Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Quantifying UAS Observation Error Variance Used in Data Assimilation Systems and Its Impact on Predictive Skill

Observation error determines the weights of the observations and background state used in data assimilation to generate analyses. Quantifying observation error is critical for the optimal assimilation of observational data sets. Uncrewed Aircraft System (UAS) observations have shown potential benefits in filling observational gaps in the lower atmosphere; however, characterization of their error characteristics has been limited. To optimize the use of UAS observations in numerical weather prediction, UAS observation error is estimated based on the 3‐cornered hat diagnostic approach which uses three independent estimates of the atmospheric state. This approach is applied to data from the 2018 Lower Atmospheric Profiling Studies at Elevation‐a Remotely‐piloted Aircraft Team Experiment field campaign using collocated UAS and rawinsonde observations along with output from a set of convection‐permitting model simulations. The estimated observation error values for UAS temperature, wind, and relative humidity measurements were found to be only weakly dependent on height AGL with mean values equal to 0.5°C, 0.8 m s −1 , and 3%, respectively. Only the newly estimated observation error for temperature differed from that previously used to assimilate commercial aircraft observations into global models (1.0°C). However, using this reduced temperature observation error produced more accurate mesoscale analyses and forecasts of both terrain‐driven flows and convection initiation generated by colliding outflow boundaries within the San Luis Valley of Colorado.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-94: Positioning Errors Resulting From Using Bony Anatomy Alignment for Treating SBRT Lung Tumor

Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning error on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.

60 APPLIED LIFE SCIENCES↗

SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-07: Development of Dose Calculation Error Predictors for a Widely Implemented Clinical Algorithm

Purpose: Several shortcomings of the current implementation of the analytic anisotropic algorithm (AAA) may lead to dose calculation errors in highly modulated treatments delivered to highly heterogeneous geometries. Here we introduce a set of dosimetric error predictors that can be applied to a clinical treatment plan and patient geometry in order to identify high risk plans. Once a problematic plan is identified, the treatment can be recalculated with more accurate algorithm in order to better assess its viability. Methods: Here we focus on three distinct sources dosimetric error in the AAA algorithm. First, due to a combination of discrepancies in smallfield beam modeling as well as volume averaging effects, dose calculated through small MLC apertures can be underestimated, while that behind small MLC blocks can overestimated. Second, due the rectilinear scaling of the Monte Carlo generated pencil beam kernel, energy is not properly transported through heterogeneities near, but not impeding, the central axis of the beamlet. And third, AAA overestimates dose in regions very low density (< 0.2 g/cm{sup 3}). We have developed an algorithm to detect the location and magnitude of each scenario within the patient geometry, namely the field-size index (FSI), the heterogeneous scatter index (HSI), and the lowdensity index (LDI) respectively. Results: Error indices successfully identify deviations between AAA and Monte Carlo dose distributions in simple phantom geometries. Algorithms are currently implemented in the MATLAB computing environment and are able to run on a typical RapidArc head and neck geometry in less than an hour. Conclusion: Because these error indices successfully identify each type of error in contrived cases, with sufficient benchmarking, this method can be developed into a clinical tool that may be able to help estimate AAA dose calculation errors and when it might be advisable to use Monte Carlo calculations.

60 APPLIED LIFE SCIENCES↗

SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement errors during the animal study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗

SU-F-T-310: Does a Head-Mounted Ionization Chamber Detect IMRT Errors?

Purpose: The conventional plan verification strategy is delivering a plan to a QA-phantom before the first treatment. Monitoring each fraction of the patient treatment in real-time would improve patient safety. We evaluated how well a new detector, the IQM (iRT Systems, Germany), is capable of detecting errors we induced into IMRT plans of three different treatment regions. Results were compared to an established phantom. Methods: Clinical plans of a brain, prostate and head-and-neck patient were modified in the Pinnacle planning system, such that they resulted in either several percent lower prescribed doses to the target volume or several percent higher doses to relevant organs at risk. Unaltered plans were measured on three days, modified plans once, each with the IQM at an Elekta Synergy with an Agility MLC. All plans were also measured with the ArcCHECK with the cavity plug and a PTW semiflex 31010 ionization chamber inserted. Measurements were evaluated with SNC patient software. Results: Repeated IQM measurements of the original plans were reproducible, such that a 1% deviation from the mean as warning and 3% as action level as suggested by the manufacturer seemed reasonable. The IQM detected most of the simulated errors including wrong energy, a faulty leaf, wrong trial exported and a 2 mm shift of one leaf bank. Detection limits were reached for two plans - a 2 mm field position error and a leaf bank offset combined with an MU change. ArcCHECK evaluation according to our current standards also left undetected errors. Ionization chamber evaluation alone would leave most errors undetected. Conclusion: The IQM detected most errors and performed as well as currently established phantoms with the advantage that it can be used throughout the whole treatment. Drawback is that it does not indicate the source of the error.

60 APPLIED LIFE SCIENCES↗

SU-F-T-381: Fast Calculation of Three-Dimensional Dose Considering MLC Leaf Positional Errors for VMAT Plans

Purpose: In this study, we developed a system to calculate three dimensional (3D) dose that reflects dosimetric error caused by leaf miscalibration for head and neck and prostate volumetric modulated arc therapy (VMAT) without additional treatment planning system calculation on real time. Methods: An original system called clarkson dose calculation based dosimetric error calculation to calculate dosimetric error caused by leaf miscalibration was developed by MATLAB (Math Works, Natick, MA). Our program, first, calculates point doses at isocenter for baseline and modified VMAT plan, which generated by inducing MLC errors that enlarged aperture size of 1.0 mm with clarkson dose calculation. Second, error incuced 3D dose was generated with transforming TPS baseline 3D dose using calculated point doses. Results: Mean computing time was less than 5 seconds. For seven head and neck and prostate plans, between our method and TPS calculated error incuced 3D dose, the 3D gamma passing rates (0.5%/2 mm, global) are 97.6±0.6% and 98.0±0.4%. The dose percentage change with dose volume histogram parameter of mean dose on target volume were 0.1±0.5% and 0.4±0.3%, and with generalized equivalent uniform dose on target volume were −0.2±0.5% and 0.2±0.3%. Conclusion: The erroneous 3D dose calculated by our method is useful to check dosimetric error caused by leaf miscalibration before pre treatment patient QA dosimetry checks.

60 APPLIED LIFE SCIENCES↗

Approaches to reducing photon dose calculation errors near metal implants

Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact reduction methods investigated, the authors found that O-MAR was the most consistent method, resulting in either improved dose calculation accuracy (dental case) or little impact on calculation accuracy (spine case). GSI was unsuccessful at reducing the severe artifacts caused by dental fillings and had very little impact on calculation accuracy. GSI with MARS on the other hand gave mixed results, sometimes introducing metal distortion and increasing calculation errors (titanium rectangular implant and titanium spinal hardware) but other times very successfully reducing artifacts (Cerrobend rectangular implant and dental fillings). Conclusions: Though successful at improving dose calculation accuracy upstream of metal implants, metal kernels were not found to substantially improve accuracy for clinical cases. Of the commercial artifact reduction methods investigated, O-MAR was found to be the most consistent candidate for all-purpose CT simulation imaging. The MARS algorithm for GSI should be used with caution for titanium implants, larger implants, and implants located near heterogeneities as it can distort the size and shape of implants and increase calculation errors.

60 APPLIED LIFE SCIENCES↗

A Framework for Error-Bounded Approximate Computing, with an Application to Dot Products

Approximate computing techniques, which trade off the computation accuracy of an algorithm for better performance and energy efficiency, have been successful in reducing computation and power costs in several domains. However, error sensitive applications in high-performance computing are unable to benefit from existing approximate computing strategies that are not developed with guaranteed error bounds. While approximate computing techniques can be developed for individual high-performance computing applications by domain specialists, this often requires additional theoretical analysis and potentially extensive software modification. Hence, the development of low-level error-bounded approximate computing strategies that can be introduced into any high-performance computing application without requiring additional analysis or significant software alterations is desirable. In this paper, we provide a contribution in this direction by proposing a general framework for designing error-bounded approximate computing strategies and apply it to the dot product kernel to develop \bf qdot---an error-bounded approximate dot product kernel. Following the introduction of qdot, here we perform a theoretical analysis that yields a deterministic bound on the relative approximation error introduced by qdot. Empirical tests are performed to illustrate the tightness of the derived error bound and to demonstrate the effectiveness of qdot on a synthetic dataset, as well as two scientific benchmarks---the conjugate gradient (CG) and power methods. In some instances, using qdot for the dot products in CG can result in many components being quantized to half precision without increasing the iteration count required for convergence to the same solution as CG using a double precision dot product.

97 MATHEMATICS AND COMPUTING↗

Better Than Worst-Case Decoding for Quantum Error Correction

The overheads of classical decoding for quantum error correction in cryogenic quantum systems grow rapidly with the number of logical qubits and their correction code distance. Decoding at room temperature is bottlenecked by refrigerator I/O bandwidth while cryogenic on-chip decoding is limited by area/power/thermal budget. To overcome these overheads, we are motivated by the observation that in the common case (over 90% of the time), error correction 'syndromes' are fairly trivial with high redundancy / sparsity, since the error correction codes are over-provisioned to be able to correct for uncommon worst-case complex scenarios (to ensure substantially low logical error rates). If suitably exploited, these trivial scenarios can be handled with insignificant overhead, thereby alleviating any bottlenecks towards handling the worst-case scenarios by state-of-the-art means. Here, we propose Better Than Worst-Case Decoding for Quantum Error Correction, targeting cryogenic quantum systems and Surface Code, consisting of: On-chip Clique Decoder: An extremely lightweight decoder for correcting trivial common-case errors, designed for the cryogenic domain. The decoder is implemented and evaluated for SFQ logic. Statistical Off-chip Bandwidth Allocation: A statistical confidence-based technique for allocation of off-chip decoding bandwidth, to efficiently handle the rare complex decodes that are not covered by the Clique Decoder. Decode-Overflow Execution Stalling: A method to stall circuit execution, for the worst-case scenarios in which the provisioned off-chip bandwidth is insufficient to complete all requested off-chip decodes. In all, BTWC decoding achieves 70-99+% off-chip bandwidth elimination across a range of logical and physical error rates, without significantly sacrificing the accuracy of a state-of-the-art off-chip decoder. Further, it achieves 10-1000x bandwidth reduction over prior bandwidth reduction techniques, as well as 15-37x resource overhead reduction compared to prior on-chip decoding.

cryogenic optimization↗

ADEPT, a dynamic next generation sequencing data error-detection program with trimming

Illumina is the most widely used next generation sequencing technology and produces millions of short reads that contain errors. These sequencing errors constitute a major problem in applications such as de novo genome assembly, metagenomics analysis and single nucleotide polymorphism discovery. In this study, we present ADEPT, a dynamic error detection method, based on the quality scores of each nucleotide and its neighboring nucleotides, together with their positions within the read and compares this to the position-specific quality score distribution of all bases within the sequencing run. This method greatly improves upon other available methods in terms of the true positive rate of error discovery without affecting the false positive rate, particularly within the middle of reads. We conclude that ADEPT is the only tool to date that dynamically assesses errors within reads by comparing position-specific and neighboring base quality scores with the distribution of quality scores for the dataset being analyzed. The result is a method that is less prone to position-dependent under-prediction, which is one of the most prominent issues in error prediction. The outcome is that ADEPT improves upon prior efforts in identifying true errors, primarily within the middle of reads, while reducing the false positive rate.

59 BASIC BIOLOGICAL SCIENCES↗

diffReplication - An Energy-Aware Fault Tolerance Model for Silent Error Detection and Mitigation in Heterogeneous Extreme-scale Computing Environment

At extreme scale, the frequency of silent errors – a class of errors that remain undetected by low-level error detection mechanisms – increases significantly with the computational complexity of the application and the scale of the computing infrastructure. As hardware and software advances are made to usher in the next scientific era of computing, developing new approaches to mitigate the impact of silent errors remains a challenging problem. In this work, we propose an energy-aware fault-tolerance model, referred to diffReplication to overcome silent errors. In the proposed model, the main process is associated with one replica that executes at the same rate as the main process, and one diffReplica that is executed at a fraction of the main process' execution rate. If the main and its replica reach consensus at the end of a computation phase, the state of the diffReplica is updated and computation is resumed. If the synchronization attempt results in a disagreement, however, the diffReplica increases its execution speed to complete the computation and quickly reach the synchronization barrier. Assuming a single error over any given synchronization interval, a majority voting is used to reach consensus and tolerate silent errors. To further enhance its performance, diffReplication is augmented with speculative execution, whereby the main or its fast replica is selected to continue execution without waiting for the diffReplica. The selection process is based on the previous behaviour of the main and its replica. A performance analysis study is carried out to assess the performance of diffReplication, in terms of the energy saving and time-to-completion reduction achieved by the diffReplication scheme. The experiment shows that speculative execution reduces the time to completion with additional energy, and dynamic decision-making balances the energy consumption and time to completion.

97 MATHEMATICS AND COMPUTING↗

Experimental demonstration of continuous quantum error correction

The storage and processing of quantum information are susceptible to external noise, resulting in computational errors. A powerful method to suppress these effects is quantum error correction. Typically, quantum error correction is executed in discrete rounds, using entangling gates and projective measurement on ancillary qubits to complete each round of error correction. Here we use direct parity measurements to implement a continuous quantum bit-flip correction code in a resource-efficient manner, eliminating entangling gates, ancillary qubits, and their associated errors. An FPGA controller actively corrects errors as they are detected, achieving an average bit-flip detection efficiency of up to 91%. Furthermore, the protocol increases the relaxation time of the protected logical qubit by a factor of 2.7 over the relaxation times of the bare comprising qubits. Our results showcase resource-efficient stabilizer measurements in a multi-qubit architecture and demonstrate how continuous error correction codes can address challenges in realizing a fault-tolerant system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Classifying handedness in chiral nanomaterials using label error robust deep learning

Abstract High-throughput scanning electron microscopy (SEM) coupled with classification using neural networks is an ideal method to determine the morphological handedness of large populations of chiral nanoparticles. Automated labeling removes the time-consuming manual labeling of training data, but introduces label error, and subsequently classification error in the trained neural network. Here, we evaluate methods to minimize classification error when training from automated labels of SEM datasets of chiral Tellurium nanoparticles. Using the mirror relationship between images of opposite handed particles, we artificially create populations of varying label error. We analyze the impact of label error rate and training method on the classification error of neural networks on an ideal dataset and on a practical dataset. Of the three training methods considered, we find that a pretraining approach yields the most accurate results across label error rates on ideal datasets, where size and other morphological variables are held constant, but that a co-teaching approach performs the best in practical application.

36 MATERIALS SCIENCE↗

Group-theoretic error mitigation enabled by classical shadows and symmetries

Abstract Estimating expectation values is a key subroutine in quantum algorithms. Near-term implementations face two major challenges: a limited number of samples required to learn a large collection of observables, and the accumulation of errors in devices without quantum error correction. To address these challenges simultaneously, we develop a quantum error-mitigation strategy called symmetry-adjusted classical shadows , by adjusting classical-shadow tomography according to how symmetries are corrupted by device errors. As a concrete example, we highlight global U(1) symmetry, which manifests in fermions as particle number and in spins as total magnetization, and illustrate their group-theoretic unification with respective classical-shadow protocols. We establish rigorous sampling bounds under readout errors obeying minimal assumptions, and perform numerical experiments with a more comprehensive model of gate-level errors derived from existing quantum processors. Our results reveal symmetry-adjusted classical shadows as a low-cost strategy to mitigate errors from noisy quantum experiments in the ubiquitous presence of symmetry.

Zhao, Andrew (ORCID:0000000202990277)↗

Error-Field Penetration Thresholds in Ohmically Heated ITER and SPARC Plasmas

The critical n=1, n=2, and n=3 error-field amplitudes needed to trigger error-field penetration in ITER and SPARC, steady-state, ohmically heated plasmas are calculated using a standard asymptotic matching approach. The calculation incorporates plasma impurities, trapped particles, the bootstrap current, and neoclassical poloidal flow-damping. The energy confinement time is specified by the neo-Alcator scaling law in the low-density linear ohmic confinement (LOC) regime, and by the ITER-89P L-mode scaling law in the high-density saturated ohmic confinement regime (SOC) regime. The response of the plasma in the inner region is calculated using a linearized version of the four-field model. At the normal operating electron number density, diamagnetic levels of rotation are found to be sufficient to protect ITER and SPARC ohmically heated plasmas from m=2/n=1 error-field penetration. On other hand, SPARC, and especially ITER, ohmically heated plasmas may be vulnerable to n>1 error-field penetration. ITER and SPARC ohmically heated plasmas are also slightly more susceptible to error-field penetration when the electron fluid at the rational surface rotates in the ion diamagnetic direction, rather than the electron diamagnetic direction. At electron number densities that are sufficiently low that the plasma lies in the LOC confinement regime, the error-field penetration threshold increases with increasing density. However, as soon as the electron number density becomes large enough that the plasma enters the SOC regime, the increase in the error-field penetration threshold with increasing density levels off.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing multiplicative error with lensing magnification of type Ia supernovae

Weak lensing causes spatially coherent fluctuations in the flux of Type Ia supernovae (SNe Ia). This lensing magnification allows for weak lensing measurement independent of cosmic shear. It is free of the shape measurement errors associated with cosmic shear and can therefore be used to diagnose and calibrate multiplicative error. Although this lensing magnification is difficult to accurately measure in auto correlation, its cross correlation with cosmic shear and galaxy distribution in an overlapping area can be measured to a significantly higher accuracy. Therefore, these cross correlations can put useful constraints on multiplicative error, and the obtained constraint is free of cosmic variance in the weak lensing field. We present two methods implementing this idea and estimate their performances. We find that, with ∼1 million SNe Ia that can be achieved with the proposed D2k survey with the LSST telescope, a multiplicative error of ∼0.5% for source galaxies at z{sub s}∼1 can be detected and a larger multiplicative error can be corrected to the level of 0.5%. It is therefore a promising approach to control the multiplicative error to the sub-percent level required for stage IV projects. The combination of the two methods even has the potential to diagnose and calibrate galaxy intrinsic alignment, which is another major systematic error in cosmic shear cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗