Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Synthetic U.S. Electric Power Distribution System Data Sets

There is a strong need for synthetic yet realistic distribution system test data sets that are as diverse, large, and complex to solve as real systems. Such data sets can facilitate the development of advanced algorithms and the assessment of emerging distributed energy resources while avoiding the need to acquire proprietary critical infrastructure or private data. Such synthetic data sets, however, are useful only if they are realistic enough to look and behave similarly to actual systems. This paper presents a comprehensive framework for validating synthetic distribution data sets using a three-pronged statistical, operational, and expert validation approach. Furthermore, it also presents a set of statistical and operational metric targets for achieving realistic data sets based on detailed characterization of more than 10,000 real U.S. utility feeders. The paper demonstrates the use of the proposed validation approach to validate three large-scale synthetic data sets developed by the authors representing Santa Fe, New Mexico; Greensboro, North Carolina; and the San Francisco Bay Area, California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Baselines for Electric Distribution Systems and DER

The National Association of Regulatory Utility Commissioners (NARUC) has partnered with the Department of Energy (DOE) to develop a set of cybersecurity baselines for electric distribution systems and the distributed energy resources (DERs) that connect to them. Cybersecurity is an integral underpinning of power system resilience, and this initiative builds on work that states have undertaken over the last decade to mitigate cybersecurity risk across their critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Reinforcement Learning for Volt-VAR Control in Power Distribution Systems

Volt-VAR control (VVC) is crucial in active distribution networks for optimizing voltage profiles and minimizing network losses. While traditional deep reinforcement learning (DRL) algorithms exhibit promise for VVC, they often require extensive computational resources to handle such a high-dimensional problem. As a potential solution, quantum reinforcement learning (QRL) algorithms integrate the computational capabilities of quantum computing into the DRL framework. However, existing QRL algorithms struggle with complex VVC problems due to the limitations of current quantum hardware. To bridge this gap, this paper proposes an innovative QRL algorithm featuring an end-to-end architecture that integrates a classical autoencoder, variational quantum circuits (VQCs), and classical post-processing layers. This design efficiently compresses high-dimensional grid states, enabling VQCs to leverage quantum advantages while producing multiple control device outputs tailored for VVC tasks. Numerical studies on three representative distribution systems verify the effectiveness and scalability of the proposed QRL algorithm, and demonstrate its enhanced performance over classical approaches with only approximately 1% of the parameters. Additionally, the robustness of our developed algorithm is validated through noisy quantum environments.

97 MATHEMATICS AND COMPUTING↗

Heavy-Duty Truck Electrification and the Impacts of Depot Charging on Electricity Distribution Systems

Major technological advancements and recent policy support are improving the outlook for heavy-duty truck electrification in the United States. In particular, short-haul operations (=200 miles (=322 km)) are prevalent and early candidates for plug-in electric vehicles (EVs) given their short, predictable routes and return-to-base applications, which allows vehicles to recharge when off shift at their depots. Although previous studies investigated the impacts of added electrical loads on distribution systems, which included light-duty EVs, the implications for heavy-duty EV charging are underexplored. Here we summarize the causes, costs and lead times of distribution system upgrades anticipated for depot charging. We also developed synthetic depot charging load profiles for heavy-duty trucks from real-world operating schedules, and found that charging requirements are met at common light-duty EV charging rates (=100 kW per vehicle). Finally, we applied depot charging load profiles to 36 distribution real-world substations, which showed that most can accommodate high levels of heavy-duty EV charging without upgrades.

47 OTHER INSTRUMENTATION↗

Multi-Task Reinforcement Learning for Distribution System Voltage Control With Topology Changes

This letter proposes a multi-task deep reinforcement learning (DRL) approach for distribution system voltage regulation considering topology changes via PV smart inverter control. The key idea is to encode the topology as an additional state for the DRL and leverage the multi-task learning scheme for joint learning of all task control policies. Unlike other DRL-based methods, our approach is robust to different topologies. Comparison results on the modified IEEE 123-node system demonstrate the enhanced robustness of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High Voltage Distribution System for the Mu2e Electron Tracker

This paper describes the design and development of a High Voltage distribution system (Smart Switch - SS) which distributes one input high voltage (HV) into six High Voltage channels (HVDS) of a straw detector plane. The SS independently sets, controls, and monitors the HV to each individual channel of a straw-detector plane in the Mu2E Electron Tracking Detector. Each straw plane is composed of three 120 deg crescent-shaped panels, and each panel is composed of 96 straw-tube detectors. Each output channel of the SS has independent, ON-OFF, current and HV monitoring, as well as filtration, isolation, and a crowbar to provide overcurrent protection for in that channel. The inter-communication system is based on TCP/IP protocol using a Raspberry Pi. The HVDS meets all required specifications including long term stability, accurate monitoring of the HV and current, and overcurrent trip. The performance of the HVDS was found to be comparable to, if not better than, commercial HV power supplies.

42 ENGINEERING↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs: Preprint

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Resilient Distribution System Restoration with Equitable Load Shedding

A methodology is proposed for the improvement of electric distribution system resilience to high-impact, low-probability catastrophic events. An approach for dynamic network reconfiguration and coordination of distributed energy resources is introduced to assist in restoration efforts. The problem is formulated as a mixed-integer linear program that minimizes generation costs, the cost of lost load, and costs associated with equitable load shedding, while respecting operational limits of generation, loads, and the network. Constraints are imposed on binary switching variables to ensure equitable load shedding in emergency situations. Numerical validation of the proposed approach is conducted on an example distribution feeder, and case studies are performed to analyze the impact of various parameters in the optimization problem formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

adaptive robust optimization↗

The Role of the U.S. Electric Distribution System in Serving Data Center and Other Large Loads

The rapid expansion of data centers in the United States is reshaping how the electric distribution system must plan for and accommodate large load interconnections. This report evaluates the role of the distribution grid in serving these loads, from small edge facilities to hyperscale campuses. Using national datasets, utility filings, and industry studies, we assess demand growth, reliability requirements, interconnection thresholds, and infrastructure needs at substations and feeders. The analysis highlights the mismatch between fast data center development timelines and slower utility planning and construction cycles, as well as strategies such as phased energization, on-site generation, hosting capacity maps, and structured interconnection frameworks. While focused on data centers, the insights also apply to other high-density loads such as advanced manufacturing, hydrogen production, and electrified transportation. The report concludes with approaches to align planning processes, transparency tools, and regulatory frameworks so utilities can manage new large loads in ways that support a reliable and resilient grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Risk-Driven Probabilistic Approach to Quantify Resilience in Power Distribution Systems

It is of growing concern to ensure resilience in power distribution systems to extreme weather events. However, there are no clear methodologies or metrics available for resilience assessment that allows system planners to assess the impact of appropriate planning measures and new operational procedures for resilience enhancement. In this paper, we propose a resilience metric using parameters that define system attributes and performance. To represent extreme events (tail probability), the conditional value-at-risk of each of the parameters are combined using Choquet Integral to evaluate the overall resilience. The effectiveness of the proposed resilience metric is studied within the simulation-based framework under extreme weather scenarios with the help of a modified IEEE 123-bus system. With the proposed framework, system operators will have additional flexibility to prioritize one investment over the others to enhance the resilience of the grid.

Poudyal, Abodh↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.