Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Nanowire Thermoelectric Devices

Nanowire thermoelectric devices, now under development, are intended to take miniaturization a step beyond the prior state of the art to exploit the potential advantages afforded by shrinking some device features to approximately molecular dimensions (of the order of 10 nm). The development of nanowire-based thermoelectric devices could lead to novel power-generating, cooling, and sensing devices that operate at relatively low currents and high voltages. Recent work on the theory of thermoelectric devices has led to the expectation that the performance of such a device could be enhanced if the diameter of the wires could be reduced to a point where quantum confinement effects increase charge-carrier mobility (thereby increasing the Seebeck coefficient) and reduce thermal conductivity. In addition, even in the absence of these effects, the large aspect ratios (length of the order of tens of microns diameter of the order of tens of nanometers) of nanowires would be conducive to the maintenance of large temperature differences at small heat fluxes. The predicted net effect of reducing diameters to the order of tens of nanometers would be to increase its efficiency by a factor of .3. Nanowires made of thermoelectric materials and devices that comprise arrays of such nanowires can be fabricated by electrochemical growth of the thermoelectric materials in templates that contain suitably dimensioned pores (10 to 100 nm in diameter and 1 to 100 microns long). The nanowires can then be contacted in bundles to form devices that look similar to conventional thermoelectric devices, except that a production version may contain nearly a billion elements (wires) per square centimeter, instead of fewer than a hundred as in a conventional bulk thermoelectric device or fewer than 100,000 as in a microdevice. It is not yet possible to form contacts with individual nanowires. Therefore, in fabricating a nanowire thermoelectric device, one forms contacts on nanowires in bundles of the order of 10-microns wide. The fill factor for the cross-section of a typical bundle is about 1/2. Nanowires have been grown in alumina templates with pore diameters of 100 and 40 nm.

Borshchevsky, Alexander↗

Method and Apparatus for Providing In-Flight Pilot Interface for Trajectory Optimization

Systems and methods of an in-cockpit flight trajectory modification system for an aircraft are provided. A receiver is capable of receiving flight-related hazard information. A traffic aware planner (TAP) module is operably connected to the receiver to receive the flight-related hazard information. A user interface device is operably connected to the TAP module on board the aircraft to provide trajectory information associated with the aircraft and to receive user input corresponding to a request for a revised trajectory. A TAP application is capable of calculating one or more revised trajectories for the aircraft based at least on active trajectory information of the aircraft and the flight-related hazard information. The user interface device may be configured to display information related to the one or more revised trajectories, including a graphic display of the active trajectory and at least one revised trajectory in a visualization panel of the user interface device.

Burke, Kelly Ann↗

Hot-Electron Photon Counters for Detecting Terahertz Photons

A document proposes the development of hot-electron photon counters (HEPCs) for detecting terahertz photons in spaceborne far-infrared astronomical instruments. These would be superconducting- transition-edge devices: they would contain superconducting bridges that would have such low heat capacities that single terahertz photons would cause transient increases in their electron temperatures through the superconducting- transition range, thereby yielding measurable increases in electrical resistance. Single devices or imaging arrays of the devices would be fabricated as submicron-sized bridges made from films of disordered Ti (which has a superconducting- transition temperature of .0.35 K) between Nb contacts on bulk silicon or sapphire substrates. In operation, these devices would be cooled to a temperature of .0.3 K. The proposed devices would cost less to fabricate and operate, relative to integrating bolometers of equal sensitivity, which must be operated at a temperature of approx. = 0.1 K.

Karasik, Boris↗

Team Electronic Gameplay Combining Different Means of Control

Disclosed are methods and apparatuses provided for modifying the effect of an operator controlled input device on an interactive device to encourage the self-regulation of at least one physiological activity by a person different than the operator. The interactive device comprises a display area which depicts images and apparatus for receiving at least one input from the operator controlled input device to thus permit the operator to control and interact with at least some of the depicted images. One effect modification comprises measurement of the physiological activity of a person different from the operator, while modifying the ability of the operator to control and interact with at least some of the depicted images by modifying the input from the operator controlled input device in response to changes in the measured physiological signal.

Pope, Alan T.↗

High speed direct-binary to binary-coded-decimal converter and scaler

Telemetry (pulse code modulated) digital system usually sends binary numbers representing some parameter that is not value of binary number. Received binary number must be scaled and converted to binary coded decimal to operate readout device to display true value. Group of adders speed up binary number conversion and scaling in one operation.

Toole, P. C.↗

Integrated-Circuit Broadband Infrared Sources

Microscopic devices consume less power, run hotter, and are more reliable. Simple, compact, lightweight, rapidly-responding reference sources of broadband infrared radiation made available by integrated-circuit technology. Intended primarily for use in calibration of remote-sensing infrared instruments, devices eventually replace conventional infrared sources. New devices also replace present generation of miniature infrared sources. Self-passivating nature of poly-crystalline silicon adds to reliability of devices. Maximum operating temperature is 1,000 K, and power dissipation is only one-fourth that of prior devices.

Lamb, G.↗

Suppressing Spurious Reflections In An Interferometer

Dynamic-aperture fringe discriminator is simple device enhancing operation of interferometer of spherical-wave-front type used to test lenses, telescopes, and other optical instruments. Device suppresses reflections from surfaces of refractive optical elements in instrument and/or test setup. Reflections from refractive optical components eliminated by blocking half of interferometer aperture.

Steimle, Lawrence J.↗

Hardware efficient monitoring of input/output signals

A communication device comprises first and second circuits to implement a plurality of ports via which the communicative device is operable to communicate over a plurality of communication channels. For each of the plurality of ports, the communication device comprises: command hardware that includes a first transmitter to transmit data over a respective one of the plurality of channels and a first receiver to receive data from the respective one of the plurality of channels; and monitor hardware that includes a second receiver coupled to the first transmitter and a third receiver coupled to the respective one of the plurality of channels. The first circuit comprises the command hardware for a first subset of the plurality of ports. The second circuit comprises the monitor hardware for the first subset of the plurality of ports and the command hardware for a second subset of the plurality of ports.

Driscoll, Kevin R.↗

Hydrogen/Oxygen Torch Ignitor

Reliable device used to ignite variety of fuels. Used as general-purpose ignitor in other applications, or as hydrogen/oxygen torch. Operation of device straight-forward. Hydrogen and oxygen flow through separate ports into combustion chamber in device, where they ignite by use of surface-gap spark plug. Hot gases flow from this combustion chamber, through injector tube, into larger combustion chamber containing fuel-oxidizer mixture to be ignited.

Repas, George A.↗

Coupled parallel waveguide semiconductor laser

The operation of a new type of tunable laser, where the two separately controlled individual lasers are placed vertically in parallel, has been demonstrated. One of the cavities ('control' cavity) is operated below threshold and assists the longitudinal mode selection and tuning of the other laser. With a minor modification, the same device can operate as an independent two-wavelength laser source.

Katz, J.↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

A 96% Alumina based Packaging System for 500°C Test of SiC Integrated Circuits

With the development of silicon carbide (SiC) sensors and electronic devices for operation at 500°C, compatible packaging technologies are needed for long term high temperature test and deployment of these sensors and electronic devices. 96% Al2O3ceramic is an excellent electrically insulating material with acceptable dielectric constant and low dielectric loss over wide temperature and frequency ranges. This paper presents a packaging system for low power integrated circuits including a prototype 8-I/O chip-level package and printed circuit board (PCB) based on 96% Al2O3ceramic substrates and Au thick-film metallization for 500°C applications. The details related to designs of packages and PCBs, packaging materials, and specific packaging step recipes including wire -bonding and die-attach, are presented. Some test results of this prototype packaging approach applied to SiC integrated circuits at 500°C are reviewed.

High Temperature, Packaging, Alumina, Thick Film↗

A 96% Alumina based Packaging System for 500°C Test of SiC Integrated Circuits

With the development of silicon carbide (SiC) sensors and electronic devices for operation at 500°C, compatible packaging technologies are needed for long term high temperature test and deployment of these sensors and electronic devices. 96% Al2O3 ceramic is an excellent electrically insulating material with acceptable dielectric constant and low dielectric loss over wide temperature and frequency ranges. This paper presents a packaging system for low power integrated circuits including a prototype 8-I/O chip-level package and printed circuit board (PCB) based on 96% Al2O3 ceramic substrates and Au thick-film metallization for 500°C applications. The details related to designs of packages and PCBs, packaging materials, and specific packaging step recipes including wire - bonding and die-attach, are presented. Some test results of this prototype packaging approach applied to SiC integrated circuits at 500oC are reviewed.

high temperature↗

A real-time optical data processing device

The design, operation, and structure of the hybrid field effect light valve, a real-time input device for application to coherent optical data processing (CODP), is described. The device consists of a sandwich of thin films that electrically control the optical birefringence of a thin (2 micrometer) liquid crystal layer. It has high resolution (greater than 100 1/mm), contrast ratio (greater than 100:1), speed (10 sec on, 15 sec off) and input sensitivity (about 0.3 ergs/sq cm) in addition to cost and size advantages. Performance data for a laboratory model are presented.

Jacobson, A.↗

A Spacecraft Housekeeping System-on-Chip in a Radiation Hardened Structured ASIC

Housekeeping systems are essential to health monitoring of spacecraft and instruments. Typically, sensors are distributed across various sub-systems and data is collected using components such as analog-to-digital converters, analog multiplexers and amplifiers. In most cases programmable devices are used to implement the data acquisition control and storage, and the interface to higher level systems. Such discrete implementations require additional size, weight, power and interconnect complexity versus an integrated circuit solution, as well as the qualification of multiple parts. Although commercial devices are readily available, they are not suitable for space applications due the radiation tolerance and qualification requirements. The Housekeeping System-o n-A-Chip (HKSOC) is a low power, radiation hardened integrated solution suitable for spacecraft and instrument control and data collection. A prototype has been designed and includes a wide variety of functions including a 16-channel analog front-end for driving and reading sensors, analog-to-digital and digital-to-analog converters, on-chip temperature sensor, power supply current sense circuits, general purpose comparators and amplifiers, a 32-bit processor, digital I/O, pulse-width modulation (PWM) generators, timers and I2C master and slave serial interfaces. In addition, the device can operate in a bypass mode where the processor is disabled and external logic is used to control the analog and mixed signal functions. The device is suitable for stand-alone or distributed systems where multiple chips can be deployed across different sub-systems as intelligent nodes with computing and processing capabilities.

Suarez, George↗

Conceptual design of a fleet of autonomous regolith throwing devices for radiation shielding of lunar habitats

The National Aeronautics and Space Administration (NASA) in conjunction with Universities Space Research Association (USRA) has requested that the feasibility of a fleet of regolith tossing devices designed to cover a lunar habitat for radiation protection be demonstrated. The regolith, or lunar soil, protects the lunar habitat and its inhabitants from radiation. Ideally, the device will operate autonomously in the lunar environment. To prove the feasibility of throwing regolith on the Moon, throwing solutions were compared to traditional, Earth-based methods for moving soil. Various throwing configurations were investigated. A linear throwing motion combined with a spring and motor energizing system proved a superior solution. Three different overall configurations for the lunar device are presented. A single configuration is chosen and critical parameters such as operating procedure, system volume, mass, and power are developed. The report is divided into seven main sections. First, the Introduction section gives background information, defines the project requirements and the design criteria, and presents the methodology used for the completion of this design. Next, the Preliminary Analysis section presents background information on characteristics of lunar habitats and the lunar environment. Then, the Alternate Designs section presents alternate solutions to each of the critical functions of the device. Fourth, a detailed analysis of throwing the regolith is done to demonstrate its feasibility. Then, the three overall design configurations are presented. Next, a configuration is selected and the conceptual design is expanded to include system performance characteristics, size, and mass. Finally, the Conclusions and Recommendations for Future Work section evaluates the design, outlines the next step to be taken in the design process, and suggests possible goals for future design work.

Armstrong, Karem↗