Effect of viscosity on rolling-element fatigue life at cryogenic temperature with fluorinated ether lubricants

Rolling-element fatigue tests were conducted with 12.7-mm-(1/2-in.-) diameter AISI 52100 steel balls in the NASA five-ball fatigue tester, with a maximum hertz stress of 5500 mN/m2 (800 000 psi), a shaft speed of 4750 rpm, lubricant temperature of 200 K (360 R), a contact angle of 20 deg, using four fluorinated ether lubricants of varying viscosities. No statistically significant differences in rolling-element fatigue life occurred using the four viscosity levels. Elastohydrodynamic calculations indicate that values of the lubricant film parameter were approximately 2 or greater.

Dietrich, M. W.↗

Plasma-sprayed, self-lubricating coatings for use from cryogenic temperatures to 870 deg C (1600 deg F)

A plasma-sprayed coating is described with good lubricating properties over a wide temperature range. The coating, designated NASA LUBE PS101, contains silver, nichrome, calcium fluoride, and an oxidation protective glass. Oscillating tests were conducted of self-aligning, plain cylindrical bearings, in which the bore was lined with 0.025 cm (0.010 in.) thick coatings of PS101; these were conducted at a radial load of 3.5 x 10 to the 7th power N/sq m (5000 psi) in nitrogen gas at -107 C (-160 F), in vacuum at room temperature, and in air from room temperature to 870 C (1600 F). Friction coefficients were less than 0.25 in all cases and wear rates were low. The coating is not brittle, and it has adequate oxidation resistance in air to at least 870 C.

Sliney, H. E.↗

Investigation of the fracture mechanism in Ti-5Al-2.5Sn at cryogenic temperatures

The influence of microstructure on the fracture mechanism and plane-strain fracture toughness of Ti-5Al-2.5Sn was studied through the use of fractography and metallographic sectioning techniques. One-inch thick plates of extra low interstitial (ELI) and normal interstitial Ti-5Al-2.5Sn were mill annealed at 815 C followed by either air or furnace cooling. These variations in composition and cooling rate resulted in differences in the volume fraction and internal structure of the iron-stabilized phase, and in the crystallographic texture and ordering of the alpha matrix. The tensile properties of these plates were determined at 20 K, 77 K, and 295 K. The air-cooled ELI plate was the toughest material evaluated.

Vanstone, R. H.↗

Investigation of the fracture mechanism of Ti-5Al-2.5Sn at cryogenic temperatures

Fractography and metallographic sectioning were used to investigate the influence of microstructure on the fracture mechanism and fracture toughness (KIC) of normal interstitial and extra low interstitial (ELI) Ti-5Al-25Sn at 20 K (-423 F) and 77 K (-320 F). Plates of each grade were mill annealed at 815 C followed by either air or furnace cooling. These variations in composition and cooling rate resulted in differences in the volume fraction and internal structure of the dispersed beta phase and in the ordering of the alpha matrix. The ELI alloys were tougher than the normal interstitial plates. KIC of the furnace-cooled ELI plate was 25% lower than that of the air-cooled ELI material. Variations in cooling rate had no influence of KIC of the normal interstitial alloys. Fractography showed that a large portion of the fracture surfaces were covered with elongated dimples. Metallographic sections of specimens deformed at 77 K showed that these features form at the intersections of slip bands or deformation twins with grain or twin boundaries. Ordering and higher interstitial levels increase the local strain in slip bands resulting in void nucleation at lower macroscopic strains and lower KIC values.

Van Stone, R. H.↗

Development of flightweight static face seals for 75.84 MPa /11 000 psi/ pressure and cryogenic temperatures

The development of a static seal configuration to meet the lightweight low-leakage requirements of the Space Shuttle Main Engine (pressure carrying capability of up to 75.84 MPa) is discussed. The design features, fabrication methods, lab testing, and performance of seal are examined. Flange and bolt details of the joint assembly are considered with attention to an ultrasonic technique for measuring preload in the bolts. Methods used for leak testing in the laboratory and in the field are described; the practicality of the procedures is considered. Attention is directed to hydrogen-environment embrittlement and its influence on seal and joint design.

Daniels, C. M.↗

Graphite/polyimide tension tests at elevated and cryogenic temperatures

Interim results for characterizing tension properties of graphite/polyimide laminates are reported. Existing test procedures for resin-matrix composites were evaluated for use through the extreme temperature range indicated above. Of particular concern was the performance of resistance strain gages at the elevated temperatures and tests were carried out to compare their performance against that of a capacitive strain gage. Limited design data are reported for graphite/polyimide laminates which are being produced through the CASTS Project.

Chapman, A. J.↗

A study of optically contacted quartz at cryogenic temperatures

Optical contacting as a method of joining the quartz components of the instruments for the Gravity Probe-B experiment is evaluated. The strength of the bond between optically contacted fused quartz surfaces at liquid helium temperature was investigated. A test apparatus which can be used for making measurements of the tensile strength of these bonds was designed. Results of the tensile pull tests are given and the reliability of such bonds analyzed.

Payne, L. L.↗

Ambient and cryogenic temperature testing of a 32-channel CMOS multiplexer

A 32 channel CMOS multiplexer was tested at room temperature and at liquid helium temperature (4.9 K). Voltage gain of the FET input stage, leakage current, electrical crosstalk, and noise as a function of clock frequency were measured. The voltage gain measured at 4.9 K was slightly higher than that measured at 300 K and was independent of clock frequency at both operating temperatures. The off channel leakage current was 0.23 pA/channel at 4.9 K. Electrical crosstalk between adjacent channels (one on, one off) was quite low. The spot noise at 10 Hz, of the CMOS multiplexer operating in the static mode did not vary significantly with operating temperature. In the dynamic mode (3.2 kHz clock) at room temperature, the spot noise at 10 Hz was substantially higher than that measured in the static mode.

Lee, J. H.↗

Thermal contacts between metal and glass for use at cryogenic temperatures

Thermal contacts designed to cool a 50-cm diam fused-silica mirror to 5 K without serious distortion of the optical surfaces were tested. Rubber cement and copper-filled rubber cement were found to be well suited for maintaining thermal contact between the fused-silica and copper straps. A variety of other adhesives proved to be unreliable because they spalled the glass. The thermal resistances of the rubber cement and copper-filled rubber cement were determined. For the copper-filled rubber cement, the thermal resistances varied from 570 K/W at 60 K to 15,000 K/W at 10 K.

Obrien, K.↗

Electrical performance of semiconductor devices at cryogenic temperatures

The electrical performance of semiconductor devices is examined over the temperature range from 300 to 1.4K The design, fabrication, and testing of p-channel field effective transistors (MOSFET) are emphasized to develop a device that will perform satisfactorily in the temperature range from 4.2 to 1.4K. The current-voltage characteristics of the device are obtained as a function of temperature for varying channel lengths and channel dopant levels. The MOSFET's with average channel lengths of 3.27, 5.68, 8.37, and 11.39 microns are examined. It is indicated that the devices with the shorter channel lengths perform better in the 4 to 20K range than those with the longer channel lengths.

Ventrice, C. A.↗

An experimental investigation of rubbing interaction in labyrinth seals at cryogenic temperature

An experimental program was carried out to address issues related to the observed cracking of the titanium knife edges on the labyrinth seals of the high pressure fuel pump (HPFP) in the Space Shuttle main engine (SSME). Thermal shock experiments were carried out using a jet specimen with geometry similar to the knife edge geometry. These tests demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates. Alternative materials were also experimentally evaluated. These tests provide information which can be used to design improved labyrinth seals for the HPFP of the SSME. In particular, plasma-sprayed aluminum-graphite was found to be significantly better than aluminum alloy seals used at present from the standpoint of rub performance. Ion nitriding of the titanium alloy knife edges was also found to improve rub performance compared with the untreated baseline knife edge material.

Dolan, F. X.↗

A mirror transport mechanism for use at cryogenic temperatures

The Mirror Transport Mechanism (MTM), which supports a pair of dihedral mirrors and moves them in a very smooth and uniform scanning motion normal to a beamsplitter is described. Each scan is followed by a quick flyback and repeat. Material selection, design, and testing of all major components of the MTM are discussed. Flex pivot failures during vibration testing, excessive dihedral platform sag under one g operation, electronic and fiber optic characteristics, and tolerancing considerations are covered. Development of the mechanism has reached the final phase of thermal and vibration qualification. Environmental testing of the complete FIRAS experiment is just beginning.

Stark, Kenneth W.↗

The in-vacuo torque performance of dry-lubricated ball bearings at cryogenic temperatures

The performance of dry-lubricated, angular contact ball bearings in vacuum at a temperature of 20 degrees K has been investigated, and is compared with the in-vacuo performance at room temperatures. Bearings were lubricated using dry-lubricant techniques which have been previously established for space applications involving operations at or near room temperature. Comparative tests were undertaken using three lubricants: molybdenum disulphide, lead, and PTFE. Results obtained using the three lubricants are presented.

Gould, S. G.↗

Far infrared polarizing grids for use at cryogenic temperatures

A technique is proposed for the construction of free-standing wire grids for use as far-IR polarizers. The method involves wrapping a strand of wire around a single cylinder rather than around a pair of parallel rods, thus simplifying the problem of maintaining constant wire tension. The cylinder is composed of three separate pieces which are disassembled at a later stage in the grid-making process. Grids have been constructed using 8-micron-diameter stainless steel wire and a grid spacing of 25 microns. The grids are shown to be reliable under repeated cycling between room temperature and 1.5 K.

Novak, Giles↗

Investigation of microstructural changes in polyetherether-ketone films at cryogenic temperatures by positron lifetime spectroscopy

Microstructural changes in Polyetherether-ketone (PEEK) films were investigated in the temperature ranges of 23 to -196 C, using Positron Lifetime Spectroscopy (PLS) technique. It was determined that the total free volume decreases by about 46 percent in amorphous PEEK samples and about 36 percent in semicrystalline PEEK samples when they are cooled down from room temperature to liquid nitrogen (LN2) temperature. If this trend in reduction in free volume with decreasing temperature continues, as expected, it is surmised that PEEK will be able to withstand cooling down to liquid hydrogen (LH2) temperature without any detrimental effect on its diffusivity for liquid hydrogen.

Singh, Jag J.↗