An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

The Transference Number

The performance of rechargeable batteries and other electrochemical systems depends on the rate at which the working ion (often a cation) is transported from one electrode to the other. The cation transference number is an important transport parameter that affects this rate. The purpose of this perspective is to distinguish between approximate and rigorous methods used in the literature to measure the transference number. We emphasize the fact that this parameter is dependent on the reference frame used in the analysis; care must be taken when comparing values obtained from different sources to account for differences in reference frames. We present data obtained from a well‐characterized electrolyte. We compare rigorously determined transference numbers in two reference frames with values obtained by an approximate method. We conclude with a qualitative discussion of the relationship between the transference number and salt concentration gradients that are obtained when current is drawn through a battery.

Gao, Kevin W.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Z-boson production in p-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 8.16 TeV and Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5.02 TeV

Measurement of Z-boson production in p-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 8 . 16 TeV and Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}} $ = 5 . 02 TeV is reported. It is performed in the dimuon decay channel, through the detection of muons with pseudorapidity - 4 < η μ < - 2 . 5 and transverse momentum $ {p}_{\mathrm{T}}^{\mu } $ > 20 GeV/ c in the laboratory frame. The invariant yield and nuclear modification factor are measured for opposite-sign dimuons with invariant mass 60 < m μμ < 120 GeV/ c 2 and rapidity 2 . 5 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < 4. They are presented as a function of rapidity and, for the Pb-Pb collisions, of centrality as well. The results are compared with theoretical calculations, both with and without nuclear modifications to the Parton Distribution Functions (PDFs). In p-Pb collisions the center-of-mass frame is boosted with respect to the laboratory frame, and the measurements cover the backward ( - 4 . 46 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < - 2 . 96) and forward (2 . 03 < $ {y}_{\mathrm{cms}}^{\mu \mu} $ < 3 . 53) rapidity regions. For the p-Pb collisions, the results are consistent within experimental and theoretical uncertainties with calculations that include both free-nucleon and nuclear-modified PDFs. For the Pb-Pb collisions, a 3 . 4 σ deviation is seen in the integrated yield between the data and calculations based on the free-nucleon PDFs, while good agreement is found once nuclear modifications are considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Cartesian-diffusion Langevin method for hybrid kinetic-fluid Coulomb scattering in particle-in-cell plasma simulations

A novel, drag-diffusion Langevin method of hybrid, kinetic-fluid Coulomb scattering in plasmas is presented. Unlike previous methods, the frictional drag is always applied in the simulation frame of reference. The velocity-space diffusion is performed in the stationary-fluid frame of reference when anisotropic, and in the laboratory frame when isotropic. While the general method is mass-ratio independent, we focus on interactions of kinetic-ions and fluid-electrons to show first-order modifications to the electron velocity distribution function that are an important correction for the accurate calculation of electric resistivity. Inclusion of sub-cycling and a limit to the maximum collision frequency is shown to allow for arbitrarily large timesteps without numerical failure. Here the Langevin method is compared with a grid-based binary method and found to require a much less restrictive timestep in cases of ion–electron slowing and temperature equilibration; this finding differs from previous work and is dependent on the mass ratio.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

42 ENGINEERING↗

Reprint of: Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

47 OTHER INSTRUMENTATION↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Heterogeneous Corrosion Pathways in Pt–Ni Nanododecahedra Revealed by In Situ Liquid Cell TEM

Unraveling nanoscale corrosion pathways is essential for understanding materials degradation mechanisms and designing corrosion-resistant metal alloys. Here, in this study, we directly visualize the corrosion of Pt–Ni nanododecahedra in 0.1 M HCl using liquid cell TEM. Each nanoparticle features a Ni-rich core and a Pt-rich frame. Our observation reveals that corrosion proceeds in two distinct stages: first the Ni-rich core dissolves without forming porosity, yielding small Pt nanocrystals and transient NiCl 2 ·6H 2 O at the retreating interfaces; then the Pt-rich frame fragments into ∼5 nm Pt 3 Ni nanocrystals that subsequently dissolve uniformly, accompanied by fleeting Pt chlorides. A percolation-based theory explains the observed behaviors: The core’s ∼8% Pt lies below the Pt connectivity threshold, preventing Pt scaffold formation, whereas the frame’s 48% Ni exceeds the Ni percolation threshold and collapses. Ordered Pt 3 Ni suppresses Ni percolation, thereby enforcing uniform dissolution. These findings reveal how composition and structural ordering govern heterogeneous corrosion in Pt–Ni architectured nanoparticles.

Liquid phase TEM↗

Parameters of the Lightning Attachment Processes in a Negative Cloud-To-Ground Stroke Observed on a Microsecond Timescale

We present time-correlated ultra-high-speed video camera and electromagnetic field measurements of the attachment processes in a natural negative cloud-to-ground stroke. The video camera frame exposure time and pixel resolution were 740 ns and 0.91 m/pixel, respectively. The common streamer zone (CSZ) was first observed 2.52 µs preceding the first frame showing the return stroke (RS) in progress, when the upward and downward leader-tips were 9.8 m apart. In the next frame, the two leaders were observed to have propagated toward each other within the CSZ, with their tips being 0.91 m apart. Our observations show with unprecedented precision/clarity that (a) the slow front in the field waveform is associated with the CSZ, and (b) the “proper” start of the RS is marked by the onset of the fast transition in the field waveform which occurs at the completion of the attachment processes (when the upward and downward leaders have merged).

54 ENVIRONMENTAL SCIENCES↗

Coherent correlation imaging for resolving fluctuating states of matter

Fluctuations and stochastic transitions are ubiquitous in nanometre-scale systems, especially in the presence of disorder. However, their direct observation has so far been impeded by a seemingly fundamental, signal-limited compromise between spatial and temporal resolution. Here we develop coherent correlation imaging (CCI) to overcome this dilemma. Our method begins by classifying recorded camera frames in Fourier space. Contrast and spatial resolution emerge by averaging selectively over same-state frames. Temporal resolution down to the acquisition time of a single frame arises independently from an exceptionally low misclassification rate, which we achieve by combining a correlation-based similarity metric with a modified, iterative hierarchical clustering algorithm. We apply CCI to study previously inaccessible magnetic fluctuations in a highly degenerate magnetic stripe domain state with nanometre-scale resolution. We uncover an intricate network of transitions between more than 30 discrete states. Our spatiotemporal data enable us to reconstruct the pinning energy landscape and to thereby explain the dynamics observed on a microscopic level. CCI massively expands the potential of emerging high-coherence X-ray sources and paves the way for addressing large fundamental questions such as the contribution of pinning and topology in phase transitions and the role of spin and charge order fluctuations in high-temperature superconductivity.

36 MATERIALS SCIENCE↗

Effect of Thomas Rotation on the Lorentz Transformation of Electromagnetic fields

A relativistic particle undergoing successive boosts which are non collinear will experience a rotation of its coordinate axes with respect to the boosted frame. This rotation of coordinate axes is caused by a relativistic phenomenon called Thomas Rotation. We assess the importance of Thomas rotation in the calculation of physical quantities like electromagnetic fields in the relativistic regime. We calculate the electromagnetic field tensor for general three dimensional successive boosts in the particle’s rest frame as well as the laboratory frame. We then compare the electromagnetic field tensors obtained by a direct boost β δβ → + → and successive boosts β → and Δβ → and check their consistency with Thomas rotation. This framework might be important to situations such as the calculation of frequency shifts for relativistic spin1/2 particles undergoing Larmor precession in electromagnetic fields with small field non-uniformities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

Multiplexed structured imaging of laser induced fluorescence at 10 GHz rate

The frame rate of conventional high-speed imaging devices is limited by exposure time and signal read-out time. Structured imaging is able to push the frame rate beyond the limit of the imaging device. This work demonstrates the feasibility of potential TeraHz rate structured imaging with a multiplexed structured imaging setup. In this work, a multiplexed structured image capture system was employed to image UV laser induced krypton-II emission lines at 10 GHz. The measured emission intensity of the 764 nm line over time suggests a temporal resolution of 97 ps. The temporal resolution is adjustable, and the frame rate can be further increased to the TeraHz level.

47 OTHER INSTRUMENTATION↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

Strategies for on-chip digital data compression for X-ray pixel detectors

Here, the continued desire for X-ray pixel detectors with higher frame rates will stress the ability of application-specific integrated circuit (ASIC) designers to provide sufficient off-chip bandwidth to reach continuous frame rates in the 1 MHz regime. To move from the current 10 kHz to the 1 MHz frame rate regime, ASIC designers will continue to pack as many power-hungry high-speed transceivers at the periphery of the ASIC as possible. In this paper, however, we present new strategies to make the most efficient use of the off-chip bandwidth by utilizing data compression schemes for X-ray photon-counting and charge-integrating pixel detectors. In particular, we describe a novel in-pixel compression scheme that converts from analog to digital converter units to encoded photon counts near the photon Poisson noise level and achieves a compression ratio of >1.5x independent of the dataset. In addition, we describe a simple yet efficient zero-suppression compression scheme called "zeromask" (ZM) located at the ASIC's edge before streaming data off the ASIC chip. ZM achieves average compression ratios of >4x, >7x, and >8x for high-energy X-ray diffraction, ptychography, and X-ray photon correlation spectroscopy datasets, respectively. We present the conceptual designs, register-transfer level block diagrams, and the physical ASIC implementation of these compression schemes in 65 nm CMOS. When combined, these two digital compression schemes could increase the effective off-chip bandwidth by a factor of 6-12x.

47 OTHER INSTRUMENTATION↗

Linear analysis of the Kelvin–Helmholtz instability in relativistic magnetized symmetric flows

ABSTRACT We study the linear stability of a planar interface separating two fluids in relative motion, focusing on the symmetric configuration where the two fluids have the same properties (density, temperature, magnetic field strength, and direction). We consider the most general case with arbitrary sound speed cs, Alfvén speed vA, and magnetic field orientation. For the instability associated with the fast mode, we find that the lower bound of unstable shear velocities is set by the requirement that the projection of the velocity on to the fluid-frame wavevector is larger than the projection of the Alfvén speed on to the same direction, i.e. shear should overcome the effect of magnetic tension. In the frame where the two fluids move in opposite directions with equal speed v, the upper bound of unstable velocities corresponds to an effective relativistic Mach number $M_{\rm re}\equiv v/v_{\rm {f}\perp }\sqrt{(1-v_{\rm {f}\perp }^2)/(1-v^2)} \cos \theta =\sqrt{2}$, where $v_{\rm {f}\perp }=[v_{\rm {A}}^2+c_{\rm s}^2(1-v_{\rm {A}}^2)]^{1/2}$ is the fast speed assuming a magnetic field perpendicular to the wavevector (here, all velocities are in units of the speed of light), and θ is the laboratory-frame angle between the flow velocity and the wavevector projection on to the shear interface. Our results have implications for shear flows in the magnetospheres of neutron stars and black holes – both for single objects and for merging binaries – where the Alfvén speed may approach the speed of light.

Astronomy & Astrophysics↗