Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data sheet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

HEU Metal Delayed Critical Experiments with 10 to 19 Inch Thick Graphite Reflectors

Approximately 100 graphite-reflected highly enriched uranium (HEU, 93.14 wt % 235 U) metal annular and cylindrical critical experiments were performed in the early 1960s at the Oak Ridge Critical Experiments Facility (ORCEF). This report presents details from experiment logbooks, experimental data sheets and the author's memory for 44 HEU metal (93.14 wt % 235 U) critical assemblies with graphite reflectors varying from 10 to 19 in. thick, outside diameters varying from 7 to 15 in., inside diameters varying from 7 to 13 in. and critical HEU metal masses varying from 20.4 to 69.0 kg. The data from the 44 experiments described in this report are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Evaluation Program (ICSBEP) once the uncertainty analysis on the measured k eff is completed. Based on previous ICSBEP benchmarks with this HEU metal at ORCEF, the uncertainties in the measured k eff are expected to be as low as ±0.0004. Preparation of this report is part of an effort at Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented series of critical and subcritical experiments enumerated in Critical and Subcritical NEA Benchmark Possibilities for Measurements at ORCEF and Other US DOE Facilities (Mihalzo, ORNL/TM-2019/1188, 2019) and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities. More than 500 operational days of critical facility time were used, not including setup and dismantlement time. This documentation for a part of one series of graphite reflected highly enriched uranium metal critical experiments, that used 50 operational days of ORCEF time, was performed using funding received from the DOE Office of Nuclear Energy’s Nuclear Energy University Programs at the University of Tennessee Nuclear Engineering Department. This documentation was also supported by the Nuclear Criticality, Radiation Transport, and Safety programs at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Half-life of 67 Cu

The half-life of 67 Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67 Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In search of truth: In memory of Balraj Singh

Born in Punjab (India) in December 1941, Balraj Singh is not only the single most prolific nuclear data evaluator and disseminator of nuclear structure and decay data with 148 evaluations in Nuclear Data Sheets — 85 as the first and often only author — plus other journals, but his upmost curiosity and dedication brought him to be one of the finest nuclear physicists, with an everlasting influence on many of us. Furthermore, Balraj passed away about a year ago on 9 October 2023 in Ottawa, Ontario (Canada) at the age of 81, and at Atomic Data and Nuclear Data Tables we would like to commemorate some of his scientific achievements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gaussian process-based surrogate modeling framework for process planning in laser powder-bed fusion additive manufacturing of 316L stainless steel

Here, Laser Powder-Bed Fusion (L-PBF) metal-based additive manufacturing (AM) is complex and not fully understood. Successful processing for one material, might not necessarily apply to a different material. This paper describes a workflow process that aims at creating a material data sheet standard that describes regimes where the process can be expected to be robust. The procedure consists of building a Gaussian process-based surrogate model of the L-PBF process that predicts melt pool depth in single-track experiments given a laser power, scan speed, and laser beam size combination. The predictions are then mapped onto a power versus scan speed diagram delimiting the conduction from the keyhole melting controlled regimes. This statistical framework is shown to be robust even for cases where experimental training data might be suboptimal in quality, if appropriate physics-based filters are applied. Additionally, it is demonstrated that a high-fidelity simulation model of L-PBF can equally be successfully used for building a surrogate model, which is beneficial since simulations are getting more efficient and are more practical to study the response of different materials, than to re-tool an AM machine for new material powder.

316L stainless steel↗

Guidelines for Transportation, Handling, and Use of Fast Pyrolysis Bio-Oil. Part 1. Flammability and Toxicity

An alternative sustainable fuel, biomass-derived fast pyrolysis oil or 'bio-oil', is coming into the market. Fast pyrolysis pilot and demonstration plants for fuel applications producing tonnes of bio-oil are in operation, and commercial plants are under design. There will be increasingly larger amounts of bio-oil transportation on water and by land, leading to a need for specifications and supporting documentation. Bio-oil is different from conventional liquid fuels, and therefore must overcome both technical and marketing hurdles for its acceptability in the fuels market. A comprehensive Material Safety Data Sheet (MSDS) is required, backed with independent testing and certification. In order to standardise bio-oil quality specifications are needed. The first bio-oil burner fuel standard in ASTM (D7544) was approved in 2009. CEN standardisation has been initiated in Europe. In the EU a new chemical regulation system, REACH (Registration, Evaluation and Authorisation of Chemicals) is being applied. Registration under REACH has to be made if bio-oil is produced or imported to the EU. In the USA and Canada, bio-oil has to be filed under TOSCA (US Toxic Substances Control Act). In this paper the state of the art on standardisation is discussed, and new data for the transportation guidelines is presented. The focus is on flammability and toxicity.

09 BIOMASS FUELS↗

Staff Radiation Doses in a Real-Time Display Inside the Angiography Room

MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operator exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fragranced consumer products and undisclosed ingredients

Fragranced consumer products-such as air fresheners, laundry supplies, personal care products, and cleaners-are widely used in homes, businesses, institutions, and public places. While prevalent, these products can contain chemicals that are not disclosed to the public through product labels or material safety data sheets (MSDSs). What are some of these chemicals and what limits their disclosure? This article investigates these questions, and brings new pieces of evidence to the science, health, and policy puzzle. Results from a regulatory analysis, coupled with a chemical analysis of six best-selling products (three air fresheners and three laundry supplies), provide several findings. First, no law in the U.S. requires disclosure of all chemical ingredients in consumer products or in fragrances. Second, in these six products, nearly 100 volatile organic compounds (VOCs) were identified, but none of the VOCs were listed on any product label, and one was listed on one MSDS. Third, of these identified VOCs, ten are regulated as toxic or hazardous under federal laws, with three (acetaldehyde, chloromethane, and 1,4-dioxane) classified as Hazardous Air Pollutants (HAPs). Results point to a need for improved understanding of product constituents and mechanisms between exposures and effects.

54 ENVIRONMENTAL SCIENCES↗

Fragranced consumer products: Chemicals emitted, ingredients unlisted

Fragranced consumer products are pervasive in society. Relatively little is known about the composition of these products, due to lack of prior study, complexity of formulations, and limitations and protections on ingredient disclosure in the U.S. We investigated volatile organic compounds (VOCs) emitted from 25 common fragranced consumer products-laundry products, personal care products, cleaning supplies, and air fresheners-using headspace analysis with gas chromatography/mass spectrometry (GC/MS). Our analysis found 133 different VOCs emitted from the 25 products, with an average of 17 VOCs per product. Of these 133 VOCs, 24 are classified as toxic or hazardous under U.S. federal laws, and each product emitted at least one of these compounds. For 'green' products, emissions of these compounds were not significantly different from the other products. Of all VOCs identified across the products, only 1 was listed on any product label, and only 2 were listed on any material safety data sheet (MSDS). While virtually none of the chemicals identified were listed, this nonetheless accords with U.S. regulations, which do not require disclosure of all ingredients in a consumer product, or of any ingredients in a mixture called 'fragrance.' Because the analysis focused on compounds emitted and listed, rather than exposures and effects, it makes no claims regarding possible risks from product use. Results of this study contribute to understanding emissions from common products, and their links with labeling and legislation.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Structure and Decay Data for A=167 Isobars

Experimental nuclear spectroscopic data are compiled and evaluated for 17 known nuclides of mass 167 (Sm, Eu, Gd, Tb, Dy, Ho, Er Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt), 23 years after the previous full evaluation by 2000Ba65. Detailed information is presented for each reaction and decay experiment. Combining all the available data, recommended values are provided for energies, spins and parities, and half-lives of levels, with energies, branching ratios and multipolarities of γ radiations, and characteristics of β and α radiations in radioactive decays. Here, the α decays of A=171 nuclei to A=167 daughters are included in this work, while for α decays of A=167 nuclei to A=163 daughters, consult Nuclear Data Sheets (2010Re03) or the ENSDF database for A=163. 167 Er, 167 Tm, 167 Yb, 167 Lu and 167 Ta are among the most extensively studied nuclides via decay and high-spin gamma-ray spectroscopy measurements, followed by 167 Ho, 167 Hf, 167 W, and 167 Os. Information for excited states in 167 Dy, 167 Re, and 167 Ir are limited; no excited states have yet been identified in 167 Sm, 167 Eu, 167 Gd, 167 Tb and 167 Pt, with the ground-state half-life of 167 Sm remaining unknown. This work supersedes the earlier evaluation of A=167 nuclei by 2000Ba65.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Structure and Decay Data for A = 200 Isobars

Evaluated nuclear structure and decay data for all nuclei with mass number A = 200 ( 200 Os, 200 Ir, 200 Pt, 200 Au, 200 Hg, 200 Tl, 200 Pb, 200 Bi, 200 Po, 200 At, 200 Rn, and 200 Fr), are presented. All available experimental data are compiled and evaluated, and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities and transition probabilities, as well as other nuclear properties, are recommended. Inconsistencies and discrepancies that exist in the literature are discussed. A number of computer codes (https://www-nds.iaea.org/public/ensdf pgm/) developed by members of the NSDD network were used during the evaluation process. In conclusion, this work supersedes the earlier evaluation by F.G. Kondev and S. Lalkovski (2007Ko42), published in Nuclear Data Sheets 108, 1471 (2007).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Structure and Decay Data for A=206 Isobars

Here, evaluated nuclear structure and decay data for all nuclei with mass number A=206 ( 206 Pt, 206 Au, 206 Hg, 206 Tl, 206 Pb, 206 Bi, 206 Po, 206 At, 206 Rn, 206 Fr, 206 Ra and 206 Ac), are presented. All available experimental data are compiled and evaluated, and best values for level and γ-ray energies, quantum numbers, lifetimes, γ-ray intensities and transition probabilities, as well as other nuclear properties, are recommended. Inconsistencies and discrepancies that exist in the literature are discussed. A number of computer codes (https://www-nds.iaea.org/public/ensdf_pgm/) developed by members of the NSDD network were used during the evaluation process. This work supersedes the earlier evaluation by F.G. Kondev (2008Ko21), published in Nuclear Data Sheets 109, 1527 (2008).

Kondev, F. G. [Argonne National Laboratory (ANL), ↗

Nuclear Structure and Decay Data for A=175 Isobars

In this article , nuclear structure data for 15 known nuclides of mass number 175 (Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg) have been evaluated, which supersedes the earlier work done by M. Shamsuzzoha Basunia (2004Ba89), published in Nuclear Data Sheets 102, 719 (2004).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature Coefficients of Perovskite Photovoltaics for Energy Yield Calculations

Temperature coefficients for maximum power (TPCE), open circuit voltage (VOC), and short circuit current (JSC) are standard specifications included in data sheets for any commercially available photovoltaic module. To date, there has been little work on determining the TPCE for perovskite photovoltaics (PV). We fabricate perovskite solar cells with a TPCE of -0.08 rel %/°C and then disentangle the temperature-dependent effects of the perovskite absorber, contact layers, and interfaces by comparing different device architectures and using drift-diffusion modeling. A main factor contributing to the small TPCE of perovskites is their low intrinsic carrier concentrations with respect to Si and GaAs, which can be explained by its wider band gap. In this work, we demonstrate that the unique increase in Eg with increasing temperatures seen for perovskites results in a reduction in JSC but positively influences VOC. The current limiting factors for the TPCE in perovskite PV are identified to originate from interfacial effects.

14 SOLAR ENERGY↗

Arduino based radiation survey meter

This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Half-life of {sup 66}Ga

We measured the half-life of {sup 66}Ga by observing positrons from the {beta}{sup +} branch to the ground state of {sup 66}Zn with a superconducting Wu-type beta spectrometer. Our result is t{sub 1/2}=9.304(8)hours, which is the highest-precision measurement to date and disagrees with the Nuclear Data Sheets (NDS) value by over 6{sigma}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Q Value of {sup 115}In->{sup 115}Sn(3/2{sup +}): The Lowest Known Energy beta Decay

Using precision, cryogenic, Penning-trap mass spectrometry we have measured the atomic mass difference M[{sup 115}In]-M[{sup 115}Sn] to be 497.489(10) keV/c{sup 2}. Combined with the energy of the 3/2{sup +} first excited state of {sup 115}Sn[J. Blachot, Nuclear Data Sheets 104, 967 (2005)], the Q value of the {sup 115}In(9/2{sup +})->{sup 115}Sn(3/2{sup +}) beta decay is determined to be 155(24) eV. This confirms the inference of Cattadori et al.[Nucl. Phys. A 748, 333 (2005)] that this small branching-ratio beta decay has the lowest-known Q value. We also report improved values of the individual atomic masses: M[{sup 115}In]=114.903 878 774(16) u and M[{sup 115}Sn]=114.903 344 697(17) u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental and Monte Carlo studies of fluence corrections for graphite calorimetry in low- and high-energy clinical proton beams

Purpose: The aim of this study was to determine fluence corrections necessary to convert absorbed dose to graphite, measured by graphite calorimetry, to absorbed dose to water. Fluence corrections were obtained from experiments and Monte Carlo simulations in low- and high-energy proton beams. Methods: Fluence corrections were calculated to account for the difference in fluence between water and graphite at equivalent depths. Measurements were performed with narrow proton beams. Plane-parallel-plate ionization chambers with a large collecting area compared to the beam diameter were used to intercept the whole beam. High- and low-energy proton beams were provided by a scanning and double scattering delivery system, respectively. A mathematical formalism was established to relate fluence corrections derived from Monte Carlo simulations, using the FLUKA code [A. Ferrari et al., “FLUKA: A multi-particle transport code,” in CERN 2005-10, INFN/TC 05/11, SLAC-R-773 (2005) and T. T. Böhlen et al., “The FLUKA Code: Developments and challenges for high energy and medical applications,” Nucl. Data Sheets 120, 211–214 (2014)], to partial fluence corrections measured experimentally. Results: A good agreement was found between the partial fluence corrections derived by Monte Carlo simulations and those determined experimentally. For a high-energy beam of 180 MeV, the fluence corrections from Monte Carlo simulations were found to increase from 0.99 to 1.04 with depth. In the case of a low-energy beam of 60 MeV, the magnitude of fluence corrections was approximately 0.99 at all depths when calculated in the sensitive area of the chamber used in the experiments. Fluence correction calculations were also performed for a larger area and found to increase from 0.99 at the surface to 1.01 at greater depths. Conclusions: Fluence corrections obtained experimentally are partial fluence corrections because they account for differences in the primary and part of the secondary particle fluence. A correction factor, F(d), has been established to relate fluence corrections defined theoretically to partial fluence corrections derived experimentally. The findings presented here are also relevant to water and tissue-equivalent-plastic materials given their carbon content.

60 APPLIED LIFE SCIENCES↗