Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design and experimental study of a secondary hohlraum radiation source with laser focal spots blocked

A design of secondary hohlraum radiation source with laser focal spots blocked is introduced. The hard x-ray radiation such as the gold M-band emission and hot electrons from the coronal plasma were designed to be shielded using a cylindrical shield. Three-dimensional view factor analysis was carried out to optimize the shield structure to achieve higher radiation temperature. An experiment was performed at Shenguang III prototype laser facility to verify the design. Velocity Interferometer System for Any Reflector was used to measure the shock wave speed in a three-stepped Al sample driven by this radiation source and the peak radiation temperature of the radiation source was estimated to be about 90 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Focal overlap gating in velocity map imaging to achieve high signal-to-noise ratio in photo-ion pump-probe experiments

We demonstrate a technique in velocity map imaging (VMI) that allows spatial gating of the laser focal overlap region in time resolved pump-probe experiments. This significantly enhances signal-to-noise ratio by eliminating background signal arising outside the region of spatial overlap of pump and probe beams. This enhancement is achieved by tilting the laser beams with respect to the surface of the VMI electrodes which creates a gradient in flight time for particles born at different points along the beam. By suitably pulsing our microchannel plate detector, we can select particles born only where the laser beams overlap. Furthermore, this spatial gating in velocity map imaging can benefit nearly all photo-ion pump-probe VMI experiments especially when extreme-ultraviolet light or X-rays are involved which produce large background signals on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the 2-methylvinoxy radical + O 2 reaction: A focal point analysis and composite multireference study

Vinoxy radicals are involved in numerous atmospheric and combustion mechanisms. High-level theoretical methods have recently shed new light on the reaction of the unsubstituted vinoxy radical with O 2 . The reactions of 1-methylvinoxy radical and 2-methylvinoxy radical with molecular oxygen have experimental high pressure limiting rate constants, k ∞ , 5–7 times higher than that of the vinoxy plus O 2 reaction. In this work, high-level ab initio quantum chemical computations are applied to the 2-methylvinoxy radical plus O 2 system, namely, the formation and isomerization of the 1-oxo-2-propylperoxy radical, the immediate product of O 2 addition to the 2-methylvinoxy radical. Multireference methods were applied to the entrance channel. No barrier to O 2 addition could be located, and more sophisticated treatment of dynamic electron correlation shows that the principal difference between O 2 addition to the vinoxy and 2-methylvinoxy radicals is a larger steric factor for 2-methylvinoxy + O 2 . This is attributed to the favorable interaction between the incoming O 2 molecule and the methyl group of the 2-methylvinoxy radical. Via the focal point approach, energetics for this reaction were determined, in most cases, to chemical accuracy. The coupled-cluster singles, doubles, and perturbative triples [CCSD(T)] correlation energy and Hartree–Fock energies were independently extrapolated to the complete basis set limit. A correction for the effect of higher excitations was computed at the CCSDT(Q)/6-31G level. Corrections for the frozen-core approximation, the Born–Oppenheimer approximation, the nonrelativistic approximation, and the zero-point vibrational energy were included. From the 1-oxo-2-propylperoxy radical, dissociation to reactants is competitive with the lowest energy isomerization pathway. The lowest energy isomerization pathway ultimately forms acetaldehyde, CO, and ·OH as the final products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗

High-precision method for determining the position of laser beam focal plane

The method of wavefront doubled-frequency spherical modulation for determining the laser beam waist position has been simulated and experimentally studied. The error in determining the focal plane position is less than 10{sup -5} D. The amplitude of the control doubled-frequency electric signal is experimentally found to correspond to 12% of the total radiation power. (laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FOCAL PLANE WAVEFRONT SENSING USING RESIDUAL ADAPTIVE OPTICS SPECKLES

Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance the Strehl ratio or suppress the residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the science camera is essential for determining the DM shape that compensates for any non-common-path (NCP) wavefront errors. Using DM displacement ripples to create a series of probe and anti-halo speckles in the focal plane has been proposed for space-based coronagraphs and successfully demonstrated in the lab. We present the theory and first on-sky demonstration of a technique to measure the complex halo using the rapidly changing residual atmospheric speckles at the 6.5 m MMT telescope using the Clio mid-IR camera. The AO system's wavefront sensor measurements are used to estimate the residual wavefront, allowing us to approximately compute the rapidly evolving phase and amplitude of speckle halo. When combined with relatively short, synchronized science camera images, the complex speckle estimates can be used to interferometrically analyze the images, leading to an estimate of the static diffraction halo with NCP effects included. In an operational system, this information could be collected continuously and used to iteratively correct quasi-static NCP errors or suppress imperfect coronagraphic halos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE IMAGING PROPERTIES OF THE GAS PIXEL DETECTOR AS A FOCAL PLANE POLARIMETER

X-rays are particularly suited to probing the physics of extreme objects. However, despite the enormous improvements of X-ray astronomy in imaging, spectroscopy, and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as a candidate instrument to fill the gap created by more than 30 yr without measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time, and the polarization angle of every single photon, it allows us to perform polarimetry of subsets of data singled out from the spectrum, the light curve, or an image of the source. The GPD has an intrinsic, very fine imaging capability, and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray testing facility of the Max-Planck-Institut für extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it with a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like pulsar wind nebulae and supernova remnants as case studies for the XIPE configuration and also discuss possible improvements by coupling the detector with advanced optics that have a finer angular resolution and larger effective areas to study extended objects with more detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Photometry, Centroid and Point-spread Function Measurements in the LSST Camera Focal Plane Using Artificial Stars

Abstract The Vera C. Rubin Observatory’s LSST Camera (LSSTCam) pixel response has been characterized using laboratory measurements with a grid of artificial stars. We quantify the contributions to photometry, centroid, point-spread function size, and shape measurement errors due to small anomalies in the LSSTCam CCDs. The main sources of those anomalies are quantum efficiency variations and pixel area variations induced by the amplifier segmentation boundaries and “tree-rings”—circular variations in silicon doping concentration. This laboratory study using artificial stars projected on the sensors shows overall small effects. The residual effects on point-spread function (PSF) size and shape are below 0.1%, meeting the ten-year LSST survey science requirements. However, the CCD mid-line presents distortions that can have a moderate impact on PSF measurements. This feature can be avoided by masking the affected regions. Effects of tree-rings are observed on centroids and PSFs of the artificial stars and the nature of the effect is confirmed by a study of the flat-field response. Nevertheless, further studies of the full-focal plane with stellar data should more completely probe variations and might reveal new features, e.g., wavelength-dependent effects. The results of this study can be used as a guide for the on-sky operation of LSSTCam.

79 ASTRONOMY AND ASTROPHYSICS↗

Results from the FOCAL Experiment Campaign 1: Turbine Control Co-Design

This paper summarizes the scaling approach and results from the first experimental campaign of the Floating Offshore-wind and Controls Advanced Laboratory (FOCAL) Experimental Program, which is focused on developing public data sets to support the validation of numerical models for floating wind control co-design. A 1:70 Froude-scale performance-matched model of the IEA Wind 15-MW reference turbine was designed, built, and characterized on a fixed base. The National Renewable Energy Laboratory's Reference Open-Source COntroller (ROSCO) was integrated into the scale testing to examine the impact advanced turbine and generator control strategies have on turbine performance and loads, enabling validation of control strategies for floating wind design optimization.

17 WIND ENERGY↗

MONACO: accurate biological network alignment through optimal neighborhood matching between focal nodes

Motivation: Alignment of protein–protein interaction networks can be used for the unsupervised prediction of functional modules, such as protein complexes and signaling pathways, that are conserved across different species. To date, various algorithms have been proposed for biological network alignment, many of which attempt to incorporate topological similarity between the networks into the alignment process with the goal of constructing accurate and biologically meaningful alignments. Especially, random walk models have been shown to be effective for quantifying the global topological relatedness between nodes that belong to different networks by diffusing node-level similarity along the interaction edges. However, these schemes are not ideal for capturing the local topological similarity between nodes. Results: Here, we propose MONACO, a novel and versatile network alignment algorithm that finds highly accurate pairwise and multiple network alignments through the iterative optimal matching of ‘local’ neighborhoods around focal nodes. Extensive performance assessment based on real networks as well as synthetic networks, for which the ground truth is known, demonstrates that MONACO clearly and consistently outperforms all other state-of-the-art network alignment algorithms that we have tested, in terms of accuracy, coherence and topological quality of the aligned network regions. Furthermore, despite the sharply enhanced alignment accuracy, MONACO remains computationally efficient and it scales well with increasing size and number of networks.

97 MATHEMATICS AND COMPUTING↗

Loss of spatial coherence and limiting of focal plane intensity by small-scale laser-beam filamentation

We describe a nonlinear optical mechanism that leads to a decrease of the degree of (transverse) spatial coherence of a laser beam as a function of propagation distance. This prediction is in direct contrast with those of the van Cittert-Zernike theorem, which applies to propagation through a linear, homogeneous material. The mechanism by which coherence is lost is the growth of small phase irregularities initially present on the laser wave front. We develop a detailed theoretical model of this effect and present experimental results that validate this model. The practical importance of this result is that by being able to controllably decrease the spatial coherence of a laser beam, one can limit the maximum intensity that is produced in its focal region. By limiting the intensity, one can prevent laser damage to bulk optical components or to sensitive photodetectors. This mechanism thus provides an alternative to current approaches of sensor protection based on optical power limiting.

74 ATOMIC AND MOLECULAR PHYSICS↗

Stability Boundaries of Discharges Generated in the Focal Region of a CW Microwave Beam

Plasma was generated in the focal region of a multikilowatt, 4.7-GHz continuous-wave (CW) microwave beam far removed from the walls of the vacuum chamber, minimizing the nonideal effects associated with plasma-wall and beam-wall interactions. Experiments were conducted with gas mixtures of argon, nitrogen, and oxygen at gas pressures ranging from 100 to 200 mtorr. Furthermore, three types of discharges were observed during these experiments: unstable, quasi-stable, and stable discharges. It was determined that the stability of the discharges could be controlled through adjustments of the gas composition, gas pressure, and power of the microwave beam. This article reports on the operational conditions in which stable discharges were achieved and the general behavior of these discharges as the control parameters were varied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-tank, on-shot characterization of the OMEGA laser system focal spot

Direct-drive fusion implosion experiments using the 60-beam OMEGA Laser System require ~1% rms uniformity on target. Measurements from laser diagnostics indicate that beam-to-beam power variation has been sufficiently reduced such that the uniformity nearly meets this requirement; however, experimental results suggest otherwise. To better understand this discrepancy, a full-beam-in-tank diagnostic has been developed to characterize the on-shot, full-energy focal spot of a single beam inside the target chamber using a small sample of the beam from the final optic assembly. In this paper, we describe the diagnostic and present the results of commissioning experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields

Purpose: A close proximity hybrid x-ray/magnetic resonance (XMR) imaging system offers several critical advantages over current XMR system installations that have large separation distances (∼5 m) between the imaging fields of view. The two imaging systems can be placed in close proximity to each other if an x-ray tube can be designed to be immune to the magnetic fringe fields outside of the MR bore. One of the major obstacles to robust x-ray tube design is correcting for the effects of the MR fringe field on the x-ray tube focal spot. Any fringe field component orthogonal to the x-ray tube electric field leads to electron drift altering the path of the electron trajectories. Methods: The method proposed in this study to correct for the electron drift utilizes an external electric field in the direction of the drift. The electric field is created using two electrodes that are positioned adjacent to the cathode. These electrodes are biased with positive and negative potential differences relative to the cathode. The design of the focusing cup assembly is constrained primarily by the strength of the MR fringe field and high voltage standoff distances between the anode, cathode, and the bias electrodes. From these constraints, a focusing cup design suitable for the close proximity XMR system geometry is derived, and a finite element model of this focusing cup geometry is simulated to demonstrate efficacy. A Monte Carlo simulation is performed to determine any effects of the modified focusing cup design on the output x-ray energy spectrum. Results: An orthogonal fringe field magnitude of 65 mT can be compensated for using bias voltages of +15 and −20 kV. These bias voltages are not sufficient to completely correct for larger orthogonal field magnitudes. Using active shielding coils in combination with the bias electrodes provides complete correction at an orthogonal field magnitude of 88.1 mT. Introducing small fields (<10 mT) parallel to the x-ray tube electric field in addition to the orthogonal field does not affect the electrostatic correction technique. However, rotation of the x-ray tube by 30° toward the MR bore increases the parallel magnetic field magnitude (∼72 mT). The presence of this larger parallel field along with the orthogonal field leads to incomplete correction. Monte Carlo simulations demonstrate that the mean energy of the x-ray spectrum is not noticeably affected by the electrostatic correction, but the output flux is reduced by 7.5%. Conclusions: The maximum orthogonal magnetic field magnitude that can be compensated for using the proposed design is 65 mT. Larger orthogonal field magnitudes cannot be completely compensated for because a pure electrostatic approach is limited by the dielectric strength of the vacuum inside the x-ray tube insert. The electrostatic approach also suffers from limitations when there are strong magnetic fields in both the orthogonal and parallel directions because the electrons prefer to stay aligned with the parallel magnetic field. These challenging field conditions can be addressed by using a hybrid correction approach that utilizes both active shielding coils and biasing electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time resolved photo-luminescent decay characterization of mercury cadmium telluride focal plane arrays

The minority carrier lifetime is a measurable material property that is an indication of infrared detector device performance. To study the utility of measuring the carrier lifetime, an experiment has been constructed that can time resolve the photo-luminescent decay of a detector or wafer sample housed inside a liquid nitrogen cooled Dewar. Motorized stages allow the measurement to be scanned over the sample surface, and spatial resolutions as low as 50µm have been demonstrated. A carrier recombination simulation was developed to analyze the experimental data. Results from measurements performed on 4 mercury cadmium telluride focal plane arrays show strong correlation between spatial maps of the lifetime, dark current, and relative response.

36 MATERIALS SCIENCE↗

AmeriFlux US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1

This is the AmeriFlux version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River. Landcover at the site is wetsedge (based on NSSI land cover map). During the first campaign (2013-2014), the tower location was 70.085450N; -148.570160W. It was moved to the current location (70.085050N, 148.567090W) during 2022 to 2024.

Krishnan, Praveena [NOAA/ARL/ATDD]↗