Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Dynamic Microgrids in Resilient Distribution Systems With Reconfigurable Cyber-Physical Networks

Modern distribution systems energized by inverter-interfaced distributed generators (DGs) operate as coupled cyber-physical networks (C/P-networks), where the controllable components in the physical network (P-network) are coordinated through the cyber network (C-network). The concept of dynamic microgrids (MGs) operation has been adopted to enable distribution system autonomous operation with varying electric boundaries. To further enhance system operation resiliency and flexibility, dynamic MGs operation with reconfigurable C/P-networks is discussed in this work. An evaluation framework is proposed to assess the operational feasibility of distribution feeders with multiple inverter-based dynamic MGs and come out with possible restoration solutions in the context of cross-layer C/P-network reconfiguration. Furthermore, distributed controllers are developed for components with different operating characteristics to realize seamless system topology variations and provide coordinated secondary regulation in various operation modes. Furthermore, the proposed evaluation framework along with the developed distributed controller has been validated using a Hardware-in-the-Loop (HIL) real-time CPS testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a high-fidelity multi-cycle model of the NuScale small modular reactor using VERA

With growing renewables penetration, there is increased interest in flexible power operation for nuclear reactors. For multi-unit SMRs, in particular the NuScale SMR, which is an integral pressurized water reactor, there are opportunities to optimize flexible power operation across multiple units to limit the degradation of structural and control components. Here, we focus on degradation of in-core components, specifically the control rods and reactor pressure vessel. To perform these studies a high-fidelity, multi-cycle representation of the NuScale SMR is required, with a detailed representation of the structural and control components. To this end, the NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) software. The entire transition to equilibrium is simulated, from Cycle 1 through to the equilibrium cycle. The equilibrium cycle model shows a good agreement with the NuScale design certification application (DCA) results, with differences attributable to a combination of using public domain data for the present study, and methodological differences. K-effective, power distributions, reactivity coefficients, and boron letdown curves are compared and all found to closely match. This shows that the VERA model is suitable for further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NPP Simulators for Coupled Thermal and Electric Power Dispatch

The Light Water Reactor Sustainability (LWRS) program within the United States Department of Energy supports extending the operation of the U.S. commercial nuclear power plant (NPP) fleet. Within the LWRS program, the Flexible Plant Operation and Generation (FPOG) Pathway works to diversify the revenue streams of light water reactors (LWRs) by opening opportunities for the co-generation of non-electric products in addition to supplying electrical power to the grid. Recent events have added greater motivation to these efforts. For example, the recent Inflation Reduction Act (IRA) passed by the U.S. federal government offers substantial tax incentives for producing clean hydrogen, the technology readiness level of dispatchable and high-efficiency hydrogen production has dramatically increased in a short time, and societal response to world climate change is driving a transition away from fossil fuels. Producing hydrogen with maximum efficiency using nuclear power requires dispatching both electrical and thermal power from the nuclear plant to the hydrogen plant, so testing concepts of operations for combined electrical and thermal power dispatch (TPD) from an NNP to a hydrogen plant is of interest. This report documents achievement of the Light Water Reactor Sustainability (LWRS) program milestone “Install and demonstrate a vendor-developed simulator on the Human Systems Simulation Laboratory (HSS) for dispatch of LWR electrical power to a close-coupled electrolysis plant” with a due date of Dec. 22, 2022. Several factors provide motivation for this effort. Coupling the power generation deck of a nuclear power plant to a hydrogen production facility introduces new possibilities for operational transients that must be addressed. In particular, the performance of the integrated system during startup and shutdown of the hydrogen production facility, as well as offnormal conditions, need to be evaluated to ensure there are no adverse effects on the operation of the existing NPP. The concept of operations involving the NPP, the hydrogen plant, and the electric power grid must be tested using NPP simulators and operating procedures that have been modified for TPD operations. These tests must also include dynamic simulations of the coupled tertiary thermal and electric loads as well as coordinated activities with NPP operators, tertiary load operators and grid power coordinators. The report summarizes progress in developing and testing full-scope NPP simulators at the HSSL, including a generic BWR simulator from GSE Systems, Inc. and generic PWR simulator from Westinghouse. In the case of the TPD-GBWR Simulator from GSE Systems, Inc., a BWR is thermally coupled to a high temperature electrolysis (HTE) plant that produces hydrogen and oxygen from de-ionized water. The hydrogen plant is not explicitly simulated but only included as a transient heat sink. A thermal power dispatch (TPD) system transfers heat between the steam systems at the BWR and the hydrogen plant. Operational results from two versions of the modified simulator are presented. The first version uses synthetic oil as a heat transfer fluid in a closed delivery heat loop (DHL) that generates steam at the hydrogen plant. The second version uses steam as the heat transfer fluid in a delivery steam line (DSL) to provide steam to the hydrogen plant. For both versions, the estimated thermal power delivery distance is approximately one kilometer. The amount of thermal power dispatched in the simulators is 15% of the total reactor thermal power such that the simulators provide a tool to study the feasibility of coupling a BWR to industrial processes that benefit from a combination electrical and thermal power dispatch. Ongoing work within a CRADA is also developing a full-scope PWR simulator provided by Westinghouse for both thermal and electric power coupling. This simulator is based on a PWR plant with two three-loop Westinghouse reactors. Westinghouse PWRs are sufficiently similar that a simulator of a three-loop reactor is an appropriate representation for two-loop and four-loop PWR reactors. The three-loop simulator will initially be modified for close-coupling to a 100 MW HTE hydrogen production plant that will require approximately 25 MW of thermal power while operating at its maximum rated capacity. The simulator testing will include full coupling to dynamic simulations of a hydrogen production plant and a representative bulk electric grid. The simulator provided by Westinghouse is similar to the GPWR simulator that INL has already obtained from GSE Systems but has a few important added benefits. First, the Westinghouse simulator is based on digital controls and has additional screens that can be called up to show parameter trends to assist operators in decision-making. The Westinghouse simulator also has upgrades to the controls and hardware representations, such as valve actuators, that make it more realistic and flexible in terms of accurately sim

99 GENERAL AND MISCELLANEOUS↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification of Load Flexibility in Residential Buildings Using Home Energy Management Systems

With increasing penetration of renewable energy resources, the flexibility of operating behind-the-meter (BTM) resources plays a key role in enhancing grid reliability and resilience. Residential buildings with home energy management systems (HEMS) can provide desired flexibility for the distribution system operator (DSO) while considering customer comfort and preferences. This paper discusses a methodology to quantify the flexibility of BTM resources of residential buildings using HEMS. First, we propose a model predictive control framework to formulate the flexibility band comprising nominal, upper, and lower demand profiles. Second, the paper proposes a dispatch method for HEMS to compute the control signals for each BTM resource (e.g., air conditioner, water heater, home battery system) upon receiving a flexibility service request from the DSO. The case study provides insight into the flexibility provided at the whole-home level with different user preferences and seasons. The results demonstrate that HEMS is capable of providing flexibility service at the request of the DSO while delivering primary services to the building occupants.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunities and Challenges for Hydrotreating of Catalytic Fast Pyrolysis Oil to Fuels

Catalytic fast pyrolysis (CFP) provides a versatile platform for producing fuels to combat climate change and meet decarbonizing targets. In this contribution, we will discuss the hydroprocessing of CFP oils to a variety of fuels, including sustainable aviation fuel (SAF), diesel, and marine fuel. Both standalone and co-hydroprocessing with petroleum streams will be covered. Hydrotreating CFP oil at temperatures around 400 Degrees Celsius can produce a highly deoxygenated product with oxygen contents below the detection limit. However, the quality of fuel fractions produced has been a problem, manifesting as low octane numbers for the gasoline-range fraction and low cetane numbers for the diesel-range fraction. Incorporating an initial transition zone for hydrogenation during hydrotreating was shown to dramatically increase the diesel fraction cetane number from 24 to 45. A similar approach enabled the production of a cycloalkane-rich SAF fraction meeting key ASTM 4054 guidelines with respect to density, viscosity, heating value, volatility, freeze and flash point. Over 400 hours of hydrotreating for SAF was demonstrated with no signs of catalyst bed fouling, measured by pressure drop over the catalyst bed. Compared to other fuels, marine fuel is unique in that it does not require complete deoxygenation. We investigated the minimum hydrotreating requirements to produce fuel compatible with very low sulfur fuel oil, and the results suggested 30% reduction in hydrotreating costs for this approach. Co-hydroprocessing offers an opportunity to take advantage of refinery infrastructure and economies of scale although the operation is less flexible with respect to operating conditions. Co-hydroprocessing CFP oil with petroleum streams gave efficient deoxygenation at milder conditions (e.g. at temperatures of 320 Degrees Celsius) than required for standalone hydrotreating. Over 90% incorporation of biogenic carbon in the CFP oil was confirmed by carbon-14 analysis. Hydrotreating of CFP oil, whether by standalone or co-processing, can produce a variety of fuel cuts, whose quality can be tailored by changing process conditions. Challenges remain, including long-term catalyst performance and determining CFP oil quality requirements.

09 BIOMASS FUELS↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Cycling Coal-Fired Power Plants Using High-Fidelity Models

The project delivers a well-integrated and validated simulation platform for cycling operation analysis in coal-fired power plant. Two critical mechanical components of the boiler island were analyzed through mechanical integrity assessment and economic benefit analysis. The current phase of the project focuses on the development of the integrated simulation infrastructure and prove its feasibility and effectiveness using two typical use cases. This integrated platform can help save a lot of engineering efforts for model development and simulation analysis. Through the real simulation scenarios in this document, it was demonstrated that using this platform, an analysis can be completed in approximately 2 days, while it could cost several weeks before using this platform. Going forward, the platform built in this project can be used for more boiler service applications, and it can be further enhanced with more functions/features to maximize its usage and benefits. 1) Extend component-level analysis with more use cases to cover all the major critical components of boiler island under cycling operations. A library of critical components can be developed and validated for typical pulverized coal-fired subcritical boiler units. 2) Develop predictive maintenance features based on the integrated models (Digital Twins) and engineering analysis procedures. Predictive maintenance enables each asset to be serviced based on forecast on life consumption and cost profile for replacing/welding the critical mechanical parts of the boiler. This minimizes the chance of unscheduled shutdowns and emergency services at much higher costs and prevent the fatal accidents in unit operations. 3) Develop and maintain a standard library for critical component analysis under flexible plant operations, which will include libraries of: process models, MI models for typical pressure parts, and economic models with typical plant operating data and ISO power trade data.

01 COAL, LIGNITE, AND PEAT↗

FLEXIBLE POWER TRANSFORMERS TO IMPROVE RESILIENCY OF TRANSMISSION NETWORKS

For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021

flexible transformer, resilient grid, variable lea↗

A physics-based parametric regression approach for feedwater pump system diagnosis

Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗

Hierarchical Flexibility Offering Strategy for Integrated Hybrid Resources in Real-time Energy Markets

This paper proposes a hierarchical model for determining the energy flexibility offering strategy of integrated hybrid resources (IHRs) in power distribution systems to participate in real-time energy markets. The proposed model utilizes the scalability, fast response time, and uncertainty observation of deep reinforcement learning (DRL) to overcome the scalability issue of operating numerous flexible resources and deliverability of energy flexibility to the real-time markets in the presence of the network constraints. To that end, the power distribution system is divided into multiple IHRs, where different types of flexible loads, energy storage systems, and solar plants with controllable inverters are operated through local IHR controllers, trained by deep deterministic policy gradient (DDPG) algorithm. Active power request and reactive power capacity of IHRs are then transmitted to a central flexibility controller, where a quadratic optimization model ensures the deliverability of the energy flexibility to the real-time energy market by satisfying the distribution network constraints. The proposed model is implemented on the 123-bus test power distribution system, demonstrating the capability of DRL-based hierarchical model for scalable operation of IHRs in order to offer deliverable energy flexibility to the real-time energy market.

Majidi, Majid↗