Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Multiplexed Fluorescent Calcium and NFAT Reporter Gene Assay to Identify GPCR Agonists

Intracellular calcium response and resulting calcium signaling to an agonist-GPCR interaction are important for the measurement of compound activity in the GPCR drug development. The increase in cytosol calcium concentration can be measured by the fluorescent calcium indicator dye such as Fluo-4 in a quick assay (in 3-5 minutes) using the fluorescence imaging plate reader. The calcium signaling through the transcription factors such as NFAT that induces gene expression can be measured by the reporter gene assay that links to the expression of reporter enzyme such as the betalactamase that requires 5-hour incubation. We have evaluated a multiplexed assay that sequentially measures the calcium response to a GPCR agonist in a rapid fluorescent calcium dye assay, followed by a NFAT beta-lactamase assay, and compared them in the single assay format. We found that the agonist activity determined in the multiplexed assay were comparable with these determined in the single assay format and the Z’ factors were all >0.5. Five active compounds were identified that were active in both calcium dye assay and beta-lactamase assay. Therefore, our results demonstrated the utility of this multiplexed calcium assay for screening of GPCR compounds that can cross validate the primary hits and help to eliminate the false positive compounds.

59 BASIC BIOLOGICAL SCIENCES↗

The tidal filament of NGC 4660

NGC 4660, in the Virgo cluster, is a well-studied elliptical galaxy which has a strong disk component (D/T approximately 0.2–0.3). The central regions, including the disk component, have stellar populations approximately 12–13 Gyr in age, based on SAURON studies. However, we report the discovery of a long, narrow tidal filament associated with the galaxy, as seen in deep co-added Schmidt plate images and deep CCD frames, implying that the galaxy has undergone a tidal interaction and merger within the last few Gyr. The relative narrowness of the filament implies a wet merger with at least one spiral galaxy involved, but the current state of the system shows little evidence of such. However, a two-component photometric fit using GALFIT shows much bluer B−V colors for the disk component than for the elliptical component, which may represent a residual trace of enhanced star formation in the disk caused by the interaction 1–2 Gyr ago. There are brighter concentrations within the filament that resemble tidal dwarf galaxies, although they are at least 40 times fainter. These concentrations may represent faint, evolved versions of those galaxies. A previously detected stripped satellite galaxy south of the nucleus seen in our residual image may imply that the filament is a tidal stream produced by perigalactic passages of this satellite.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Basic research and data analysis for the National Geodetic Satellite Program

Investigations of triangulation nets and scaling are reported. Adjustment of the BC-4 worldwide geometric satellite triangulation net is described, along with procedures for correcting type II data and the contents of magnetic tapes containing data from the Pageos network. Computational steps for the further reduction of partially reduced satellite image plate coordinates are outlined. The problem of improving existing triangulation systems by means of satellite super-control points was studied. The SAO-69 geometric solution was scaled with C-band radar data, resulting in SAO and C-band adjustment compatible with one another in the Western Hemisphere. The North America solution NA-6, obtained from GEOS 1 data, was readjusted with new heights as constraints on all 30 optical stations and is referred to as the NA-8 solution.

Source record↗

Rocket instrument for far-UV spectrophotometry of faint astronomical objects

A sensitive sounding rocket instrument for moderate (about 10-A) resolution far-UV (1160-1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employes a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

Hartig, G. F.↗

Generation Mechanisms UV and X-ray Emissions During SL9 Impact

The purpose of this grant was to study the ultraviolet and X-ray emissions associated with the impact of comet Shoemaker-Levy 9 with Jupiter. The University of Michigan task was primarily focused on theoretical calculations. The NAGW-4788 subtask was to be largely devoted to determining the constraints placed by the X-ray observations on the physical mechanisms responsible for the generation of the X-rays. Author summarized below the ROSAT observations and suggest a physical mechanism that can plausibly account for the observed emissions. It is hoped that the full set of activities can be completed at a later date. Further analysis of the ROSAT data acquired at the time of the impact was necessary to define the observational constraints on the magnetospheric-ionospheric processes involved in the excitation of the X-ray emissions associated with the fragment impacts. This analysis centered around improvements in the pointing accuracy and improvements in the timing information. Additional pointing information was made possible by the identification of the optical counterparts to the X-ray sources in the ROSAT field-of-view. Due to the large number of worldwide observers of the impacts, a serendipitous visible plate image from an observer in Venezuela provided a very accurate location of the present position of the X-ray source, virtually eliminating pointing errors in the data. Once refined, the pointing indicated that the two observed X-ray brightenings that were highly correlated in time with the K and P2 events were brightenings of the X-ray aurora (as identified in images prior to the impact).Appendix A "ROSAT observations of X-ray emissions from Jupiter during the impact of comet Shoemaker-Levy 9' also included.

Waite, J. Hunter, Jr.↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Crystallization and preliminary X-ray diffraction analysis of restriction endonuclease EcoRII

Crystals of the restriction endonuclease EcoRII have been obtained by the vapor-diffusion technique in the presence of ammonium sulfate or polyethylene glycol. The best crystals were grown with ammonium sulfate as a precipitant. Crystals with dimensions of up to 0.6 x 0. 6 x 0.6 mm have been observed. The crystals diffract to about 4.0 A resolution at a cryo-temperature of 100 K using a rotating-anode X-ray source and a Rigaku R-AXIS IV imaging-plate detector. The space group has been determined to be either I23 or I2(1)3, with unit-cell parameters a = b = c = 160.3 A, alpha = beta = gamma = 90 degrees. The crystal asymmetric unit contains two protein molecules, and self-rotation function analysis shows a pseudo-twofold symmetry relating the two monomers. Attempts to improve the resolution of crystal diffraction and to search for heavy-atom derivatives are under way.

Deoxyribonucleases, Type II Site-Specific/chemistr↗

Beamline Electrostatic Levitator (BESL) for in-situ High Energy K-Ray Diffraction Studies of Levitated Solids and Liquids at High Temperature

Determinations of the phase formation sequence, the crystal structures and the thermodynamic properties of materials at high temperatures are difficult because of contamination from the sample container and environment. Containerless processing techniques, such as electrostatic (ESL), electromagnetic (EML), aerodynamic, and acoustic levitation, are most suitable these studies. An adaptation of ESL for in-situ structural studies of a wide range of materials, including metals, semiconductors, insulators using high energy (125 keV) synchrotron x-rays is described here. This beamline ESL (BESL) allows the in-situ determination of the atomic structures of equilibrium solid and liquid phases, including undercooled liquids, as well as real-time studies of solid-solid and liquid-solid phase transformations. The use of image plate (MAR345) or GE-Angio detectors enables fast (30 ms - 1s) acquisition of complete diffraction patterns over a wide q-range (4 - 140/mm). The wide temperature range (300 - 2500 K), containerless processing under high vacuum (10(exp -7) - 10(exp -8) torr), and fast data acquisition, make BESL particularly suitable for phase diagram studies of high temperature materials. An additional, critically important, feature of BESL is the ability to also make simultaneous measurement of a host of thermo-physical properties, including the specific heat, enthalpy of transformation, solidus and liquidus temperatures, density, viscosity, and surface tension; all on the same sample and simultaneous with the structural measurements.

Gangopadhyay, A. K.↗

Atomic Oscillator Strengths in the Vacuum Ultraviolet

We have developed techniques to measure branching fractions in the vacuum ultraviolet using diffraction grating spectroscopy and phosphor image plates as detectors. These techniques have been used to measure branching fractions in Fe II that give prominent emission lines in astrophysical objects.

Nave, Gillian↗

Thomson parabola ion energy analyzer

A new, versatile Thomson parabola ion energy (TPIE) analyzer has been designed and constructed for use at the OMEGA-EP facility. Multi-MeV ions from EP targets are transmitted through a W pinhole into a (5- or 8-kG) magnetic field and subsequently through a parallel electric field of up to 30 kV/cm. The ion drift region may have a user-selected length of 10, 50, or 80 cm. With the highest fields, 500-Me V C{sup 6+} and C{sup 5+} may be resolved. TPIE is TIM-mounted at OMEGA-EP and is qualified in all existing TIMs. The instrument runs on pressure-interlocked 15-VDC power available in EP TIM carts. It may be inserted to within several inches of the target to attain sufficient flux for a measurement. For additional flux control, the user may select a square-aperture W pinhole of 0.004-inch or 0.010-inch. The detector consists of CR-39 backed by an image plate. The fully relativistic design code and design features are discussed. Ion spectral results from first use at OMEGA-EP are expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of Recent Tritium Experiments in TPE

Tritium retention in plasma-facing components influences the design, operation, and lifetime of fusion devices such as ITER. Most of the retention studies were carried out with the use of either hydrogen or deuterium. Tritium Plasma Experiment is a unique linear plasma device that can handle radioactive fusion fuel of tritium, toxic material of beryllium, and neutron-irradiated material. A tritium depth profiling method up to mm range was developed using a tritium imaging plate and a diamond wire saw. A series of tritium experiments (T2/D2 ratio: 0.2 and 0.5 %) was performed to investigate tritium depth profiling in bulk tungsten, and the results shows that tritium is migrated into bulk tungsten up to mm range.

08 HYDROGEN↗

Stripping of H- beams by residual gas in the linac at the Los Alamos neutron science center

The linear accelerator at the Los Alamos Neutron Science Center (LANSCE) accelerates both protons and H{sup -} ions using Cockroft-Walton-type injectors, a drift-tube linac and a coupled-cavity linac. The vacuum is maintained in the range of 10{sup -6} to 10{sup -7} Torr; the residual gas in the vacuum system results in some stripping of the electrons from the H{sup -} ions resulting in beam spill and the potential for unwanted proton beams delivered to experiments. We have measured the amount of fully-stripped H{sup -} beam (protons) that end up at approximately 800 MeV in the beam switchyard at LANSCE using image plates as very sensitive detectors. We present here the motivation for the measurement, the measurement technique and results.

43 PARTICLE ACCELERATORS↗

Behavior of Tritium near Surface Region of Metals Exposed to Tritium Plasma

In order to understand behavior of tritium (T) on surface and in bulk of metals exposed to T plasma, both surface activities and depth profiles of T were periodically observed by a tritium imaging plate technique during storage in air at room temperature (RT) for over 1 year. In the T depth profiles, T localized within a depth of sub mm from the surface was clearly distinguished from T in the bulk. The former was attributed to strong trapping by some defects produced by the plasma exposure and remained quite longer during the storage, while the latter was released from the surfaces by diffusion. T surface activity measured on the plasma-exposed surface changed in a complicated way with time due to removal of T by isotopic replacement with H in ubiquitous H2O and T supply from the bulk in the course of the diffusional release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated X-Ray Reflectivity Measurements for Elliptically Curved PET Crystals

Spectroscopy provides valuable information about the temperature and density of a compressed pellet in a plasma. Elliptically curved pentaerythritol (PET) crystals are used as components for spectrometers. Their elliptical geometry gives several advantages related to spectral energy range, source focus, and spectral image compression.[1] The crystal curvature increases the spectrometer throughput but at the cost of a loss in resolution. Four different crystals are used in a spectrometer at the National Ignition Facility (NIF) target chamber at Lawrence Livermore National Laboratory (LLNL). Figure 1 shows the arrangement of the elliptical PET crystals in the snout of a NIF target diagnostic shown in Figure 2. The spectrum from the crystals is captured by four image plates located behind the crystals. A typical mandrel, the darkened section, upon which the PET crystal is glued, is shown in Figure 3, which also shows the complete ellipse. There are four elliptical segment types, each having the same major axis but a different minor axis. The crystals are 150 mm long in the diffraction direction and 25.4 mm high. Two crystals of each type were calibrated. The throughput for each spectrometer is determined by the integrated reflectivity of the PET crystal.[1] The goal of this effort was to measure the reflectivity curve of the PET curved crystal at several energies and determine the integrated reflectivity and the curve width as a function of the X-ray spectral energy and location on the ellipse where the beam strikes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Radiography Imager:Generates Synthetic Proton Radiographs

ProRad is a computer program that is used to generate synthetic images of proton (or other charged particles) radiographs. The proton radiographs arc images that arc obtained by sending energetic protons (or electrons or positrons, for example) through 11 plasma where electric and/or magnetic fields alter the particles trajectory, Dnd the variations me imaged on RC film, image plate, or equivalent

Wilks, Scott C.↗

Computed radiography system for mammography

A computed radiography system including a stimulating light source such as a laser, a photostimulable glass imaging plate (PGIP) substantially transparent to the stimulating light positioned such that the stimulating light impinges the PGIP perpendicularly thereto producing photostimulated luminescence light (PLL), a light collector having a light reflecting inner surface proximate the PGIP for collecting PLL emitted from the PGIP and having a hole or slot therein for admitting stimulating light into the light collector and onto the PGIP. An optical filter in communication with the light collector for blocking stimulating light waves and passing PLL therethrough. A light detector receives PLL from the optical filter and the light collector, mechanism providing relative movement between the PGIP and the stimulating light source, and mechanism including an analog to digital converter for converting the collected and detected PLL to a diagnostic readout. The system is particularly useful in mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GLASS CERAMICS FOR HIGH RESOLUTION IMAGING

Glass-ceramic materials are being developed for use in digital mammography systems. The materials are transparent x-ray storage phosphors, which are potentially less expensive than competing materials with superior performance. The materials do not suffer from loss of resolution and increased noise due to light scattering from grain boundaries, as do the currently available polycrystalline materials. The glass ceramics are based on Eu2+ -doped fluorochlorozirconate glasses. These can be heat treated to nucleate Eudoped barium chloride nanocrystals. The glass ceramic converts ionizing radiation (typically x-rays) into stable electronhole pairs that can be read by scanning a stimulating light beam across the glass to cause photostimulated luminescence (PSL) emission. Measurements on the materials are ongoing to elucidate structure-property relationships developed as a result of introducing rare-earth ions and modifying process conditions. Image quality measurements indicate that the current material competes with state-of-the-art x-ray imaging plates. The paper presents results on structure, properties and future directions of the materials described above.

36 MATERIALS SCIENCE↗