Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Re-evaluating the Thermal-Spectrum Molten-Salt Breeder Reactor Fuel Cycle in a Modern Context

The current need to rapidly and substantially expand clean power production combined with limited capability for domestic uranium enrichment results in a U.S. nuclear power production planning environment similar to that of the first nuclear era. The U.S. thermal-spectrum molten-salt breeder reactor (TS-MSBR) program emerged during the first nuclear era as means to support rapid nuclear power expansion while minimizing demand on fissile resources. The primary reasons that the TS-MSBR program was discontinued in the 1970s were the comparatively large amount of required effort to mature its technology sufficiently for commercial deployment and the access to separated fissile material provided by the design of its integrated fuel cycle. The slowdown in U.S. electrical load growth after 1980 and the abundance of inexpensive fossil fuels inhibited reconsideration of TS-MSBR development for decades. The purpose of this discussion is to re-examine the value and technical challenges of TS-MSBRs with integrated fuel salt chemical processing considering the renewed need for rapid expansion of clean energy production worldwide, the current state of technology, the challenge of actinide wastes, and the continuing need to maintain a high degree of proliferation resistance and to integrate safeguards into the design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sustainable Solar Energy for Hughes Village (Hudotl’eekkaakk’e Tribe) (Final Technical Report)

Hughes Village Council is the local Tribal government for Hughes, Alaska. With the funding from this project, the Village Council designed and installed a 120kW solar Photo Voltaic (PV) array with a 250 kW/335kWh lithium-ion battery bank that has offset diesel consumption in the community by an estimated 10% per year. This translates to approximately 6,000 gallons of fuel per year. The goal is to reduce diesel consumption and turn the diesel generators off for certain periods of the Alaskan summer when solar PV is abundant and electrical loads in the community are low. Daily generator logs from the community show an average load of approximately 50kW-60kW with peaks ranging from 100kW-160kW. This project aligns with the tribe’s mission to work towards tribal energy sovereignty, utilizing sustainable energy technologies, and their overall goal of 25% clean energy by 2025.

14 SOLAR ENERGY↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Power Plants and Distributed Energy Resource Management Systems

Virtual Power Plants (VPPs) are aggregations of DERs that can balance electrical loads and provide utility-scale and utility-grade grid services like a traditional power plant. This presentation covers VPP definition, State-of-the-Art, Grid Architectures, Example VPP studies, VPP Standards, and VPP Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a System Interface for Flexible Thermal Power Extraction from Two Advanced Reactors

This report presents the design of system interfaces enabling flexible thermal power extraction from two advanced nuclear reactor concepts: a sodium-cooled fast reactor (SFR) operating on a Rankine cycle, and a gas-cooled reactor (GCR) utilizing a Brayton cycle. The study addresses the dual challenge of ensuring reliable base-load electricity generation while meeting the variable high-temperature steam demands of industrial processes (IPs).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hanover LED Streetlight Conversion

On May 8, 2017, Hanover residents voted overwhelmingly to transition to 100% renewable electricity by 2030 and heating, cooling and transportation by 2050. In so doing, we became the first municipality in the country to make this commitment by popular vote. To accomplish these goal town leaders developed a plan to address first transitioning municipal energy uses to renewable forms of energy, through on-site generation of the municipal electrical load, load reduction through energy efficiency improvements to town facilities and infrastructure. Significant progress has been accomplished in the generation of energy with 90%+ of the 2024 municipal load being offset by generation and through various energy efficiency projects. The utility owned street lighting was identified as a large energy consumer of 165 MWh annually (7% of the annual municipal load) due to old inefficient high-pressure sodium and mercury vapor streetlights with no ability to reduce wattage during periods with low lighting needs. The Hanover LED Streetlight Replacement Project replaced utility owned streetlights with town owned controllable (dimmable and trimmable) LED lights that can be adjusted by location and time of night. Coupled with ownership of the streetlights transfer to the town, the town’s share of the project pay back is 11 months and for the complete project including federal share the payback is approximately 3 years. With the completion of lighting upgrade, the annual streetlighting energy load has dropped by 60% to 67 MWh in the first year of operation (7/1/24 - 6/30/25). This amounts to an approximate $90,000 annual savings or a local 1% tax rate impact. Additionally, over 200,000 pounds of CO2 will be saved annually.

99 GENERAL AND MISCELLANEOUS↗

Use Case Specification

Over the past three years, the Use Case Specification project has provided scenarios that have driven the development of key E-COMP capabilities and demonstrated their application to problems that the electric power industry is facing. These scenarios have provided the basis for which each Thrust has performed technical work, tying together E-COMP work under a common umbrella. Documented in this report is a summary of the background, motivations, and work – completed or proposed – under the three E-COMP use cases pursued to date: Offshore Wind, Remote Communities on the Olympic Peninsula, and Large Electric Loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defining Power Efficient Residential Electric Appliances and Equipment

While the long-established concept of "energy efficiency" has successfully reduced energy consumption and bills in homes, it is no longer sufficient to address the modern challenges of electrical load growth, infrastructure upgrades and associated affordability challenges. We introduce the concept of “power efficiency” for household appliances and equipment, providing a framework to support affordable home modernization and grid management. Energy efficiency is the measure of energy used (kWh) to provide comfort/conveniences, power efficiency is the measure of power used (kW) to provide those same comforts/conveniences. Energy efficiency was needed because energy is a limited resource and expensive. Now power efficiency is needed because power delivery into a building is a limited resource and expensive. We propose a new set of metrics for defining and measuring power efficiency by investigating how current appliance nameplate ratings are established, and assessing the availability and use of existing data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunity Assessment for U.S. Industry: Energy-Efficient Cooling Technologies in Mexico

Mexico's rapidly expanding room air conditioner (AC) market presents a strategic opportunity for U.S. manufacturers to strengthen North American supply chains while addressing critical energy infrastructure challenges. With demand for room AC units in residential and commercial buildings projected to drive a 26 GW increase in Mexico’s peak electrical load by 2050, high-efficiency air conditioning systems offer both substantial market opportunities and essential grid stability benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Development of reliability prediction technique for semiconductor diodes

New fundamental technique of reliability prediction for semiconductor diodes based on realistic mathematical models can be applied to component failure rate prediction including mechanical degradation, electrical degradation, environmental stress factors, and electrical load stress factors.

Ryerson, C. M.↗

Closed-loop Dynamics of In-core Thermionic Reactor Systems

Using a point model of an in-core thermionic converter, alternative schemes for providing closed loop reactor control were investigated. It was found that schemes based on variable gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small-even for a complete electric load drop the emitter temperature transient is less than 100 deg K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that even though the emitter temperature distribution is about 200 deg K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗

A hybrid electrical power system for aircraft application.

Possible improvements to present aircraft electrical power systems for use in future advanced types of aircraft have been investigated. The conventional power system is examined, the characteristics of electric loads are reviewed, and various methods of power generation and distribution are appraised. It is shown that a hybrid system, with variable-frequency generation and high-voltage dc distribution, could overcome some of the limitations of the conventional system.

Lee, C. H.↗

Closed loop dynamics of in-core thermionic reactor systems.

Use of a point model of an in-core thermionic converter to investigate alternative schemes for providing closed-loop reactor control. It was found that schemes based on variable-gain power regulation buffers which use the reactor current as the control variable provide complete protection from thermionic burnout and also provide a virtually constant voltage to the user. A side benefit is that the emitter temperature transients are small; even for a complete electric load drop the emitter temperature transient is less than 100 K. The current regulation scheme was selected for further study with a distributed parameter model which was developed to account for variations in thermionic and heat transfer properties along the length of a cylindrical converter. It was found that, even though the emitter temperature distribution is about 200 K along the converter length, the dynamic properties are unchanged when using the current control scheme.

Sawyer, C. D.↗