Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

MO-F-CAMPUS-T-05: Correct Or Not to Correct for Rotational Patient Set-Up Errors in Stereotactic Radiosurgery

Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied to two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.

60 APPLIED LIFE SCIENCES↗

Phase II Corrective Action Investigation Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada, Revision 2 with ROTC 1 and 2

This Phase II CAIP describes new work needed to potentially reduce uncertainty and achieve increased confidence in modeling results. This work includes data collection and data analysis to refine model assumptions, improve conceptual models of flow and transport in a complex hydrogeologic setting, and reduce parametric and structural uncertainty. The work was prioritized based on the potential to reduce model uncertainty and achieve an acceptable level of confidence in the model predictions for flow and transport, leading to model acceptance by NDEP and completion of the Phase II CAI stage of the UGTA strategy.

54 ENVIRONMENTAL SCIENCES↗

Phase II Corrective Action Investigation Plan for Corrective Action 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada, Revision 2 with ROTCs 1, 2, 3

This Phase II CAIP describes new work needed to potentially reduce uncertainty and achieve increased confidence in modeling results. This work includes data collection and data analysis to refine model assumptions, improve conceptual models of flow and transport in a complex hydrogeologic setting, and reduce parametric and structural uncertainty. The work was prioritized based on the potential to reduce model uncertainty and achieve an acceptable level of confidence in the model predictions for flow and transport, leading to model acceptance by NDEP and completion of the Phase II CAI stage of the UGTA strategy.

54 ENVIRONMENTAL SCIENCES↗

Phase II Corrective Action Investigation Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada, Revision 2

This Phase II CAIP describes new work needed to potentially reduce uncertainty and achieve increased confidence in modeling results. This work includes data collection and data analysis to refine model assumptions, improve conceptual models of flow and transport in a complex hydrogeologic setting, and reduce parametric and structural uncertainty. The work was prioritized based on the potential to reduce model uncertainty and achieve an acceptable level of confidence in the model predictions for flow and transport, leading to model acceptance by NDEP and completion of the Phase II CAI stage of the UGTA strategy.

54 ENVIRONMENTAL SCIENCES↗

Author Correction: US oil and gas system emissions from nearly one million aerial site measurements

Correction to: Naturehttps://doi.org/10.1038/s41586-024-07117-5 Published online 13 March 2024 In the version of the article initially published, several errors were present and have been corrected in the HTML and PDF versions of the article and Supplementary Information. The main results, conclusions, and our interpretations of the data remain unchanged. See the new Supplementary Information Section S15 for a more detailed description of the errors corrected and the resulting effects on the analysis. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. The following practices may help researchers conducting similar analyses avoid making similar errors: 1, Clear, accessible documentation explaining the interpretation of all columns in data input tables and all internal variables within the model, 2, Simple cross-check calculations computed before and after unit conversions.

Sherwin, Evan D↗

A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors

Purpose: Detector lag, or residual signal, in a-Si flat-panel (FP) detectors can cause significant shading artifacts in cone-beam computed tomography reconstructions. To date, most correction models have assumed a linear, time-invariant (LTI) model and correct lag by deconvolution with an impulse response function (IRF). However, the lag correction is sensitive to both the exposure intensity and the technique used for determining the IRF. Even when the LTI correction that produces the minimum error is found, residual artifact remains. A new non-LTI method was developed to take into account the IRF measurement technique and exposure dependencies. Methods: First, a multiexponential (N = 4) LTI model was implemented for lag correction. Next, a non-LTI lag correction, known as the nonlinear consistent stored charge (NLCSC) method, was developed based on the LTI multiexponential method. It differs from other nonlinear lag correction algorithms in that it maintains a consistent estimate of the amount of charge stored in the FP and it does not require intimate knowledge of the semiconductor parameters specific to the FP. For the NLCSC method, all coefficients of the IRF are functions of exposure intensity. Another nonlinear lag correction method that only used an intensity weighting of the IRF was also compared. The correction algorithms were applied to step-response projection data and CT acquisitions of a large pelvic phantom and an acrylic head phantom. The authors collected rising and falling edge step-response data on a Varian 4030CB a-Si FP detector operating in dynamic gain mode at 15 fps at nine incident exposures (2.0%-92% of the detector saturation exposure). For projection data, 1st and 50th frame lag were measured before and after correction. For the CT reconstructions, five pairs of ROIs were defined and the maximum and mean signal differences within a pair were calculated for the different exposures and step-response edge techniques. Results: The LTI corrections left residual 1st and 50th frame lag up to 1.4% and 0.48%, while the NLCSC lag correction reduced 1st and 50th frame residual lags to less than 0.29% and 0.0052%. For CT reconstructions, the NLCSC lag correction gave an average error of 11 HU for the pelvic phantom and 3 HU for the head phantom, compared to 14-19 HU and 2-11 HU for the LTI corrections and 15 HU and 9 HU for the intensity weighted non-LTI algorithm. The maximum ROI error was always smallest for the NLCSC correction. The NLCSC correction was also superior to the intensity weighting algorithm. Conclusions: The NLCSC lag algorithm corrected for the exposure dependence of lag, provided superior image improvement for the pelvic phantom reconstruction, and gave similar results to the best case LTI results for the head phantom. The blurred ring artifact that is left over in the LTI corrections was better removed by the NLCSC correction in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗