Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Hawaii Play Fairway Analysis: Noble Gas Raw Data for Hawaii, Maui, Oahu, Kauai, and Lanai islands

Noble gas raw data for the Hawaiian islands of Big Island, Maui, Oahu, Lanai, and Kauai. Based on results from prior phases of the Hawaii Play Fairway Analysis, this project targeted 66 wells on the islands of Hawaii, Maui, Lanai, Oahu, and Kauai for sampling of dissolved noble gases, trace metals, common ions, and the stable isotopes 2H and 18O. Ultimately, 23 of the 66 well targets were sampled. Noble gas data from this study is supplemented with data shared by the United States Geologic Survey for the summit of Kilauea, and by the geothermal energy company Ormat Technologies Inc. for their geothermal power plant Puna Geothermal Venture on the Lower East Rift of Kilauea, and for their exploration of Kona and Hualalai on Hawaii, as well as the Southwest Rift of Haleakala on Maui. The noble gas helium is used as an indicator of geothermal heat when excess 3He and/or 4He is present when compared to the atmospheric ratio of those isotopes (R/Ra). R/Ra is minimally affected by dilution and transport, allowing even those wells not perfectly situated over a geothermal system to indicate a geothermal anomaly. R/Ra anomalies are present on every island in this study. There is a strong correlation between R/Ra anomalies and proximity to rift zones and calderas. The Hawaii Play Fairway project was funded by the U.S. Department of Energy Geothermal Technologies Office (award DE-EE0006729). For more information, see Colin Ferguson's Master of Science thesis "Exploration for Blind Geothermal Resources in the State of Hawaii Utilizing Dissolved Noble Gasses in Well Waters."

15 GEOTHERMAL ENERGY↗

Probabilistic Analysis of Gas Turbine Field Performance

A gas turbine thermodynamic cycle was computationally simulated and probabilistically evaluated in view of the several uncertainties in the performance parameters, which are indices of gas turbine health. Cumulative distribution functions and sensitivity factors were computed for the overall thermal efficiency and net specific power output due to the thermodynamic random variables. These results can be used to quickly identify the most critical design variables in order to optimize the design, enhance performance, increase system availability and make it cost effective. The analysis leads to the selection of the appropriate measurements to be used in the gas turbine health determination and to the identification of both the most critical measurements and parameters. Probabilistic analysis aims at unifying and improving the control and health monitoring of gas turbine aero-engines by increasing the quality and quantity of information available about the engine's health and performance.

Gorla, Rama S. R.↗

Experimental analysis of gas dynamics in the reactor cavity section of a High-Temperature Gas-Cooled Reactor during an accident scenario

Here, this study investigates the behavior of a High-Temperature Gas-Cooled Reactor (HTGR) during a break of the helium pressure boundary event. Understanding the gas dynamics that occur during a break could help develop safety systems that reduce the probability of air entering the reactor core. To achieve this objective, experimental studies were conducted in a scaled-down HTGR experimental facility to provide information on the air-helium gas mixture within the confinement building and the impact of the ventilation system on the helium/air gas concentration following the depressurization event. The study evaluated different configurations, including active ventilation time scales, break sizes, and locations. The analysis of the active ventilation time revealed that a ventilation time of 22 seconds produced positive results, and smaller break sizes resulted in longer depressurization times, which improved the ventilation process. The orientation and elevation of the breaks had little effect on the oxygen concentration in the cavity but did impact the gas velocities.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural modification of fentanyls for their retrospective identification by gas chromatographic analysis using chloroformate chemistry

Abstract The one-step breakdown and derivatization of a panel of nine fentanyls to yield uniquely tagged products that can be detected by Electron Ionization Gas Chromatography-Mass Spectrometry (EI-GC-MS) is presented. The method involves the treatment of the synthetic opioids with 2,2,2-trichloroethoxycarbonyl chloride (TrocCl) at 60 °C for 3 h in dichloromethane and furnishes two products from one fentanyl molecule that can be used to retrospectively identify the original opioid. Parameters that were studied and fully optimized for the method included temperature, solvent, nature of scavenging base and reaction time. One of the two resulting products from the reaction bears the trichloroethoxycarbonyl (Troc) tag attached to the norfentanyl portion of the original opioid and greatly aids in the opioid detection and identification process. The methodology has been applied to the chemical modification of a panel of nine fentanyls and in all cases the molecular ion peak for the Troc-norfentanyl product bearing the distinctive trichloroethyl isotopic signature can be clearly observed. The method’s LLOD was determined to be 10 ng/mL while its LLOQ was found to be 20 ng/mL. This methodology represents the first application of chloroformates in the chemical modification of this class of synthetic opioids that are notoriously inert to common derivatization strategies available for GC–MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental and life cycle assessment analysis of gas emission from mechanically–biologically pretreated waste in a landfill with energy recovery

Highlights: • Bio-methane landfill emissions from different period (0, 4, 8, 16 weeks) MTB waste have been evaluated. • Electrical energy recoverable from landfill gas ranges from 11 to about 90 kW h/tonne. • Correlation between oxygen uptake, energy recovery and anaerobic gas production shows R{sup 2} ranging from 0.78 to 0.98. • LCA demonstrate that global impact related to gaseous emissions achieve minimum for 4 week of MBT. - Abstract: The global gaseous emissions produced by landfilling the Mechanically Sorted Organic Fraction (MSOF) with different weeks of Mechanical Biological Treatment (MBT) was evaluated for an existing waste management system. One MBT facility and a landfill with internal combustion engines fuelled by the landfill gas for electrical energy production operate in the waste management system considered. An experimental apparatus was used to simulate 0, 4, 8 and 16 weeks of aerobic stabilization and the consequent biogas potential (Nl/kg) of a large sample of MSOF withdrawn from the full-scale MBT. Stabilization achieved by the waste was evaluated by dynamic oxygen uptake and fermentation tests. Good correlation coefficients (R{sup 2}), ranging from 0.7668 to 0.9772, were found between oxygen uptake, fermentation and anaerobic test values. On the basis of the results of several anaerobic tests, the methane production rate k (year{sup −1}) was evaluated. k ranged from 0.436 to 0.308 year{sup −1} and the bio-methane potential from 37 to 12 N m{sup 3}/tonne, respectively, for the MSOF with 0 and 16 weeks of treatment. Energy recovery from landfill gas ranged from about 11 to 90 kW h per tonne of disposed MSOF depending on the different scenario investigated. Life cycle analysis showed that the scenario with 0 weeks of pre-treatment has the highest weighted global impact even if opposite results were obtained with respect to the single impact criteria. MSOF pre-treatment periods longer than 4 weeks showed rather negligible variation in the global impact of system emissions.

09 BIOMASS FUELS↗

Life-cycle greenhouse gas emissions analysis of battery-grade lithium production in Finland

Various countries are undertaking initiatives to domestically produce battery-related critical materials. Within Finland, Keliber Technology Oy is developing capabilities for battery-grade lithium hydroxide monohydrate (LHM) production from spodumene ores. A detailed life-cycle assessment (LCA) of this pathway is conducted to determine its life-cycle GHG impacts using Argonne's R&D GREET (Research and Development Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model. The analysis shows life-cycle GHG emissions of similar to 9.2 kg CO 2-eq /kg LHM, dominated by contributions from three energy sources - diesel, natural gas, and electricity - and two material inputs - lime (CaO) and soda ash (Na 2 CO 3 ). Sensitivity analyses highlight the potential to reduce these impacts using low-carbon electricity, sequestration of process CO 2 emissions generated during CaO and Na 2 CO 3 production, and bio-based energy for LHM production (by similar to 15 % each). A comparative analysis shows lower impacts for Keliber's LHM than for existing LHM production from Australian spodumene ores processed in China (by similar to 40 %).

CCS↗

In the Pursuit of Regolithic Howardites

The HED (Howardite, Eucrite and Diogenite) meteorite clan likely originate from the asteroid 4-Vesta [1]. Howardites (polymict breccias of eucritic and diogenitic material) are believed to originate from the vestan surface, and many contain regolith-like features (impact and/or melt clasts, fragmental breccia clasts, carbonaceous chondrite fragments), which may relate to regolith-formation processes. Noble gas analysis can help determine true regolithic nature, as Solar Wind (SW) is im-planted into grains at the upper-surfaces of solar system bodies lacking an atmosphere or magnetic field. Howardites from Ves-ta s true regolith would thus show evidence for SW components. Thus far, we have identified 5 regolithic howardites: LEW 85313; MET 00423; PRA 04401; SCO 06040 and EET 87513; based on our noble gas analyses, with the latter 3 showing some evidence for a planetary(+SW) component, likely related to CM-like material present in the assemblage [2-5]. However, we did not find a good correlation between SW content and other petro-logic regolithic features. Nor did we find an obvious correlation between SW and high siderophile element contents (Ni greater than 300 micrograms/gram), or an Al2O3 range of 8-9 wt% and eucrite/diogenite (E/D) ratio of 2:1 as suggested by [6] to be further regolith indicators. Here, we report our latest noble gas data for two howardites GRO 95535, GRO 95602 and a polymict eucrite EET 87518 in continuing research aimed at better understanding the vestan regolith. Results: Noble gas analysis was performed on an MAP 215-50 noble gas mass spectrometer using furnace step-heating. Our results, shown in Table 1, are compared with SW- (LEW 85313) and planetary-dominated (PRA 04401 ~60% CM) howardites [2]. EET 87518 is dominated by cosmogenic components. By comparison, both howardites show strong evidence for SW, with total Ne-20/Ne-22 ~8.7-8.8 (SW: Ne-20/Ne-22 13.78 [7]), and identical release patterns to our other CM-poor SW-rich samples. This suggests that these samples are from the vestan regolith. As they have lower Ni contents than suggested by [6], this further illustrates that these parameters may show some bias [2].

Cartwright, J. A.↗

Surge and Stall Detection Using Acoustic Analysis FOR GAS Turbine Hybrid Cycles

In this article compressor dynamics were studied in a gas turbine - fuel cell hybrid power system having a larger compressor volume than traditionally found in gas turbine systems. This larger compressor volume adversely affects the surge margin of the gas turbine. Industrial acoustic sensors were placed near the compressor to identify when the equipment was getting close to the surge line. Fast Fourier transform (FFT) mathematical analysis was used to obtain spectra representing the probability density across the frequency range (0 - 5000 Hz). Comparison between FFT spectra for nominal and transient operations revealed that higher amplitude spikes were observed during incipient stall at three different frequencies, 900, 1020, and 1800 Hz. These frequencies were compared to the natural frequencies of the equipment and the frequency for the rotating turbomachinery to identify more general nature of the acoustic signal typical of the onset of compressor surge. The primary goal of this acoustic analysis was to establish an online methodology to monitor compressor stability that can be anticipated and avoided.

42 ENGINEERING↗

Increased isoprostane levels in oleic acid-induced lung injury

The present study was performed to examine a role of oxidative stress in oleic acid-induced lung injury model. Fifteen anesthetized sheep were ventilated and instrumented with a lung lymph fistula and vascular catheters for blood gas analysis and measurement of isoprostanes (8-epi prostaglandin F2{alpha}). Following stable baseline measurements, oleic acid (0.08 ml/kg) was administered and observed 4 h. Isoprostane was measured by gas chromatography mass spectrometry with the isotope dilution method. Isoprostane levels in plasma and lung lymph were significantly increased 2 h after oleic acid administration and then decreased at 4 h. The percent increases in isoprostane levels in plasma and lung lymph at 2 h were significantly correlated with deteriorated oxygenation at the same time point, respectively. These findings suggest that oxidative stress is involved in the pathogenesis of the pulmonary fat embolism-induced acute lung injury model in sheep and that the increase relates with the deteriorated oxygenation.

60 APPLIED LIFE SCIENCES↗

Differential thermal analysis and gas release studies of Apollo 11 samples.

The liquidus-solidus behavior of Apollo 11 lunar fines and the evolution characteristics of CO, nitrogen, He, Ne, and Ar were investigated by use of the combined techniques of high-vacuum differential thermal analysis (DTA) and mass spectrometry between 100 and 1500 C. The DTA thermogram has shown that the lunar fines undergo partial melting over a broad range of temperature from about 915 to 1300 C, with a significant initial melting of glassy and crystalline components within the fines at about 1140 C. The lunar material becomes a homogeneous melt at about 1300 C.

Wachi, F. M.↗

Harnessing Uncertainty through Functional Data Analysis in Gas Breakthrough Data

Detecting subsurface explosions from radionuclide gas migration through rock fractures is an effective way to identify nuclear activity. Los Alamos National Laboratory (LANL) has developed simulation methods, based on data from the 1962 Hardhat underground nuclear test, to predict gas breakthrough times at the surface. However, these methods rely on an imperfect understanding of the relationship between rock damage and fracture permeability. Our clinic project studies methods for predicting breakthrough curves that characterize total mass produced as a function of time, as well as quantifying the uncertainty associated with these predictions. The model that is currently employed to relate damage to permeability uses an empirically motivated power-law expression, with a range of parameter values that are compatible with the experimental Hardhat data. We develop emulators, built from functional data analysis techniques and trained on simulation data, that rapidly predict the gas breakthrough curve given a damage field and given the parameter values of the power-law equation. Using Bayesian regression, we address the problem of uncertainty quantification in our emulators. Finally, in order to test the robustness of the model, we further validate it on a damage field representing different physical conditions.

58 GEOSCIENCES↗

GAS MIXING ANALYSIS IN A LARGE-SCALED SALTSTONE FACILITY

Computational fluid dynamics (CFD) methods have been used to estimate the flow patterns mainly driven by temperature gradients inside vapor space in a large-scaled Saltstone vault facility at Savannah River site (SRS). The purpose of this work is to examine the gas motions inside the vapor space under the current vault configurations by taking a three-dimensional transient momentum-energy coupled approach for the vapor space domain of the vault. The modeling calculations were based on prototypic vault geometry and expected normal operating conditions as defined by Waste Solidification Engineering. The modeling analysis was focused on the air flow patterns near the ventilated corner zones of the vapor space inside the Saltstone vault. The turbulence behavior and natural convection mechanism used in the present model were benchmarked against the literature information and theoretical results. The verified model was applied to the Saltstone vault geometry for the transient assessment of the air flow patterns inside the vapor space of the vault region using the potential operating conditions. The baseline model considered two cases for the estimations of the flow patterns within the vapor space. One is the reference nominal case. The other is for the negative temperature gradient between the roof inner and top grout surface temperatures intended for the potential bounding condition. The flow patterns of the vapor space calculated by the CFD model demonstrate that the ambient air comes into the vapor space of the vault through the lower-end ventilation hole, and it gets heated up by the Benard-cell type circulation before leaving the vault via the higher-end ventilation hole. The calculated results are consistent with the literature information. Detailed results and the cases considered in the calculations will be discussed here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Considerations for damage analysis of gas turbine hot section components

The hot flowpath of a gas turbine engine contains static and rotating components operating in a very hostile environment. Since the reliable operation of these components is critical to the safe and efficient performance of the engine, structural life analysis of these members is carried out with great care. However, the complex nature of the strain-temperature-time cycle affecting the engine makes a general analysis procedure difficult and usually leads to separating the damage into regimes where one damage mode dominates. In particular, cycle dependent, time dependent, and thermomechanical fatigue regimes have been identified and some general considerations of each region are discussed. This discussion includes both the damage models themselves and the application of the models. Specific examples of several models are given and important factors affecting each are presented.

Cook, T. S.↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗