Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Observations of Coherent Optical Transition Radiation Interference Fringes Generated by Laser Plasma Accelerator Electron Beamlets

We report initial observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched electrons from laser-driven plasma accelerators (LPAs). These are revealed in the angular distribution patterns obtained by a CCD camera with the optics focused at infinity, or the far-field, viewing a Wartski two-foil interferometer. The beam divergences deduced by comparison to results from an analytical model are sub-mrad, and they are smaller than the ensemble vertical beam divergences measured at the downstream screen of the electron spectrometer. The transverse sizes of the beamlet images were obtained with focus at the object, or near field, and were in the few-micron regime as reported by LaBerge et al. [8]. The enhancements in intensity are significant relative to incoherent optical transition radiation (OTR) enabling multiple cameras to view each shot. We present two-foil interferometry effects coherently enhanced in both the 100-TW LPA at 215 MeV energy at Helmholtz-Zentrum Dresden-Rossendorf and the PW LPA at 1.0-GeV energy at the University of Texas-Austin. A transverse emittance estimate is reported for a microbunched beamlet example generated within the plasma bubble.

43 PARTICLE ACCELERATORS↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

High-speed three-dimensional shape measurement using geometry-constraint-based number-theoretical phase unwrapping

In this study, we propose a high-speed three-dimensional (3-D) shape measurement technique for dynamic scenes using geometry-constraint-based number-theoretical phase unwrapping. As a classical algorithm for temporal phase unwrapping (TPU), the number-theoretical approach is suitable for the binary defocusing fringe projection system since it can retrieve an absolute phase without using low-frequency fringe patterns. However, the conventional number-theoretical TPU approach cannot provide sufficient stability to unwrap a high-frequency phase since it requires the two fringe frequencies to be coprime within the global range of the projector coordinate. In contrast, using low-frequency fringe patterns tends to make phase unwrapping more reliable, but at the expense of the measurement precision. By introducing depth constraint into the traditional number-theoretical TPU, we only need to eliminate the phase ambiguity of each pixel within a small period range defined by the depth range, which means that our method just requires the two fringe frequencies to be coprime within the local period range instead of the conventional global range. Due to the reduction of fringe order candidates and the unambiguous phase range, the reliability of phase unwrapping can be significantly improved compared with the traditional number-theoretical TPU approach even when high-frequency fringe patterns are used. The proposed method has been successfully implemented on a high-frame-rate fringe projection system, achieving high-precision, robust, and absolute 3-D shape measurement at 3333 frames per second.

42 ENGINEERING↗

Analysis of coseismic surface displacement gradients using radar interferometry: New insights into the Landers earthquake

The map of the coseismic displacement field generated by interferometric processing of synthetic aperture radar (SAR) images taken before and after the June 28, 1992, Landers earthquake sequence brings new insights into the nature of deformation caused by these earthquakes. We use the interferometric map generated by Massonnet et al. (1993) to analyze the surface displacement field in the vicinity of the fault trace. Complexities in the fringe pattern near the fault reflect short-wavelength variations of the surface rupture and slip distribution, and attest to large displacement gradients. Along two sections of the fault, characteristic fringe patterns can be recognized, contrasting in density and direction with patterns observed away from the rupture. In order to understand the observed fringe patterns, we compute synthetic interferograms in three simple cases: (1) rigid-body rotations about a vertical axis, (2) about a horizontal axis (tilt), and (3) distributed, simple shear. The orientation and spatial separation of interferometric fringes predicted by these models help constrain near-field deformation and rupture parameters. Where the Kickapoo fault connects with the Homestead Valley fault, the interferogram shows a clear pattern of parallel N20 deg W fringes separated by about 160 m. This pattern and vertical offsets measured along the Kickapoo fault suggest that the block between this fault and the Johnson Valley fault may have been tilted, down to the west. A 5-km block lifted by 1 m on one side would be tilted by an angle of 0.01 deg (190 microrad), producing fringes separated by about 160 m, parallel to the tilt axis. Such a tilt, parallel to a N20 deg W direction, would account for the gradual, northward increase of the vertical slip component observed along the Kickapoo fault. This tilt may also explain the 1 m of reverse slip observed along the 'slip gap' section of the Homestead Valley break. Between the southern end of the Johnson Valley fault and the Eureka Peak fault, where no surface rupture has been mapped, the dense pattern of fringes implies distributed shear, probably resulting from fault slip at depth. The density and direction of the fringes in the gap are consistent with a right-lateral slip of 1.2-3.8 m on a blind fault locked above the depth of 1.5-2 km. Such observations of small wavelength features in the SAR interferogram bring new insights into the near-field displacement gradient and thus on response of the uppermost crust to seismic rupture.

Peltzer, Gilles↗

Edge Triggered Apparatus and Method for Measuring Strain in Bragg Gratings

An apparatus and method for measuring strain of gratings written into an optical fiber. Optical radiation is transmitted over one or more contiguous predetermined wavelength ranges into a reference optical fiber network and an optical fiber network under test to produce a plurality of reference interference fringes and measurement interference fringes, respectively. The reference and measurement fringes are detected, and the reference fringes trigger the sampling of the measurement fringes. This results in the measurement fringes being sampled at 2(pi) increments of the reference fringes. Each sampled measurement fringe of each wavelength sweep is transformed into a spatial domain waveform. The spatial domain waveforms are summed to form a summation spatial domain waveform that is used to determine location of each grating with respect to a reference reflector. A portion of each spatial domain waveform that corresponds to a particular grating is determined and transformed into a corresponding frequency spectrum representation. The strain on the grating at each wavelength of optical radiation is determined by determining the difference between the current wavelength and an earlier, zero-strain wavelength measurement.

Froggatt, Mark E.↗

A method of analyzing holographic interferograms of ballistic models in hypersonic free-flight

The objective of this research was to develop a method to extract integrated flowfield density information from finite-fringe interferograms produced with a laser holographic interferometer. This method was applied to two sets of holograms. An aeroassist flight experiment model flown in a mixture of 50 percent air - 50 percent argon and a blunt slender cone flown in air were flown at Mach 14.5 into freestream static pressures of 0.04 and 0.08 atm, respectively. The method of analysis can be separated into two main divisions. The first step is to identify fringes inside the wake in terms of the fringes in the freestream. This is important because refraction effects have obscured the region near the shock such that fringes cannot be followed into the wake region. The second step is to extrapolate the freestream fringes into the wake to determine the location of disturbance-related fringe shifts. Coupled with assumptions about the shape of the wake region, the locations of the disturbance-related fringe shifts can be related to the integrated density.

Kieffer, Douglas L.↗

Measurement of the Specific Refractivities of CF4 and C2F6

In order to relate the measured fringe shift of an interferometer to density, the relation between density rho and refractive index n must be known. For gases where the refractive index is close to unity, this relation between density and refractive index is very closely approximated by (n - 1) = K rho where K is the specific refractivity, or the Gladstone-Dale constant. The specific refractivity, which is weakly dependent on wavelength and temperature, is readily available for a number of common test gases such as N2 and air. For more unique test gases such as CF4 and C2F6 for which refractive index data at optical wavelengths is not readily available, the constants can be estimated from the atomic refractivities of carbon and fluorine. In order to verify this estimation, a two-beam interferometer was used to experimentally determine the specific refractivities of CF4 and C2F6. This data was required for holographic interferometric measurements made at the Langley Hypersonic CF4 Tunnel. A Twyman-Green interferometer with a He-Ne laser light source of vacuum wavelength lambda equal to 633 nm was used to measure the constants. One beam of the two-beam interferometer passed through an optical cell of known inside length l which could be evacuated and slowly filled with the test gas to a density of 7.2 kg/cu m for CF4 or 5.7 kg/cu m for C2F6. If the refractive index (and hence density) is constant along the optical path through the cell, the fringe shift M and density change Delta rho are related M = 2Kl Delta rho/lambda for the double pass interferometer. Thus K can be determined by measuring the fringe shift as the density is changed. The output of a photodiode used to detect the fringe shift was recorded on a strip chart recorder. The rate of pressure increase of the test gas in the cell was controlled such that the fringes shifted at a rate of 0.5 to 1 fringe per sec. The pressure in the test cell was measured with a high accuracy quartz crystal pressure transducer and recorded approximately every 20 fringe peaks. The temperature of the cell was measured with a thermocouple and recorded at the start, midpoint, and end of each test.

Burner, A. W.↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

AC Resistance Reduction Using Orthogonal Air Gaps in High-Frequency Inductors: Preprint

This paper presents a relatively simple technique to reduce winding losses due to fringing fields in high-frequency inductors. In high-frequency power electronics, ac inductor winding losses are affected by skin and proximity effects, including uneven current distribution due to fringing magnetic fields around airgaps. It is well known how fringing effects can be mitigated using distributed airgaps, at the expense of non-standard core or winding geometry. In planar magnetics, the orthogonal-airgap approach proposed in this paper combines airgaps in core segments parallel with the windings with conventionally placed airgaps in segments perpendicular to the windings. The approach is developed using a 1D analytical framework and validated by 2D finite-element simulations. Analytical guidelines are presented to optimize the airgaps to achieve minimum ac resistance. As a case study, a planar inductor is designed for an 8~kW SiC-based buck converter operating at 250~kHz. It is shown how the orthogonal airgaps result in more than 45\% reduction in ac resistance and substantially reduced inductor losses compared to the design using standard airgaps. The results are verified by loss measurements on an experimental converter prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reestablishing larval connectivity in an estuarine landscape: the importance of shoreline and subtidal oysters ( Crassostrea virginica ) in a comprehensive oyster restoration program

The decline of oyster reefs in estuaries has resulted from a combination of chronic and acute disturbances. The loss has resulted in decreased yield for the oyster fishery as well as a decline in ecological benefits that has led to increased efforts to restore oyster reefs. The need for scientific guidance in accomplishing these restoration goals has become even more pressing in the northcentral Gulf of Mexico in the wake of injury to oyster reefs resulting from the Deepwater Horizon oil spill. Restoration of both the shallow, marsh-fringing oyster aggregations and the deeper subtidal oyster reefs is necessary. Historically, fringing oysters have been overlooked in the oyster habitat landscape because of their limited commercial value. Here, we use a biophysical transport model to examine the transport and settlement of oyster larvae in known oyster reefs along the coast of the northcentral Gulf of Mexico. The modeling demonstrated that the majority of oyster larvae settle within the embayment (>98%) or sub-basin (>65%) of their origin. Additionally, the model demonstrated the importance of fringing oysters as a source of larvae to re-seed other fringing oysters along marsh edges as well as subtidal oyster reefs. We conclude that networks of reefs, including both fringing oyster habitat and subtidal oyster reefs within sub-basins, are necessary to provide resilience to the population at the sub-basin level. Finally, we conclude that fringing oyster habitat may serve as an archipelago-like network to enhance larval supply and connectivity for oysters throughout the mesosaline portions of estuaries.

ADCIRC↗

Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac

Purpose: Linac-magnetic resonance (MR) systems have been proposed in order to achieve real-time image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. Methods: The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. Results: The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak intensity was observed. Despite these changes, the target phase space had little effect on the depth dose curves or dose profiles calculated for a 40x40 cm{sup 2} field at 1.5 cm depth. At longitudinal fields larger than 0.012 T, a drastic reduction in the injection current from the electron gun was observed due to a large fraction of electrons striking the anode. This further reduced the target current, which reached a minimum of 28{+-}2 mA at 0.06 T. A slow increase in the injection and target currents was observed at fields larger than 0.06 T due to greater beam collimation in the anode beam tube. Conclusions: In an effort to achieve higher quality images and a reduction in hot and cold spots in the treatment plan, a parallel configuration linac-MR system is presented. The longitudinal magnetic fields of the MR imager caused large beam losses within the electron gun. These losses may be eliminated through a redesign of the electron gun optics incorporating a longitudinal magnetic field, or through magnetic shielding, which has already been proven successful for the transverse configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

Apparatus and Method for Measuring Strain in Bragg Gratings

An apparatus and method for measuring strain of gratings written into an optical fiber is disclosed. Optical radiation is transmitted over a plurality of contiguous predetermined wavelength ranges into a reference optical fiber network and an optical fiber network under test to produce a plurality of reference interference fringes and measurement interference fringes. respectively. The reference and measurement fringes are detected and sampled such that each sampled value of the reference and measurement fringes is associated with a corresponding sample number. The wavelength change of the reference optical fiber, for each sample number, due to the wavelength of the optical radiation is determined. Each determined wavelength change is matched with a corresponding sampled value of each measurement fringe. Each sampled measurement fringe of each wavelength sweep is transformed into a spatial domain waveform. The spatial domain waveforms are summed to form a summation spatial domain waveform that is used to determine location of each grating with respect to a reference reflector. A portion of each spatial domain waveform that corresponds to a particular grating is determined and transformed into a corresponding frequency spectrum representation. The strain on the grating at each wavelength of optical radiation is determined by determining the difference between the current wavelength and an earlier, zero-strain wavelength measurement.

Froggatt, Mark E.↗

Particle measurement systems and methods

A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.

47 OTHER INSTRUMENTATION↗