Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling a compressible packed bed flow-through washing and deacetylation reactor for corn stover pretreatment

The deacetylation process is a key step in the lignocellulosic biomass pretreatment process that currently is done in batch reactors. A flow-through diffuser type reactor is a promising approach to make the process more efficient and economically favorable. A washing step before deacetylation can further reduce chemical usage and increase the process efficiency. However, the highly compacted biomass particles can cause significant pressure-drop for fluid flow through the bed, which in the worst case can cause self-enhancing pressure-drop leading to reactor blocking. Detailed understanding of the fundamentals of flow through a compressible packed bed is necessary to scale up the washing and deacetylation process. This work closely examines the classical Kozeny Carman equation and proposes modifications to accurately predict the pressure-drop at different compaction states. Here, a compressible packed bed model is further developed based on the interaction between solid mechanics and fluid dynamics. Experimental measurements of water flow through a packed bed of corn stover show good agreement with the developed model. Corn stover washing process scale up simulations show that smaller reactor diameter, higher friction lining material, lower process throughput, and higher process temperature is favorable in stabilizing the bed from extensive compression when the bed height is fixed.

09 BIOMASS FUELS↗

Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Effect of cellulose reducing ends and primary hydroxyl groups modifications on cellulose-cellulase interactions and cellulose hydrolysis

Cellulose reducing ends are believed to play a vital role in the cellulose recalcitrance to enzymatic conversion. However, their role in insoluble cellulose accessibility and hydrolysis is not clear. Thus, in this study, reducing ends of insoluble cellulose derived from various sources were modified by applying reducing and/or oxidizing agents. Here, the effects of cellulose reducing ends modification on cellulose reducing ends, cellulose structure, and cellulose accessibility to cellulase were evaluated along with the impact on cellulose hydrolysis with complete as well purified cellulase components. Sodium borohydride (NaBH 4 ) reduction and sodium chlorite-acetic acid (SC/AA) oxidation were able to modify more than 90% and 60% of the reducing ends, respectively, while the bicinchoninic acid (BCA) reagent applied for various cycles oxidized cellulose reducing ends to various extents. X-ray diffractograms of the treated solids showed that these treatments did not change the cellulose crystalline structure and the change in crystallinity index was insignificant. Surprisingly, it was found that the cellulose reducing ends modification, either through selective NaBH 4 reduction or BCA oxidation, had a negligible impact on cellulose accessibility as well on cellulose hydrolysis rates or final conversions with complete cellulase at loadings as low as 0.5 mg protein/g cellulose. In fact, in contrast to what is traditionally believed, modifications of cellulose reducing ends by these two methods had no apparent impact on cellulose conversion with purified cellulase components and their synergy. However, SC/AA oxidation resulted in significant drop in cellulose conversion (10%–50%) with complete as well purified cellulase components. Nonetheless, further research revealed that the cause for drop in cellulose conversion for the SC/AA oxidation case was due to primary hydroxyl groups (PHGs) oxidation and not the oxidation of reducing ends. Furthermore, it was found that the PHGs modification affects cellulose accessibility and slows the cellulase uptake as well resulting in significant drop in cellulose conversions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self‐consistent transport simulation of boron dust particle injection in the peripheral plasma in Large Helical Device

Abstract The trajectories and the ablation positions of boron dust particles dropped from an impurity powder dropper in the peripheral plasma in the Large Helical Device (LHD) were calculated using a three‐dimensional edge plasma simulation code (EMC3‐EIRENE) and a dust transport simulation code (DUSTT). The simulation shows that the trajectory of the boron dust particles is deflected at the upper divertor leg due to the effect of the hydrogen plasma flow, and the ablation positions of the dust particles in an ergodic layer change toward the outboard side of the torus for higher plasma densities. The effect of the boron ion flow in the divertor leg on the deflection is investigated by coupling the two codes self‐consistently. The simulation predicts that the boron ions in the divertor leg, which are produced by sputtering on the divertor plates, which do not affect the change in the ablation positions. It also shows that the ablation positions move toward the inboard side and approach the Last Closed Flux Surface (LCFS) in case of increased boron dust drop rates, which is caused by the lowered plasma flow in the upper divertor leg due to the lowered electron temperature by radiation cooling by the dropped dust particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of common trap types for capturing wild pigs

Abstract Wild pigs ( Sus scrofa ) are one of the most ecologically harmful invasive vertebrates globally. Due to their negative impacts, wild pig populations are managed via trapping, yet studies investigating various trap designs have been limited in duration, location, and number of trappers. Using data from professional trappers across the southeastern U.S., we evaluated the performance of 3 wild pig trap types (corral, drop, passive net), and the effect of forage season (barren, green‐up, masting) on trapping success. Specifically, we compared trap effectiveness (estimated proportion of targeted wild pigs caught per capture event), trap night effort (number of days to first catch), and the amount of bait and time used per individual take over the lifetime of each trap location across the 3 trap types and forage seasons. Across >850 capture events by 31 trappers, all 3 trap types evaluated were effective at capturing entire social groups of wild pigs. Few differences were observed among trap types, although drop traps in masting season captured a greater estimated proportion of wild pigs per capture event compared to other trap type‐season combinations. Our data also revealed that passive net traps required slightly more bait/wild pig captured than drop traps but there was no difference in the time/wild pig captured among traps. Our findings demonstrate that when operated by wildlife professionals, multiple designs of wild pig traps can be effective at removing targeted groups of wild pigs. Further, our results offer insights regarding the performance of wild pig trap types across seasons that can be used to inform wild pig trapping programs.

Taylor, Charles R. [Warnell School of Forestry and↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Industrial scale mesofluidic particle separation

Here we explore the potential of a mesofluidic separator that fits within industrial piping and is designed to remove large aspherical particles out of an abrasive slurry at fast flow rates. Mesofluidic separators have recently demonstrated separation of spherical particles at flow rates of ~1 gallon/min (gpm) (6.3.10 -5 m 3 /s). Yet, the performance of these separators at flow rates achievable within industrial piping have not been explored. Here we evaluate the permeate flowrate fraction, large particle mass fraction, and pressure drop from approximately 35-100 gpm (2.2.10-3-6.3.10-3 m 3 /s) in a three inch tube using an abrasive and modestly non-spherical slurry. Faster flow rates may be achieved with larger pumps and larger diameters. We find the permeate fraction and pressure drop both increase with flow rate, though the pressure drop remains modest. Only two feet of inserts removed 97.6±2.1% of large particles for conditions tested. Separation was demonstrated in both vertical and horizontal orientations with the horizontal orientation benefiting marginally from gravitational settling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Degradation in interfacial shear strength of carbon fiber/ vinyl ester composites due to long-term exposure to seawater using push-out tests

Here, in this study, single fiber (~7-μm diameter) push-out tests are conducted to evaluate hygrothermal effects on the interfacial shear strength (IFSS) of carbon fiber/vinyl ester (CF/VE) composites. Hygrothermal conditioning is achieved by saturating samples in simulated seawater at 40 °C for two years. An investigation has been conducted on the preparation, validity, and interpretation of the push-out test results. First, the authors present a polishing methodology that results in thin films of CF/VE composites in the thickness range of 15–120 μm and produces an average 41.2% drop in IFSS due to long-term hygrothermal exposure. Using scanning electron microscopy (SEM), we show that during the push-out tests, the failure initiates locally at the zone of minimum bond strength at the bottom (away from the indenter), then propagates along the length of the interface. The influence of radial tensile stresses originating due to bending is found to be negligible. Using the SEM imaging of the pushed-out fibers, we validate the failure of the interface to be the primary source of failure. The associated results are found to depend on the thickness of the interface. We then reevaluate the results using the Weibull distribution, knowing that the failure mechanism is analogous to the weakest link theory. The results show a 25.5% drop in the IFSS of the CFVE composite, measured at an infinitesimal scale due to long-term to hygrothermal conditioning at 40 °C. A significant drop in IFSS was observed after reheating above glass transition temperature (T g ) and cooling.

36 MATERIALS SCIENCE↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗