Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Electron and ion density depletions measured in the STS-3 orbiter wake

The third Space Shuttle flight on Columbia carried instrumentation to measure thermal plasma density and temperature. Two separate investigations, the Plasma Diagnostics Package (PDP) and the Vehicle Charging and Potential Experiment (VCAP), carried a Langmuir Probe, and the VCAP also included a Spherical Retarding Potential Analyzer (SRPA). Only those measurements made while the PDP is in the payload bay are discussed here since the VCAP instrumentation remains in the payload bay at all times and the two measurements are compared. The wake behind a large structure (in this case the Space Shuttle Orbiter) flying through the ionospheric plasma is discussed. Much theoretical work was done regarding plasma wakes. The instrumentation on this mission gives the first data taken with a large vehicle in the ionospheric laboratory. First, the PDP Langmuir Probe and its data set will be presented, then the VCAP Langmuir Probe and SRPA with associated data. The agreement between the two data sets is discussed and then followed by some other PDP data which infers an even lower wake density.

Murphy, G. B.↗

X-RAY DENSITOMETER FOR USE IN PLASMA STREAMS

Densitometer for the measurement of mass density of a gas in a localized volume element with application to density measurements in high temperature gas streams

X-RAY DENSITY MEASUREMENT↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗

An Experiment to Study Sporadic Sodium Layers in the Earth's Mesosphere and Lower Thermosphere

The Utah State University / Space Dynamics Lab was funded under a NASA Grant. This investigation has been part of Rockwell Universities Sudden Atom Layer Investigation (SAL). USU/SDL provided an electron density measurement instrument, the plasma frequency probe, which was launched on the vehicle 21.117 from Puerto-Rico in February of 1998. The instrument successfully measured electron density as designed and measurement techniques included in this version of the Plasma Frequency probe provided valuable insight into the electron density structures associated with sudden sodium layers in a collisional plasma. Electron density data was furnished to Rockwell University but no science meetings were held by Rockwell Data from the instrument was presented to the scientific community at the URSI General Session in 1999. A paper is in preparation for publication in Geophysical Research Letters. The following document provides a summary of the experiment and data obtained as a final report on this grant.

Swenson, Charles M.↗

Quantitative measurement of density and velocity in compressible flows using laser-induced iodine fluorescence

A nonintrusive optical technique for the quantitative measurement of molecular density and velocity at a point or in an entire cross-sectional plane of a compressible flowfield is reported. Iodine molecules, seeded into the flowfield reservoir, are excited by a tunable narrow-bandwidth laser and the resulting spatially-resolved fluorescence is collected by a single- or multiple-element detector. A theoretical model for the iodine laser-induced fluorescence process is essential for quantitative measurements and is developed using a rate-equation approach. Density measurements using laser-induced fluorescence are normally complicated by collisional quenching; however, the theory predicts that the off-resonant fluorescent signal is directly proportional to density. Velocity is directly related to the Doppler shift of the iodine absorption line, determined by monitoring the broadband fluorescent signal as the laser is tuned in frequency. Experiments in a steady supersonic flowfield are compared with numerical calculations to demonstrate the accuracy of the approach for density and velocity measurement and the lack of perturbation to the flowfield by the iodine seeding. Extensions of the current approach to density and velocity measurement in lower Mach number flows, to the measurement of pressure and temperature, and to temporally-resolved measurements are discussed.

Mcdaniel, J. C.↗

Characterizing particle-based thermal storage performance using optical methods for use in next generation concentrating solar power plants

Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.

Corona, Javier↗

Measuring the Density Fields around Bright Quasars at z ~ 6 with XQR-30 Spectra

Measuring the density of the intergalactic medium using quasar sight lines in the epoch of reionization is challenging due to the saturation of Ly α absorption. Near a luminous quasar, however, the enhanced radiation creates a proximity zone observable in the quasar spectra where the Ly α absorption is not saturated. In this study, we use 10 high-resolution ( R ≳ 10,000) z ~ 6 quasar spectra from the extended XQR-30 sample to measure the density field in the quasar proximity zones. We find a variety of environments within 3 pMpc distance from the quasars. We compare the observed density cumulative distribution function (CDF) with models from the Cosmic Reionization on Computers simulation and find a good agreement between 1.5 and 3 pMpc from the quasar. This region is far away from the quasar hosts and hence approaching the mean density of the universe, which allows us to use the CDF to set constraints on the cosmological parameter σ 8 = 0.6 ± 0.3. The uncertainty is mainly due to the limited number of high-quality quasar sight lines currently available. Utilizing the more than 200 known quasars at z ≳ 6, this method will allow us to tighten the constraint on σ 8 to the percent level in the future. In the region closer to the quasar within 1.5 pMpc, we find that the density is higher than predicted in the simulation by 1.23 ± 0.17, suggesting that the typical host dark matter halo mass of a bright quasar ( M 1450 < -26.5) at z ~ 6 is .

79 ASTRONOMY AND ASTROPHYSICS↗

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring track densities in lunar grains using image analysis

We have used digitized scanning electron micrographs and computer image analysis programs to measure track densities in lunar soil grains. Tracks were formed by highly ionizing solar energetic particles and cosmic rays. Back-scattered electron images produced suitable high contrast images for analysis. We used computer counting and measurement of area to obtain track densities. We found an excellent correlation with manual measurements for track densities below 1x10(exp 8) cm(exp -2). For track densities between 1x10(exp 8) to 1x10(exp 9) cm(exp -2) we found that a regression formula using the percentage area covered by tracks gave good agreement with manual measurements. Measurement of tract densities in lunar samples has been a very rewarding technique for measuring exposure ages and soil maturation processes. We have shown that we can reliably measure track densities in lunar grains using image analysis techniques. Automating track counting may allow application of this technique to important problems in regolith dynamics including the ratio of radiation exposure to reworking in various surface and core samples and in regolith breccias.

Blanford, G. E.↗

Measurements of density, temperature, and their fluctuations in turbulent supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density, temperature, and their turbulent fluctuation levels were obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment are compared with previous measurements obtained in the same facility using conventional probes and an earlier spectroscopic technique. Densities and temperatures measured with the current technique agree with the previous surveys to within 3 percent and 2 percent, respectively. The fluctuation amplitudes for both variables agree with the measurements obtained using the earlier spectroscopic technique and show evidence of an unsteady, weak shock wave that perturbs the boundary layer.

Fletcher, Douglas G.↗

Land use mapping using edge density texture measures on Thematic Mapper simulator data

Texture analysis was performed as part of an investigation of the information content of Thematic Mapper (TM) imagery. High altitude aircraft scanner imagery from the Airborne Thematic Mapper (ATM) instrument was acquired over central California and used to simulate TM data. Edge density texture images were constructed by computation of proportions of edge pixels in a 31 x 31 moving window on a near infrared ATM band. A training technique was employed to select computational parameters to maximize the difference between edge density measurements in urban and in rural areas. The results of classification of the texture images showed that urban and rural areas could be distinguished with texture alone, indicating that inclusion of texture in automated classification procedures could significantly improve their accuracy.

Hlavka, C. A.↗

A comparison of ionospheric conductances and auroral luminosities observed simultaneously with the Chatanika radar and the DE 1 auroral imagers

Auroral luminosities at vacuum ultraviolet (VUV) wavelengths are combined with simultaneous and coincident ionospheric electron density measurements made by the Chatanika radar to relate ionospheric conductances to optical emissions. The auroral luminosities are obtained along the magnetic meridian through Chatanika with the auroral imaging photometers on the Dynamics Explorer 1 satellite as the radar scans in the magnetic meridian to measure electron density and conductivity as a function of altitude and latitude. The observations are used to determine an empirical relationship between the luminosities measured at VUV wavelengths and the Hall and Pedersen conductances.

Robinson, R. M.↗

Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

Hinghofer-Szalkay, H.↗