Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Lunar Surface Material - Spacecraft Measurements of Density and Strength

The relation of the density of the lunar surface layer to depth is probably best determined from spacecraft measurements of the bearing capacity as a function of depth. A comparison of these values with laboratory measurements of the bearing capacity of low-cohesion particulate materials as a function of the percentage of solid indicates that the bulk density at the lunar surface is about 1.1 grams per cubic centimeter and that it increases nearly linearly to about 1.6 grams per cubic centimeter at a depth of 5 centimeters.

Jaffe, L. D.↗

XeF lidar measurements of density and temperature in the middle atmosphere

In recent years, it has been widely recognized that vertically propagating internal gravity waves in the middle atmosphere play an important role in determining the large scale wind field by their momentum transport and deposition. However, very little is known about them in the upper stratosphere and lower mesosphere because of the lack of adequate techinques to observe small scale motions. A XeF excimer laser was used for the Rayleigh lidar observation. The characteristics of the XeF lidar system are given. The wavelength of the XeF laser is in the region that is ozone absorption free, and the Rayleigh scattering cross section is 5 times larger than in 532 nm. The advantages of using the XeF laser as against the YAG laser have been discussed in detail. The density and temperature profiles between the altitude range of 30 and 70 km measured with this lidar system are illustrated. The accuracy is less than + or - 3% and 10k at 60 km for an observation time of 15 min. The results on the gravity waves by the observation through about one year since Apr. 1985 is presented.

Shibata, T.↗

Development and Construction of an Interferometer for Optical Measurements of Density Fields

A method of interference is described in the present report which promises profitable application in aeronautical research. The physical foundation of the method and a simple method of adjustment are briefly discussed. The special technical construction of the instrument is described which guarantees its use also in the case of vibrations of the surrounding space and permits the investigation of unsteady phenomena. It is found that the interference method will make the small differences in density in the flow field around the body even at low speeds. (40 m/sec) optically measurable.

Zobel, Th.↗

Measurement of Density, Sound Velocity, Surface Tension, and Viscosity of Freely Suspended Supercooled Liquids

Non-contact methods have been implemented in conjunction with levitation techniques to carry out the measurement of the macroscopic properties of liquids significantly cooled below their nominal melting point. Free suspension of the sample and remote methods allow the deep excursion into the metastable liquid state and the determination of its thermophysical properties. We used this approach to investigate common substances such as water, o-terphenyl, succinonitrile, as well as higher temperature melts such as molten indium, aluminum and other metals. Although these techniques have thus far involved ultrasonic, electromagnetic, and more recently electrostatic levitation, we restrict our attention to ultrasonic methods in this paper. The resulting magnitude of maximum thermal supercooling achieved have ranged between 10 and 15% of the absolute temperature of the melting point for the materials mentioned above. The physical properties measurement methods have been mostly novel approaches, and the typical accuracy achieved have not yet matched their standard equivalent techniques involving contained samples and invasive probing. They are currently being refined, however, as the levitation techniques become more widespread, and as we gain a better understanding of the physics of levitated liquid samples.

Supercooling Liquids↗

Variation of Derived Mesospheric Nitric Oxide in Relation to Wind and Temperature in Winter

As a good approximation, changes of the NO-density are solely responsible for changes of the non-auroral D-region. Under the assumption that other ion production processes are either known or negligible, one can derive (NO) from electron densities using a suitable effective electron loss rate. In the Winter Anomaly Campaign 1975/76 nineteen rocket payloads carried electron density measurements on fifteen days. On two of these days (NO) was measured in-situ by photometers. For these days one can establish the production not due to Lyman-alpha and NO. This rest production can then be applied to all (NO) derivations based on electron density measurements. In addition, in this campaign winds and temperatures were measured from the ground to approximately the base of the thermosphere. The derived field of NO densities between December 1975 and February 1976 from 70 to 100 km is compared to corresponding fields of winds (zonal and meridional), temperatures, pressure and Richardson numbers.

Friedrich, M.↗

The distribution of neutral hydrogen in the interstellar medium. 1: The data

We compile, from the existing literature, the largest sample to date (842 data points) of hydrogen column density measurements, N(H I), of the gas in the interstellar medium. We include only results obtained from absorption measurements toward individual stars (594 in our sample) in an effort to construct a three-dimensional picture of the interstellar gas. We derive hydrogen column densities toward a fraction of the stars in the sample from published column density measurements of metal ions. A three-dimensional physical model derived from this data set will be presented in a companion paper. The observed stars span distances from a few parsecs to a few thousand parsecs, and more than half of the sample serves to describe the local interstellar medium within a few hundred parsecs of the Sun. Hydrogen column densities range from 10(exp 17) to 10(exp 22)/sq cm. We describe here the various observational methods used to estimate the hydrogen column densities and present the table with the stellar and hydrogen column density data. The provided table is intended as a global reference work, not to introduce new results.

Fruscione, Antonella↗

Analysis of record-breaking low ozone values during the 1997 winter over NDSC Station Lauder, New Zealand

During early August 1997, the ozone column density measured over Lauder was unusually low, with a minimum value of 222 Dobson Units (DU) at August 10. These observations are striking since in August, during the Austral winter, the ozone column density should be heading towards its yearly maximum; The August mean ozone column density measured over Lauder between 1987 and 1996 was 348(+/-28) DU, the lowest monthly average in these ten years was 255 DU. Regular altitude profile measurements of ozone, performed at Network for the Detection of Stratospheric Change (NDSC) station Lauder, make it possible to do a detailed, altitude-resolved, study of the low ozone observations. The measurements show ozone poor air in two altitude regions of the stratosphere: A 'high region', extending from the 600 K to the 1050 K isentrope (25 to 34 km), and a 'low region', below about 550 K (22 km). High resolution reverse trajectory maps of potential vorticity (PV) and ozone mixing ratio, based on the assumption of passive advection by the large-scale three-dimensional winds, show that in the 'high region' the ozone poor air was part of the polar vortex, which was centered off the pole and extended over Lauder for several days, while in the 'low region' the ozone poor air was mixed in from low latitudes. A rapid recovery of the ozone column density, by more than 110 DU within 24 hours, was observed when in the low region an ozone rich filament of the polar vortex moved over Lauder, while in the high region the (ozone poor) high part of the vortex moved away.

Brinksma, E. J.↗

Comparison of calculated and measured ion densities on the dayside of Venus

Data from the Pioneer Venus ion mass spectrometers are compared with model calculations of the ion density distributions appropriate for daytime conditions. The model assumes diffusive equilibrium upper boundary conditions for the major ions (O2(+), O(+), CO2(+), He(+), and H(+)); the agreement between the calculated and measured gross behavior of these ions is reasonably good except for H(+), which may be influenced strongly by convective transport processes. The distributions of five minor ions (C(+), N(+), NO(+), CO(+), and N2(+)) are also calculated for the chemically controlled region (less than approximately 200 km); the agreements are, in general, poor, an indication that the present understanding of the Venus minor ion chemistry is still incomplete.

Nagy, A. F.↗

Emission measures, electron densities, and nonthermal velocities from optically thin UV lines near a quiet solar limb

Calibrated intensities and line widths are presented for 45 optically thin chromospheric and transition-zone UV lines observed in a quiet area near the solar limb. The observations were made over the wavelength range from 1175 to 1915 A with the slit spectrograph on the Skylab Apollo Telescope Mount. Three nonthermal-velocity components are derived from the transition-zone line widths: a main component of 23 km/s and two high-velocity components of 45 and 75 km/s, respectively, which contribute 5% to 10% of the averaged intensity. Absolute intensities are determined as a function of height, emission measures are obtained as functions of height as well as temperature, and electron densities are estimated from density-sensitive line ratios. The densities estimated from different sets of lines are found not to agree with each other, but the values obtained from the Si III multiplet between 1297 and 1301 A are considered to be the most reliable. An atmospheric model with inhomogeneous structures extending high above the solar surface is suggested.

Moe, O. K.↗

Electron beam fluorescence measurements in the Boeing hypersonic shock tunnel

The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.

Price, Linwood L.↗

The effect of a nonuniform planetary albedo on the interpretation of earth radiation budget observations

The flux density measured at satellite altitude with a fixed field of view radiometer differs from the true flux density reflected by the earth-atmosphere system within the field of view of the radiometer. This difference is due to angular response characteristics of the radiometer, solid angle effects due to geometry, and angular reflectance effects of the earth-atmosphere system. All of these effects lead to uncertainties in the interpretation of instantaneous earth radiation budget measurements. The differences between the true flux density and the measured flux density are shown to be significant when the field of view of the radiometer is large and when the atmosphere has a nonuniform, or spatially dependent, reflectance (albedo). A simulation experiment is described whereby the scene within the field of view of a nadir looking sensor is divided into a large number of equal area elements, each of which reflects radiation with one of two different reflectance models (corresponding to cloud-free and cloudy areas). The conditional mean values of the measured flux density, given values of the true flux density, are shown to differ significantly from the conditional means of the inverse problem, that of finding the mean value of the true flux density given a value for the measured flux density. The differences between the true flux density and the measured flux density are examined as a function of satellite altitude, field of view of the radiometer and solar zenith angle (including the effects of a terminator within the field of view) for both Lambertian and non-Lambertian reflectance models.

King, M. D.↗

Electron Densities in Solar Flare Loops, Chromospheric Evaporation Upflows, and Acceleration Sites

We compare electron densities measured at three different locations in solar flares: (1) in Soft X-Ray (SXR) loops, determined from SXR emission measures and loop diameters from Yohkoh Soft X-Ray Telescope maps (n(sub e, sup SXR) = (0.2-2.5) x 10(exp 11)/ cu cm); (2) in chromospheric evaporation upflows, inferred from plasma frequency cutoffs of decimetric radio bursts detected with the 0.1-3 GHz spectrometer Phoenix of ETH Zuerich (n(sub e, sup upflow) = (0.3-11) x 10(exp 10)/cu cm; and (3) in acceleration sites, inferred from the plasma frequency at the separatrix between upward-accelerated (type III bursts) and downward-accelerated (reverse-drift bursts) electron beams [n(sub e, sup acc) = (0.6-10) x 10(exp 9)/cu cm]. The comparison of these density measurements, obtained from 44 flare episodes (during 14 different flares), demonstrates the compatibility of flare plasma density diagnostics with SXR and radio methods. The density in the upflowing plasma is found to be somewhat lower than in the filled loops, having ratios in a range n(sub e, sup upflow)/n(sub e, sup SXR) = 0.02-1.3, and a factor of 3.6 higher behind the upflow front. The acceleration sites are found to have a much lower density than the SXR-bright flare loops, i.e., n(sub e, sup acc)/n(sub e, sup SXR) = 0.005- 0.13, and thus must be physically displaced from the SXR-bright flare loops. The scaling law between electron time-of-flight distances l' and loop half-lengths s, l'/s = 1.4 +/- 0.3, recently established by Aschwanden et al. suggests that the centroid of the acceleration region is located above the SXR-bright flare loop, as envisioned in cusp geometries (e.g., in magnetic reconnection models).

Aschwanden, Markus J.↗