Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Diagnostic assessment of reservoir response to fracturing: a case study from Hydraulic Fracturing Test Site (HFTS) in Midland Basin

Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.

Energy & Fuels↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Analysis of Source Physics Experiment Explosion-Triggered Microseismicity Using the Back-Projection Method

A series of four chemical explosions were detonated in a deep borehole within the Yucca Flat Dry Alluvium Geology (DAG) at the Nevada National Security Site between 2018 and 2019. The two larger chemical explosions of 50 tons (DAG-2) and 10 tons (DAG-4) TNT equivalent yield triggered energetic aftershock sequences numbering 1392 and 347 microearthquakes, respectively, within the first 10 days. No significant aftershock activity was observed for the two smaller 1-ton explosions (DAG-1 and DAG-3). Here, we used a back-projection method based on travel-time migration and stacking of signal-to-noise ratio traces to detect, associate and locate aftershocks from a subset of 22-geophones within a larger 2 urn:x-wiley:21699313:media:jgrb54910:jgrb54910-math-0001 2 km seismic array surrounding the borehole. The aftershocks located within 300 m of the borehole and the depths were above the working points of 300 and 50 m depths of DAG-2 and DAG-4, respectively, ruling out triggering slip on geologic faults or disturbances beneath neighboring collapse craters. DAG-2 and DAG-4 aftershocks decayed at similar rates, with power-law exponents of p = 1.48 and p = 1.49, respectively. These decay rates are comparable to aftershocks sequences triggered by earthquakes and historical nuclear explosions at Yucca Flat. A smooth power-law aftershock decay within the first 10 days suggests a triggering mechanism from explosion generated stress relaxation due to the diffusion of high gas pressures in the cavity and radial fractures. A more random and episodic aftershock rate would be expected due to cavity collapse or falling rubble in chimney formation.

58 GEOSCIENCES↗

Dynamical Anyon Generation in Kitaev Honeycomb Non-Abelian Spin Liquids

Relativistic Mott insulators known as “Kitaev materials” potentially realize spin liquids hosting non-Abelian anyons. Motivated by fault-tolerant quantum-computing applications in this setting, we introduce a dynamical anyon-generation protocol that exploits universal edge physics. The setup features holes in the spin liquid, which define energetically cheap locations for non-Abelian anyons, connected by a narrow bridge that can be tuned between spin liquid and topologically trivial phases. We show that modulating the bridge from trivial to spin liquid over intermediate time scales—quantified by analytics and extensive simulations—deposits non-Abelian anyons into the holes with O(1) probability. The required bridge manipulations can be implemented by integrating the Kitaev material into magnetic tunnel junction arrays that engender locally tunable exchange fields. Combined with existing readout strategies, our protocol reveals a path to topological qubit experiments in Kitaev materials at zero applied magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron spectral measurements at the BNL NSLS-II synchrotron facility

During the first week of August 2022, Tim Gildea of Los Alamos National Laboratory’s (LANL) RP-SVS group performed a series of neutron spectral measurements at the National Synchrotron Light Source II (NSLS-II) 3GeV facility located at Brookhaven National Lab (BNL)1 . These measurements were conducted under Memorandum Purchase Order (MPO) 413911 with the objective of gaining an accurate understanding of the photoneutron fields generated under normal and selected fault conditions. The spectral data collected during the course of the study was analyzed at LANL and the results form the basis of this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transformational faulting in Mn 2 GeO 4 from olivine to wadsleyite structure: Implications for physical mechanism of deep-focus earthquakes

High-pressure and temperature deformation experiments interfaced with acoustic emission (AE) monitoring have been conducted to study transformational faulting in Mn 2 GeO 4 olivine, which transforms to the β phase, isostructural to wadsleyite. Metastable Mn 2 GeO 4 olivine exhibits a marked embrittlement behavior at temperatures between 800 and 1100 K, emitting numerous AEs. At each temperature, brittle deformation is characterized by a two-stage process: (1) a “preparation” stage with numerous diffusedly located low-magnitude AEs and large b values (>2), and (2) a failure stage where larger-magnitude AEs form a planar distribution with b values about 1. Microstructure analysis reveals extensive kink band development in olivine grains in the recovered samples. Kink band boundaries (KBBs), with a typical thickness of ∼100 nm, are filled with a nanometric β-Mn 2 GeO 4 “gouge”. A dense array of secondary shear localizations is often present within the kink bands, suggesting significant shear deformation therein. The combined observations suggest that faulting in metastable Mn 2 GeO 4 olivine is a self-similar process, from grain-scale to the sample-scale. Both observed embrittlement behavior and the microstructure of metastable Mn 2 GeO 4 olivine are essentially identical to those in Mg 2 GeO 4 olivine we have reported previously, indicating that the physical mechanism of faulting in metastable olivine is insensitive to the specific crystallographic structure of the high-pressure phase. The low b values (about 1) observed in the faulting process in our experiments are similar to those of deep focus earthquakes in cold subduction zones. Our observed mechanism explains deep focus seismicity in cold metastable mantle wedges, provided that the self-similarity assumption holds to geological scales.

58 GEOSCIENCES↗

Peak Ground Velocity Spatial Variability Revealed by Dense Seismic Array in Southern California

There are an infinite number of locations where seismic waves interact with Earth's surface, yet seismologists can only record a finite set of ground motions. This requires assumptions about how known measurements or predictions can be extrapolated to nearby locations. We test to what extent extrapolation is viable using an array of 1,108 geophones installed 10–20 m apart within a 0.36 km 2 study area for 1 month atop the San Jacinto Fault in Southern California. Measuring ground motions from 38 small local earthquakes, we observe peak ground velocity (PGV) variations up to 22% across the array. We find the basin structure consistently traps energy, amplifying the seismic velocities, and that the damaged region within the fault reduces the PGVs. Comparing surface and borehole measurements (148 m deep), we find PGVs recorded at the surface are 3–10 times greater than the measurements at depth. We attribute these differences to amplification from soft sediments within the basin. We show that by leveraging information from >1,000 measurements per earthquake the ground motion velocities can be tightly constrained. These results suggest the spatial extrapolation of PGVs in regions of known faults and basins, even across a small area, should be done with caution.

58 GEOSCIENCES↗

Pore Pressure Diffusion and Onset of Induced Seismicity

The Raton Basin of Southern Colorado and Northern New Mexico experienced a significant increase in seismicity over the last several decades, including two M5+ earthquakes. The increase in seismicity started soon after an increase in wastewater disposal associated with coal-bed methane production. Twenty-nine wastewater injection wells have operated in the Basin, with several high-rate injectors located within a kilometer of the most seismically active regions. We developed a pore pressure model to investigate the relationship between pore pressure diffusion and onset of induced seismicity, with an emphasis on the Trinidad fault zones. Our model indicates that sufficient pore pressure increase had accumulated on the northern extent of the Trinidad fault zone to induce seismicity at the time of early-stage seismic activity. The hydrogeologic architecture of the Basin played a key role in controlling pore pressure perturbation. The basal sedimentary interval with moderately low diffusivity restricted vertical pore pressure diffusion, creating a substantial lag time between wells becoming active and the expression of perturbation in the fault zones. The spatiotemporal relationship between early-stage seismicity and wastewater injection in conjunction with modeled pore pressures suggests that the early-stage seismicity in the Raton Basin was likely triggered by pore pressure diffusion.

58 GEOSCIENCES↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Refinements to the Graves–Pitarka Kinematic Rupture Generator, Including a Dynamically Consistent Slip-Rate Function, Applied to the 2019 Mw 7.1 Ridgecrest Earthquake

The main objective of this study is to develop physics–based constraints on the spatiotemporal variation of the slip–rate function using a simplified dynamic rupture model. First, we performed dynamic rupture modeling of the 2019 M w 7.1 Ridgecrest, California, earthquake, to analyze the effects of depth–dependent stress and material friction on slip rate. Then, we used our modeling results to guide refinements to the slip–rate function that were implemented in the Graves–Pitarka kinematic rupture generation technique. The dynamic ruptures were computed on a surface–rupturing, planar strike–slip fault that includes a weak (negative to low–stress–drop) zone in the upper 4 km of the crust. Below the weak zone, we placed high–stress–drop patches designed to mirror the large–slip areas seen in various rupture model inversions of the event. The locations of the high–stress–drop patches and the hypocenter were varied in multiple realizations to investigate how changing the dynamic conditions affected the resulting rupture kinematics, in particular, the slip rate. From these simulations, we observed a systematic change in the shape of the slip–rate function from Kostrov type below the weak zone to a predominantly symmetric shape within the weak zone, along with a depth–dependent reduction of peak slip rate. We generalized these shallow rupture features into a depth–dependent parametric variation of the slip–rate function and implemented it in the Graves–Pitarka kinematic rupture model generator. The performance of the updated kinematic approach was then verified in 0–4 Hz simulations of the M w 7.1 Ridgecrest earthquake, which showed that incorporating the depth–dependent variation in the shape of the slip–rate function improves the fit to the observed near–fault ground motions in the 0.5–3 s period range.

58 GEOSCIENCES↗

Seasonal and Long‐Term Groundwater Unloading in the Central Valley Modifies Crustal Stress

Abstract Changes in terrestrial water content cause elastic deformation of the Earth's crust. This deformation is thought to play a role in modulating crustal stress and seismicity in regions where large water storage fluctuations occur. Groundwater is an important component of total water storage change in California, helping to drive annual water storage fluctuations and loss during periods of drought. Here we use direct estimates of groundwater volume loss during the 2007–2010 drought in California's Central Valley obtained from high resolution Interferometric Synthetic Aperture Radar‐based vertical land motion data to investigate the effect of groundwater volume change on the evolution of the stress field. We show that GPS‐derived elastic load models may not capture the contribution of groundwater to terrestrial water loading, resulting in an underestimation of nontectonic crustal stress change. We find that groundwater unloading during the drought causes Coulomb stress change of up to 5.5 kPa and seasonal fluctuations of up to 2.6 kPa at seismogenic depth. We find that faults near the Valley show the largest stress change and the San Andreas fault experiences only ~40 Pa of Coulomb stress change over the course of a year from groundwater storage change. Annual Coulomb stress change peaks dominantly in the fall, when the groundwater level is low; however, some faults experience peak stress in the spring when groundwater levels are higher. Additionally, we find that periods of increased stress correlate with higher than average seismic moment release but are not correlated with an increase in the number of earthquakes. This indicates groundwater loading likely contributes to nontectonic loading of faults, especially near the Valley edge, but is not a dominant factor in modulation of seismicity in California because the amplitude of stress change declines rapidly with distance from the Valley. By carefully quantifying and spatially locating groundwater fluctuations, we will improve our understanding of what drives nontectonic stress and forces that modulate seismicity in California.

58 GEOSCIENCES↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Adaptive Fault Detection Based on Neural Networks and Multiple Sampling Points for Distribution Networks and Microgrids

Smart networks such as microgrid (MG) and active distribution networks (ADN) have been recently playing an important role in power system operation. The design and implementation of appropriate protection systems for such networks must be addressed, which imposes new technical challenges. This paper presents the implementation and validation aspects of an adaptive fault detection strategy based on neural networks (NNs) and multiple sampling points for ADN and MG. The solution is implemented on an edge device. Artificial NNs are used to derive a data-driven model that uses only local measurements to detect fault states of the network without the need for communication infrastructure. Multiple sampling points are used to derive a data-driven model, which allows the generalization considering the implementation in physical systems. The adaptive fault detector model is implemented on a Jetson Nano system, which is a single-board computer (SBC) with a small Graphic Processing Unit (GPU) intended to run machine learning loads at the edge. The proposed method is tested in a physical, real-life, low-voltage network located at Universidad del Norte, Colombia. This testing network is based on the IEEE-13 Node Test Feeder scaled down to 220 V. The validation in a simulation environment shows the accuracy and dependability above 99.6%, while the real-time tests show the accuracy and dependability of 95.5% and 100%, respectively. Without hard-to-derive parameters, the easy-to-implement embedded model highlights the potential for real-life applications.

42 ENGINEERING↗

Self‐Potential Tomography Preconditioned by Particle Swarm Optimization—Application to Monitoring Hyporheic Exchange in a Bedrock River

Abstract A self‐potential (SP) data‐inversion algorithm was developed and tested on an analytical model of electrical‐potential profile data attributed to single and multiple polarized electrical sources. The developed algorithm was then validated by an application to SP‐monitoring field data measured on the floodplain of East Fork Poplar Creek, Oak Ridge, Tennessee, to image electrical sources in areas conducive to preferential flow into the flood plain from the bedrock‐lined riverbed. The algorithm combined stochastic source‐localization by particle‐swarm‐optimization (PSO) of electrical sources characterized by simplified geometries with source tomography by regularized weighted least‐squares minimization of a quadratic objective function. Prior information was incorporated by preconditioning the tomography algorithm by PSO results. Variable percentages of random noise were added to analytical‐model data to evaluate the algorithm performance. Results indicated that true parameters of single‐source models were inverted and approximated with small residual error, whereas inversion of analytical‐model data representing multiple electrical sources accurately approximated the locations of the sources but miscalculated some parameters because of the non‐uniqueness of the inverse‐model solution. Source tomography applied to analytical model data during testing produced a spatially continuous parameter field that identified the locations of point‐scale synthetic dipole sources of electrical current flow with varying degrees of accuracy depending on the prior information incorporated into the tomography. When applied to SP‐monitoring field data, the algorithm imaged electrical sources within a known fault that intersects the bedrock riverbed and flood plain of East Fork Poplar Creek and depicted dynamic electrical conditions attributed to hyporheic exchange.

54 ENVIRONMENTAL SCIENCES↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Clifford Hierarchy Stabilizer Codes: Transversal Non-Clifford Gates and Magic States

A fundamental problem in fault-tolerant quantum computation is the tradeoff between universality and dimensionality, exemplified by the the Bravyi-König bound for $n$-dimensional topological stabilizer codes. In this work, we extend topological Pauli stabilizer codes to a broad class of $n$-dimensional Clifford hierarchy stabilizer codes. These codes correspond to the $(n+1)$D Dijkgraaf-Witten gauge theories with non-Abelian topological order. We construct transversal non-Clifford gates through automorphism symmetries represented by cup products. In 2D, we obtain the first transversal non-Clifford logical gates including T and CS for Clifford stabilizer codes, using the automorphism of the twisted $\mathbb{Z}_2^3$ gauge theory (equivalent to $\mathbb{D}_4$ topological order). We also combine it with the just-in-time decoder to fault-tolerantly prepare the logical T magic state in $O(d)$ rounds via code switching. In 3D, we construct a transversal logical $\sqrt{\text{T}}$ gate in a non-Clifford stabilizer code at the third level of the Clifford hierarchy, located on a tetrahedron corresponding to a twisted $\mathbb{Z}_2^4$ gauge theory. Furthermore, our constructions surpass the Bravyi-König bound by achieving the logical gates in the $(n+1)$-th level of Clifford hierarchy in $n$ spatial dimension.

Kobayashi, Ryohei [Institute for Advanced Study, P↗