Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Predictions of rhizosphere microbiome dynamics with a genome-informed and trait-based energy budget model

Abstract Soil microbiomes are highly diverse, and to improve their representation in biogeochemical models, microbial genome data can be leveraged to infer key functional traits. By integrating genome-inferred traits into a theory-based hierarchical framework, emergent behaviour arising from interactions of individual traits can be predicted. Here we combine theory-driven predictions of substrate uptake kinetics with a genome-informed trait-based dynamic energy budget model to predict emergent life-history traits and trade-offs in soil bacteria. When applied to a plant microbiome system, the model accurately predicted distinct substrate-acquisition strategies that aligned with observations, uncovering resource-dependent trade-offs between microbial growth rate and efficiency. For instance, inherently slower-growing microorganisms, favoured by organic acid exudation at later plant growth stages, exhibited enhanced carbon use efficiency (yield) without sacrificing growth rate (power). This insight has implications for retaining plant root-derived carbon in soils and highlights the power of data-driven, trait-based approaches for improving microbial representation in biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

Designing Harvesting and Hauling Cost Models for Energy Cane Production for Biorefineries

The harvesting and hauling operations of bioenergy feedstock is an important area in biofuel production. Production costs can be minimized by maintaining optimal machinery units for these operations. The objective of this study is to design an optimal harvesting unit for bioenergy refinery and estimate harvesting and hauling costs of energy cane. A biorefinery with the annual capacity of processing twenty-five million imp. gallons of ethanol were considered. Given the efficiency of harvesting, a two-row soldier system was considered. Considering the year-round supply of energy cane to the refinery, the optimal machinery unit was designed, and the combined operation costs were derived. The average estimated ownership, repair, labor and fuel and lubricant costs of biomass harvest unit were calculated to be $\$$0.50, $\$$0.54, $\$$1.78 and $\$$1.51/mt, respectively. The costs distribution generated showed harvesting and hauling costs could range between $\$$5.47–$\$$9.23/mt of energy cane. The methodology and the research output will provide guidelines for investors in designing harvesting and hauling units and estimating costs for different scales of operation.

09 BIOMASS FUELS↗

The Role of Energy Storage in the Uptake of Renewable Energy: A Model Comparison Approach

The power sector needs to ensure a rapid transition towards a low-carbon energy system to avoid the dangerous consequences of greenhouse gas emissions. Storage technologies are a promising option to provide the power system with the flexibility required when intermittent renewables are present in the electricity generation mix. This paper focuses on the role of electricity storage in energy systems with high shares of renewable sources. The study encompasses a model comparison approach where four models (GENeSYS-MOD, MUSE, NATEM, and urbs - MX) are used to analyse the storage uptake in North America. The analysis addresses the conditions affecting storage uptake in each country and its dependence on resource availability, technology costs, and public policies. Results show that storage may promote emissions reduction at lower costs when renewable mandates are in place whereas in presence of carbon taxes, renewables may compete with other low-carbon options. The study also highlights the main modelling approach shortcomings in the modelling of electricity storage in integrated assessment models.

electricity storage↗

Simple Building Calculator

Whole building energy modeling is a powerful tool for analyzing energy use in buildings. For large buildings benefits of modeling services can easily be quantified due to the short payback period of the implemented measures. For small buildings, the upfront costs of developing robust energy models often deter building owners from investing in energy modeling services. To address this shortcoming, a ”Simple Building Calculator” (SBC) was developed. SBC uses pre-simulated results of a range of common measures over a wide range of efficiency inputs. It combines whole building simulation results with statistical modeling techniques to predict energy impact of measures very quickly. In this paper we present the modeling methodology used to develop the data supporting SBC.

Building Energy Simulation, commercial building, E↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling distributed energy resource aggregations in security constrained unit commitment and economic dispatch

The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.

aggregations↗

Route Energy Prediction (RouteE) Powertrain Validation Report

The National Renewable Energy Laboratory's flagship package in the RouteE suite, RouteE-Powertrain, is a mesoscopic energy model that predicts vehicle energy consumption given discrete attributes that describe each segment or link in a vehicle's path on a road network. High-frequency, physics-based, powertrain simulators, such as NREL's FASTSim, are well-suited to model vehicle energy consumption when real driving data and a detailed understanding of the vehicle powertrain specifications are available. However, there are a variety of situations in the past, present (real-time), and future where high-frequency driving data and/or vehicle information may not be available, but reliable energy consumption is still desired, such as energy-aware vehicle routing. These are the ideal applications for RouteE-Powertrain. The suite of RouteE tools also includes RouteE-Compass, which is an eco-routing software that incorporates energy consumption into network routing algorithms, and RouteE-Mobile, which is a prototype smartphone navigation app to demonstrate the integrated capabilities of the RouteE suite for real-world eco-routing. The focus of this validation report is to share key metrics about the data sets and models behind RouteE-Powertrain. The set of RouteE-Powertrain models discussed in this report are made available through the RouteE web API through the NREL Developer Network.

33 ADVANCED PROPULSION SYSTEMS↗

MEPHESTO: Modeling Energy-Performance in Heterogeneous SoCs and Their Trade-Offs

Integrated shared memory heterogeneous architectures are pervasive because they satisfy the diverse needs of mobile, autonomous, and edge computing platforms. Although specialized processing units (PUs) that share a unified system memory improve performance and energy efficiency by reducing data movement, they also increase contention for this memory since the PUs interact with each other. Prior work has investigated performance degradation due to memory contention, but few have studied the relationship of power and energy to memory contention. Moreover, a comprehensive solution that models memory contention for kernel placement on contemporary heterogeneous systems on chip (SoCs) in response to energy and performance has been largely unaddressed.This paper presents MEPHESTO, a novel and holistic approach for managing this balance. The authors characterize applications and PUs in terms of two memory contention factors - time factors and power factors - to achieve the desired trade-off between energy and performance for collocated kernel execution on heterogeneous systems. The authors believe that this investigation is the first to combine all of these factors and present a simple knob-based approach that expresses the target trade-off. The approach is evaluated on a diverse integrated shared memory heterogeneous system with a CPU, GPU, and programmable vision accelerator. By using an empirical model for memory contention that provides up to 92% accuracy, the kernel collocation approach can provide a near-optimal ordering and placement based on the user-defined, energy-performance trade-off parameter. Moreover, the dynamic programming-based heuristics provide up to 30% better energy or 20% performance benefits when compared with the greedy approaches commonly employed by previous studies.

Alaul haque monil, Mohammad↗

Simplified Performance Rating Method - Review of Existing Tools, Rulesets, and Programs. Literature and technical review

The Performance Rating Method (PRM) in ASHRAE Standard 90.1 (ASHRAE 2016) is a simulation ruleset for establishing minimum code compliance and for rating a building’s beyond-code applications. Building energy modeling (BEM) to comply with the PRM is often expensive and time consuming due to the complexity of code requirements. The goal of this project is to develop and codify a simplified PRM (S-PRM) approach for commercial buildings that will expand the use of BEM for small or simple buildings by defining a low-cost, simplified approach for creating robust and detailed models. This report summarizes a review of (i) the more commonly used existing codes, (ii) incentive programs, and (iii) the existing simplified energy modeling tools to identify which requirements are good candidates for simplification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of carbon dioxide removal technologies on deep decarbonization: EMF37 MARKAL–NETL modeling results

Here this paper examines the MARKAL-NETL modeling results for the Energy Modeling Forum Study on Deep Decarbonization & High Electrification Scenarios for North America (EMF 37) with specific focus on carbon dioxide removal (CDR) technologies and opportunities under different scenarios guidelines, policies, and technological advancements. The results demonstrate that CDR, such as, bioenergy with carbon capture and storage (BECCS), direct air capture (DAC) and afforestation are key negative emission technologies in deep decarbonization scenarios in the U.S. are accounted for about 70% of annually avoided carbon dioxide emissions (CO 2 ) by 2050, or more than 2 billion tons of CO 2 (GtCO 2 ). The potential scale of CDR and its impact on the energy system depends on energy supply and demand technologies advancement and their costs, the level of end-use sectors electrification, availability and costs of CDR. Results show that the carbon prices are substantially lower if the advanced technologies available, particularly, in carbon management scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effective traplike activated dynamics in a continuous landscape

In this work, we use a simple model to extend network models for activated dynamics to a continuous landscape with a well-defined notion of distance and a direct connection to many-body systems. The model consists of a tracer in a high-dimensional funnel landscape with no disorder. We find a nonequilibrium low-temperature phase with aging dynamics that is effectively equivalent to that of models with built-in disorder, such as the trap model, step model and random energy model. Finally, we compare entropy with energy-driven activation, and we remark that the former is more robust to the choice of the dynamics since it does not depend on whether one uses local or global updates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Survey of Advanced Generation IV Reactor Parameters for Integrated Energy System Modeling Capabilities

This paper is to categorize and characterize advanced Generation IV nuclear reactors that are not water based according to the key parameters for the Integrated Energy Systems (IES) project[1]. A key goal of the IES project is to assess the economic viability of including an advanced nuclear reactor into an IES. The landscape of advanced reactors is heterogeneous: several unique designs with different heat profiles are currently being studied and designed. This report provides a high-level perspective of advanced reactor concepts, including primary loop nuclear output temperatures and operation schemes that could affect secondary side power production or storage. For example, this report addresses the type of thermodynamic system (Brayton, supercritical CO 2 [S-CO 2 ], etc.) and the various pressures and temperatures on the secondary side that are expected to be provided by the various primary side reactor types. Based on these characteristics, it may be possible to determine which type of nuclear power plant could be the most economical for analysis in the IES framework for power production coupled with energy storage and waste heat utilization. The results of this effort will serve as input for model development of various secondary side components, concentrating on off-the-shelf capabilities for current and near future secondary side power generation and heat rejection as simulated in TRANSFORM. Generic models can be created which are agnostic of the nuclear energy supply without violating intellectual property rights of the developer. These models can be used to make informed decisions on the economics of integrating various energy system components with nuclear plant designs. Once complete, conclusions may be drawn regarding (1) the economics, efficiency, and reliability of certain nuclear reactors, (2) certain industry processes and energy storage systems, and (3) prioritization of certain reactor types with the studied industry types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ray-based cross-beam energy transfer modeling for broadband lasers

Broadband lasers have the potential to mitigate cross-beam energy transfer (CBET) in direct-drive inertial confinement fusion (ICF) experiments. Furthermore, a quantitative assessment of the bandwidth required for CBET mitigation necessitates the development of broadband ray-based CBET models that can be implemented in the radiation-hydrodynamic codes that are used to design ICF experiments. Two different approaches to broadband ray-based CBET modeling (discrete and fixed spectrum) are developed and compared to wave-based calculations. Both approaches give good agreement with wave-based calculations in ICF-relevant configurations. Full-scale 3D calculations show that the bandwidth required for adequate CBET mitigation increases with increasing scale and drive intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗