Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Transactive Energy System Deployment Over Insecure Communication Links

Here, in this paper, the privacy and security issues associated with the transactive energy system (TES) deployment over insecure communication links are addressed. In particular, it is ensured that 1) individual agents’ bidding information is kept private throughout hierarchical market-based interactions; and 2) any extraneous data injection attack can be quickly and easily detected. An implementation framework is proposed to enable the cryptography-based enhancement of privacy and security for the deployment of any general hierarchical systems including TESs. Under the proposed framework, a unified cryptography-based approach is developed to achieve both privacy and security simultaneously. Specifically, privacy preservation is realized by an enhanced Paillier encryption scheme, where a block design is proposed to significantly improve computational efficiency. Attack detection is further achieved by an enhanced Paillier digital signature scheme, where a stamp-concatenation mechanism is proposed to enable detection of data replace and reorder attacks. Simulation results verify the effectiveness of the proposed cyber-resilient design for transactive energy systems. Note to Practitioners—This paper is motivated by addressing the issues of cyber resiliency for practically deploying transactive energy system (TES) but it is also applicable to the problem of enhancing the privacy and security for any general hierarchical control systems. TES is an emerging control approach that engages energy suppliers and customers through market operations and uses the price to optimally allocate energy resources. While it has been shown to be promising for power system applications, the underlying market-based interactions raise significant concerns of privacy (data leakage) and security (data tampering). However, existing TES works only focus on the coordination mechanism instead of privacy and security issues. This paper proposes a new cryptography-based TES design for practical deployment. Specifically, to protect privacy, individual supply and demand amounts to be exchanged are all encrypted in a particular way such that the original amounts cannot be inferred from the encrypted amounts, while the desired computation for setting the market clearing price can be carried out over the encrypted amounts, thus generating an encrypted result which, when decrypted, matches that of the same computation over the original amounts. To achieve security, for each exchanged data, its sender generates a particular digital signature which is exchanged together with the data. This enables the receiver to automatically detect the integrity by checking whether a mathematical relationship holds for the pair of data and signature. In our future research, we will investigate more challenging scenarios where some suppliers and customers themselves could be corrupted and purposely submit distorted amounts.

97 MATHEMATICS AND COMPUTING↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of the SPAR thermal analyzer on the CYBER-203 computer

The use of the CYBER 203 vector computer for thermal analysis is investigated. Strengths of the CYBER 203 include the ability to perform, in vector mode using a 64 bit word, 50 million floating point operations per second (MFLOPS) for addition and subtraction, 25 MFLOPS for multiplication and 12.5 MFLOPS for division. The speed of scalar operation is comparable to that of a CDC 7600 and is some 2 to 3 times faster than Langley's CYBER 175s. The CYBER 203 has 1,048,576 64-bit words of real memory with an 80 nanosecond (nsec) access time. Memory is bit addressable and provides single error correction, double error detection (SECDED) capability. The virtual memory capability handles data in either 512 or 65,536 word pages. The machine has 256 registers with a 40 nsec access time. The weaknesses of the CYBER 203 include the amount of vector operation overhead and some data storage limitations. In vector operations there is a considerable amount of time before a single result is produced so that vector calculation speed is slower than scalar operation for short vectors.

Robinson, J. C.↗

Unobtrusive Software and System Health Management with R2U2 on a Parallel MIMD Coprocessor

Dynamic monitoring of software and system health of a complex cyber-physical system requires observers that continuously monitor variables of the embedded software in order to detect anomalies and reason about root causes. There exists a variety of techniques for code instrumentation, but instrumentation might change runtime behavior and could require costly software re-certification. In this paper, we present R2U2E, a novel realization of our real-time, Realizable, Responsive, and Unobtrusive Unit (R2U2). The R2U2E observers are executed in parallel on a dedicated 16-core EPIPHANY co-processor, thereby avoiding additional computational overhead to the system under observation. A DMA-based shared memory access architecture allows R2U2E to operate without any code instrumentation or program interference.

Schumann, Johann↗

Dynamic, resilient virtual sensing system and shadow controller for cyber-attack neutralization

An industrial asset may have monitoring nodes (e.g., sensor or actuator nodes) that generate current monitoring node values. An abnormality detection and localization computer may receive the series of current monitoring node values and output an indication of at least one abnormal monitoring node that is currently being attacked or experiencing a fault. An actor-critic platform may tune a dynamic, resilient state estimator for a sensor node and output tuning parameters for a controller that improve operation of the industrial asset during the current attack or fault. The actor-critic platform may include, for example, a dynamic, resilient state estimator, an actor model, and a critic model. According to some embodiments, a value function of the critic model is updated for each action of the actor model and each action of the actor model is evaluated by the critic model to update a policy of the actor-critic platform.

Roychowdhury, Subhrajit↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Transforming Cyber Education thru Open to All Accessible Pathways

Boise State University’s (BSU) Cyber Operations and Resilience CORe program was intentionally designed so that any student, especially non-traditional and non-technical students, with an interest in cybersecurity could have an education and training pathway to enter the cyber workforce. The CORe curriculum focuses on teaching students how to design, apply, and improve cybersecurity through the interaction of people, processes, and technology. CORe is a stackable curriculum with elective credit hours and options for various academic and industry certificates and certifications that enable students to customize their unique career pathway. The CORe program guides students to think about the system being managed, the risks presented, and the dynamic intersection of system elements when considering how to incorporate resilience frameworks in achieving a resilient system. By developing systems thinking, the students gain an understanding of the interdependencies interacting with the operational system. Further, the CORe program encourages students to integrate cybersecurity knowledge with models and frameworks found in other academic disciplines through a unifying systems approach. CORe is designed around the realities of today’s broad cyber landscape: that breaches will occur in any system over time and proactive design of resilience into systems to detect, respond, and recover in a timely and orderly manner is critical. Students are taught to think holistically about cybersecurity focusing on all system elements. CORe is not a traditional cybersecurity degree. CORe is distinguished by the non-traditional engineering, computer science approach to cybersecurity education with the singular focus on infusing resilience operations and transdisciplinary systems thinking principles throughout the curriculum.

99 GENERAL AND MISCELLANEOUS↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Inter-Domain Fusion for Enhanced Intrusion Detection in Power Systems: An Evidence Theoretic and Meta-Heuristic Approach

False alerts due to misconfigured or compromised intrusion detection systems (IDS) in industrial control system (ICS) networks can lead to severe economic and operational damage. However, research using deep learning to reduce false alerts often requires the physical and cyber sensor data to be trustworthy. Implicit trust is a major problem for artificial intelligence or machine learning (AI/ML) in cyber-physical system (CPS) security, because when these solutions are most urgently needed is also when they are most at risk (e.g., during an attack). To address this, the Inter-Domain Evidence theoretic Approach for Inference (IDEA-I) is proposed that reframes the detection problem as how to make good decisions given uncertainty. Specifically, an evidence theoretic approach leveraging Dempster–Shafer (DS) combination rules and their variants is proposed for reducing false alerts. A multi-hypothesis mass function model is designed that leverages probability scores obtained from supervised-learning classifiers. Using this model, a location-cum-domain-based fusion framework is proposed to evaluate the detector’s performance using disjunctive, conjunctive, and cautious conjunctive rules. The approach is demonstrated in a cyber-physical power system testbed, and the classifiers are trained with datasets from Man-In-The-Middle attack emulation in a large-scale synthetic electric grid. For evaluating the performance, we consider plausibility, belief, pignistic, and general Bayesian theorem-based metrics as decision functions. To improve the performance, a multi-objective-based genetic algorithm is proposed for feature selection considering the decision metrics as the fitness function. Finally, we present a software application to evaluate the DS fusion approaches with different parameters and architectures.

42 ENGINEERING↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

SolarSTARTS: Solar-Assisted State-Aware and ResilienT infrastructure System

This final technical report provides a description and results of the design, development, testing, and validation of the Automated Resilience Management System (ARMS) solution, which integrates different systems to collect, store and process relevant information from the power distribution system to automatically manage the operation of multiple energy assets to enhance the resilience of the power grid against high-impact physical incidents (e.g., hurricanes) and cyber threats. The developed solution comprises a suite of novel AI-based algorithms designed to first detect, locate, and classify anomalies by collecting and analyzing data from multiple monitoring and control devices

14 SOLAR ENERGY↗

CEEP (Cyber-Energy Emulation Platform) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Vaughan, Evan↗

Cyber Energy Emulation Platform (CEEP) [SWR-20-102]

NREL's Cyber-Energy Emulation Platform (CEEP) provides the capability to realize cyber-energy security and resilience through automation and orchestration of virtualized systems and software defined networks for the electric grid. CEEP enables testing and validation of grid-security and -control methodologies as the grid evolves to include smart technologies/systems, such as virtualization and containerization of grid components, software defined networking, simulation and co-simulation frameworks, and hardware in the loop. CEEP is a modular system that can be distributed and deployed across different hardware infrastructure sizes and network architectures. For example, CEEP can visualize, emulate, and/or coordinate the Smart-Grid Network Visualization, Intrusion Detection, and Network Healing system. Using CEEP, intrusion-detection and network-self-healing solutions can be deployed at grid control centers, within secure private clouds, and in cyber-energy appliances.

Rivera, Joshua↗

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗