space Telescopes

For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

Bos, Brent J.↗

Aperture Tolerances for Neutron-Imaging Systems in Inertial Confinement Fusion

Neutron imaging systems are being considered as an ignition diagnostic for the National Ignition Facility (NIF) [Hogan et al. Nucl. Fusion 41, 567 (2001)]. Given the importance of these systems, a neutron-imaging design tool is being used to quantify the effects of aperture fabrication and alignment tolerances on reconstructed neutron images for inertial confinement fusion. The simulations indicate that alignment tolerances of more than 1 mrad would introduce measurable features in a reconstructed image for both pinholes and penumbral aperture systems. These simulations further show that penumbral apertures are several times less sensitive to fabrication errors than pinhole apertures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility test of a solid state spin-scan photo-imaging system

The feasibility of using a solid-state photo-imaging system to obtain resolution imagery from a Pioneer-type spinning spacecraft in future exploratory missions to the outer planets is discussed. Evaluation of the photo-imaging system performance, based on electrical video signal analysis recorded on magnetic tape, shows that the signal-to-noise (S/N) ratios obtained at low spatial frequencies exceed the anticipated performance and that measured modulation transfer functions exhibited some degradation in comparison with the estimated values, primarily owing to the difficulty in obtaining a precise focus of the optical system in the laboratory with the test patterns in close proximity to the objective lens. A preliminary flight model design of the photo-imaging system is developed based on the use of currently available phototransistor arrays. Image quality estimates that will be obtained are presented in terms of S/N ratios and spatial resolution for the various planets and satellites. Parametric design tradeoffs are also defined.

Laverty, N. P.↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

The Eagle ALDRIS (Agile Low-Does Radiographic Imaging System)

The overall project was to design a mobile (truck-based) cargo scanning system that can be deployed at different stations according to need. In addition, the project would optimize the use of the electron beam thereby reducing the overall radiation produced and to help make the radiation shielding lighter. The SLAC work for this project done through this CRADA was to design the beam-line from the output of the alpha-magnet at the end of the Varian linac to the photon production target. The beam is required to hit the photon production target at the same point but with a range of vertical angles from +/- 25°. In addition, the scope of work by SLAC was to provide an alternate design for the linac based on new linac and RF source technology developed at SLAC.

43 PARTICLE ACCELERATORS↗

Simulation Of Satellite Imagery From Aerial Imagery

High-resolution-image data convolved with point-spread function. Report describes use of higher-resolution-image data from aerial photographs or electronic scans of ground to simulate lower resolution images obtained if same area of ground viewed from imaging system in orbit. Simulation technique helpful in analysis of data received from operating satellites and in design of future satellite-borne imaging systems.

Hlavka, Christine A.↗

Remote driving with reduced bandwidth communication

Oak Ridge National Laboratory has developed a real-time video transmission system for low bandwidth remote operations. The system supports both continuous transmission of video for remote driving and progressive transmission of still images. Inherent in the system design is a spatiotemporal limitation to the effects of channel errors. The average data rate of the system is 64,000 bits/s, a compression of approximately 1000:1 for the black and white National Television Standard Code video. The image quality of the transmissions is maintained at a level that supports teleoperation of a high mobility multipurpose wheeled vehicle at speeds up to 15 mph on a moguled dirt track. Video compression is achieved by using Laplacian image pyramids and a combination of classical techniques. Certain subbands of the image pyramid are transmitted by using interframe differencing with a periodic refresh to aid in bandwidth reduction. Images are also foveated to concentrate image detail in a steerable region. The system supports dynamic video quality adjustments between frame rate, image detail, and foveation rate. A typical configuration for the system used during driving has a frame rate of 4 Hz, a compression per frame of 125:1, and a resulting latency of less than 1s.

Depiero, Frederick W.↗