Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

$\gamma$-ray angular correlations, distributions and linear polarization in tracking arrays

With $\gamma $-ray tracking arrays, the angular correlation and, especially, the linear polarization of $\gamma $ rays can be measured with high precision. However, because of the complexity of these spectrometers, measuring angular distributions is more involved. The techniques and associated formalisms were developed and established in the 1950s. The experimental setups of that era were relatively simple when compared to the advanced $\gamma $-ray tracking arrays available today. This paper aims to review and refine these techniques, unify the nomenclatures and, specifically, adapt them for use with the newest tracking arrays. In addition, new methods for producing the required response functions for these arrays are introduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the CKM angle $\gamma $ in the ${{{B} ^0} \rightarrow {D} {{K} ^{*0}}}$ channel using self-conjugate ${D} \rightarrow {{K} ^0_{\textrm{S}}} h^+ h^-$ decays

A model-independent study of $C\!P$ violation in ${{B} ^0} \rightarrow {D} {{K} ^{*0}}$ decays is presented using data corresponding to an integrated luminosity of 9 fb -1 collected by the LHCb experiment at centre-of-mass energies of $\sqrt{s}=7, \, 8$ and 13 TeV. The CKM angle $\gamma$ is determined by examining the distributions of signal decays in phase-space bins of the self-conjugate ${D} \rightarrow {{K} ^0_{\textrm{S}}} h^+ h^-$ decays, where $h = \pi , K$. Observables related to $C\!P$ violation are measured and the angle $\gamma$ is determined to be $\gamma =(49^{+ 22}_{-19})^\circ$. Measurements of the amplitude ratio and strong-phase difference between the favoured and suppressed ${B} ^0$ decays are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of $Z \rightarrow ll\gamma$ decays at $\sqrt{s}$ = 8 TeV with the ATLAS detector

This paper presents a study of $Z \rightarrow ll\gamma$ decays with the ATLAS detector at the Large Hadron Collider. The analysis uses a proton–proton data sample corresponding to an integrated luminosity of 20.2 fb -1 collected at a centre-of-mass energy $\sqrt{s}$ = 8 TeV. Integrated fiducial cross-sections together with normalised differential fiducial cross-sections, sensitive to the kinematics of final-state QED radiation, are obtained. The results are found to be in agreement with state-of-the-art predictions for final-state QED radiation. First measurements of $Z \rightarrow ll\gamma\gamma$ decays are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray Spectrum Explanations (GRSE) v0.1

This code repository provides tools for producing various types of machine learning model explanations trained on gamma-ray spectra. It includes implementations of saliency mapping, Grad-CAM, LIME, and Kernel SHAP, including improvements and clarifications to some of the approaches that are specific to their use with gamma-ray spectral data. These tools are in support of the manuscript M.S. Bandstra et al., "Explaining machine-learning models for gamma-ray detection and identification," under review at PLOS ONE.

Bandstra, Mark↗

Gamma radiation sterilization of N95 respirators leads to decreased respirator performance

In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40–50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.

36 MATERIALS SCIENCE↗

Explaining machine-learning models for gamma-ray detection and identification

As more complex predictive models are used for gamma-ray spectral analysis, methods are needed to probe and understand their predictions and behavior. Recent work has begun to bring the latest techniques from the field of Explainable Artificial Intelligence (XAI) into the applications of gamma-ray spectroscopy, including the introduction of gradient-based methods like saliency mapping and Gradient-weighted Class Activation Mapping (Grad-CAM), and black box methods like Local Interpretable Model-agnostic Explanations (LIME) and SHapley Additive exPlanations (SHAP). In addition, new sources of synthetic radiological data are becoming available, and these new data sets present opportunities to train models using more data than ever before. In this work, we use a neural network model trained on synthetic NaI(Tl) urban search data to compare some of these explanation methods and identify modifications that need to be applied to adapt the methods to gamma-ray spectral data. We find that the black box methods LIME and SHAP are especially accurate in their results, and recommend SHAP since it requires little hyperparameter tuning. We also propose and demonstrate a technique for generating counterfactual explanations using orthogonal projections of LIME and SHAP explanations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The status of the galactic center gamma-ray excess

The Galactic Center Gamma-Ray Excess has a spectrum, angular distribution, and overall intensity that agree remarkably well with that expected from annihilating dark matter particles in the form of a m_X \sim m X ∼ 50 GeV thermal relic. Previous claims that these photons are clustered on small angular scales or trace the distribution of known stellar populations once appeared to favor interpretations in which this signal originates from a large population of unresolved millisecond pulsars. More recent work, however, has overturned these conclusions, finding that the observed gamma-ray excess does not contain discernible small scale power, and is distributed with approximate spherical symmetry, not tracing any known stellar populations. In light of these results, it now appears significantly more likely that the Galactic Center Gamma-Ray Excess is produced by annihilating dark matter.

Hooper, Dan↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

A Brief Introduction to Gamma and Neutron Radiation [Slides]

Objectives: Describe gamma rays in plain English; Give 3 reasons we measure gamma rays; Describe shielding effect vs gamma energy; List 4 components of the natural background; Detail the main reason we care about neutrons; and List three good neutron moderators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of GaN-Based Semiconductor Devices to Ion and Gamma Irradiation

GaN has electronic properties that make it an excellent material for the next generation of power electronics; however, its radiation hardening still needs further understanding before it is used in radiation environments. In this work we explored the response of commercial InGaN LEDs to two different radiation environments: ion and gamma irradiations. For ion irradiations we performed two types of irradiations at the Ion Beam Lab (IBL) at Sandia National Laboratories (SNL): high energy and end of range (EOR) irradiations. For gamma irradiations we fielded devices at the gamma irradiation facility (GIF) at SNL. The response of the LEDs to radiation was investigated by IV, light output and light output vs frequency measurements. We found that dose levels up to 500 krads do not degrade the electrical properties of the devices and that devices exposed to ion irradiations exhibit a linear and non- linear dependence with fluence for two different ranges of fluence levels. We also performed current injection annealing studies to explore the annealing properties of InGaN LEDs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculated Gamma Output from a 6-kilogram Sphere of Neptunium

We previously modeled a 6 kg neptunium sphere with pyDMTK 2.0.0b, a python-based intrinsic radiation (INRAD) modeling tool, on the MOONLIGHT machine. Here we report results from version 2.0.1b on SNOW, another TriLab Linux Capacity Cluster (TLCC) resource on the Laboratory’s Turquoise network. We also present gamma output from MCNP 6.2.0 in terms of discrete line strengths, full gamma spectra, and dose rate maps for visualization. Results from both models agree with recent gamma measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Shielding on Gamma Rays [Slides]

The interaction of gamma rays with matter results in an effect we call attenuation (i.e. ‘shielding’). Attenuation can dramatically alter the appearance of a spectrum. Attenuating materials may actually create features in a spectrum via x-ray fluorescence. Attenuation is a function of the incident gamma-ray, material properties, and the thickness of the material. Half Value Layers (HVL) are a useful concept for estimating how much a given thickness of material will impact transmission of gamma-rays. Shielding impacts spectra in predictable ways. We can use clues in the spectrum to infer information about the source’s local environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Independent Gamma Spectroscopy Analysis of a Plutonium Oxide Sample

Independent gamma spectroscopy data analysis of a plutonium oxide sample was requested on July 23, 2021. The primary request was to assess the Pu-239 activity/mass of the sample using previously collected gamma spectral data. Using the provided gamma spectral analysis report and spectral files, an independent evaluation of the data was conducted without any prior knowledge of the isotopic activity/mass of the sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Irradiation Facility

Gamma irradiation is a process that uses Cobalt60 radionuclide produced artificially in nuclear reactors to irradiate a variety of items using gamma radiation. A key characteristic of gamma irradiation is its high penetration capability and the fact that it can modify physical, chemical, and biological properties of the irradiated materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

The GammaSpec Package for Automated Gamma-ray Analysis (V.1.0)

This report describes the GammaSpec package, a tool developed to automate the analysis and comparison of gamma-ray spectra. The goal of this tool is to drastically reduce, or even eliminate, currently time consuming processes for comparing large sets of gamma-ray measurements. There are a number of potential applications for this work throughout the laboratory, but particularly within Global Security. Current work flows where large numbers of measured spectra must be compared for anomolies and outliers often consist of loading and visually inspecting individual spectra, or utilizing small-batch tools. One such example is the PeakEasy tool also developed at LANL. PeakEasy has a robust and tested feature set for calibrating, identifying, and fitting gamma-ray spectra. However it’s intention was not for batch processing and automated comparison of large numbers of spectra. This tool is not intended to replace PeakEasy in an analyzers arsenal, but to instead augment it. The intention here is to automate the isolation of spectra of particular interest, which can then be studied in further detail. This report is arranged as follows. Section 2 lays out the design goals and desired functionality of the package. Section 3 describes the algorithms developed and chosen to accomplish those goals. Section 4 describes the primary interaction with the tool, as well as it’s resulting output. Following these sections, results are presented from a set of example datasets from High Purity Germanium (HPGe) detectors in Sec. 5. Finally, the current status is summarized in Sec. 6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beta-Gamma Data Viewer v2.2.34 User's Manual

This document provides an overview, and procedures, for operating the beta-gamma data viewer for 7 regions of interest (7 ROI) data. The Beta-Gamma 7 ROI Data Viewer is a set of software tools that allow for viewing and analysis of IMS 2.0 Pulse Height Data (PHD) / Pulse Beta Gamma (PBG) files, state of health (SoH) files, and event log files. This is an upgrade from previous release of the tool that includes calibration tools.

97 MATHEMATICS AND COMPUTING↗