Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Regulating TNCs: Should Uber and Lyft set their own rules?

We evaluate the impact of three proposed regulations of transportation network companies (TNCs) like Uber, Lyft and Didi: (1) A minimum wage for drivers, (2) a cap on the number of drivers or vehicles, and (3) a per-trip congestion tax. The impact is assessed using a queuing theoretic equilibrium model which incorporates the stochastic dynamics of the app-based ride-hailing matching platform, the ride prices and driver wages established by the platform, and the incentives of passengers and drivers. We show that a floor placed under driver earnings can push the ride-hailing platform to hire more drivers and offer more rides, at the same time that passengers enjoy faster rides and lower total cost, while platform rents are reduced. Contrary to standard competitive labor market theory, enforcing a minimum wage for drivers benefits both drivers and passengers, and promotes the efficiency of the entire system. This surprising outcome holds for almost all model parameters, and it occurs because the wage floor curbs TNC labor market power. In contrast to a wage floor, imposing a cap on the number of vehicles hurts drivers, because the platform reaps all the benefits of limiting supply. The congestion tax has the expected impact: fares increase, wages and platform revenue decrease. Here, we also construct variants of the model to briefly discuss platform subsidy, platform competition, and autonomous vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling of UH-60A Hub Accelerations with Neural Networks

Neural network relationships between the full-scale, flight test hub accelerations and the corresponding three N/rev pilot floor vibration components (vertical, lateral, and longitudinal) are studied. The present quantitative effort on the UH-60A Black Hawk hub accelerations considers the lateral and longitudinal vibrations. An earlier study had considered the vertical vibration. The NASA/Army UH-60A Airloads Program flight test database is used. A physics based "maneuver-effect-factor (MEF)", derived using the roll-angle and the pitch-rate, is used. Fundamentally, the lateral vibration data show high vibration levels (up to 0.3 g's) at low airspeeds (for example, during landing flares) and at high airspeeds (for example, during turns). The results show that the advance ratio and the gross weight together can predict the vertical and the longitudinal vibration. However, the advance ratio and the gross weight together cannot predict the lateral vibration. The hub accelerations and the advance ratio can be used to satisfactorily predict the vertical, lateral, and longitudinal vibration. The present study shows that neural network based representations of all three UH-60A pilot floor vibration components (vertical, lateral, and longitudinal) can be obtained using the hub accelerations along with the gross weight and the advance ratio. The hub accelerations are clearly a factor in determining the pilot vibration. The present conclusions potentially allow for the identification of neural network relationships between the experimental hub accelerations obtained from wind tunnel testing and the experimental pilot vibration data obtained from flight testing. A successful establishment of the above neural network based link between the wind tunnel hub accelerations and the flight test vibration data can increase the value of wind tunnel testing.

UH-60A AIRCRAFT↗

Effect of recycled fibers and shredded intermediates variation on the mechanical properties and energy absorption of fiber‐reinforced composite panels

Abstract The global composite industry generates large quantities of waste which mostly ends up in landfills due to a lack of established end‐use applications for multiple waste streams. The scrap from end‐of‐life (EoL) includes manufacturing waste such as dry chopped fiber tows, loose fibers, shredded fibers from fabric textile operations, cured/semi‐cured prepregs, and fully cured composite structure waste from aircraft, automobiles, wind blades, boats, and pressure vessels. In this work, different composite waste streams were reduced to shredded intermediates, followed by simple blending, and subjected to wet compression molding to produce composite panels. The panels/plaques were tested for mechanical properties (flexure and impact), fiber‐matrix wet‐out, and property bounds. It was found that wet‐compression molding was a viable and scale‐able approach to produce recycled panels from EoL composites shredded scrap. Furthermore, full‐scale size panels for use in truck bodies and intermodal shipping container flooring were manufactured and their impact resistance was tested using a drop weight impact test. They were tested both for high‐ and low‐velocity load. In the case of high‐velocity load, the average impact load was 14,673 N; the average absorbed energy was 101.6 J; the average elastic energy was 11.7 J and the impact resistance was 1065 J/m. In the case of the low‐velocity drop weight impact test, it was found that the average impact load was 7877.358 N; the average absorbed energy was 9.718 J; the average elastic energy was 9.14 J, and the impact resistance was 184.1 J/m. The shredded composite was shown to be a candidate material for the manufacture of truck bodies and intermodal containers’ flooring panels. Highlights By using shredded intermediates from different composite waste streams, it is possible to manufacture composite panels. Wet–compression process is an appropriate technique for manufacturing recycled fiber composite panels. Regardless of the source of scrap, the mechanical properties of the produced composite panels were improved. The recycling process technology can be transformed to commercial scale to produce full‐size transportation flooring panels. A product pathway is established in consideration of lower cost and improved recyclability.

Vaidya, Uday↗

Dose Modeling for Harborview Research and Training Facility

The Harborview Research and Training (R&T) Facility at the University of Washington (UW) was accidently contaminated from a breached sealed source of Cesium-137. The release occurred during removal of the sealed source from its holder within a portable hot cell in the loading dock area near room 220. The loading dock and northeast corner of the building above the ground floor were impacted by the release, whereas the remaining portions of the R&T Facility were minimally affected. Detailed descriptions of the R&T Facility and the affected area/rooms are included in Section 2. The RESRAD Team in the Environmental Science Division of Argonne National Laboratory visited the site on August 12, 2019, and interviewed the R&T Facility building manager and staff working in the building at that time. Site- and building-specific data were collected including building floor plan CAD drawings, building occupants’ working hours, contaminated rooms photos and their dimensions, building air exchange rates, building materials and “curtain wall” details, and so forth. These data are being used in the dose modeling for potential occupants of the building after it is remediated. The dose modeling was performed using the RESRAD-BUILD computer code, which is designed for the evaluation of radiologically contaminated buildings (Yu et al. 2003). Two hypothetical building occupants of the Harborview R&T Facility were evaluated: a researcher occupying room 726 (a research laboratory on the seventh floor) and a custodian occupying room 220 (loading dock and trash compactor room with a rollup door). A maintenance worker that will be spending less time in impacted areas was not modeled because it will be bounded by other two hypothetical building occupants modeled. A summary description of the RESRAD-BUILD is provided in Appendix A, and the modeling of potential doses to a researcher and a custodian is described in detail in Section 3. A summary and a discussion of the dose modeling results are included in Section 4. The parameters used in the RESRAD-BUILD modeling are included in Appendix B. This report documents the dose modeling results; it does not describe measurements of the actual radioactivity levels at the Harborview R&T Facility, nor does it set any expectation for the actual final radioactivity levels. The radiation doses presented are modeling results based on the generic screening values of Cs-137 and several conservative assumptions and are meant only to assist in decision making regarding decontamination of the Harborview R&T Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Updated Available Drawdowns for Big Hill SPR Caverns - Model Including the Caprock Fault

This report updates the estimated values of the baseline available drawdowns for the caverns at the Big Hill storage facility, and an updated table listing the available drawdowns. An updated finite element numerical analysis model, which included a fault in the caprock layers, was constructed and the daily data of actual wellhead pressures and oil-brine interfaces was used. The number of available drawdowns for each of the Big Hill SPR caverns is estimated using the new model. All caverns are predicted to have five available drawdowns remaining from a geomechanical perspective. BH-101 and 105 have a region of concern at the floor edge and/or sloping floor, where tensile and dilatant stresses are predicted to occur during each workover. The tensile state is predicted to occur because of the geometries of the edge and floor. Therefore, geomechanical examination for two caverns would be recommended after a drawdown leach. The well integrity of each cavern is not investigated in this report. The estimates for the number of baseline available drawdowns are subject to change in the future as the knowledge of physical phenomena at the sites, and the further development of the models of geomechanical behavior at the sites, evolve over time.

02 PETROLEUM↗

UT-GOM2-2 Drilling Fluid (Technical Note)

It is proposed that a salt-saturated, water-based mud might improve borehole stability for UT-GOM2-2 relative to a fresh-water-based mud. However, the primary objective for UT-GOM2-2 is to safely and successfully acquire uncompromised hydrate-bearing sediment cores. This can only be done if conditions stay within the hydrate stability zone, and well away from the hydrate stability boundary. The addition of salt to the drilling mud, shifts the hydrate stability boundary closer to estimated conditions. This shift, by some estimates of pressure and temperature, where conditions now fall outside of the hydrate stability zone, may result in borehole enlargement and the release of free gas into the borehole. This shift by all estimates, even when coring conditions stay inside the hydrate stability zone, shrinks the window between the estimated conditions and the hydrate stability boundary. This shift is likely to compromise the hydrate-bearing cores while they are being recovered from the bottom-hole to the rig floor. In this report we present two examples: 1) Assuming temperature and pressure from in-situ estimates: Hydrate within the target reservoirs (Orange and Blue) at Walker Ridge Block 313 (WR 313) will be outside the hydrate stability zone in the presence of a drilling mud with 9.5 wt.% salinity (the salinity of the proposed 10.5 ppg salt-based mud) at in situ pressure and temperature. Thus, the hydrate will be unstable. A 10.5 ppg salt-based mud may result in dissociation of the hydrate into its components: water and gas. 10.5 ppg salt-based mud may enlarge the borehole, release free gas into the borehole, and compromise the cores. 2) Assuming temperatures equal to the measured LWD borehole temperatures at this location: Hydrate within the target reservoirs will be stable with a salinity of 9.5 wt.% (the salinity of the proposed 10.5 ppg salt-based mud), but possibly unstable (just at the methane hydrate stability boundary) for a salinity of 17.2 wt.% (the salinity of the proposed 13.5 ppg salt-based kill mud). if the borehole has the same temperature as recorded during previous LWD drilling at this location. A 13.5 ppg salt-based kill mud may destabilize the borehole. More importantly, a 10.5 ppg salt-based mud does not provide a large enough window between the estimated conditions and the hydrate stability boundary. Core temperatures and pressures fluctuate from the bottom-hole conditions as the core is brought up from the bottom-hole to the rig floor. These fluctuations are likely to cause the hydrate in the cores to touch or cross the stability boundary. Therefore, cores captured using a 10.5 ppg salt-based mud are likely to be compromised during core recovery to the rig floor.

03 NATURAL GAS↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks – 25213

The Hanford Nuclear Reservation site contains approximately 211 million liters of radioactive and chemically hazardous waste arising from nuclear weapons production, beginning with World War II, and continuing through the Cold War [1]. The waste is stored in 177 carbon-steel underground storage tanks, of which 149 are single-shell tanks (SSTs) and the remaining are double-shell tanks (DSTs). The mission of an ongoing River Protection Project is to retrieve the waste from the underground storage tanks and then treat and immobilize (i.e., vitrify) it for disposal. Waste from the older SSTs is being progressively retrieved into the newer DSTs for storage pending treatment, immobilization, and disposal. Figure 1 depicts a typical DST design [2]. The tank is approximately 23 m in diameter and 9 m high and has a domed structure and has a capacity of 4000 m3. The tank wall and floor vary in thickness between approximately 10 mm and 25 mm depending on location. The thicker wall sections are near the curved transition between the tank wall and the floor, while the thinner sections are located near the top of the tank wall. The tank floor thickness varies from 25 mm at the tank center to 10 mm near the tank wall. The tanks were constructed of either ASTM A516 Grade 65 or ASTM A537 Class 1 carbon steel and were post-weld heat treated to reduce the risk of SCC.

Shukla, Pavan K. [Savannah River National Laborato↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Modification of one man life raft

A one man inflatable life raft is described. The raft has an inflatable tube perimetrically bounding the occupant receiving space with a flexible floor member. A zippered opening in the floor allows entry and facilitates the use of a constant diameter tube. An airtight fabric bulkhead divides the peripheral tube longitudinally into inflatable tube sections, where if either tube section were punctured, the bulkhead would move into the punctured section to substitute for the punctured wall portion and maintain the inflatable volume of the tube. The floor member is attached to the central portion of the tube wall so that either side of the raft can be the up side.

Soter, E. J.↗

Experimental studies for determining human discomfort response to vertical sinusoidal vibration

A study was conducted to investigate several problems related to methodology and design of experiments to obtain human comfort response to vertical sinusoidal vibration. Specifically, the studies were directed to the determination of (1) the adequacy of frequency averaging of vibration data to obtain discomfort predictors, (2) the effect of practice on subject ratings, (3) the effect of the demographic factors of age, sex, and weight, and (4) the relative importance of seat and floor vibrations in the determination of measurement and criteria specification location. Results indicate that accurate prediction of discomfort requires knowledge of both the acceleration level and frequency content of the vibration stimuli. More importantly, the prediction of discomfort was shown to be equally good based upon either floor accelerations or seat accelerations. Furthermore, it was demonstrated that the discomfort levels in different seats resulting from similar vibratory imputs were equal. Therefore, it was recommended that criteria specifications and acceleration measurements be made at the floor location. The results also indicated that practice did not systematically influence discomfort responses nor did the demographic factors of age, weight, and sex contribute to the discomfort response variation.

Dempsey, T. K.↗

Concorde noise-induced building vibrations, Sully Plantation - Report no. 2, Chantilly, Virginia

Noise-induced building vibrations associated with Concorde operations were studied. The approach is to record the levels of induced vibrations and associated indoor/outdoor noise levels in selected homes, historic and other buildings near Dulles International Airport. Representative data are presented which were recorded at Sully Plantation, Chantilly, Virginia during the periods of May 20 through May 28, 1976, and June 14 through June 17, 1976. Recorded data provide relationships between the vibration levels of windows, walls, floors, and the noise associated with Concorde operations, other aircraft, and nonaircraft events. The results presented are drawn from the combined May-June data base which is considerably larger than the May data base covered. The levels of window, wall and floor vibratory response resulting from Concorde operations are higher than the vibratory levels associated with conventional aircraft. Furthermore, the vibratory responses of the windows are considerably higher than those of the walls and floors. The window response is higher for aircraft than recorded nonaircraft events and exhibits a linear response relationship with the overall sound pressure level. For a given sound pressure level, the Concorde may cause more vibration than a conventional aircraft due to spectral or other differences. However, the responses associated with Concorde appear to be much more dependent upon sound pressure level than spectral or other characteristics of the noise.

Source record↗

Concorde noise-induced building vibrations: John F. Kennedy International Airport

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

Mayes, W. H.↗

Geology of the Valles Marineris - First Analysis of Imaging from the Viking 1 Orbiter Primary Mission

The Valles Marineris on the planet Mars constitute an enormous group of steep-walled equatorial canyons extending over an area more than 4000 km long and up to 700 km wide. An overview of Valles Marineris is provided, taking into account canyon system subdivisions, imaging and topographic data, Noctis Labyrinthus, western troughs, central troughs, east central troughs, and eastern canyons. Aspects of canyon wall and canyon floor morphology are discussed, giving attention to erosional features, layered rocks in canyon walls, tectonic features, plains, landslide deposits, hilly terrain, fractured floor, and floor plateaus and ridges. Upland pits and closed depressions in the canyons are considered along with regional tectonics and regional erosional styles.

Blasius, K. R.↗

Geologic application of thermal inertia imaging using HCMM data

The author has identified the following significant results. The day infrared and visible HCMM satellite data for Death Valley taken on 31 May 1978 were compared with aircraft data of the same area taken in March of the same year. In the visible image, it is possible to note the drying of the valley floor during the two month period between acquisition of the two data sets. On the IR image however, the valley floor remains cool, probably indicating that while the standing water has disappeared, the floor is still moist.

Paley, H. N.↗

New morphometric data for fresh lunar craters

Morphometric relations have been determined for 2598 fresh craters on the lunar nearside using data given in the catalog of Wood and Andersson (1978). For each of five principal morphological types, typified by Albategnius C, Biot, Sosigenes, Triesnecker, and Tycho, statistical relations are documented for the following: crater diameter and depth; floor diameter and crater diameter; central peak height and crater diameter; average wall slope and crater depth; central peak occurrence and crater diameter; occurrence of scallops or terraces and crater diameter. The first four relations generally confirm the conclusions of Pike (1977), but the last two differ from results reported by Smith and Sanchez (1973). Small (diameter less than 20 km) flat-floored craters formed in mare terrains are as much as 10% deeper than those formed in the highlands, and the depths of small bowl-shaped craters reflect even greater dependence on terrain. Larger, scalloped-walled craters are deeper in highland terrain than on the maria. Although wall failure does not occur until the crater diameter reaches 13 km, central peaks are found in flat floor craters as small as 2 km.

Wood, C. A.↗

Central peaks in lunar craters - Morphology and morphometry

Fresh lunar craters with diameters from 17 to 175 km are found to display a linear relationship between the central peak morphology and morphometry and such critical crater parameters as rim crest diameter, floor diameter, and substrate. Some other previously established linear relationships have been cited as evidence that floor diameter, peak height, and peak ring diameter are related to the kinetic energy of impact. The two new relations derived in the present work would therefore indicate that the central peaks, too, are related to the kinetic energy of impact, and probably begin to form early in the cratering event as suggested by Milton and Roddy (1972) and Head (1978). There seems to be no obvious reason to expect such linear relationships between central peak diameter and rim crest and floor diameter if the peaks are formed by gravity induced failure of the transient cavity, as suggested by Dence et al. (1968).

Hale, W.↗

Landslides in Valles Marineris, Mars

The morphology of the landslides in the Martian equatorial troughs, the geologic structure of the troughs, the time of emplacement, the similarity to terrestrial landslides, and the origin and mechanism of transport are analyzed. About 35 large landslides well-resolved on Viking images were examined, and it is found that the major landslides cover 31,000 sq km of the trough floors, and individual slides range in area from 40 to 7000 sq km. The morphologic variations of the landslides can be attributed mainly to their degree of confinement on trough floors. Many prominent landslides appear to be of similar age and were emplaced after a major faulting that dropped the trough floors. Most sliding occurred after the created scarps were dissected into spurs, gullies, and tributary canyons. Emplacement of the landslides approximately coincided with a late episode of major eruptive activity of the Tharsis volcanoes, and it is suggested that the slides may have originated as gigantic mudflows with slump blocks at their heads. The large size of many landslides is due to the fault scarps as high as 7 km on which they formed in the absence of vigorous fluvial erosion. The landslides suggest that Mars is earthlike in some respects, which may be important for further evaluations.

Lucchitta, B. K.↗