Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat leak”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Reusable Solid Rocket Motor Nozzle Joint-4 Thermal Analysis

This study provides for development and test verification of a thermal model used for prediction of joint heating environments, structural temperatures and seal erosions in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzle Joint-4. The heating environments are a result of rapid pressurization of the joint free volume assuming a leak path has occurred in the filler material used for assembly gap close out. Combustion gases flow along the leak path from nozzle environment to joint O-ring gland resulting in local heating to the metal housing and erosion of seal materials. Analysis of this condition was based on usage of the NASA Joint Pressurization Routine (JPR) for environment determination and the Systems Improved Numerical Differencing Analyzer (SINDA) for structural temperature prediction. Model generated temperatures, pressures and seal erosions are compared to hot fire test data for several different leak path situations. Investigated in the hot fire test program were nozzle joint-4 O-ring erosion sensitivities to leak path width in both open and confined joint geometries. Model predictions were in generally good agreement with the test data for the confined leak path cases. Worst case flight predictions are provided using the test-calibrated model. Analysis issues are discussed based on model calibration procedures.

Clayton, J. Louie↗

Compressor Station Differential Risk Assessment for Hydrogen and Natural Gas Blends

Blending hydrogen into existing natural gas pipelines is a current initiative for large-scale hydrogen deployment in the United States. Understanding changes in hazards and risk for fuel blends can help inform regulations. A differential risk assessment was conducted to understand how the safety profile of fires and unignited flammable plumes of leaking fuel would change based on blend composition. The area affected by harmful heat fluxes from jet fires was found to be larger for blends with more natural gas in them, while the distance affected by unignited flammable fuel concentrations was found to be larger for blends with more hydrogen in them. Component leak frequencies and ignition probabilities greatly impact both heat flux risk and the flammable plume risk. The collection of additional blend-specific industry data could help understand which assumptions are most valid to make when calculating risk.

08 HYDROGEN↗

Direct-Interface, Fusible Heat Sink

Nonventing, regenerable, and self-contained heat sink absorbs heat in melting of ice by direct contact with forced flow of warm water. Elastic bladder contains water and ice. Connectors designed to prevent leaks easily connectable and disconnectable. Female portions embedded in wall of heat sink. After water frozen, male portions inserted and flow of warm water initiated. Water melts ice in and around female connectors, then flow passes between ice and bladder from inlet to outlet. Component of low-power portable refrigerator to operate for short time in picnic or camp setting.

Lomax, Curtis↗

Counterstreaming suprathermal electron events upstream of corotating shocks in the solar wind beyond approximately 2 AU: Ulysses

Enhanced fluxes of suprathermal electrons are commonly observed upstream of corotating forward and reverse shocks in the solar wind at heliocentric distances beyond approximately 2 AU by the Los Alamos plasma experiment on Ulysses. The average duration of these events, which are most intense immediately upstream from the shocks and which fade with increasing distance from them, is approximately 2.4 days near 5 AU. These events are caused by the leakage of shock-heated electrons into the upstream region. The upstream regions of these shocks face back toward the Sun along the interplanetary magnetic field, so these leaked electrons commonly counterstream relative to the normal solar wind electron heat flux. The observations suggest that conservation of magnetic moment and scattering typically limit the sunward propagation of these electrons as beams to field-aligned distances of approximately 15 AU. Although it seems unlikely that these shock-associated events are an important source of counterstreaming events near 1 AU, remnants of the backstreaming beams may contribute importantly to the diffuse solar wind halo electron population there.

Gosling, J. T.↗

EMC3-EIRENE simulation of first wall recycling fluxes in W7-X with relation to H-alpha measurements

In the Wendelstein 7-X stellarator, the main locations of particle sources are expected to be the carbon divertors, baffles and graphite heat shield first wall. In this paper, the heat shield is implemented in EMC3-EIRENE to understand the expected areas and magnitudes of the recycling flux to this component. It is found that in the simulation the heat shield is not a significant source of recycling neutrals. The areas of simulated recycling flux are shown to correlate well with footprints of plasma-wetting seen in post-experimental campaign in-vessel inspection photos. EMC3-EIRENE reconstruction of line-integrated H-alpha measurements at the heat shield indicate that the majority of emission does not come from local recycling neutrals. Rather, the H-alpha signals at the heat shield are dominated by ionization of neutrals which have leaked from the divertor/baffle region into the midplane. The magnitude of the H-alpha line emission from the synthetic reconstruction is consistent with the experiment, indicating that a large overestimation of heat shield recycling would occur if these measurements were assumed to be from local recycling sources. In the future, it may be possible to obtain some information of local recycling from the heat shield since it was found that the majority of the recycling flux occurs on two well-localized areas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Water Quality Contamination Sources and Controls for the Exploration Extra-vehicular Mobility Unit (xEMU)

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. The xEMU uses controlled evaporative cooling through a membrane to reject waste heat from the crewmember, avionics, and environmental in-leak during autonomous operation. Given the unique mass and volume constraints imposed by the spacesuit application and the opportunities presented by the selection of a given membrane, the xEMU does not possess a separate feedwater loop to feed the evaporation process, rather the feedwater for the evaporation process is fed directly from the transport loop which collects heat from the sources within the suit. This has many benefits including mass/volume reductions from a lower component count within the system but does pose some additional potential constraints on water quality within the system in order to provide a working fluid that can be pumped, filtered, and used in contact with the remainder of the system while both avoiding fouling of the membrane as well as other deleterious effects such as creating conditions for corrosion of wetted surfaces within the transport loop. The discussion will seek to address the main sources of contamination and the applied controls. Sources considered will include: self-generated via materials selection and processes applied, influent working fluid, contamination of the influent working fluid via Ground Support Equipment (GSE) or processing equipment, microbial activity, and environmental influences such as elevated ambient CO2.

Colin Campbell↗

Ammonia Vent of the External Active Thermal Control System (EATCS) Radiator #3 Flow Path #2 on the International Space Station (ISS)

The External Active Thermal Control System (EATCS) provides cooling for all pressurized modules and the main Power Distribution Electronics (PDE) on the International Space Station (ISS). There are 2 EATCS loops (Loop A and Loop B) which includes 3 deployable radiators. Each deployable radiator contains 2 flow paths to provide heat rejection.Telemetry monitoring identified a coolant (liquid ammonia) leak in EATCS Loop B. Robotic External Leak Locator (RELL) scans found higher concentrations of vaporous ammonia near the EATCS Loop B Radiator #3 Flow Path #2. On May 3, 2017, the EATCS Loop B Radiator #3 Flow Path #2 was isolated and vented. As of the data to date, the ammonia leak has ceased. The purpose of this presentation is to discuss the analysis for venting the EATCS Loop B Radiator #3 Flow Path #2. Venting analysis is performed to determine the worst case time to empty the flow path and maximum thrusts imposed on the ISS. Flight controllers and engineers in the Mission Control Center (MCC) uses this data to develop operational procedures and perform the vent safely. It was predicted that the worst case time to empty the EATCS Loop B Radiator #3 Flow Path #2 was ~ 60 minutes. The predicted maximum thrusts were ~ 11 lbf (49 N) at the start of the vent and ~10 lbf (45 N) after the system reaches saturation.The vent was successfully performed and took ~ 20 minutes to empty the EATCS Loop B Radiator #3 Flow Path #2. Using telemetry from the day of the vent, analysis determined the time to empty the EATCS Loop B Radiator #3 Flow Path #2 would be ~13 minutes. The predictive analysis used worst case inputs and assumptions which bounded the actual results. Telemetry is not available to correlate actual thrust with the predicted maximum thrusts. However, by using Russian Thrusters for ISS attitude control, attitude control telemetry indicated the flight attitude was maintained.

Cowan, Darnell T.↗

Consumer Guide to Home Water Efficiency

Learn how a water-efficient home helps you minimize your water use, harness water for reuse, conserve energy, and save money. This fact sheet from Energy Saver includes information on ENERGY STAR-qualified appliances, why to improve water efficiency, and how to save water and energy.

water efficiency, water heating, saving water, wat↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Characteristic of cryogenic hydrogen flames from high-aspect ratio nozzles

Unintentional leaks at hydrogen fueling stations have the potential to form hydrogen jet flames, which pose a risk to people and infrastructure. The heat flux from these jet flames are often used to develop separation distances between hydrogen components and buildings, lot-lines, etc. The heat flux and visible flame length is well understood for releases from round nozzles, but real unintended leaks would be expected to be from higher aspect-ratio cracks. Here, we measured the visible flame length and heat-flux characteristics of cryogenic hydrogen flames from high-aspect ratio nozzles. Heat flux measurements from 5 radiometers were used to assess the single-point vs the multi-point methods for interpretation of heat flux sensor data, finding the axial distance of the sensor for a single-point heat flux measurement to be important. We compare the flame length and heat flux data to flames of both cryogenic and compressed hydrogen from round nozzles. The aspect ratio of the release does not affect the flame length or heat flux significantly, for a given mass flow under the range of conditions studied. The engineering correlations presented in this work enable the prediction of flame length and heat flux which can be used to assess risk at hydrogen fueling stations with liquid hydrogen and develop science-based separation distances for these stations.

08 HYDROGEN↗

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

Hybrid Thermal Control System for Extreme Thermal Environments

NASA’s return to the moon brings about many challenges, including issues with survival on the Lunar surface. Marshall Space Flight Center (MSFC) has been developing a hybrid thermal control system that can be utilized for various surface assets that must survive in extreme lunar environments. This scalable system is targeted for human-rated systems and utilizes a combination of a- pumped fluid loop (PFL) and a loop heat pipe (LHP) with thermal control valve (TCV). Pumped fluid loops have a long history of use in human rated systems. They can collect large amounts of waste heat and transport it over long distances in rovers, habitats, and other systems. By utilizing a non-toxic working fluid in the habitable volume, the PFL is easily serviceable by the crew and does not pose a risk during any unexpected leaks or failures. The addition of a LHP for the exterior heat transport and rejection adds several benefits to the system for extreme environment survival. The quantity of LHP scan be tailored to optimize heat rejection for different systems and allows for larger adiative surfaces. By utilizing a TCV in combination with the LHP, there can be high heat transfer during the daytime with minimal heat transfer during the night. The TCV passively controls the amount of heat transfer through the LHP based on the environmental temperature. A prototype system has been tested in bench top and thermal vacuum conditions. Results are presented showing the feasibility of the system concept.

Thermal Control↗

Sizing an emergency venting system for a cryogenic dewar

If the vacuum vessel that insulates a cryogenic dewar for a spaceborne experiment prior to launch is damaged, air will leak into the vacuum insulation space. As the sudden heat load causes the pressure to rise in the dewar, a safety disk in the emergency vent line will burst at the design pressure differential to allow vaporized cryogenic fluid to escape. The emergency vent line should be sized such that sufficient gaseous cryogen will be vented to keep the pressure inside the dewar below the design limit. On the other hand, the line should not be so large as to impose an unnecessary heat load on the dewar filled with cryogenic fluid. A vent-line computer program was generated to compute the maximum flow rate allowed for a proposed vent-line system. Parametric studies have been carried out for different burst disk pressure differentials, liquid cryogen ullage, and vent-line sizes.

Liu, C. K.↗

Detection, Location, and Classification of Space Shuttle Main Engine Nozzle Leaks by Transient Thermographic Inspection

Leak checking and evaluation of pressure vessels by observing the slight temperature changes resulting from structural anomalies has been made possible through developments in high resolution infrared cameras and advanced image processing. These developments have made thermal nondestructive analysis a very practical and efficient method to determine material consistency and structural quality as well as monitor processes. The Space Shuttle Main Engine Nozzle has regions which can not be inspected with standard leak check methods. The Thermographic methods being developed to nondestructively test the Nozzle for leaks in inaccessible regions are reported. Also, a flash heating Thermographic investigation of the braze line bonding the cooling tubes to the outer structural jacket of the nozzle is reported.

Russell, Samuel S.↗

Adhesion of Silicone Elastomer Seals for NASA's Crew Exploration Vehicle

Silicone rubber seals are being considered for a number of interfaces on NASA's Crew Exploration Vehicle (CEV). Some of these joints include the docking system, hatches, and heat shield-to-back shell interface. A large diameter molded silicone seal is being developed for the Low Impact Docking System (LIDS) that forms an effective seal between the CEV and International Space Station (ISS) and other future Constellation Program spacecraft. Seals between the heat shield and back shell prevent high temperature reentry gases from leaking into the interface. Silicone rubber seals being considered for these locations have inherent adhesive tendencies that would result in excessive forces required to separate the joints if left unchecked. This paper summarizes adhesion assessments for both as-received and adhesion-mitigated seals for the docking system and the heat shield interface location. Three silicone elastomers were examined: Parker Hannifin S0899-50 and S0383-70 compounds, and Esterline ELA-SA-401 compound. For the docking system application various levels of exposure to atomic oxygen (AO) were evaluated. Moderate AO treatments did not lower the adhesive properties of S0899-50 sufficiently. However, AO pretreatments of approximately 10(exp 20) atoms/sq cm did lower the adhesion of S0383-70 and ELA-SA-401 to acceptable levels. For the heat shield-to-back shell interface application, a fabric covering was also considered. Molding Nomex fabric into the heat shield pressure seal appreciably reduced seal adhesion for the heat shield-to-back shell interface application.

deGroh, Henry C., III↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Thermal-leak analyzer for vacuum-jacketed lines

Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.

Heisman, R. M.↗

Heat and mass transfer during a sudden loss of vacuum in a liquid helium cooled tube - Part III: Heat deposition in He II

A sudden loss of vacuum can be catastrophic for superconducting particle accelerators. In such an event, air leaks into the liquid-helium-cooled accelerator beamline tube and condenses on its inner surface, causing rapid boiling of the helium and dangerous pressure build-up. Understanding the coupled heat and mass transfer processes is important for the design of the beamline cryogenic system. Our past experimental study on nitrogen gas propagating in a copper tube cooled by normal liquid helium (He I) has revealed a nearly exponential slowing down of the gas front. A theoretical model that accounts for the interplay of the gas dynamics and the condensation was developed, which successfully reproduced various key observations. However, since many accelerator beamlines are actually cooled by superfluid helium (He II) in which the heat transfer is via a non-classical thermal counterflow mode, we need to extend our work to the He II cooled tube. This paper reports our systematic measurements using He II and the numerical simulations based on a modified model that accounts for the He II heat-transfer characteristics. By tuning the He II peak heat-flux parameter in our model, we have reproduced the observed gas dynamics in all experimental runs. The fine-tuned model is then utilized to reliably evaluate the heat deposition in He II. Finallly, this work not only advances our understanding of condensing gas dynamics but also has practical implications to the design codes for beamline safety.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗