Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Enter Gaussian Mixture Modeling Extensions for Improved False Discovery Rate Estimation in GC-MS Metabolomics

Identifying small molecules (e.g., metabolites) is key towards driving scientific advancement in metabolomics, and gas chromatography–mass spectrometry (GC-MS) is an analytic method that may be applied to facilitate this process. The typical GC-MS identification workflow involves quantifying the similarity of an observed sample spectrum and other features (e.g. retention index) to that of several references, noting the compound of the best-matching reference spectrum as the identified metabolite. While a deluge of similarity metrics exists, none characterize the error rate of generated identifications, thereby presenting an unknown risk of false identification or discovery. To quantify this unknown risk, we propose a model-based framework for estimating the false discovery rate (FDR) among a set of identifications. Extending the traditional mixture modeling framework, our method incorporates both similarity score and experimental information in estimating the FDR. We apply these models to identification lists derived from across 548 samples of varying complexity and sample type (e.g., fungal species, standard mixtures, etc.), comparing their performance to that of the traditional Gaussian mixture model (GMM). Through simulation, we additionally assess the impact of reference library size on the accuracy of FDR estimates. In comparing the best performing model extensions to the GMM, our results indicate relative decreases in median absolute estimation error (MAE) ranging from 12% to 70%, based on comparisons of the median MAEs across all hit-lists. Results indicate that these relative performance improvements generally hold despite library size, however FDR estimation error typically worsens as the set of reference compounds diminishes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DISCOVERY OF A HIGHLY UNEQUAL-MASS BINARY T DWARF WITH KECK LASER GUIDE STAR ADAPTIVE OPTICS: A COEVALITY TEST OF SUBSTELLAR THEORETICAL MODELS AND EFFECTIVE TEMPERATURES

Highly unequal-mass ratio binaries are rare among field brown dwarfs, with the mass ratio distribution of the known census described by q {sup (4.9{+-}0.7)}. However, such systems enable a unique test of the joint accuracy of evolutionary and atmospheric models, under the constraint of coevality for the individual components (the 'isochrone test'). We carry out this test using two of the most extreme field substellar binaries currently known, the T1 + T6 {epsilon} Ind Bab binary and a newly discovered 0.''14 T2.0 + T7.5 binary, 2MASS J12095613-1004008AB, identified with Keck laser guide star adaptive optics. The latter is the most extreme tight binary resolved to date (q {approx} 0.5). Based on the locations of the binary components on the Hertzsprung-Russell (H-R) diagram, current models successfully indicate that these two systems are coeval, with internal age differences of log(age) = -0.8 {+-} 1.3(-1.0{sup +1.2}{sub -1.3}) dex and 0.5{sup +0.4}{sub -0.3}(0.3{sup +0.3}{sub -0.4}) dex for 2MASS J1209-1004AB and {epsilon} Ind Bab, respectively, as inferred from the Lyon (Tucson) models. However, the total mass of {epsilon} Ind Bab derived from the H-R diagram ({approx} 80 M{sub Jup} using the Lyon models) is strongly discrepant with the reported dynamical mass. This problem, which is independent of the assumed age of the {epsilon} Ind Bab system, can be explained by a {approx} 50-100 K systematic error in the model atmosphere fitting, indicating slightly warmer temperatures for both components; bringing the mass determinations from the H-R diagram and the visual orbit into consistency leads to an inferred age of {approx} 6 Gyr for {epsilon} Ind Bab, older than previously assumed. Overall, the two T dwarf binaries studied here, along with recent results from T dwarfs in age and mass benchmark systems, yield evidence for small ({approx}100 K) errors in the evolutionary models and/or model atmospheres, but not significantly larger. Future parallax, resolved spectroscopy, and dynamical mass measurements for 2MASS J1209-1004AB will enable a more stringent application of the isochrone test. Finally, the binary nature of this object reduces its utility as the primary T3 near-IR spectral typing standard; we suggest SDSS J1206+2813 as a replacement.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion velocities in the presheath of electronegative, radio-frequency plasmas measured by low-energy cutoff

Simple kinematic considerations indicate that, under certain conditions in radio-frequency (rf) plasmas, the amplitude of the low-energy peak in ion energy distributions (IEDs) measured at an electrode depends sensitively on ion velocities upstream, at the presheath/sheath boundary. By measuring this amplitude, the velocities at which ions exit the presheath can be determined and long-standing controversies regarding presheath transport can be resolved. Here, IEDs measured in rf-biased, inductively coupled plasmas in CF{sub 4} gas determined the presheath exit velocities of all significant positive ions: CF{sub 3}{sup +}, CF{sub 2}{sup +}, CF{sup +}, and F{sup +}. At higher bias voltages, we detected essentially the same velocity for all four ions. For all ions, measured velocities were significantly lower than the Bohm velocity and the electropositive ion sound speed. Neither is an accurate boundary condition for rf sheaths in electronegative gases: under certain low-frequency, high-voltage criteria defined here, either yields large errors in predicted IEDs. These results indicate that many widely used sheath models will need to be revised.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data assimilation for burnup distribution of PWR with three-dimensional variational algorithm and artificial neutral network

In this paper, a data-assimilation method has been proposed and applied for the burnup distribution of PWR. The burnup distribution is significant to the safety and economy of the reactor, as it is essential for the fuel-reloading design and optimization. Due to the burnup distribution cannot be measured directly during the reactor operation, the numerical simulation is widely applied to determine the burnup distribution. However, there is a deviation between the numerical simulation and the actual core due to some unavoidable factors, such as component manufacturing deviation, uneven flow distribution and so on. These differences would induce the errors to the simulation values of power distributions and hence to the burnup distribution. To address this problem, a data-assimilation method for the burnup distribution has been proposed with the application of power-distribution measurements. In our research, the three-dimensional variational (3DVAR) algorithm was applied for burnup-distribution calibration and the artificial neutral network (ANN) was applied to establish the relation between power distribution and corresponding burnup distribution. As engineering verification, the proposed data-assimilation method has been applied to the CNP1000 PWR operated in China. The numerical results indicated that the burnup-distribution errors can be reduced notably, as the maximum value of relative errors for power distribution can be reduced from 5.35% to 3.96%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Constraining primordial magnetic fields with future cosmic shear surveys

The origin of astrophysical magnetic fields observed in galaxies and clusters of galaxies is still unclear. One possibility is that primordial magnetic fields generated in the early Universe provide seeds that grow through compression and turbulence during structure formation. A cosmological magnetic field present prior to recombination would produce substantial matter clustering at intermediate/small scales, on top of the standard inflationary power spectrum. In this work we study the effect of this alteration on one particular cosmological observable, cosmic shear. We adopt the semi-analytic halo model in order to describe the non-linear clustering of matter, and feed it with the altered mass variance induced by primordial magnetic fields. We find that the convergence power spectrum is, as expected, substantially enhanced at intermediate/small angular scales, with the exact amplitude of the enhancement depending on the magnitude and power-law index of the magnetic field power spectrum. Specifically, for a fixed amplitude, the effect of magnetic fields is larger for larger spectral indices. We use the predicted statistical errors for a future wide-field cosmic shear survey, on the model of the ESA Cosmic Vision mission Euclid, in order to forecast constraints on the amplitude of primordial magnetic fields as a function of the spectral index. We find that the amplitude will be constrained at the level of ∼ 0.1 nG for n{sub B} ∼ −3, and at the level of ∼ 10{sup −7} nG for n{sub B} ∼ 3. The latter is at the same level of lower bounds coming from the secondary emission of gamma-ray sources, implying that for high spectral indices Euclid will certainly be able to detect primordial magnetic fields, if they exist. The present study shows how large-scale structure surveys can be used for both understanding the origins of astrophysical magnetic fields and shedding new light on the physics of the pre-recombination Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

DEEP WIDEBAND SINGLE POINTINGS AND MOSAICS IN RADIO INTERFEROMETRY: HOW ACCURATELY DO WE RECONSTRUCT INTENSITIES AND SPECTRAL INDICES OF FAINT SOURCES?

Many deep wideband wide-field radio interferometric surveys are being designed to accurately measure intensities, spectral indices, and polarization properties of faint source populations. In this paper, we compare various wideband imaging methods to evaluate the accuracy to which intensities and spectral indices of sources close to the confusion limit can be reconstructed. We simulated a wideband single-pointing (C-array, L-Band (1–2 GHz)) and 46-pointing mosaic (D-array, C-Band (4–8 GHz)) JVLA observation using a realistic brightness distribution ranging from 1 μ Jy to 100 mJy and time-, frequency-, polarization-, and direction-dependent instrumental effects. The main results from these comparisons are (a) errors in the reconstructed intensities and spectral indices are larger for weaker sources even in the absence of simulated noise, (b) errors are systematically lower for joint reconstruction methods (such as Multi-Term Multi-Frequency-Synthesis (MT-MFS)) along with A-Projection for accurate primary beam correction, and (c) use of MT-MFS for image reconstruction eliminates Clean-bias (which is present otherwise). Auxiliary tests include solutions for deficiencies of data partitioning methods (e.g., the use of masks to remove clean bias and hybrid methods to remove sidelobes from sources left un-deconvolved), the effect of sources not at pixel centers, and the consequences of various other numerical approximations within software implementations. This paper also demonstrates the level of detail at which such simulations must be done in order to reflect reality, enable one to systematically identify specific reasons for every trend that is observed, and to estimate scientifically defensible imaging performance metrics and the associated computational complexity of the algorithms/analysis procedures.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

A FIRST APPLICATION OF THE ALCOCK-PACZYNSKI TEST TO STACKED COSMIC VOIDS

We report on the first application of the Alcock-Paczynski test to stacked voids in spectroscopic galaxy redshift surveys. We use voids from the Sutter et al. void catalog, which was derived from the Sloan Digital Sky Survey Data Release 7 main sample and luminous red galaxy catalogs. The construction of that void catalog removes potential shape measurement bias by using a modified version of the ZOBOV algorithm and by removing voids near survey boundaries and masks. We apply the shape-fitting procedure presented in Lavaux and Wandelt to 10 void stacks out to redshift z = 0.36. Combining these measurements, we determine the mean cosmologically induced ''stretch'' of voids in three redshift bins, with 1{sigma} errors of 5%-15%. The mean stretch is consistent with unity, providing no indication of a distortion induced by peculiar velocities. While the statistical errors are too large to detect the Alcock-Paczynski effect over our limited redshift range, this proof-of-concept analysis defines procedures that can be applied to larger spectroscopic galaxy surveys at higher redshifts to constrain dark energy using the expected statistical isotropy of structures that are minimally affected by uncertainties in galaxy velocity bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Hot Deformation Characteristics and Processing Map of FV520B Martensitic Precipitation-Hardened Stainless Steel

Hot deformation characteristics of FV520B martensitic precipitation-hardened stainless steel were investigated in the temperature range of 850-1150 °C and strain rate range of 0.005-0.5 s{sup −1} with true strain 0.8 by using Gleeble-3500 thermo-mechanical simulator. Critical stress and corresponding critical strain for dynamic recrystallization initiation were calculated. The constitutive equation was developed by employing Arrhenius constitutive model to represent the nonlinear relationship of true stress and deformation parameters including temperature, strain rate and strain. The correlation coefficient and average absolute relative error are 0.9979 and 2.225%, which indicates the good predictive accuracy of the established constitutive equations. Processing maps were constructed at different plastic strains levels based on dynamic material model (DMM) and established constitutive equation. Combining the processing map with microstructure, the optimum region for good workability is designated as the temperature range of 1050-1125 °C and strain rate range of 0.027-0.23 s{sup −1} with peak efficiency of 0.32. Homogeneous fine and equiaxed dynamic recrystallization (DRX) grains can be found in this optimum according to the microstructure metallographic pictures.

36 MATERIALS SCIENCE↗

Uncoupling nicotine mediated motoneuron axonal pathfinding errors and muscle degeneration in zebrafish

Zebrafish embryos offer a unique opportunity to investigate the mechanisms by which nicotine exposure impacts early vertebrate development. Embryos exposed to nicotine become functionally paralyzed by 42 hpf suggesting that the neuromuscular system is compromised in exposed embryos. We previously demonstrated that secondary spinal motoneurons in nicotine-exposed embryos were delayed in development and that their axons made pathfinding errors (Svoboda, K.R., Vijayaraghaven, S., Tanguay, R.L., 2002. Nicotinic receptors mediate changes in spinal motoneuron development and axonal pathfinding in embryonic zebrafish exposed to nicotine. J. Neurosci. 22, 10731-10741). In that study, we did not consider the potential role that altered skeletal muscle development caused by nicotine exposure could play in contributing to the errors in spinal motoneuron axon pathfinding. In this study, we show that an alteration in skeletal muscle development occurs in tandem with alterations in spinal motoneuron development upon exposure to nicotine. The alteration in the muscle involves the binding of nicotine to the muscle-specific AChRs. The nicotine-induced alteration in muscle development does not occur in the zebrafish mutant (sofa potato, [sop]), which lacks muscle-specific AChRs. Even though muscle development is unaffected by nicotine exposure in sop mutants, motoneuron axonal pathfinding errors still occur in these mutants, indicating a direct effect of nicotine exposure on nervous system development.

60 APPLIED LIFE SCIENCES↗

Three-dimensional photogrammetric measurement of magnetic field lines in the WEGA stellarator

The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Orbital-optimized MP2.5 and its analytic gradients: Approaching CCSD(T) quality for noncovalent interactions

Orbital-optimized MP2.5 [or simply “optimized MP2.5,” OMP2.5, for short] and its analytic energy gradients are presented. The cost of the presented method is as much as that of coupled-cluster singles and doubles (CCSD) [O(N{sup 6}) scaling] for energy computations. However, for analytic gradient computations the OMP2.5 method is only half as expensive as CCSD because there is no need to solve λ{sub 2}-amplitude equations for OMP2.5. The performance of the OMP2.5 method is compared with that of the standard second-order Møller–Plesset perturbation theory (MP2), MP2.5, CCSD, and coupled-cluster singles and doubles with perturbative triples (CCSD(T)) methods for equilibrium geometries, hydrogen transfer reactions between radicals, and noncovalent interactions. For bond lengths of both closed and open-shell molecules, the OMP2.5 method improves upon MP2.5 and CCSD by 38%–43% and 31%–28%, respectively, with Dunning's cc-pCVQZ basis set. For complete basis set (CBS) predictions of hydrogen transfer reaction energies, the OMP2.5 method exhibits a substantially better performance than MP2.5, providing a mean absolute error of 1.1 kcal mol{sup −1}, which is more than 10 times lower than that of MP2.5 (11.8 kcal mol{sup −1}), and comparing to MP2 (14.6 kcal mol{sup −1}) there is a more than 12-fold reduction in errors. For noncovalent interaction energies (at CBS limits), the OMP2.5 method maintains the very good performance of MP2.5 for closed-shell systems, and for open-shell systems it significantly outperforms MP2.5 and CCSD, and approaches CCSD(T) quality. The MP2.5 errors decrease by a factor of 5 when the optimized orbitals are used for open-shell noncovalent interactions, and comparing to CCSD there is a more than 3-fold reduction in errors. Overall, the present application results indicate that the OMP2.5 method is very promising for open-shell noncovalent interactions and other chemical systems with difficult electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-based metallicity measurements at z = 0.8: Direct calibration of strong-line diagnostics at intermediate redshift

We present the first direct calibration of strong-line metallicity diagnostics at significant cosmological distances using a sample at z≃0.8 drawn from the DEEP2 Galaxy Redshift Survey. Oxygen and neon abundances are derived from measurements of electron temperature and density. We directly compare various commonly used relations between gas-phase metallicity and strong line ratios of O, Ne, and H at z≃0.8 and z = 0. There is no evolution with redshift at high precision (Δlog O/H=−0.01±0.03, Δlog Ne/O=0.01±0.01). O, Ne, and H line ratios follow the same locus at z≃0.8 as at z = 0, with ≲0.02 dex evolution and low scatter (≲0.04 dex). This suggests little or no evolution in physical conditions of H ii regions at fixed oxygen abundance, in contrast to models which invoke more extreme properties at high redshifts. We speculate that offsets observed in the [N ii]/Ha versus [O iii]/Hβ diagram at high redshift are therefore due to [N ii] emission, likely as a result of relatively high N/O abundance. If this is indeed the case, then nitrogen-based metallicity diagnostics suffer from systematic errors at high redshift. Our findings indicate that locally calibrated abundance diagnostics based on α-capture elements can be reliably applied at z≃1 and possibly at much higher redshifts. This constitutes the first firm basis for the widespread use of empirical calibrations in high redshift metallicity studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors

We demonstrate that a dual-layer, dual-color scintillator construct for microscopic CT, originally proposed to increase sensitivity in synchrotron imaging, can also be used to perform material quantification and classification when coupled with polychromatic illumination. We consider two different approaches to data handling: (1) a data-domain material decomposition whose estimation performance can be characterized by the Cramer-Rao lower bound formalism but which requires careful calibration and (2) an image-domain material classification approach that is more robust to calibration errors. The data-domain analysis indicates that useful levels of SNR (>5) could be achieved in one second or less at typical bending magnet fluxes for relatively large amounts of contrast (several mm path length, such as in a fluid flow experiment) and at typical undulator fluxes for small amount of contrast (tens of microns path length, such as an angiography experiment). The tools introduced could of course be used to study and optimize parameters for a wider range of potential applications. The image domain approach was analyzed in terms of its ability to distinguish different elemental stains by characterizing the angle between the lines traced out in a two-dimensional space of effective attenuation coefficient in the front and back layer images. As a result, this approach was implemented at a synchrotron and the results were consistent with simulation predictions.

36 MATERIALS SCIENCE↗

Quantum computation of phase transition in the massive Schwinger model

Abstract As pointed out by Coleman, physical quantities in the Schwinger model depend on a parameter θ that determines the background electric field. There is a phase transition for θ = π only. We develop a momentum space formalism on a lattice and use it to perform a quantum computation of the critical point of this phase transition on the NISQ device IMB Q Lima. After error mitigation, our results give strong indication of the existence of a critical point at m / e ≃ 0.32, where m is the bare fermion mass and e is the coupling strength, in good agreement with the classical numerical result m / e ≃ 0.3335.

Physics↗