Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flue gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Cross-Linked Polyphosphazene Blends as Robust CO2 Separation Membranes

An effective cross-linking technique allows a viscous, highly gas permeable hydrophilic polyphosphazene to be cast as solid membrane films. By judicious blending with other polyphosphazenes to improve mechanical properties, a membrane exhibiting the highest CO2 permeability (610 barrer) combined with good CO2/N2 selectivity (35) among polyphosphazenes is described here. The material demonstrates performance stability after 500 hours of exposure to a coal-fired power plant flue gas, making it attractive for use in carbon capture applications. Its CO2/N2 selectivity under conditions up to full humidity is also stable, and although the gas permeability does decline, the performance is fully recovered upon drying. The high molecular weight of these heteropolymers also allows them to be cast as a thin selective layer on an asymmetric porous membrane, yielding CO2 permeance of 1200 GPU, CO2/N2 pure gas selectivity of 31, which does not decline over 2000 hours due to physical aging. In addition to gas separation membranes, this cross-linked polyphosphazene can potentially be extended to other applications such as drug delivery or proton exchange membranes which take advantage of the polyphosphazene’s versatile chemistry.

Kusuma, Victor↗

Enhancing Selective Hydrofluorocarbon Greenhouse Gas Capture via Halogenation of Metal–Organic Frameworks

Hydrofluorocarbons (HFCs) are anthropogenically produced greenhouse gases with longer atmospheric lifetimes and higher global warming potentials than those of carbon dioxide. General strategies to abate their emissions from industrial point sources, such as via adsorptive capture, remain scarce. Herein, we uncover the key structure–property relationships that lead to strong binding of HFCs such as fluoroform (CHF 3 ) and difluoromethane (CH 2 F 2 ) in metal–organic frameworks (MOFs) under the low pressures relevant to flue gas scrubbing. Extensive gas sorption and computational studies support that the Zr-based microporous framework MOF-801-Br or HHU-2-Br (HHU = Heinrich-Heine-University Düsseldorf) strongly binds HFCs due to its synergistic combination of Zr-OH sites on the nodes and bromine sites on the linkers. As such, MOF-801-Br demonstrates a record-setting performance for separating CHF 3 from N 2 under dilute conditions. Our work highlights that the combination of multiple hydrogen-bonding sites in microporous MOFs represents a generalizable strategy for HFC capture, enabling their selective removal from industrial waste streams.

adsorption↗

Dual Anion-Cation Crosslinked Poly(ionic liquid) Composite Membranes for Enhanced CO2 Separation

Herein, we propose a strategy of developing novel dual anionic-cationic crosslinked poly(IL)-IL composite membranes via a photopolymerization method for enhanced CO2 separations. These are the first examples of dually photopolymerized anionic-cationic poly(IL)-IL composite systems, in which the backbones of poly(IL)s feature both pendant anions and cations without any mobile counterions unlike poly(IL) reported so far in the literature. A new type of dual photopolymerizable anionic-cationic IL (DIL) monomer having methacrylate functional group tethered with highly delocalized sulfonimide anion (–SO2–N(-)–SO2–C7H7) and a vinylimidazolium counterion ([C4(vim)](+)) was successfully synthesized and photopolymerized with four distinct amounts of free IL with a structurally analogous cation ([C4(mim)][Tf2N]) and 20 wt% PEGDA crosslinker, offering novel composite matrices. Further, the structure-property relationships as well as gas separation behaviors of the four newly developed dual anioniccationic poly(IL)-IL composite membranes were extensively characterized by FT-IR, DSC, and XRD. All of the newly developed dual anionic-cationic poly(IL)-IL composite membranes displayed outstanding permselectivites for CO2/CH4, CO2/N2, and CO2/H2 gas pairs together with reasonable CO2 permeabilities. As a result, all the dual anionic-cationic poly(IL)-IL composite membranes outperformed the common poly(IL)-IL systems in the upper bound limit plots with best CO2 permeability of 40 barrer and CO2/CH4 permselectivity of 85. This study may pave a new platform to explore countless potential poly(IL)-IL composites for selective separation of CO2 from flue gas, natural gas, and syngas streams.

Irshad Kammakakam↗

The Staged, Pressurized Oxy-Combustion Technology: Status and Application to Boiler Retrofits to Yield Carbon-Negative Power via Biomass

Recognizing the benefits of pressurization and fuel staging on the efficiency of oxy-combustion, the staged, pressurized oxy-combustion (SPOC) process was introduced in 2012. The combination of fuel staging and pressurized oxy-combustion results in a more compact plant, a higher plant efficiency and reduced costs for pollutant and greenhouse gas removal compared with plants equipped with conventional carbon capture. This approach to power generation enables a modular boiler design and optimizes the plant for flexible operation, which is essential to meet the demands of the modern grid when it contains intermittent power sources. Originally designed to burn coal, the SPOC process is well-suited for biomass because the combustion of biomass leads to a high moisture content in the flue gas and the SPOC process is able to recover the latent heat of this moisture, enhancing system performance over that of traditional biomass combustion at atmospheric pressure. The present work is focused on evaluating the potential for utilizing the SPOC process in retrofit applications wherein the boilers of an existing plant are replaced with the SPOC process, and woody biomass is used as the fuel to yield carbon-negative power. Two applications are considered: power generation and cogeneration (heat and power). Modeling these systems in Aspen Plus demonstrates that the SPOC process surpasses the performance of baseline plants with post-combustion capture (PCC) for both power generation and cogeneration. Specifically, compared to a PCC equipped plant, the SPOC power plant has 33% higher efficiency, and the SPOC cogeneration plant reaches 42% higher net energy. Experimentally, the existing SPOC facility was fired for the first time with 100% biomass and after minor improvements were made to the feeding system, the facility demonstrated excellent performance during startup, steady-state operation and turndown.

Carbon capture and storage↗

Simulation of fluidized bed combustors. I - Combustion efficiency and temperature profile

A chemical engineering analysis is made of fluidized-bed combustor (FBC) performance, with FBC models developed to aid estimation of combustion efficiency and axial temperature profiles. The FBC is intended for combustion of pulverized coal and a pressurized FBC version is intended for firing gas turbines by burning coal. Transport phenomena are analyzed at length: circulation, mixing models, drifting, bubble wake lift, heat transfer, division of the FB reactor into idealized mixing cells. Some disadvantages of a coal FBC are pointed out: erosion of immersed heat-transfer tubing, complex feed systems, carryover of unburned coal particles, high particulate emission in off-streams. The low-temperature bed (800-950 C) contains limestone, and flue-gas-entrained SO2 and NOx can be kept within acceptable limits.

Horio, M.↗

Evaluating solvothermal and mechanochemical routes towards the metal–organic framework Mg 2 ( m -dobdc)

Metal–organic frameworks bearing coordinatively unsaturated Mg(II) sites are promising materials for gas storage, chemical separations, and drug delivery due to their low molecular weights and lack of toxicity. Furthermore, there remains a limited number of such MOFs reported in the literature. Herein, we investigate the gas sorption properties of the understudied framework Mg 2 (m-dobdc) (dobdc 4– = 4,6-dioxido-1,3-benzenedicarboxylate) synthesized under both solvothermal and mechanochemical conditions. Both materials are found to be permanently porous, as confirmed by 77 K N 2 adsorption measurements. In particular, Mg 2 (m-dobdc) synthesized under mechanochemical conditions using exogenous organic base displays one of the highest capacities reported to date (6.14 mmol g –1 ) for CO 2 capture in a porous solid under simulated coal flue gas conditions (150 mbar, 40 °C). As such, mechanochemically synthesized Mg 2 (m-dobdc) represents a promising new framework for applications requiring high gas adsorption capacities in a porous solid.

36 MATERIALS SCIENCE↗

Polymeric membranes for separation of gases

Membranes, methods of making the membranes, and methods of using the membranes are described herein. The membranes can comprise a gas permeable support layer, optionally an inorganic layer disposed on the support, and a selective polymer layer disposed on the inorganic layer. In some cases, the selective polymer layer can comprise an amine-containing polymer and an amino acid salt dispersed within the amine-containing polymer. In other cases, the selective polymer layer comprises a sterically hindered amine-containing polymer, such as a sterically hindered derivative of polyvinylamine. The membranes can be used, for example, to separate gaseous mixtures, such as flue gas.

Ho, W.S. Winston↗

Applications study of advanced power generation systems utilizing coal-derived fuels. Volume 1: Executive summary

The technology status of phosphoric acid and molten carbon fuel cells, combined gas and steam turbine cycles, and magnetohydrodynamic energy conversion systems was assessed and the power performance of these systems when operating with medium-Btu fuel gas whether delivered by pipeline to the power plant or in an integrated mode in which the coal gasification process and power system are closely coupled as an overall power plant was evaluated. Commercially available combined-cycle gas turbine systems can reach projected required performance levels for advanced systems using currently available technology. The phosphoric acid fuel cell appears to be the next most likely candidate for commercialization. On pipeline delivery, the systems efficiency ranges from 40.9% for the phosphoric acid fuel cell to 63% for the molten carbonate fuel cell system. The efficiencies of the integrated power plants vary from approximately 39-40% for the combined cycle to 46-47% for the molden carbonate fuel cell systems. Conventional coal-fired steam stations with flue-gas desulfurization have only 33-35% efficiency.

Robson, F. L.↗

Energy Conservation Alternatives Study (ECAS): Conceptual Design and Implementation Assessment of a Utility Steam Plant with Conventional Furnace and Wet Lime Stack Gas Scrubbers

A study was performed to estimate the technical/economic characteristics of a steam power plant (3500 pounds per square inch gauge, 1000 degrees Fahrenheit / 1000 degrees Fahrenheit) with a coal-burning radiant furnace and a wet lime stack gas scrubber to control sulfur emissions. Particulate emissions were controlled by an electrostatic precipitator operating at 300 degrees Fahrenheit. The stack gas from the scrubber was reheated from 125 degrees Fahrenheit to 250 degrees Fahrenheit as a base case, and from 125 degrees Fahrenheit to 175 degrees Fahrenheit as an alternate case. The study was performed on a basis consistent with the General Electric ECAS Phase II evaluation of advanced energy conversion systems for electric utility baseload applications using coal or coal-derived fuels. A conceptual design of the power plant was developed, including the on-site calcination of limestone to lime and the provision of sludge ponds to store the products of flue gas scrubbing. From this design, estimates were derived for power plant efficiency, capital cost, environmental intrusion characteristics, natural resource requirements, and cost of electricity at an assumed capacity factor of 65 percent. An implementation assessment was performed where factors affecting applicability of the conceptual design power plant in electric utility generation systems were appraised. At 250 degrees Fahrenheit and 175 degrees Fahrenheit stack gas temperatures respectively, the plants showed a cost of electricity of 39.8 and 37.0 mills per kilowatt-hours and overall plant efficiencies of 32 percent and 34 percent.

Brown, Dale H.↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Flexible FlueCO2

Carbon dioxide (CO2) emission reductions remain a significant challenge on the path to clean energy. There are increasing legislative, social, and environmental factors motivating CO2 emissions reduction from power plants with carbon capture and storage (CCS). CCS in natural gas combined cycle (NGCC) power plants is critical to achieve a net-zero carbon electricity grid. Enhanced 45Q tax credits provide new incentives, but currently available technologies are unable to profitably operate in grids with deep variable renewable penetration which require flexible NGCC operation. Luna Labs has developed the FlueCO2 membrane to enable a profitable NGCC-CCS process. The FlueCO2 membrane couples steam transport across the membrane to CO2 transport in the opposite direction, enabling high capture efficiencies and low energy costs even at low CO2 concentrations. The dual-phase membrane can operate in the range of typical flue gas temperatures and pressures and does not require temperature or pressure cycling. Luna Labs’ FlueCO2 technology enables flexible and profitable operation of NGCC plants with lower capital investment and impact on electricity prices. In this Phase 1 project, Luna Labs utilized experimental testing, modeling, process simulation, and standardized costing methodologies to evaluate the techno-economic value of a 650 MW greenfield NGCC plant with FlueCO2 (NGCC-FlueCO2). Key design requirements for operation were established and plant performance under load-leveling conditions was validated through computational fluid dynamics and process modeling. Luna Labs developed a dynamic modeling tool which modeled plant operational modes across a variety of tax structures and electricity pricing scenarios to project the overall Net Present Value (NPV) of the NGCC-FlueCO2. FlueCO2 minimizes the impact of CCS integration on plant operation by integrating directly into the NGCC heat recovery steam generator (HRSG). By tapping into the plant’s low-pressure (LP) steam, operators can divert LP steam to the greenfield NGCC and/or CCS process in response to dynamic markets. Since FlueCO2 will not significantly affect HRSG (or NGCC) operation, CCS only turns off during peak power demand (>$250/MWh). Under baseload conditions, FlueCO2 lowers the capital (37%), energy (36%) and carbon capture (<$40/tonne) costs and can increase the overall plant lifetime NPV by approximately ~$1B in comparison with NGCC solvent-based capture reference cases (NETL Case 31B). Luna Labs has shared its costing tools with several interested partners and customers, which follows a generalizable approach to costing analysis.

Kelly, Jesse↗

High CO2 Capture Rate Cost and Performance for F- and H-Class Natural Gas Combined Cycles (NGCC)

The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.

Fout, Timothy↗

Influence of design and operating parameters for additively manufactured intensified packing devices on CO 2 -Absorption column cooling and capture efficiency

Solvent-based CO 2 absorption is technologically a matured CO 2 capture pathway but suffers from: high regeneration energy demand, and solvent temperature rise and decreased capture efficiency caused by the heat of reaction. While research has focused on developing non-aqueous and low-aqueous solvents for decreasing the regeneration energy, the temperature bulge due to exothermic absorption is typically dealt with by cooling the solvent with an external inter-stage heat-exchanger. This approach may increase the overall process footprint, as well as capital and operating costs. Here, the current study explores a process intensification approach by incorporating inside the column an additively manufactured intensified packing device that consists of corrugated plates and internal coolant channels. The corrugated plates provide surface area for mass transfer between gas and liquid, while cooling fluid inside the internal channels removes heat from the exothermic reactive system. Two different intensified devices with specific surface areas of 266 m 2 /m 3 and 359 m 2 /m 3 were designed, manufactured, and tested inside a 2.06-m long and 0.203-m diameter column packed with commercial Mellapak 250Y packing. The device with a lower surface area showed up to 27 % reduction in cooling performance. A steady-state heat transfer model provides good agreement with the experimental column temperature and intra-stage heat removal data. Although a decrease in heat transfer performance was observed for the device with lower surface area, CO 2 capture experiments performed with simulated flue gas and low-aqueous solvent demonstrated that both intensified devices lead to a similar improvement of 12 % in capture efficiency. This study provides an understanding on simplifying the intensified packing device geometry and decreasing the device fabrication cost by 25 % without compromising with the CO 2 absorption performance of the packed column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequentially prepared Mo-V-Based SCR catalyst for simultaneous Hg 0 oxidation and NO reduction

Molybdenum (Mo)-vanadium (V)-based selective catalytic reduction (SCR) catalyst synthesized by the sequential impregnation of Mo and W followed by V was investigated for simultaneous elemental mercury (Hg 0 ) oxidation and nitrogen oxide (NO) reduction in an existing SCR unit with respect to different TiO 2 phases, calcination temperatures, flue gas constituents, gas velocities, and reaction temperatures. Anatase phase TiO 2 and the calcination temperatures of 400 and 500 degrees C resulted in similar to 69% Hg 0 oxidation at 10 ppmv HCl and 350 degrees C. The high calcination temperature of 700 degrees C resulted in TiO 2 phase transformation from anatase to rutile and agglomeration. The modified SCR catalyst prepared with the impregnation sequence of Mo and W followed by V using anatase TiO 2 and calcination temperature 500 degrees C showed similar to 99% Hg 0 oxidation and 87% NO reduction conversions at an NH 3 /NO molar ratio of 0.9 under 350 degrees C and 5,000 hr -1 space velocity in typical sub-bituminous and lignite coal simulated flue gases. Finally, the effects of these parameters and conditions were further investigated using various characterization techniques including BET, TEM, XRD, NH 3 TPD and XAFS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

High Inlet Temperature Combustor for Direct-Fired Supercritical Oxy-Combustion

It is envisioned that supercritical CO 2 (sCO 2 ) electric power plant efficiencies can exceed 52% with 99% carbon capture using direct-fired oxy-combustion. Such efficiencies would be competitive with Natural Gas Combined Cycles (NGCC) and operate with nearly zero carbon emissions. To achieve high plant efficiencies, turbine inlet conditions must approach 1,200 °C at 250 bar. Such conditions, while desirable from a systems perspective, exceed the current state of the art in turbine design and materials qualification. The team of Southwest Research Institute ® (SwRI ® ), Georgia Institute of Technology (Georgia Tech), Spectral Energies, LLC (Spectral), GE Global Research (GE-GRC), and the University of Central Florida (UCF) sought to demonstrate an intermediate step toward these high efficiency plants with the development of a 1 MWth, subscale direct-fired oxy-fuel combustor. The efforts focused largely on the development of an auto-ignition based combustion system capable of providing the targeted 1200 °C and the pilot-scale plant to operate the combustor. While the project was stopped short of the commissioning and demonstration work, the advances made in this effort will reduce risks associated with chemical kinetics, thermal management, water separation, flue gas cleanup, materials selection, and corrosion in future demonstration efforts for the direct-fired oxy-fuel combustion cycles. The following report documents the design, analysis, and installation efforts completed during the project periods of performance.

03 NATURAL GAS↗

Direct Air Capture of CO 2 and Delivery to Photobioreactors for Algal Biofuel Production (Final Report)

A mobile DAC system was designed and constructed to pair with photobioreactors growing algae for biofuel production. The DAC system was designed as a versatile research system, rather than a compact production unit. The system was constructed and mounted on a mobile skid to facilitate transportation to the algae production site. Within the DAC system, CO 2 was captured using amine-loaded monoliths that allow for high CO 2 uptake with low pressure drop. The CO 2 is collected using a Global Thermostat patented temperature/vacuum swing adsorption (TVSA) process. Amine sorbents and process conditions were optimized to produce 10 to >20 g CO 2 .h-1. The stability of the amine sorbents was also studied, with sorbent modifications made to improve stability to degradation by oxidation. An Algenol-developed Spirulina strain (Arthrospira platensis AB2293) was selected as the production cyanobacterial strain. AB2293 cultured was inoculum for outdoor production following PBR installation by Algenol. The PBR system was composed of three independent PBRs, with each PBR composed of four hanging bags internally recirculated by a liquid turnover pump. The PBRs were operated outdoors in Atlanta, GA, and integrated with the DAC system. Algae were grown with similar productivity using DAC-CO 2 as algae grown using pure CO 2 obtained commercially (Airgas). Throughout the experimental duration, no discoloration was observed, and cellular morphology was consistent between the two experimental treatments. An LCA including lifecycle greenhouse gas emissions, full life cycle inventory of the Algenol system and the DAC system and integrated DAC+PBR system was developed. Lifecycle greenhouse gas emissions were calculated for capture of carbon dioxide using input from Global Thermostat and the National Renewable Energy Laboratory. Three scenarios for energy provision were evaluated: a natural gas combined heat and power system sized to meet the electricity requirement, a natural gas combined heat and power system sized to meet the process heat requirements, and a system without on-site power that procures the electricity from the grid. In all three cases, as expected, the major contributor to the emissions is the energy consumption associated with the desorption step of the DAC process. The LCA quantified the reduced potential energy and greenhouse gas emissions of heat and mass integration of DAC and Algenol compared to unintegrated DAC and Algenol systems. A life cycle assessment of the role of sorbent productivity and lifetime was also developed. The development of more robust, oxidation resistant DAC sorbents may enable small reductions in energy requirements and in lifecycle greenhouse gas emissions and other environmental impacts. NREL performed techno-economic analysis (TEA) to identify the integration scenario most likely to achieve a 15% cost reduction target versus the baseline. Heat and mass integration of DAC and the PBR is critical to minimizing the MFSP. The baseline case utilizes no heat and mass integration, and the DAC system provides 100% of the CO 2 required by the photobioreactors (20 tonnes/hr), operating for 12 hours/day capturing 40 tonnes CO 2 /operating hour. The minimum fuel selling price (MFSP) of ethanol calculated from the baseline case was $10.68/gal ethanol. This corresponds with a targeted MFSP of $9.07/gal ethanol (or 15% reduction). This target was achieved by integration Option 2a with the greatest cost reduction of 17.8% (or $8.78/gal) and integration Option 2b with a cost reduction of 16.4% (or $8.93/gal). Reductions in MFSP are attributed to two primary process considerations: (a) CO 2 storage at night reduces the capital expenses associated with DAC (i.e., increasing on-stream time); and (b) distributed DAC scenarios (DAC-PBR integration Options 2a and 2b) make use of boiler and DAC CHP flue gas CO 2 (free). Direct air capture on-stream time was one of the largest contributors to MFSP reduction.

09 BIOMASS FUELS↗