High-Pulse Energy / High-Repetition Rate Laser
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The first isomerization reaction of an alkylperoxy (RO 2 ) radical holds significant importance in low-temperature oxidation, as it governs the branching ratios of the hydroperoxyalkyl (QOOH) radicals, which influence the competition between the chain-propagation and chain-branching reactions. In this study, we systematically calculated high-pressure rate rules for the RO 2 isomerization reaction of monoethers, exploring 5-, 6-, 7-, and 8-membered ring transition states. Primary, secondary, and tertiary carbon sites, where both the abstracting peroxy group and the abstracted hydrogen are located, were considered, with particular emphasis on distinguishing between secondary carbons adjacent (alpha) and nonadjacent to the ether functional group. Using the G4//B3LYP/6-311++G(2df,2pd) level of theory and the transition state theory, we estimated the rate constants and the Arrhenius coefficient for over 120 possible isomerization reactions. We examined the effect of ring size and ring atoms, revealing that 6- and 7-membered ring isomerizations were generally the fastest. The impact of the ether functional group on transition states was investigated by comparing reactions with identical ring size, peroxy, and radical positions, but with the ether functional group positioned either outside (i.e., out) or inside (i.e., in) the transition state ring, leading to differences in the rate constants. When comparing to analogous alkane rate constants, differences of up to an order of magnitude were observed, underscoring the need for caution when assigning rate rules by analogy. We applied our rate constants in the di-iso-butyl ether kinetic model and evaluated their influence on low-temperature chemistry finding that they altered the branching ratios by up to a factor of 9, highlighting the significance of site-specific rate constants for more accurate low-temperature modeling.
The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.
Here, we illustrate what happens inside the catalytic cleft of an enzyme when substrate or ligand binds on single-millisecond timescales. The initial phase of the enzymatic cycle is observed with near-atomic resolution using the most advanced X-ray source currently available: the European XFEL (EuXFEL). The high repetition rate of the EuXFEL combined with our mix-and-inject technology enables the initial phase of ceftriaxone binding to the Mycobacterium tuberculosis β-lactamase to be followed using time-resolved crystallography in real time. It is shown how a diffusion coefficient in enzyme crystals can be derived directly from the X-ray data, enabling the determination of ligand and enzyme–ligand concentrations at any position in the crystal volume as a function of time. In addition, the structure of the irreversible inhibitor sulbactam bound to the enzyme at a 66 ms time delay after mixing is described. This demonstrates that the EuXFEL can be used as an important tool for biomedically relevant research.
Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.
The multiplexing capabilities of superconducting X-ray free-electron lasers (FELs) have gained much attention in recent years. The demanding requirements for photon properties from multiple undulator lines necessitate more flexible beam manipulation techniques to achieve the goal of “beam on demand”. In this paper, we investigate a multiplexed configuration for the photoinjector of high-repetition-rate FELs that aims to simultaneously provide low-emittance electron beams of different charges. A parallel, multi-objective genetic algorithm is implemented for the photoinjector parameter optimization. The proposed configuration could drastically enhance the flexibility of beam manipulation to improve multiplexing capabilities and realize the full potential of the facility.
Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.
4D scanning transmission electron microscopy (STEM) is experiencing a revolution both in terms of data size, and data veracity, as are many other areas of experimental data acquisition. This presents enormous opportunities to make new scientific discoveries, but is also hamstrung by aging software that is no longer fit for purpose. Experimental data acquisition platforms must make the same investments in software infrastructure that the simulation community made decades ago to take advantage of high-performance computing (HPC) if they hope to realize the full potential of the latest advances made in detector technology. This requires rethinking the design and deployment of hardware, moving away from small, fixed commodity computing capabilities with closed interfaces to open, modular, scalable systems designed for parallelism and throughput. The technical approach will leverage best-in-class open source technologies, and develop new approaches strategically to build an open source platform for experimental data acquisition targeting high data rate electron microscopy. The project will develop a software platform that uses the power and performance of modern HPC resources to ingest the large volume of data produced by electron microscopes using direct electron detectors. A set of configurable pipelines will be used to enable the processing to be tailored to the problem being investigated with builtin visualization of data at interactive rates. This project will leverage investments made by the DOE and other agencies to provide a powerful software platform for the experimental data community working with most powerful electron microscopes, such as 4D STEM detectors. It will create a platform that serves as a reference for the community. Permissive open source licensing will make the platform available to all, with a simple deployment strategy offering the ability to keep data close to where it is generated. This advanced software platform will require customization for each deployment, creating opportunities for software services that are typically offered to extend open source software platforms.
Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.
In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.
We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.
The scheduler is a crucial component of the multipath transmission control protocol (MPTCP) that dictates the path that a data packet takes. Schedulers are in charge of delivering data packets in the right order to prevent delays caused by head-of-line blocking. The modern Internet is a complicated network whose characteristics change in real-time. MPTCP schedulers are supposed to understand the real-time properties of the underlying network, such as latency, path loss, and capacity, in order to make appropriate scheduling decisions. However, the present scheduler does not take into account all of these characteristics together, resulting in lower performance. We present the low latency and high data rate (LLHD) scheduler, which successfully makes scheduling decisions based on real-time information on latency, path loss, and capacity, and achieves around 25% higher throughput and 45% lower data transmission delay than Linux’s default MPTCP scheduler.
We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.
High-entropy alloys (HEAs) fabricated by powder metallurgy are considered to exhibit extremely-great potential application values in the field for high-speed impact deformation due to their uniform microstructures and compositions. The mechanical behavior of a powder-metallurgy-fabricated (PM) CoCrFeMnNi HEA was investigated at room temperature with strain rates ranging from 1200 s -1 to 2800 s -1 . It was found that the serration behavior and shear localization of the alloy under dynamic conditions occurred. Results also indicated that the serrated flow took place in the PM CoCrFeMnNi HEA during mechanical deformation at high strain rates (>1000 s -1 ) and became more pronounced as the strain rate increased. Furthermore, it was determined that the yield-strength values of the PM CoCrFeMnNi HEA were sensitive to strain rates, where the values increased from 500 MPa to 700 MPa when the strain rates increased from 1200 s -1 to 2800 s -1 . Shear bands with a width of about 20 μm were generated in the PM CoCrFeMnNi HEA after the shear stress reached a maximum value of 635 MPa, which corresponded to a nominal strain of about 8.71. Nanotwins and ultrafine-equiaxed grains with a diameter of about 150 nm also developed at the core of the shear band during deformation. The results revealed that the strength of the shear band was much higher than that of the matrix grain. Nanotwins in the shear band were composed of a single face-centered-cubic (FCC) structure with the twin plane of ($\bar{1}$1$\bar1$), which could be formed via a rotational dynamic recrystallization (RDR).
Uncovering the truth of lithium polymer batteries. Lithium metal is the holy grail of anodes due to its 10-fold higher gravimetric capacity than graphite. All-solid-state lithium polymer electrolyte batteries are receiving significant attention due to their increased flexibility compared to inorganic solid-state electrolytes, which enhances processability, accommodates cell swelling, and enables more homogeneous interphases. However, prototype solid-state lithium polymer electrolyte batteries have been limited in their usage due to the low ionic conductivity of the electrolyte, which limits their ability to cycle lithium metal at high rates. In this opinion, we provide alternative interpretations of high-rate capability lithium metal polymer electrolytes and breakthroughs in highly ionically conductive all-solid-state polymer electrolytes. In addition, we provide guidance on how to characterize and evaluate polymer electrolytes in lithium metal batteries.
Background Dislocation dynamic simulations are intended as a tool to understand and predict the mechanical behavior of metallic materials, but its prediction has never been directly verified by experiments due to differences in specimen strain rate and size. Objective In this work, a comprehensive experimental framework is proposed to attempt direct comparison between experiments and discrete dislocation dynamics (DDD) modelling. Methods By integrating high-throughput sample fabrication and a customized testing apparatus, the sample size and strain rate typically employed in DDD simulations are explored experimentally. Constitutive properties such as stress-strain response are measured, and microstructural information is obtained from transmission electron microscopy (TEM) imaging, electron backscatter diffraction (EBSD), and TEM-based orientation mapping. Results Magnesium and copper were selected, as case studies, to demonstrate the newly developed experimental procedure. Measured stress-strain responses for Mg are consistent with those obtained with a miniaturized Hopkison bar experiments. Furthermore, by exploiting the validated workflow, the effect of strain rate on micropillar heterogeneous deformation and associated dislocation plasticity were revealed. Conclusion The work establishes a methodology for the systematic study of not only metals but also other materials and structures at the microscale and high strain rates.
We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.
Abstract not provided