Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed resources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Guidance for Distributed Energy Resource Management Systems (DERMS)

As part of the Securing Solar for the Grid (S2G): Cybersecurity for Solar Systems workshop at RE + in Las Vegas, Nevada, NREL researchers discuss an ongoing effort to develop cybersecurity guidance for vendors and operators of distributed energy resource management systems (DERMS). This guide will prioritize cybersecurity best practices that can be testing and developed for a potential future standard. This presentation will highlight NREL's ongoing work in this area and future areas of research.

cyber↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

SOLAr Critical Infrastructure Energization (SOLACE): Leveraging Distributed Energy Resources to Provide Local Power

This document is a technical report based on a large-scale DOE-funded project conducted between 2019 and 2022. The project, called SOLAr Critical infrastructure Energization (SOLACE), is aimed at leveraging distributed energy resources (DERs) to provide local power to communities, feeders, or other regions. The project included a particular focus on high-value critical loads such as municipal water supply, telecommunication hubs, and disaster shelters. The key developments of the project were: (1) A comprehensive pre-event power system analysis methodology that identifies and characterizes the viable local power options. (2) A DMS-based example control system for activating and operating the local power solution during a time of crisis. (3) Grid-forming inverter technology to enable isolated local power operation and black-starting. (4) Cyber-security considerations for isolated systems when wider-area communication may be offline. This report describes the overall process that identifies and assesses the viable DER-based local power solutions for a given facility, region, or community. The report documents the process, including the key analysis steps, tools required, data requirements, and recommended pass/fail criteria for each step. It also provides a sample implementation of this process through a test case. Finally, it provides details of how a viable pre-event plan can be selected and activated at go-time when an event has occurred.

14 SOLAR ENERGY↗

Locational Value of Distributed Energy Resources

This report focuses on potential DER benefits for distribution systems, primarily in their role as non-wires alternatives to defer, mitigate, or eliminate the need for some traditional system investments at locations where distribution capacity is insufficient to meet expected future needs. It describes approaches and tools to estimate the locational value of DERs. The report includes 24 case studies to illustrate how states and utilities are considering the locational value of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plan It Together: Optimizing Across Generation, Transmission, Distribution, and Distributed Energy Resources

Integrated planning holds the promise of unlocking lower total system cost solutions by connecting previously siloed planning processes. This article summarizes the state of bulk and local grid planning today and details multiple new analytical approaches that can enable more holistic planning methods to develop comprehensive solutions to generation, transmission, distribution, and distributed energy resource needs. These include both iterative approaches as well as cooptimization techniques. In addition to the benefits of these methods, the technical and institutional challenges and associated solutions are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

USAID Colombia Young Leaders Workforce Training Program Action Plans: Regulatory Road Map for Distributed Energy Resource (DER) Interconnection and Interoperability

As part of the U.S. Agency for International Development (USAID)-National Renewable Energy Laboratory (NREL) Young Leaders Workforce Training Program in Colombia, participants from Colombia's Energy and Gas Regulatory Commission (CREG) leveraged their training and professional experience to develop a regulatory roadmap for the interconnection and interoperability of increasing integration of distributed energy resources (DERs). CREG was one of four teams selected by the training program development team to receive continued technical assistance and strategic advisory support from the USAID-NREL Partnership for action plan development and implementation. This case study provides an overview of the key activities and outcomes of the technical assistance provided by NREL on the CREG Action Plan, and key next steps for implementation of Colombia's DER Integration Regulatory Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Automation for Distributed Energy Resources Risk Manager Using OSCAL

The risk management framework (RMF) provides a well-organized and thorough approach to diagnose information technology (IT) system threats, to gather required materials to comply with industry standards, and to document a plan for achieving authority to operate (ATO). ATO is given by the operating authority with the awareness of vulnerabilities that arise when operating the IT system. The primary goal of the National Renewable Energy Laboratory’s (NREL’s) distributed energy resource (DER) RM application is to provide a user-friendly interface and in-depth guidance for generating the authorization package for the authorizing official to review. In other words, the application satisfies steps 1 through 7 of the RMF process with a focus on DERs.

cybersecurity↗

Service-Based, Segmented, 5G Network-Based Architecture for Securing Distributed Energy Resources: Preprint

As the number of connected devices in the energy grid increase exponentially, so too are the cybersecurity risks. With the development of modern communications standards such as 5G and beyond the extent to which devices will continue to connect will continue to increase exponentially along with the inherent risks. However, 5G also includes features to help address cybersecurity concerns and therefore helping to mitigate many of these risks. This paper proposes a new service-based network architecture implementing network-slicing capabilities for connected systems and devices to improve performance, availability, security, and reliability of the grid devices and services. This paper considers the quality of service requirements and criticality of services needed for securely monitoring, operating, and securing Distributed Energy Resource (DER) devices. From developed use cases, network slicing is implemented based on these requirements and resource allocations. This work then highlights examples of how slicing can help prevent standard existing attack methods such as a denial-of-service or similar attack which limits resource availability and network bandwidth to the service and thus limiting its ability to affect other services by misbehaving. The designed network architecture use case will be further tested on a local virtualized testbed to verify secure operation and availability of services. Using hardware-in-the-loop devices and systems on this local testbed, this fully segmented, secure network may be realized and evaluated. Finally, this paper presents the results of this testing.

5G↗

Distributed Energy Resource Management Systems: Preserving Customer Privacy through K-Anonymity

The smart grid represents the next generation of electricity distribution systems that utilizes recent technological innovations. It uses digital communication between its components and entities to attain more automation, self-sufficiency, and reliability. One of the many concerns in smart grid digital communication discussions is the possibility of violating customers’ privacy. Violating customers’ privacy imposes a significant barrier as smart grid desirable attributes are tightly tied to customers’ participation. Employing privacy models can address concerns regarding information privacy in smart grid digital communication. In this work, we provide an approach to utilizing K-anonymity to ensure data within the system excludes Personally Identifiable Information. Results suggest that a dynamically generated generalization hierarchy minimizes information loss incurred by the anonymization process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic risk analysis for the capture of a distributed energy resource using modular chemical process intensification

Recent advances in the chemical process industry have allowed for the intensification of reactors and unit operations, by enhancing heat and mass transfer or combining multiple unit operations. Process intensification can enable chemical plants to be constructed in a more compact, modular fashion, offering improvements over conventional on-site approaches to capital construction, operations and maintenance. This modular chemical process intensification (MCPI) offers several benefits over conventional stick-built (CSB) plant construction in terms of reduced footprint, reduced energy consumption, lower cost, less waste and improved safety and quality control. However, acceptance of MCPI over CSB construction practices within the chemical industry can be impeded by the uncertain risks associated with investing in new technology. Furthermore, the work here documents a case study during the development of a modular chemical plant for capturing distributed energy resources within chemical production. This MCPI approach to plant construction is contrasted with a CSB approach for producing the same chemical product. Data collection tools were developed, based on a literature review, and data was collected from the technology developer to understand the process technology. Sensitivity analysis was then conducted to analyze the business rationale for the application of MCPI over CSB across several market scenarios. It was found that MCPI would be better suited for capacities up to 150 000 metric tons per year, but that improvement in payback period was needed. Additionally, for MCPI approach to achieve acceptable payback periods, efforts are needed to reduce the cost of capital equipment and compress the schedule for ramping up modular production.

42 ENGINEERING↗

Development of an Interactive Valuation Model for Distributed Energy Resource Value: Cooperative Research and Development (Final Report)

The Oklahoma Office of the Secretary of Energy and Environment (OSEE) seeks to address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma. The Scope of Work (SOW) associated with CRD-18-762 covers two tasks: (1) Interactive Valuation Model Requirements Document and (2) Consumer Protection Assessment. Follow-on work was completed under a separate CRADA (CRD-19-00788).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗