Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗

DOE-VFP; Surface Engineered Multifunctional Zeolite Composite for Photodegradation of Per- and Polyfluoroalkyl substances (PFAS) in Aqueous Medium

Per- and Polyfluoroalkyl substances (PFAS) are widely used compounds proven to bioaccumulate and result in detrimental health effects. On October 18, 2021 the United States Environmental Pollution Agency (EPA) released a strategic roadmap to address PFAS that includes the investment in effective research that accelerates cleanup. Existing water treatment technologies for PFAS removal are based on adsorptive removal, are commonly single-use and result in pollutant-laden waste, leading to costly disposal processes. Here we proposed the development of a zeolite-TiO 2 composite for removal and degradation of PFAS. The composite is advantageous as it can be easily integrated into water treatment facilities, is multifunctional, and minimizes waste through regeneration. We studied the adsorptive capacity of zeolites 13X, 3A, 4A and 5A for an anionic PFAS surrogate, methyl orange (MO). Zeolite 3A showed the highest adsorptive capacity, followed by 4A, 5A, and 13X when incubated with 15 ppm MO for 3 hours. Depositing Au-nanospheres on the zeolites surface reduced MO adsorption for all zeolites. We also investigated the photodegradation capacity of TiO 2 , Fe 2 O 3 , Au-TiO 2 , and Au-Fe 2 O 3 , ranking their performance as TiO2 > Fe2O3 > Au-TiO 2 > Au-Fe 2 O 3 under 254 nm light in a 10 ppm MO solution. Our results highlight the favorable adsorption of small pore size zeolites for PFAS surrogates and the potential of TiO2 as a photocatalyst for PFAS degradation. We can further study and integrate the composite's components at our home institution. Other notable achievements of our VFP team includes the submission of two funding proposals, two poster presentations and one invited talk thus showcasing our progress.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EXTRACTING HUMAN RELIABILITY FINDINGS FROM HUMAN FACTORS STUDIES IN THE HUMAN SYSTEMS SIMULATION LABORATORY

Modernization of U.S. nuclear power plants (NPPs) is widespread, with most plants currently replacing and transitioning equipment, control systems, and human system interfaces (HSI)s from analog to digital displays. This conversion remedies the obsolescence of analog parts along with needs for increased intuitiveness of design, safety, and capabilities. The Human Factors and Reliability team at Idaho National Laboratory (INL) carried out twelve control room modernization studies in the newly designed Human Systems Simulation Laboratory (HSSL) over nine years. The HSSL was constructed as a testbed for evaluating human factors techniques and performance measures, HSI frameworks, and cutting-edge operational concepts in NPPs. Installing a full-scope training simulator enabled direct design and evaluation work on the same instrumentation and control (I&C) and HSIs located at U.S. plants. The subsequent addition of glass top bays afforded crews opportunities to implement operations via the simulator using full-scale representations of their home NPP. Additionally, functional HSI prototypes were created, providing an environment for operator-in-the-loop benchmark studies. The HSSL has assisted in upgrades of six commercial NPP control rooms and served as an invaluable proving ground for new NPP operations technology. Human reliability analysis (HRA) was not originally the focus of the studies; however, data relating to HRA such as type and frequency of human errors can be extracted from the studies. INL is currently extracting data from the HSSL study reports to apprise how information gathered from simulation, HSI, and other related studies can create a broad look across different data sources to help inform HRA methods.

99 GENERAL AND MISCELLANEOUS↗

Modeling Savings for ENERGY STAR Smart Home Energy Management Systems

The objective of this study was to develop a repeatable and defensible methodology to analyze the energy savings for Home Energy Management Systems (HEMS) that meets the minimum requirements for certification under ENERGY STAR ® Smart Home Energy Management System (SHEMS) Version 1. Mandatory connected loads include a smart thermostat, two smart lights, and one smart power strip or smart outlet. Control strategies must include feedback to occupants through an in-home display, user programming, occupancy sensor-based controls, and responsiveness to utility signals such as demand response programs. Several occupant behavior patterns were selected to quantify the range of energy savings potential for a HEMS with this basic functionality. A literature review was conducted to establish realistic room-by-room occupancy levels and usage patterns for connected devices. A series of event-driven hourly profiles were created, followed by adjustments based on application of HEMS control strategies to thermostats, interior lighting, and plug load schedules. EnergyPlus modeling was performed using these hourly schedules in three locations (Boston, Houston, and Phoenix) to examine climate dependence of energy savings. Total site energy savings ranged from 4.3 to 27.1 MBtu/year (7%-35%), and utility bill savings ranged from $\$$123 to $\$$670/year (6%-29%). The highest predicted savings was realized by occupants that were not energy conscious prior to HEMS installation, but highly engaged with the HEMS controls once the system was installed. The smart thermostat accounted for most of the savings, followed by the smart power strip. Smart lighting did not save a significant amount of energy in our analysis, based on an assumption that efficient LEDs with no standby power would normally be installed anyway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Geomechanical Computation Analysis Evaluating Behavior of the Fault nearby BC-4

BC-4 is an abandoned brining cavern situated in the middle of the site. Its presence poses a concern for several reasons: 1) the cavern was leached up into the caprock; 2) it is similar to BC-7, a brining cavern on the northwest corner of the dome that collapsed in 1954 and now is the home to Cavern Lake; 3) a similar collapse of BC-4 would have catastrophic consequences for the future operation of the site. There exists a previously mapped fault feature in the caprock and thought to extend into the salt dome than runs in close proximity to BC-4. There are uncertainties about the true extent of the fault, and no explicit analysis has been performed to predict the effects of the fault on BC-4 stability. Additional knowledge of the fault and its effects is becoming more crucial as an enhanced monitoring program is developed and installed.

54 ENVIRONMENTAL SCIENCES↗

Investigating the Determinants of Household Capabilities Burden During Power Outages: The Case of Winter Storm Uri

Existing research primarily uses census data to identify the vulnerability of communities to hazards. These vulnerability indices provide aggregated data and are not hazard-specific nor well-validated with post-event data. In contrast, our study uses household survey data (n=1065) to understand which Texan households suffered the greatest loss of their capabilities due to power outages and other utility service disruptions during Winter Storm Uri. Inspired by the Capabilities Approach, our measures of burden include the number of household capability types disrupted during the outages (e.g., cooking, heating, refrigeration), the severity of impact for each disrupted capability, and the additional time and financial costs of coping with these disruptions. We perform a clustering analysis, and find two distinct groups in our data, consisting of ‘lesser burden' and ‘heavier burden' households. Results indicate that the households experiencing the heaviest capabilities burden were most likely to experience longer power outages and the loss of water services. They were also more likely to have a Hispanic-Latino household member, lack access to a generator, live in a rented home, have larger households with more young children, fewer adults over 65, lower household incomes, been impacted by the COVID-19 pandemic, and more family characteristics that made life harder. We also fit a logistic regression model to assess the role of outage, household, and community characteristics in predicting differences in capabilities burden. Our results offer insights into enumerating the consequences of utility service disruptions on households, which can inform more targeted and equitable resilience strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly detection for MPC forecast in Fleet of Water Heaters

Among residential devices, water heaters consume 20% of home energy use in the United States. Water heaters possess the capability to store energy within their reservoirs, enabling the ability to decouple energy use from hot water use. This capability can be used to reduce energy usage and costs while also supporting grid services. This requires accurate forecasting of the parameters of the water heater such as upper and lower temperatures. In this study, we analyzed the performance and behavior of a water heater model used in the real-world to predict a control mechanism that is implemented in a smart residential neighborhood. The model forecasts are accurate in most cases but not all. In such scenarios, error correction of the model is necessary to further improve model predictive control accuracy. Anomaly detection is the first step of error correction. This study complements existing research by grouping time series data into two clusters one with anomalies and another without anomalies. To achieve this task, we explored and compared multiple unsupervised machine learning algorithms to perform clustering. Among these algorithms, Ward clustering has the lowest running time and identified the highest number of anomalies for the upper temperature limit. The proposed approach is tested based on the data collected in a neighborhood with 46 townhomes located in Atlanta, GA.

Lebakula, Viswadeep↗

Experimental Studies and Energy Modeling for Evaluating Performance of Various Deep Wall Retrofits

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.

Nagda, Harshil↗

Oak Ridge National Laboratory FY 2023 Site Sustainability Plan With FY 2022 Performance Data

At the close of each fiscal year, the US Department of Energy (DOE) Sustainability Performance Division (SPD) issues guidance documents and technical resource aids/tools necessary for DOE sites and national laboratories to complete sustainability reporting requirements. SPD is part of the DOE Office of Asset Management. As required by DOE Order 436.1, Departmental Sustainability, “each site will develop and commit to an annual Site Sustainability Plan (SSP) that identifies its respective contribution toward meeting the DOE’s sustainability goals.” SPD collects and compiles information reported by each site to develop an agency-wide Sustainability Report and Implementation Plan, which is used to report DOE sustainability progress to the federal government as required by all major federal agencies. DOE launched a formal Sustainability Office and annual SSP process in 2011. Each year, Oak Ridge National Laboratory (ORNL), in concert with the Office of Science (SC), provides the resources essential to fulfill its commitment to deliver a complete and accurate SSP report and quality performance data for entry into the DOE Sustainability Dashboard as managed by SPD. The performance data entered by each DOE site are then combined to disclose the progress of each DOE Program Office and are further combined to show comprehensive progress for the agency. The Office of Asset Management provides assistance to program offices in sustaining their missions, freeing up resources by reducing waste, avoiding excess expenditure on utilities, maximizing productivity, and improving the efficiency of facilities and processes. By focusing on mission needs, programs and associated DOE sites can help the agency meet its sustainability goals, as outlined in federal statutory and regulatory requirements. In FY 2022, the SSP guidance was updated to capture requirements from Executive Order (EO) 14008, Tackling the Climate Crisis at Home and Abroad, the Energy Act of 2020 (EAct 20), actions outlined in DOE’s Climate Adaptation & Resilience Plan and Sustainability Plan, and EO 14057, Catalyzing Clean Energy Industries and Jobs Through Federal Sustainability. Updates in SSP guidance help to minimize and streamline reporting while simultaneously addressing updated federal requirements. Per DOE, each SSP report should provide an overview of the site’s planned actions, as well as an overview of efforts and accomplishments during the reporting period. SPD collects and compiles information reported by each site to develop DOE’s Annual Sustainability Report, Climate Adaptation & Resilience Plan, and Annual Energy Management Report to Congress. The agency goal has been to lower the reporting burden for sites and increase and improve the consistency of information available to decision makers, allowing them to better identify projects and potential for increased efficiency, as well as to reduce waste, lower emissions, and enhance operational resilience. Sites may elect to produce a more polished publication for their leadership and stakeholders, but this step is no longer required. The ORNL SSP narrative report (this document) and the reporting of DOE SPD Sustainability Dashboard performance data is a collaborative effort of approximately 30 subject matter experts (SMEs) from ORNL facility management and research divisions. Annually, these associates come together to provide a report that can be used by DOE to demonstrate continued agency progress in energy efficiency and sustainable federal operations.

99 GENERAL AND MISCELLANEOUS↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Six Sequential Charged Particle Beams on Behavioral and Cognitive Performance in B6D2F1 Female and Male Mice

The radiation environment astronauts are exposed to in deep space includes galactic cosmic radiation (GCR) with different proportions of all naturally occurring ions. To assist NASA with assessment of risk to the brain following exposure to a mixture of ions broadly representative of the GCR, we assessed the behavioral and cognitive performance of female and male C57BL/6J × DBA2/J F1 (B6D2F1) mice two months following rapidly delivered, sequential 6 beam irradiation with protons (1 GeV, LET = 0.24 keV, 50%), 4 He ions (250 MeV/n, LET = 1.6 keV/μm, 20%), 16 O ions (250 MeV/n, LET = 25 keV/μm 7.5%), 28 Si ions (263 MeV/n, LET = 78 keV/μm, 7.5%), 48Ti ions (1 GeV/n, LET = 107 keV/μm, 7.5%), and 56 Fe ions (1 GeV/n, LET = 151 keV/μm, 7.5%) at 0, 25, 50, or 200 cGy) at 4–6 months of age. When the activity over 3 days of open field habituation was analyzed in female mice, those irradiated with 50 cGy moved less and spent less time in the center than sham-irradiated mice. Sham-irradiated female mice and those irradiated with 25 cGy showed object recognition. However, female mice exposed to 50 or 200 cGy did not show object recognition. When fear memory was assessed in passive avoidance tests, sham-irradiated mice and mice irradiated with 25 cGy showed memory retention while mice exposed to 50 or 200 cGy did not. The effects of radiation passive avoidance memory retention were not sex-dependent. There was no effect of radiation on depressive-like behavior in the forced swim test. There was a trend toward an effect of radiation on BDNF levels in the cortex of males, but not for females, with higher levels in male mice irradiated with 50 cGy than sham-irradiated. Finally, sequential 6-ion irradiation impacted the composition of the gut microbiome in a sex-dependent fashion. Taxa were uncovered whose relative abundance in the gut was associated with the radiation dose received. Thus, exposure to sequential six-beam irradiation significantly affects behavioral and cognitive performance and the gut microbiome.

60 APPLIED LIFE SCIENCES↗

Roadmap on energy harvesting materials

Ambient energy harvesting has great potential to contribute to sustainable development and address growing environmental challenges. Converting waste energy from energy-intensive processes and systems (e.g. combustion engines and furnaces) is crucial to reducing their environmental impact and achieving net-zero emissions. Compact energy harvesters will also be key to powering the exponentially growing smart devices ecosystem that is part of the Internet of Things, thus enabling futuristic applications that can improve our quality of life (e.g. smart homes, smart cities, smart manufacturing, and smart healthcare). To achieve these goals, innovative materials are needed to efficiently convert ambient energy into electricity through various physical mechanisms, such as the photovoltaic effect, thermoelectricity, piezoelectricity, triboelectricity, and radiofrequency wireless power transfer. By bringing together the perspectives of experts in various types of energy harvesting materials, this Roadmap provides extensive insights into recent advances and present challenges in the field. Additionally, the Roadmap analyses the key performance metrics of these technologies in relation to their ultimate energy conversion limits. Building on these insights, the Roadmap outlines promising directions for future research to fully harness the potential of energy harvesting materials for green energy anytime, anywhere.

14 SOLAR ENERGY↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

The Role of Competitions in Speeding Energy-Efficient Technology Development and Adoption

This conference paper, which will be submitted for publication in the 2020 ACEEE Summer Study on Energy Efficiency in Buildings, describes competition approaches used by the U.S. Department of Energy (DOE) Building Technologies Office (BTO) and other government agencies to encourage the development and adoption of innovative new energy-efficient, high-performing products while spurring external competition to maximize limited resources. The competition model helps to disrupt traditional thinking and introduce, expand, and evolve what’s possible within limited resource conditions. DOE BTO has sponsored technology competitions, including campaigns, challenges, prizes, and technology procurements to speed the uptake of more efficient refrigerators, clothes washers, air conditioners, and many types of highly efficient lighting technologies, including compact fluorescent lamps (CFLs) and light-emitting diode LED-based home and office luminaires, replacement lamps, and street lighting. In this paper, we will draw upon the technology competition frameworks employed by DOE BTO to support ongoing research and development efforts to illustrate the differences between the approaches and to identify which type is likely to be the most effective in a given technology status and market context. We’ll also share examples of the various technology competition types and results. A question-and-answer table helps readers compare and contrast the four competition types. The paper concludes with a summary of lessons learned from past DOE BTO competitions. The paper will be available in the ACEEE 2020 Summer Study proceedings and a related presentation will be given at the conference.

U.S. Department of Energy Building Technologies Of↗

Analysis of Building Model Forecasts using Autonomous HVAC Optimization System for Residential Neighborhood

Heating, ventilation, and air conditioning (HVAC) systems account for the highest share of home energy consumption in the United States. Optimized HVAC control can provide thermal improved comfort to the occupants, improve energy efficiency, reduce energy cost, and support grid services. In this paper, we discuss a multi-agent and cloud-based software framework that has been deployed in occupied residential neighborhood. This system enables automatic data collection, learning, optimization, and dispatches signals to neighborhood devices. HVAC optimization is based on model predictive control (MPC). Since the operational performance of MPC depends on model forecasting accuracy, it is crucial to evaluate the model continuously and modify or retrain it as necessary. In this research, we developed an automated workflow to evaluate the performance of temperature and power forecasts based on measured data in the real world. This will provide researchers with a deeper understanding of the model and how it can be improved.

Lebakula, Viswadeep↗

Photovoltaic device innovation for a solar future

Photovoltaics (PV), also known as solar cells, are now found everywhere - in utility plants; on roofs of homes and commercial buildings; on platforms at sea; in agricultural fields; on vehicles, buildings, drones, and backpacks; and, in their longest running application, providing power in space. Continuous device innovation has led to increased efficiency and improved reliability for multiple PV technologies. Confronted with an urgent need to deploy PV at multiterawatt (TW) scale over the next two decades to mitigate greenhouse gas emissions, PV device innovation takes on new urgency and impact. This perspective reviews recent progress in device design and performance for PV technologies that are currently in commercial production at greater than 1 GW/year or enabling significant space-based power generation - Si, CdTe, CIGS, and multijunction III-V - and looks ahead to the next 5 years. In conclusion, we also identify device-related topics requiring cross-cutting research and innovation.

14 SOLAR ENERGY↗