Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ducts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MOOSE-Based Fast Reactor Core Bowing Capabilities: Coupled Structural Mechanics – Thermal Fluids Demonstration and Related Verification Efforts

Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism in liquid metal-cooled fast reactors and involves multiphysics effects including radiation transport, fluid flow, heat transfer, and mechanical response to temperature and flux gradients. Verification and assessment efforts continued on the Multiphysics Object Oriented Simulation Environment (MOOSE) capabilities relevant for modeling thermo-mechanical core bowing behavior. IAEA Verification Problem 4, which was started in FY23, was further examined with MOOSE capabilities to rectify discrepancies observed in previous years when compared to IAEA benchmark participant data. Meshing and postprocessing capabilities in MOOSE were also advanced by other teams and utilized this year. A thermal fluids-structural mechanical coupling demonstration has performed on 7-assemblyand 19-assembly fast reactor assembly configurations using MOOSE. Subchannel capabilities are used to calculate coolant temperature, and heat conduction capabilities calculate duct wall temperature as well as heat transfer through the inter-assembly gap. Structural mechanical capabilities then deform the mesh, accounting for contact between assemblies, according to the temperature gradients calculated by the thermal solvers. Power distributions are imposed rather than calculated to demonstrate different deformations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Arctic Ocean Hydroacoustics

As the Arctic warms and loses its perennial ice cover, it is becoming more attractive for a variety of human uses. Hydroacoustic monitoring of this activity will grow in importance over the coming years and decades. Changes to the physical environment affect acoustic propagation and noise, with ramifications for our ability to detect and locate events and activities of interest. In this report, we use two long-term data sets from the Beaufort Sea, western Arctic Ocean, to determine how acoustic propagation conditions and seismic source detections are impacted by the changing environment: 1) oceanographic observations from ice-tethered profilers, and 2) passive acoustic recordings from a hydrophone. We find that changes to Beaufort Sea thermohaline stratification is stabilizing a subsurface duct, leading to more focused acoustic energy arrivals. Detections of catalogued submarine earthquakes show geographic differences in signal strength between seismic and acoustic waves. Signal strength increases with earthquake magnitude, but relationships to other source and path factors are less clear. Ambient noise also has clear seasonal patterns in the Arctic, with relatively low noise in the spring, higher noise near 1 Hz in summer, and higher noise near 10 Hz in winter. Climate change is expected to modify these seasonal noise patterns, impacting event detection. Future work will further investigate the mechanisms of ice effects on sound and couple acoustic modeling to an Earth System Model.

54 ENVIRONMENTAL SCIENCES↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

Mixing-Controlled Compression Ignition Combustion with Low-Lifecycle-CO 2 Fuels

Reducing lifecycle carbon-dioxide (CO 2 ) and toxic emissions via electrification or switching to carbon-free fuels is not currently feasible for many off-road, rail, and marine applications. This is due to factors including excessive cost, weight, or size of a battery of sufficient capacity to meet the application requirements, lack of infrastructure, insufficient time for recharging, demanding duty cycles, and severe ambient conditions. The guiding vision for the activities described herein is to enable rapid, cost-effective reductions of the environmental impacts of such applications by using improved, high efficiency engine combustion strategies with currently available and emerging low lifecycle-CO 2 fuels (LLCFs). This report summarizes progress toward achieving this vision in two project areas. The first is a Technology Commercialization Fund (TCF) project focused on facilitating the commercialization of ducted fuel injection (DFI) with LLCFs. The second is a more fundamental, Advanced Combustion Engines (ACE) research project focused on elucidating a new strategy called lean mixing-controlled combustion (LMCC) for use with emerging LLCFs.

33 ADVANCED PROPULSION SYSTEMS↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Arcing Fault (HEAF) Photometrics 2022 Test Report

High Energy Arcing Faults (HEAFs) are hazardous events in which an electrical arc leads to the rapid release of energy in the form of heat, vaporized metal, and mechanical force. In Nuclear Power Plants, these events are often accompanied by loss of essential power and complicated shutdowns. To confirm the probabilistic risk analysis (PRA) methodology in NUREG/CR-6850, which was formulated based on limited observational data, the NRC led an international experimental campaign from 2014 to 2016. The results of these experiments uncovered an unexpected hazard posed by aluminum components in or near electrical equipment and the potential for unanalyzed equipment failures. Sandia National Laboratories (SNL), in support of the NRC work, collaborated with NIST, BSI, KEMA, and NRC to support the full-scale HEAF test campaign in 2022. SNL provided high speed visible and infrared video/data of ten tests that collected data from HEAFs originated on copper and aluminum buses inside switchgears and bus ducts. Part of the SNL scope was to place cameras with high-speed data collection at different vantage points within the test facility to provide NRC a more complete and granular view of the test events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Code Standard Evaluation for ASME AG-1-2019, Section FL

ASME AG-1 Section FL Deep Bed Sand Filters includes a requirement to use Special Test Sections to provide a representative assessment of the filter efficiency. The SRPPF project design basis is to test the entire filter bed (versus a representative sample) following the same basis methodology to test the existing filters at the Savannah River Site. Using a combination of: 1) the filter testing experience at SRS since the early 1970’s, 2) the methodology found in ASME AG-1 for testing high capacity HEPA filter housings and 3) requirements for stack or duct sampling systems published by the Environmental Protection Agency (EPA), the Special Test Sections methodology for Deep Bed Sand (DBS) filters in ASME AG-1 Section FL has been replaced with a methodology to test the entire DBS filter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancement of PyARC for Westinghouse Electric Company’s Lead Fast Reactor Design and Modeling (Final TCF Report)

Westinghouse Electric Company is a nuclear reactor vendor headquartered in the U.S. that is developing advanced reactor technology for the U.S. and global markets. Westinghouse has been relying on the neutronics Argonne Reactor Codes (ARC) executed through the NEAMS Workbench and its PyARC module that are developed under the DOE-NE Nuclear Energy Advanced Modeling and Simulation (NEAMS) and Advanced Reactor Technology (ART) – Fast Reactor programs. Through this user experience, Westinghouse identified several enhancements that would benefit the ARC codes’ usability by the US industry and therefore its commercialization potential. The enhancements were proposed to deliver both improvements in workflow and analysis capabilities to better support effective fast reactor core design and analysis to the nuclear industry. The PyARC workflow was extended in this project by integrating non-neutronic ARC codes DASSH and NUBOW-3D. The Ducted Assembly Steady-State Heat equation (DASSH) code is developed at ANL to perform steady-state thermal hydraulic sub-channel analysis in liquid metal fast reactor assemblies to determine optimized coolant flow and temperature distributions, which in this project was updated and validated for lead fast reactor (LFR) applications. The interface between REBUS and NUBOW-3D were improved in this project to assess the impact of the core restraint design and thermal induced expansion effects on the reactivity of the core, and to model the deformations of the fuel assemblies induced by temperature and irradiation. Finally, the ARC models that were extensively verified and validated through various SFR-based modeling benchmarks are extended in this project through code-to-code comparison on relevant LFR-specific neutronics benchmarks against Monte-Carlo neutronic solutions. Overall, this work enables verification of the capability of the ARC codes for a wide range of Generation-IV reactor designs. The outcome of this project is the release of a comprehensive modeling toolkit of validated, robust and efficient codes, as well as their user interface, that enables industry to perform a wide range of fast reactor analyses for design and licensing of their concepts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

THERMS Technology Commercialization Fund Final Report

The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.

25 ENERGY STORAGE↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY26 Progress on Demonstration of a Multiphysics Steady State Capability for Modeling Core Radial Expansion in SFRs

Under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism in liquid metal-cooled fast reactors and involves multiphysics effects including radiation transport, fluid flow, heat transfer, and mechanical response to temperature and flux gradients. This report summarizes recent progress on developing a multiphysics, MOOSE-based workflow to predict core bowing and associated reactivity feedback. Significant new capabilities in the reactor physics code Griffin - sodium backfill and pin power reconstruction for deformed geometries - were applied in this effort. This year’s work included verification, code comparisons, sensitivity studies, and coupled demonstrations that advance the state of MOOSE-based core bowing workflow. Griffin’s sodium backfill capability was verified by demonstrating that its automated treatment of geometry expansion and material-density updates reproduces manual calculations exactly, confirming solid mass conservation and proper coolant backfilling in expanded geometries. Reconstructed pin powers were compared for Griffin’s ductheterogeneous and ring-heterogeneous treatments in single-, seven-, and nineteen-assembly cases, with best agreement observed in lower-leakage configurations and the duct-heterogeneous approach offering substantially lower computational cost. Thermal-hydraulic sensitivity sensitivities showed that MOOSE SCM, SAM, and CFD are expected to produce similar deformation predictions despite variances in their temperature predictions, and that explicit treatment of inter-assembly flow becomes increasingly important as gap flow rate increases. Finally, coupled demonstrations on small multi-assembly configurations using Griffin, MOOSE Solid Mechanics, MOOSE SCM, and Heat Conduction produced physically consistent reactivity feedback from thermal expansion and bowing. The coupled demonstrations simulated grid plate expansion as well as resultant core bowing at full power conditions. Simplifications were made in current workflow, namely the assumption of instantaneous full power conditions following hot zero power, and pre-expanding the Griffin geometry axially due to lack of an axial fuel pin expansion model and temperature feedback to Griffin.

Wozniak, Nicholas↗

Molecular and morphological characterization of Tylenchus zeae n. sp. (Nematoda: Tylenchida) from Corn ( Zea mays ) in South Carolina

Specimens of a tylenchid nematode were recovered in 2019 from soil samples collected from a corn field, located in Pickens County, South Carolina, USA. A moderate number of Tylenchus sp. adults (females and males) were recovered. Extracted nematodes were examined morphologically and molecularly for species identification, which indicated that the specimens of the tylenchid adults were a new species, described herein as Tylenchus zeae n. sp. Morphological examination and the morphometric details of the specimens were very close to the original descriptions of Tylenchus sherianus and T. rex. However, females of the new species can be differentiated from these species by body shape and length, shape of excretory duct, distance between anterior end and esophageal intestinal valve, and a few other characteristics given in the diagnosis. Males of the new species can be differentiated from the two closely related species by tail, spicules, and gubernaculum length. Cryo-scanning electron microscopy confirmed head bearing five or six annules; four to six cephalic sensilla represented by small pits at the rounded corners of the labial plate; a small, round oral plate; and a large, pit-like amphidial opening confined to the labial plate and extending three to four annules beyond it. Phylogenetic analysis of 18S rRNA gene sequences placed Tylenchus zeae n. sp. in a clade with Tylenchus arcuatus and several Filenchus spp., and the mitochondrial cytochrome oxidase c subunit 1 (COI) gene region separated the new species from T. arcuatus and other tylenchid species. In the 28S tree, T. zeae n. sp. showed a high level of sequence divergence and was positioned outside of the main Tylenchus-Filenchus clade.

18S↗