Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostic procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Spray Combustion Modeling with VOF and Finite-Rate Chemistry

A spray atomization and combustion model is developed based on the volume-of-fluid (VOF) transport equation with finite-rate chemistry model. The gas-liquid interface mass, momentum and energy conservation laws are modeled by continuum surface force mechanisms. A new solution method is developed such that the present VOF model can be applied for all-speed range flows. The objectives of the present study are: (1) to develop and verify the fractional volume-of-fluid (VOF) cell partitioning approach into a predictor-corrector algorithm to deal with multiphase (gas-liquid) free surface flow problems; (2) to implement the developed unified algorithm in a general purpose computational fluid dynamics (CFD) code, Finite Difference Navier-Stokes (FDNS), with droplet dynamics and finite-rate chemistry models; and (3) to demonstrate the effectiveness of the present approach by simulating benchmark problems of jet breakup/spray atomization and combustion. Modeling multiphase fluid flows poses a significant challenge because a required boundary must be applied to a transient, irregular surface that is discontinuous, and the flow regimes considered can range from incompressible to highspeed compressible flows. The flow-process modeling is further complicated by surface tension, interfacial heat and mass transfer, spray formation and turbulence, and their interactions. The major contribution of the present method is to combine the novel feature of the Volume of Fluid (VOF) method and the Eulerian/Lagrangian method into a unified algorithm for efficient noniterative, time-accurate calculations of multiphase free surface flows valid at all speeds. The proposed method reformulated the VOF equation to strongly couple two distinct phases (liquid and gas), and tracks droplets on a Lagrangian frame when spray model is required, using a unified predictor-corrector technique to account for the non-linear linkages through the convective contributions of VOF. The discontinuities within the sharp interface will be modeled as a volume force to avoid stiffness. Formations of droplets, tracking of droplet dynamics and modeling of the droplet breakup/evaporation, are handled through the same unified predictor-corrector procedure. Thus the new algorithm is non-iterative and is flexible for general geometries with arbitrarily complex topology in free surfaces. The FDNS finite-difference Navier-Stokes code is employed as the baseline of the current development. Benchmark test cases of shear coaxial LOX/H2 liquid jet with atomization/combustion and impinging jet test cases are investigated in the present work. Preliminary data comparisons show good qualitative agreement between data and the present analysis. It is indicative from these results that the present method has great potential to become a general engineering design analysis and diagnostics tool for problems involving spray combustion.

Chen, Yen-Sen↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

Over the past year the Nuclear Thermal Rocket Element Environmental Simulator (NTREES) has been undergoing a significant upgrade beyond its initial configuration. The NTREES facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The first phase of the upgrade activities which was completed in 2012 in part consisted of an extensive modification to the hydrogen system to permit computer controlled operations outside the building through the use of pneumatically operated variable position valves. This setup also allows the hydrogen flow rate to be increased to over 200 g/sec and reduced the operation complexity of the system. The second stage of modifications to NTREES which has just been completed expands the capabilities of the facility significantly. In particular, the previous 50 kW induction power supply has been replaced with a 1.2 MW unit which should allow more prototypical fuel element temperatures to be reached. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during. This new setup required that the NTREES vessel be raised onto a platform along with most of its associated gas and vent lines. In this arrangement, the induction heater and water systems are now located underneath the platform. In this new configuration, the 1.2 MW NTREES induction heater will be capable of testing fuel elements and fuel materials in flowing hydrogen at pressures up to 1000 psi at temperatures up to and beyond 3000 K and at near-prototypic reactor channel power densities. NTREES is also capable of testing potential fuel elements with a variety of propellants, including hydrogen with additives to inhibit corrosion of certain potential NTR fuel forms. Additional diagnostic upgrades included in the present NTREES set up include the addition of a gamma ray spectrometer located near the vent filter to detect uranium fuel particles exiting the fuel element in the propellant exhaust stream to provide additional information any material loss occurring during testing. Other aspects of the upgrade included reworking NTREES to reduce the operational complexity of the system despite the increased complexity of the induction heating system. To this end, many of the controls were consolidated on fewer panels. As part of this upgrade activity, the Safety Assessment (SA) and the Standard Operating Procedures (SOPs) for NTREES were extensively rewritten. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can be accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements.

Emrich, William J., Jr.↗

Integrated System Health Management: Foundational Concepts, Approach, and Implementation.

Implementation of integrated system health management (ISHM) capability is fundamentally linked to the management of data, information, and knowledge (DIaK) with the purposeful objective of determining the health of a system. It is akin to having a team of experts who are all individually and collectively observing and analyzing a complex system, and communicating effectively with each other in order to arrive to an accurate and reliable assessment of its health. We present concepts, procedures, and a specific approach as a foundation for implementing a credible ISHM capability. The capability stresses integration of DIaK from all elements of a system. The intent is also to make possible implementation of on-board ISHM capability, in contrast to a remote capability. The information presented is the result of many years of research, development, and maturation of technologies, and of prototype implementations in operational systems (rocket engine test facilities). The paper will address the following topics: 1. ISHM Model of a system 2. Detection of anomaly indicators. 3. Determination and confirmation of anomalies. 4. Diagnostic of causes and determination of effects. 5. Consistency checking cycle. 6. Management of health information 7. User Interfaces 8. Example implementation ISHM has been defined from many perspectives. We define it as a capability that might be achieved by various approaches. We describe a specific approach that has been matured throughout many years of development, and pilot implementations. ISHM is a capability that is achieved by integrating data, information, and knowledge (DIaK) that might be distributed throughout the system elements (which inherently implies capability to manage DIaK associated with distributed sub-systems). DIaK must be available to any element of a system at the right time and in accordance with a meaningful context. ISHM Functional Capability Level (FCL) is measured by how well a system performs the following functions: (1) detect anomalies, (2) diagnose causes, (3) predict future anomalies/failures, and (4) provide the user with an integrated awareness about the condition of every element in the system and guide user decisions.

Figueroa, Fernando↗

Rapid Detection of the Varicella Zoster Virus

1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.

Lewis, Michelle P.↗

Wind Tunnel Investigation of the Supersonic Stage Separation Aerodynamics of a Generic 0.0175-Scale Bimese Two-Stage-to-Orbit Reusable Launch Vehicle Configuration

A wind tunnel investigation was conducted of the supersonic stage separation aerodynamics of a generic two-stage-to-orbit bimese wingbody configuration in the NASA Langley Research Center Unitary Plan Wind Tunnel. Proximity and isolated model testing was conducted at Mach numbers of 2.3, 3.0, and 4.5 and a unit Reynolds number of 2.0 million per foot using 0.0175-scale models of the Langley Glide-Back Booster concept designated as the orbiter and booster in belly-to-belly and back-to-belly configurations. Longitudinal forces and moments were obtained on both models and surface static pressure measurements were obtained on the orbiter model at 328 relative proximity locations and at relative angles of attack of 0 degrees and 5 degrees. The test results supported a larger effort to develop and validate experimental and computational tools applicable to the design and simulation of stage separation and abort procedures for reusable launch vehicles composed of multiple bodies, including winged bodies. An initial proof-of-concept experiment featuring low-cost uninstrumented models was conducted to verify an emerging automated model control system and new support system hardware, and to identify potential model and support system blockage and unsteady aerodynamics/model dynamics prior to committing to higher-fidelity instrumented models. This investigation led to upgrades in the facility stage separation hardware, calibration and testing techniques and capabilities, and data analysis and documentation methodologies that have been extended to the more recent NASA Constellation and Space Launch System crew and cargo launch vehicle programs. A virtual diagnostics interface methodology was used to facilitate the design of the stage separation support hardware, to position the models in the test section, and to define the experimental test space. Advances in the facility automated model positioning system established a foundation for the development of a continuous-sweep data acquisition technique that is responsible for significant productivity improvements to the current NASA Space Launch System test program. The automated model positioning capability was leveraged to conduct a companion statistically-designed stage separation experiment requiring randomization of the relative proximity positions of the orbiter and booster models. The respective zones of influence and interference effects of the orbiter and booster were identified from three-dimensional scatter plots, contour and influence maps, and two-dimensional plotting methods. The highly-nonlinear, shock-dominated aerodynamic characteristics of the orbiter and booster in the Unitary Plan Wind Tunnel exhibited good agreement with independent test data obtained in a NASA Marshall Space Flight Center wind tunnel and with computational fluid dynamics predictions using a compressible, three-dimensional flow solver and an inviscid, unstructured Cartesian method.

Erickson, Gary E.↗

Noninvasive Test Detects Cardiovascular Disease

At NASA's Jet Propulsion Laboratory (JPL), NASA-developed Video Imaging Communication and Retrieval (VICAR) software laid the groundwork for analyzing images of all kinds. A project seeking to use imaging technology for health care diagnosis began when the imaging team considered using the VICAR software to analyze X-ray images of soft tissue. With marginal success using X-rays, the team applied the same methodology to ultrasound imagery, which was already digitally formatted. The new approach proved successful for assessing amounts of plaque build-up and arterial wall thickness, direct predictors of heart disease, and the result was a noninvasive diagnostic system with the ability to accurately predict heart health. Medical Technologies International Inc. (MTI) further developed and then submitted the technology to a vigorous review process at the FDA, which cleared the software for public use. The software, patented under the name Prowin, is being used in MTI's patented ArterioVision, a carotid intima-media thickness (CIMT) test that uses ultrasound image-capturing and analysis software to noninvasively identify the risk for the major cause of heart attack and strokes: atherosclerosis. ArterioVision provides a direct measurement of atherosclerosis by safely and painlessly measuring the thickness of the first two layers of the carotid artery wall using an ultrasound procedure and advanced image-analysis software. The technology is now in use in all 50 states and in many countries throughout the world.

Source record↗

Civil helicopter propulsion system reliability and engine monitoring technology assessments

A study to reduce operating costs of helicopters, particularly directed at the maintenance of the propulsion subsystem, is presented. The tasks of the study consisted of problem definition refinement, technology solutions, diagnostic system concepts, and emergency power augmentation. Quantifiable benefits (reduced fuel consumption, on-condition engine maintenance, extended drive system overhaul periods, and longer oil change intervals) would increase the initial cost by $43,000, but the benefit of $24.46 per hour would result in breakeven at 1758 hours. Other benefits not capable of being quantified but perhaps more important include improved aircraft avilability due to reduced maintenance time, potential for increased operating limits due to continuous automatic monitoring of gages, and less time and fuel required to make engine power checks. The most important improvement is the on-condition maintenance program, which will require the development of algorithms, equipment, and procedures compatible with all operating environments.

Murphy, J. A.↗

In-situ Raman Instrumentation and Measurements in Supercritical Water Oxidation Systems

Due to the advent of recent advances in reactor designs and operational procedures, renewed attention has been given to a host of supercritical water oxidation (SCWO) technology applications. This includes resource recovery, water reclamation, and solid waste destruction. SCWO is often recognized as a “green technology” because of its ability to extract useful energy while producing benign products from environmentally challenging waste streams (e.g., wet organic wastes, pharmaceutical wastes, military wastes). The present work was motivated by NASA’s interests in solid waste management and water recovery for long-duration space missions. To that end, the main focus of this paper is to present work on characterizing the behavior of supercritical water oxidation systems utilizing state of the art laser Raman spectroscopy. The main benefit of Raman diagnostics is its ability to identify chemical composition and to measure concentrations of the compounds involved in the reaction. Two separate Raman systems for SCWO measurements that have been developed for this study will be described. The first system is a 2-D traversing system useful for making in-situ measurements in conditions where spatial gradients of species and temperature are important and has been successfully utilized in making species (ethanol, oxygen, water, nitrogen and carbon dioxide) concentrations and temperature measurements in ethanol hydrothermal jet flames. The second system is a packaged modular Raman probe unit for portable deployment to different reactors and is more suitable for relatively homogeneous systems such as a batch reactor. The design, development, and examples of obtained results from both systems will be presented for various reactant streams. Reaction rate and fuel conversion estimates from chemistry models will also be presented.

supercritical water oxidation↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

Review of performance, medical, and operational data on pilot aging issues

An extensive review of the literature and studies relating to performance, medical, operational, and legal data regarding pilot aging issues was performed in order to determine what evidence there is, if any, to support mandatory pilot retirement. Popular misconceptions about aging, including the failure to distinguish between the normal aging process and disease processes that occur more frequently in older individuals, continue to contribute to much of the misunderstanding and controversy that surround this issue. Results: Review of medical data related to the pilot aging issue indicate that recent improvement in medical diagnostics and treatment technology have made it possible to identify to a high degree individuals who are at risk for developing sudden incapacitating illness and for treating those with disqualifying medical conditions. Performance studies revealed that after controlling for the presence of disease states, older pilots are able to perform as well as younger pilots on many performance tasks. Review of accident data showed that older, healthy pilots do not have higher accident rates than younger pilots, and indeeed, evidence suggests that older pilots have an advantage in the cockpit due to higher experience levels. The Man-Machine-Mission-Environment interface of factors can be managed through structured, supervised, and enhanced operations, maintenance, flight reviews, and safety procedures in order to ensure safe and productive operations by reducing the margin of error and by increasing the margin of safety. Conclusions: There is no evidence indicating any specific age as an arbitrary cut-off point for pilots to perform their fight duties. A combination of regular medical screening, performance evaluation, enhanced operational maintenance, and safety procedures can most effectively ensure a safe pilot population than can a mandatory retirement policy based on arbitrary age restrictions.

Stoklosa, J. H.↗

ATLAS LTCS Vertically Challenged System Lessons Learned

Re-planning of LTCS TVAC testing and supporting RTA (Receiver Telescope Assembly) Test Plan and Procedure document preparation. The Laser Thermal Control System (LTCS) is designed to maintain the lasers onboard Advanced Topographic Laser Altimeter System (ATLAS) at their operational temperatures. In order to verify the functionality of the LTCS, a thermal balance test of the thermal hardware was performed. During the first cold start of the LTCS, the Loop Heat Pipe (LHP) was unable to control the laser mass simulators temperature. The control heaters were fully on and the loop temperature remained well below the desired setpoint. Thermal analysis of the loop did not show these results. This unpredicted behavior of the LTCS was brought up to a panel of LHP experts. Based on the testing and a review of all the data, there were multiple diagnostic performed in order to narrow down the cause. The prevailing theory is that gravity is causing oscillating flow within the loop, which artificially increased the control power needs. This resulted in a replan of the LTCS test flow and the addition of a GSE heater to allow vertical operation.

Loop Heat Pipe↗

Coronal Magnetography of Solar Active Regions Using Coordinated SOHO/CDS and VLA Observations

The purpose of this project is to apply the coronal magnetographic technique to SOHO (Solar Heliospheric Observatory) /CDS (Coronal Diagnostic Spectrometer) EUV (Extreme Ultraviolet Radiation) and coordinated VLA microwave observations of solar active regions to derive the strength and structure of the coronal magnetic field. A CDS observing plan was developed for obtaining spectra needed to derive active region differential emission measures (DEMs) required for coronal magnetography. VLA observations were proposed and obtained. SOHO JOP 100 was developed, tested, approved, and implemented to obtain coordinated CDS (Coronal Diagnostic Spectrometer)/EIT (Ultraviolet Imaging Telescope)/ VLA (Very Large Array)/ TRACE (Transition Region and Coronal Explorer)/ SXT (Solar X Ray Telescope) observations of active regions on April 12, May 9, May 13, and May 23. Analysis of all four data sets began, with heaviest concentration on COS data. It is found that 200-pixel (14 A in NIS1) wavelength windows are appropriate for extracting broadened Gaussian line profile fit parameters for lines including Fe XIV at 334.2, Fe XVI at 335.4, Fe XVI at 360.8, and Mg IX at 368.1 over the 4 arcmin by 4 arcmin CDS field of view. Extensive efforts were focused on learning and applying were focused on learning and applying CDS software, and including it in new IDL procedures to carry out calculations relating to coronal magnetography. An important step is to extract Gaussian profile fits to all the lines needed to derive the DEM in each spatial pixel of any given active region. The standard CDS absolute intensity calibration software was applied to derived intensity images, revealing that ratios between density-insensitive lines like Fe XVI 360.8/335.4 yield good agreement with theory. However, the resulting absolute intensities of those lines are very high, indicating that revisions to the CDS absolute intensity calibrations remain to be included in the CDS software, an essential step to deriving reliable coronal magnetograms. With lessons learned and high quality data obtained during the past year, coronal magnetography will be successfully pursued under my new SOHO GI program.

Brosius, Jeffrey W.↗

Structural Health Management of Damaged Aircraft Structures Using the Digital Twin Concept

The development of multidisciplinary integrated Structural Health Management (SHM) tools will enable accurate detection, and prognosis of damaged aircraft under normal and adverse conditions during flight. As part of the digital twin concept, methodologies are developed by using integrated multiphysics models, sensor information and input data from an in-service vehicle to mirror and predict the life of its corresponding physical twin. SHM tools are necessary for both damage diagnostics and prognostics for continued safe operation of damaged aircraft structures. The adverse conditions include loss of control caused by environmental factors, actuator and sensor faults or failures, and structural damage conditions. A major concern in these structures is the growth of undetected damage/cracks due to fatigue and low velocity foreign object impact that can reach a critical size during flight, resulting in loss of control of the aircraft. To avoid unstable, catastrophic propagation of damage during a flight, load levels must be maintained that are below a reduced load-carrying capacity for continued safe operation of an aircraft. Hence, a capability is needed for accurate real-time predictions of damage size and safe load carrying capacity for structures with complex damage configurations. In the present work, a procedure is developed that uses guided wave responses to interrogate damage. As the guided wave interacts with damage, the signal attenuates in some directions and reflects in others. This results in a difference in signal magnitude as well as phase shifts between signal responses for damaged and undamaged structures. Accurate estimation of damage size, location, and orientation is made by evaluating the cumulative signal responses at various pre-selected sensor locations using a genetic algorithm (GA) based optimization procedure. The damage size, location, and orientation is obtained by minimizing the difference between the reference responses and the responses obtained by wave propagation finite element analysis of different representative cracks, geometries, and sizes.

Seshadri, Banavara R.↗

Periodontal Probe Improves Exams, Alleviates Pain

Dentists, comedian Bill Cosby memorably mused, tell you not to pick your teeth with any sharp metal object. Then you sit in their chair, and the first thing they grab is an iron hook!" Conventional periodontal probing is indeed invasive, uncomfortable for the patient, and the results can vary greatly between dentists and even for repeated measurements by the same dentist. It is a necessary procedure, though, as periodontal disease is the most common dental disease, involving the loss of teeth by the gradual destruction of ligaments that hold teeth in their sockets in the jawbone. The disease usually results from an increased concentration of bacteria in the pocket, or sulcus, between the gums and teeth. These bacteria produce acids and other byproducts, which enlarge the sulcus by eroding the gums and the periodontal ligaments. The sulcus normally has a depth of 1 to 2 millimeters, but in patients with early stages of periodontal disease, it has a depth of 3 to 5 millimeters. By measuring the depth of the sulcus, periodontists can have a good assessment of the disease s progress. Presently, there are no reliable clinical indicators of periodontal disease activity, and the best available diagnostic aid, periodontal probing, can only measure what has already been lost. A method for detecting small increments of periodontal ligament breakdown would permit earlier diagnosis and intervention with less costly and time-consuming therapy, while overcoming the problems associated with conventional probing. The painful, conventional method for probing may be destined for the archives of dental history, thanks to the development of ultrasound probing technologies. The roots of ultrasound probes are in an ultrasound-based time-of-flight technique routinely used to measure material thickness and length in the Nondestructive Evaluation Sciences Laboratory at Langley Research Center. The primary applications of that technology have been for corrosion detection and bolt tension measurements (Spinoff 2005). This ultrasound measurement system was adapted to the Periodontal Structures Mapping System, invented at Langley by John A. Companion, under the supervision of Dr. Joseph S. Heyman. Support of the research and development that led to this invention was provided by NASA s Technology Applications Engineering Program and by the Naval Institute for Dental and Biomedical Research, in Great Lakes, Illinois.

Source record↗

Inductive Approaches to Improving Diagnosis and Design for Diagnosability

The first research area under this grant addresses the problem of classifying time series according to their morphological features in the time domain. A supervised learning system called CALCHAS, which induces a classification procedure for signatures from preclassified examples, was developed. For each of several signature classes, the system infers a model that captures the class's morphological features using Bayesian model induction and the minimum message length approach to assign priors. After induction, a time series (signature) is classified in one of the classes when there is enough evidence to support that decision. Time series with sufficiently novel features, belonging to classes not present in the training set, are recognized as such. A second area of research assumes two sources of information about a system: a model or domain theory that encodes aspects of the system under study and data from actual system operations over time. A model, when it exists, represents strong prior expectations about how a system will perform. Our work with a diagnostic model of the RCS (Reaction Control System) of the Space Shuttle motivated the development of SIG, a system which combines information from a model (or domain theory) and data. As it tracks RCS behavior, the model computes quantitative and qualitative values. Induction is then performed over the data represented by both the 'raw' features and the model-computed high-level features. Finally, work on clustering for operating mode discovery motivated some important extensions to the clustering strategy we had used. One modification appends an iterative optimization technique onto the clustering system; this optimization strategy appears to be novel in the clustering literature. A second modification improves the noise tolerance of the clustering system. In particular, we adapt resampling-based pruning strategies used by supervised learning systems to the task of simplifying hierarchical clusterings, thus making post-clustering analysis easier.

Fisher, Douglas H.↗

Diaplectic Glass Content in Experimentally Shock-loaded Quartz Determined by X-Ray Powder Diffraction

Quartz is the most common mineral of terrestrial crustal rocks and thus a widespread indicator for impact cratering and associated shock metamorphism. Planar deformation features (PDFs) are among the most prominent and diagnostic shock features in quartz and they represent thin lamellae of glass that formed via solid-state transformations. This socalled 'diaplectic' glass becomes pervasive at higher pressures and results in optically isotropic and X-ray-amorphous phases that resemble texturally the original quartz grains (without evidence of melt flow). In the past, it has been shown that the amount of this amorphous material in experimentally shock-loaded quartz correlates with peak shock pressure. Both reports derive the glass content from density measurements of individual crystals employing the equation X(%) = (rho(sub x) - rho(sub 0))/(rho(sub x) - rho(sub gl)), where x and 0 stands for X-ray and average (optical) density, respectively. The density of glass, rho(sub gl), was adopted as 2.2 g/cu cm. Though the same procedures had been applied, the resulting glass content differs significantly among the above studies. In the present study, we are using a new approach based solely on the integral intensity of a single, carefully selected reflection in the XRD pattern, and we will compare our data to those reported in the literature.

Skala, R.↗

Spectrum and chemical composition of the remarkable planetary nebula NGC 6537

The planetary nebula NGC 6537 appears to be an irregular bipolar object. Conventional procedures have been employed to observe the spectrum of NGC 6537 with the image dissector scanner at the Lick 3-m telescope. Both red- and green-sensitive tubes were employed in order to cover the spectrum from the practical UV limit near lambda 3300 A to the near-infrared limit near lambda 8600 A. The instrumental response function was determined on the basis of the observation of suitable comparison stars. On Oct. 23, 1984, observations with the International Ultraviolet Explorer (IUE) were obtained. A table containing the optical region spectrum of NGC 6537 is presented along with a table providing the UV fluxes, a table listing the ionic concentrations, and a table with data describing the chemical composition of NGC 6537. Attention is given to theoretical models and the determination of the nebular chemical composition, and aspects of plasma diagnostics.

Feibelman, W.↗

Approach to SSME health monitoring. II - Exhaust plume emission spectroscopy at the DTF

The Diagnostics Testbed Facility (DTF) located at the Stennis Space Center (SSC) is used for obtaining extensive sets of H2O2 exhaust plume emission spectral data for the SSME critical components related elements and materials. The SSME related elements and materials are simulated by mixing appropriate amounts of compounds of their respective constituent elements in an aqueous solution which is injected into the combustion chamber of the DTFT. Five of the most critical components of the SSME which have experienced very severe wear and tear problems in the past are analyzed. These are high pressure turbopump (HPTP) turbine blades, HPTP turbine disks, HPTP bearing, main injector LOX posts, and the main combustion chamber structural shell. The alloys used in the manufacturing of these components are MAR-M 246 + Hf, Waspaloy X, AISI 440C, Haynes 188, and Inconel 718, respectively. The experimental setup and procedures at the DTF are described; stratospheric data for the five alloys are presented; and strategies for the material identification in the SSME exhaust plume are discussed.

Tejwani, Gopal D.↗