Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heterodyne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Noise effects in an optical heterodyne spectrometer using tunable diode lasers

A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.

Katzberg, S. J.↗

Infrared heterodyne spectroscopy

Infrared heterodyne spectroscopy is an extremely useful tool for Doppler-limited studies of atomic and molecular lines in diverse astrophysical regions. The current state of the art is reviewed, and the analysis of CO2 lines in the atmosphere of Mars is outlined. Doppler-limited observations have enabled the discovery of natural laser emission in the mesosphere of Mars and the discovery of failure of local thermodynamic equilibrium near the surface of Mars.

Mumma, M. J.↗

High resolution atmospheric spectroscopy using a diode laser heterodyne spectrometer

Ultrahigh resolution (0.007 per cm) atmospheric solar absorption spectra that have been obtained from a tunable infrared heterodyne radiometer are discussed. The radiometer was developed for ground based observations in the 8-12 micron region, and tunability is achieved through the use of Pb-salt semiconductor laser local oscillators. Spectra have been obtained in a piecewise fashion from 9.1 to 11.1 microns using laser emission modes that exhibit characteristics suitable for local-oscillator operation. Spectra showing absorption features of HNO3, O3, CO2, and H2O are presented along with comparisons of experimental and synthetic spectra calculated using a line-by-line atmospheric transmission model.

Hoell, J. M., Jr.↗

Preliminary submillimeter spectroscopic measurements using a submillimeter heterodyne radiometer

A submillimeter heterodyne radiometer uses a submillimeter laser, pumped by a CO2 laser, as a local oscillator and a room temperature Schottky barrier diode as the first IF mixer. The radiometer can resolve spectral lines in the submillimeter region of the spectrum (arising from pure rotational molecular transitions) to within 0.3 MHz, using acousto-optic spectrum analyzer which measures the power spectrum by simultaneously sampling 0.3 MHz wide channels over a 100 MHz bandwidth spanning the line. Preliminary observations of eight spectral lines of H2O2, CO, NH3 and H2O, all lying in the 434-524 micrometer wavelength range are described. All eight lines were observed using two local oscillator frequencies obtained by operating the submillimeter laser with either methyl fluoride (CH3F) or formic acid (HCOOH) as the lasing gas. Sample calculations of line parameters from the observed data show good agreement with established values. One development goal is the size and weight reduction of the package to make it suitable for balloon or shuttle experiments to detect trace gases in the upper atmosphere.

Safren, H. G.↗

InSb heterodyne receivers for submillimeter astronomy

InSb hot electron bolometer mixer receivers have been developed for submillimeter line studies of the interstellar medium up to about 500 GHz. The receivers have been used aboard the NASA Kuiper Airborne Observatory which is transported to about 12,000 km by a C141 aircraft. Data have been obtained on new interstellar lines (such as the ground-state fine structure transition of atomic carbon at 492 GHz) and such molecular transitions as carbon monoxide and water. Other data were obtained at ground level using the 5-cm Hale telescope at Mount Palomar and the NASA Infrared Telescope facility at Mauna Kea, HI. The heterodyne bolometers have reached noise temperatures of less than 400 K at all frequencies to 500 GHz.

Phillips, T. G.↗

433 micron laser heterodyne observations of galactic CO from Mauna Kea

A submillimeter heterodyne radiometer, developed for astronomical applications, uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer. The resultant telescope-mounted system, which has a noise temperature less than 4000 K (double sideband) and high frequency and spatial resolution, has been used to detect the J = 6 to 5 rotational transition of carbon monoxide at 434 micrometers in the Orion molecular clouds. The measurements, when compared with previous millimeter-wave data, indicate that the broad carbon monoxide emission feature is produced by an optically thin gas whose temperature exceeds 180 K.

Buhl, D.↗

Experimental comparison of heterodyne and direct detection for pulsed differential absorption CO2 lidar

A pulsed dual-wavelength dual-CO2-laser differential-absorption lidar (DIAL) system has been developed which permits simultaneous heterodyne and direct detection of the same lidar returns. This system has been used to make an experimental comparison of the SNRs and statistical and temporal characteristics of the DIAL returns from several topographic targets. These results were found to be in general agreement with theory and were used to quantify the relative merits of the two detection techniques. The measured parameter values were applied to an analytical treatment to predict system trade-offs for the remote sensing of atmospheric species, with application to both path-averaged and range-resolved measurements.

Killinger, D. K.↗

Diode laser heterodyne observations of silicon monoxide in sunspots - A test of three sunspot models

Absorption features from the 8 micron SiO fundamental (upsilon = 1-0) and hot bands (upsilon = 2-1) have been observed in sunspots at sub-Doppler resolution using a ground-based tunable diode laser heterodyne spectrometer. The observed line widths suggest an upper limit of 0.5 km/s for the microturbulent velocity in sunspot umbrae. Since the silicon monoxide abundance is very sensitive to sunspot temperature, the measured equivalent widths permit an unambiguous determination of the temperature-pressure relation in the upper layers of the umbral atmosphere. In the region of SiO line formation (log P sub g = 3.0-4.5), the results support the sunspot model suggested by Stellmacher and Wiehr (1970).

Glenar, D. A.↗

A re-evaluation of laser heterodyne radiometer ClO measurements

Previously reported measurements of stratospheric ClO using a balloon-borne laser heterodyne radiometer, launched from Palestine, Texas, are re-evaluated as a result of recent spectroscopic data. A spectral feature which was observed during September, 1978 and November, 1979 flights was incorrectly identified as a ClO absorption line, while a second feature observed during the latter flight with somewhat limited sensitivity is now believed to be due to ClO. This new interpretation results in a measured ClO profile which falls off more rapidly with decreasing altitude than the previous results indicated.

Menzies, R. T.↗

Thermal bifurcation in the upper solar photosphere inferred from heterodyne spectroscopy of OH rotational lines

Low noise high spectral resolution observations of two pure rotation transitions of OH from the solar photosphere were obtained. The observations were obtained using the technique of optically null-balanced infrared heterodyne spectroscopy, and consist of center-to-limb line profiles of a v=1 and a v=0 transition near 12 microns. These lines should be formed in local thermodynamic equilibrium (LTE), and are diagnostics of the thermal structure of the upper photosphere. The v=0 R22 (24.5)e line strengthens at the solar limb, in contradiction to the predictions of current one dimensional photospheric models. Data for this line support a two dimensional model in which horizontal thermal fluctuations of order + or - 800K occur in the region Tau (sub 5000) approximately .001 to .01. This thermal bifurcation may be maintained by the presence of magnetic flux tubes, and may be related to the solar limb extensions observed in the 30 to 200 micron region.

Deming, D.↗

Development of long wavelength semiconductor diode lasers near 28 microns for use in infrared heterodyne spectrometers

The development of tunable diode lasers operating in the 28 micrometers spectral region for use in infrared heterodyne spectrometers is reported. A process capable of yielding lasers emitting 500 micron W of multimode power, 112 micron W in a true single mode and true single mode operation at laser currents of up to 35% above threshold was developed. Results were obtained from narrow mesastripe (20 micrometer wide) short cavity (120 micrometer length) laser configurations. Six stripe geometry lasers, with a variety of cavity widths and lengths were delivered. The techniques to fabricate such devices was obtained and the long term reliability of such lasers by reproducible electrical and optical output characteristics fabrication from lasers are demonstrated.

Linden, K. J.↗

Automated control and data acquisition for a tunable diode laser heterodyne spectrometer

This paper describes the hardware and software design, development, and implementation of the control and data electronics of a laser heterodyne spectrometer instrument being built at NASA Langley Research Center for a technology demonstration. Functional partitioning, applied at all levels of hardware and software, has been found to provide expedient design, development, and testing of the instrument. The instrument is composed of distributed microprocessor-based units. A master/slave protocol is presented which can be simulated by a terminal for unit checkout. All but one of the units are implemented using a set of core boards, plus unique boards where necessary. This design has led to reduced hardware development, reduced parts inventory, and replication of software modules, while providing the flexibility needed for a development instrument. The development tools and documentation guidelines are discussed.

Shull, T. S.↗

A new thermal radiation detector using optical heterodyne detection of absorbed energy

The operating principles of a new kind of room-temperature thermal radiation detector are described. In this device modulated light heats a gas, either directly or by conduction from a thin absorbing membrane, and the resultant change in density of the gas is detected by optical heterodyning. The performance of a membrane device of this kind agrees well with the predictions of theory.

Davis, C. C.↗

The use of heterodyne speckle photogrammetry to measure high-temperature strain distributions

Thermal and mechanical strains have been measured on samples of a common material used in jet engine burner liners, which were heated from room temperature to 870 C and cooled back to 220 C, in a laboratory furnace. The physical geometry of the sample surface was recorded to select temperatures by means of a set of twelve single-exposure specklegrams. Sequential pairs of specklegrams were compared in a heterodyne interferometer which allowed high-precision measurement of differential displacements. Good speckle correlation was observed between the first and last specklegrams also, which showed the durability of the surface microstructure, and permitted a check on accumulated errors. Agreement with calculated thermal expansion was to within a few hundred microstrain over a range of fourteen thousand.

Stetson, K. A.↗

The 12 micron band of ethane - High-resolution laboratory analysis with candidate lines for infrared heterodyne searches

Attention is given to the results of a laboratory study of the v9 band of ethane at 12 microns, using both high resolution Fourier transform and diode laser absorption spectroscopy. The analysis to which about 2000 transitions in this band have been subjected includes the normal rotational terms as well as the higher order effects of l-doubling, l-resonance, internal rotation, and a Coriolis resonance with the 3v4 state. A model is presented for the v9 band which is able to reproduce the observed features to an accuracy of better than 0.001/cm, and a list has been compiled for v9 transitions, occurring near C-14O2 laser lines, that are good candidates for laser heterodyne searches.

Atakan, A. K.↗

Heterodyne frequency measurements and frequency calibration standards for tunable diode lasers

New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.

Wells, J. S.↗

Refractive turbulence effects on truncated Gaussian beam heterodyne lidar

A monostatic heterodyne lidar performance model is formulated to study the combined effects of beam truncation and refractive turbulence in the weak scintillation regime. The results show that there is a loss of signal power due to beam truncation and coherence loss, but there is also an enhancement of signal power due to log-amplitude covariance in suitable conditions of long paths with weak turbulence.

Murty, R.↗

Tunable Heterodyne Receiver from 100 Micron to 1,000 Micron for Airborne Observations

Interest in high resolution spectrometers for the submillimeter wavelength range from 100 micron to 1,000 micron is mostly stimulated by molecular spectroscopy in radioastronomy and atmospheric physics, and by plasma diagnostic experiments. Schottky diodes in waveguide mixer technology and InSb-hot electron bolometers are successfully used in the 0.5 to a few millimeter range whereas tandem Fabry-Perot spectrometers combined with photoconductive detectors (Ge:Sb and Ge:Ga) are used for the 100 micron range. Recent research on heterodyne spectrometers, with Schottky diodes in an open structure mixer and a molecular laser as local oscillators, which can be used over the whole wavelength range is summarized.

Roeser, H. P.↗