Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Resolving LDEF's flux distribution: Orbital (debris?) and natural meteoroid populations

A consistent methodology for the collation of data from both penetration and perforation experiments and from data in the Meteoroid and Debris Special Investigator Group (M-D SIG) data-base has led to the derivation of the average impact flux over LDEF's exposure history 1984-1990. Data are first presented for LDEF's N,S,E,W and Space faces ('offset' by 8 deg and 'tilted' by 1 deg respectively). A model fit is derived for ballistic limits of penetration from 1 micron to 1mm of aluminium target, corresponding to impactor masses from 10(exp -18) kg (for rho sub p = 2g/cu cm) to 10(exp -10) kg (for rho sub p = 1g/cu cm). A second order harmonic function is fitted to the N,S,E, and W fluxes to establish the angular distribution at regular size intervals; this fit is then used to provide 'corrected' data corresponding to fluxes applicable to true N,S,E,W and Space directions for a LEO 28.5 degree inclination orbit at a mean altitude of 465 km.

Mcdonnell, J. A. M.↗

Lightning Strike Distance Distribution Beyond a Preexisting Lightning Area

The 45th Weather Squadron (45 WS) asked the Applied Meteorology Unit (AMU) to review the 30-year-old, lightning stand-off distances of 5 nautical miles (nmi) for applicability to today's operations. This was based on the realization that previous lightning strike distance studies did not match how 45 WS issues lightning warnings (Roeder, 2008). The previous lightning distance studies were from the point of origin of the lightning or the average starting location that would tend to be in the core of the thunderstorm. However, the 45 WS issues lightning warnings based on the edge of a preexisting lightning area. Before beginning the AMU project, it took several years to develop a method to calculate a distance distribution beyond a preexisting area (Roeder, 2015). The AMU pulled Lightning Detection and Ranging (LDAR) sensor data from 1/1/2013 to 12/31/2013. This dataset consisted of 37 million individual source data points from the LDAR sensors. Only sources within 50 km north, south, east or west of the LDAR grid center were included in the dataset. This limited the use of LDAR data to that with the greatest accuracy of source detection and increased data processing. Points were grouped into flashes based on spatial and temporal criteria. Based on the sensitivity analysis the AMU performed on the flash clustering algorithm, a time value of 0.3 seconds was found to model flashes adequately. Distance parameters were tested from 1,500 to 7,500 meters (m) in 500 m increments. Distance parameters of both 3,000 m and 4,000 m produced results in the plotting tool that were most representative of the physical behavior of lightning. Thus statistics were gathered for the most representative of these spatial and temporal criteria on the flash size and the polygon expansion distance in order to find the correct data distributions. The best fit curves for the LDAR polygon expansion frequency vs. distances for both the 3 kilometer (km) and 4 km distance threshold values were exponential decay functions and had R2 values of > 0.998, indicating good model fits. The equations of the best fit curves were then used to calculate a desired safety radius of 4 nmi for either 3 km or 4 km distance threshold criteria. The AMU analysis concludes the safe reduction of the 5 nmi lightning warning circles to 4 nmi should improve the operational impact by 36% if based on distance from the center of the property area being protected. If based on the edge of the property being protected, then the reduction is 4.5 nmi to 4 nmi and the operational impact is decreased by 21%. For the 6 nmi lightning warning circles, the recommended 4 nmi stand-off distance will result in a safe reduction of operational impact of 31% if based on the center of the area being protected, or 16% if based on the edge of the property.

Flash clustering algorithm↗

MO-G-17A-01: Innovative High-Performance PET Imaging System for Preclinical Imaging and Translational Researches

Purpose: To develop a practical and compact preclinical PET with innovative technologies for substantially improved imaging performance required for the advanced imaging applications. Methods: Several key components of detector, readout electronics and data acquisition have been developed and evaluated for achieving leapfrogged imaging performance over a prototype animal PET we had developed. The new detector module consists of an 8×8 array of 1.5×1.5×30 mm{sup 3} LYSO scintillators with each end coupled to a latest 4×4 array of 3×3 mm{sup 2} Silicon Photomultipliers (with ∼0.2 mm insensitive gap between pixels) through a 2.0 mm thick transparent light spreader. Scintillator surface and reflector/coupling were designed and fabricated to reserve air-gap to achieve higher depth-of-interaction (DOI) resolution and other detector performance. Front-end readout electronics with upgraded 16-ch ASIC was newly developed and tested, so as the compact and high density FPGA based data acquisition and transfer system targeting 10M/s coincidence counting rate with low power consumption. The new detector module performance of energy, timing and DOI resolutions with the data acquisition system were evaluated. Initial Na-22 point source image was acquired with 2 rotating detectors to assess the system imaging capability. Results: No insensitive gaps at the detector edge and thus it is capable for tiling to a large-scale detector panel. All 64 crystals inside the detector were clearly separated from a flood-source image. Measured energy, timing, and DOI resolutions are around 17%, 2.7 ns and 1.96 mm (mean value). Point source image is acquired successfully without detector/electronics calibration and data correction. Conclusion: Newly developed advanced detector and readout electronics will be enable achieving targeted scalable and compact PET system in stationary configuration with >15% sensitivity, ∼1.3 mm uniform imaging resolution, and fast acquisition counting rate capability for substantially improved imaging and quantification performance for small animal imaging and image-guided radiotherapy applications. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FunMC^2: A Filter for Uncertainty Visualization of Marching Cubes on Multi-Core Devices

Visualization is an important tool for scientists to extract understanding from complex scientific data. Scientists need to understand the uncertainty inherent in all scientific data in order to interpret the data correctly. Uncertainty visualization has been an active and growing area of research to address this challenge. Algorithms for uncertainty visualization can be expensive, and research efforts have been focused mainly on structured grid types. Further, support for uncertainty visualization in production tools is limited. In this paper, we adapt an algorithm for computing key metrics for visualizing uncertainty in Marching Cubes (MC) to multi-core devices and present the design, implementation, and evaluation for a Filter for uncertainty visualization of Marching Cubes on Multi-Core devices (FunMC2). FunMC2 accelerates the uncertainty visualization of MC significantly, and it is portable across multi-core CPUs and GPUs. Evaluation results show that FunMC2 based on OpenMP runs around 11× to 41× faster on multi-core CPUs than the corresponding serial version using one CPU core. FunMC2 based on a single GPU is around 5× to 9× faster than FunMC2 running by OpenMP. Moreover, FunMC2 is flexible enough to process ensemble data with both structured and unstructured mesh types. Furthermore, we demonstrate that FunMC2 can be seamlessly integrated as a plugin into ParaView, a production visualization tool for post-processing.

Wang, Jay↗

Trends in the Vertical Distribution of Ozone: A Comparison of Two Analyses of Ozonesonde Data

We present the results of two independent analyses of ozonesonde measurements of the vertical profile of ozone. For most of the ozonesonde stations we use data that were recently reprocessed and reevaluated to improve their quality and internal consistency. The two analyses give similar results for trends in ozone. We attribute differences in results primarily to differences in data selection criteria and in utilization of data correction factors, rather than in statistical trend models. We find significant decreases in stratospheric ozone at all stations in middle and high latitudes of the northern hemisphere from 1970 to 1996, with the largest decreases located between 12 and 21 km, and trends of -3 to -10 %/decade near 17 km. The decreases are largest at the Canadian and the most northerly Japanese station, and are smallest at the European stations, and at Wallops Island, U.S.A. The mean mid-latitude trend is largest, -7 %/decade, from 12 to 17.5 km for 1970-96. For 1980-96, the decrease is more negative by 1-2 %/decade, with a maximum trend of -9 %/decade in the lowermost stratosphere. The trends vary seasonally from about 12 to 17.5 km, with largest ozone decreases in winter and spring. Trends in tropospheric ozone are highly variable and depend on region. There are decreases or zero trends at the Canadian stations for 1970-96, and decreases of -2 to -8 %/decade for the mid-troposphere for 1980-96; the three European stations show increases for 1970-96, but trends are close to zero for two stations for 1980-96 and positive for one; there are increases in ozone for the three Japanese stations for 1970-96, but trends are either positive or zero for 1980-96; the U.S. stations show zero or slightly negative trends in tropospheric ozone after 1980. It is not possible to define reliably a mean tropospheric ozone trend for northern mid-latitudes, given the small number of stations and the large variability in trends. The integrated column trends derived from the sonde data are consistent with trends derived from both surface based and satellite measurements of the ozone column.

Loogan, J. A.↗

Toward the analytic bootstrap of energy correlators

In this paper, we present a framework for the analytic bootstrap of three-point energy correlators, a crucial observable in $\mathcal{N}$ = 4 super Yang-Mills theory and quantum chromodynamics (QCD). Our approach combines spherical contour techniques, general physical constraints such as pole cancellations, and power correction data in the singular limits to determine its analytic expression. In contrast to previous bootstrap studies restricted to scattering amplitudes for supersymmetric theories, our framework makes use of the properties of Feynman integrals, marking a significant step toward bootstrapping realistic QCD observables. Using this method, we derive analytic expressions for leading-order three-point energy correlators in the multi-collinear limit with equal and unequal energy weights, where the latter are crucial ingredients for projected N -point energy correlators. We also apply the recently developed technique of analytic regression with lattice reduction as a way to bypass needing explicit expressions for the singular limits. Bridging theoretical advances in scattering amplitudes with the renewed interest in weighted cross-sections, our work opens the door to precision tests of QCD dynamics through analytic event-shape predictions.

jet substructure↗

Searches for lepton-flavour-violating decays of the Higgs boson into $eτ$ and $μτ$ in $ \sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

This paper presents direct searches for lepton flavour violation in Higgs boson decays, H → eτ and H → μτ, performed using data collected with the ATLAS detector at the LHC. The searches are based on a data sample of proton-proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 138 fb –1 . Leptonic (τ → ℓν ℓ ν τ ) and hadronic (τ → hadrons ν τ ) decays of the τ-lepton are considered. Two background estimation techniques are employed: the MC-template method, based on data-corrected simulation samples, and the Symmetry method, based on exploiting the symmetry between electrons and muons in the Standard Model backgrounds. No significant excess of events is observed and the results are interpreted as upper limits on lepton-flavour-violating branching ratios of the Higgs boson. The observed (expected) upper limits set on the branching ratios at 95% confidence level, $\mathcal{B}$(H → eτ) < 0.20% (0.12%) and $\mathcal{B}$(H → μτ ) < 0.18% (0.09%), are obtained with the MC-template method from a simultaneous measurement of potential H → eτ and H → μτ signals. The best-fit branching ratio difference, $\mathcal{B}$(H → μτ) → $\mathcal{B}$(H → eτ), measured with the Symmetry method in the channel where the τ-lepton decays to leptons, is (0.25 ± 0.10)%, compatible with a value of zero within 2.5σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of high-pressure CO 2 sorption isotherms on Eastern and Western US coals

Accurate estimation of carbon dioxide (CO 2 ) sorption capacity of coal is important for planning the CO 2 sequestration efforts. In this work, we investigated sorption and swelling behavior of several Eastern and Western US coal samples from the Central Appalachian Basin and from San Juan Basin. The CO 2 sorption isotherms have been completed at 55°C for as received and dried samples. The role of mineral components in coal, the coal swelling, the effects of temperature and moisture, and the error propagation have been analyzed. Changes in void volume due to dewatering and other factors such as temporary caging of carbon dioxide molecules in coal matrix were identified among the main factors affecting accuracy of the carbon dioxide sorption isotherms. The (helium) void volume in the sample cells was measured before and after the sorption isotherm experiments and was used to build the volume-corrected data plots.

01 COAL, LIGNITE, AND PEAT↗

Developing a 20-year high-resolution wind data set for Puerto Rico

The purpose of this study is to develop a high-resolution wind resource data set for Puerto Rico as part of the wind resource assessment in the Puerto Rico Grid Resilience and Transition to 100 % Renewable Energy Study (PR100) project. The Weather and Research and Forecasting (WRF) is used to model 20-years (2001-2020) of wind resource data on a 3-km grid for the Puerto Rico region. Because accurately representing the planetary boundary layer (PBL)-physics in the WRF is key to accurately model low-level wind speed, 11 different PBL schemes are examined and evaluated to find a WRF configuration that can provide the most accurate wind data. The modeled wind speeds are validated with buoy observations, and the Shin-Hong PBL scheme is selected to generate the final wind data set. Here, the overall results demonstrate that the high-resolution data correctly represents the climate of Puerto Rico (e.g., a dominant easterly trade wind). At 160 m above ground, the southern regions of Puerto Rico show strong offshore wind speed (>8 m/s on average) throughout the daytime and nighttime. For land-based wind, average wind speed ranges from 5 m/s-7 m/s during daytime, whereas notable high wind speeds (>9 m/s) appear in the mountain regions during nighttime.

17 WIND ENERGY↗

A novel apparatus for in situ compression of submicron structures and particles in a high resolution SEM

We report on the development and characterization of a novel in situ manipulation device to perform stressing experiments on the submicron scale inside a high resolution field emission scanning electron microscope. The instrument comprises two main assembly groups: an upper part for positioning and moving a mounted probe and a force sensor as well as a specimen support as lower part. The upper part consists of a closed loop tripod piezoelectric scanner mounted on a self-locking coarse positioning stage. Two interlocked steel springs and a linear variable differential transformer measuring the springs' deflections compose the lower part of the instrument. This arrangement acts as force-sensor and sample support. In comparison to already well-established concepts a wide measuring range is covered by adjusting the spring constant between 30 N/m and 50000 N/m. Moreover, the new device offers striking advantages with respect to force calibration and sample deformation measurements. Force calibration is performed using the eigenfrequency of the force detection system directly inside the SEM. Deformation data are obtained with high accuracy by simultaneously recording displacements above and below the specimen. The detrimental apparatus compliance is determined, and the influence on measured data subsequently minimized: an easy to validate two-springs-in-series model is used for data correction. A force resolution in normal direction of 100 nN accompanied by a sample deformation resolution of 5 nm can be achieved with the instrument using an appropriate load cell stiffness. The capabilities and versatility of this instrument are exemplified by compression experiments performed on submicron amorphous silica particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nondestructive detection and characterization of carbonation in concrete

Exposure of concrete to the environment leads to changes in composition, microstructure, and properties; these effects often start from the surface of a concrete structure. A specific, widespread environmental effect is carbonation, where carbon dioxide penetrates the surface of concrete and reacts with calcium hydroxide that is a product of Portland cement hydration in concrete. Carbonation is of interest not only because it can lead to the initiation of reinforcement corrosion, but also carbon is increasingly used during curing to alter the surface properties of cement-based materials as a method to 'sink' carbon in cement-based materials. Nonlinear Rayleigh surface wave measurements are performed on uncarbonated and carbonated concrete samples to assess any mechanical changes induced by carbonation,. In order to minimize the effects of contact conditions, the generated signals are detected by a noncontact air-coupled transducer (100 kHz) at locations along the propagation axis. The nonlinearity parameter, β is used to quantitatively characterize the degree of carbonation. To more accurately analyze the data, corrections are made for the effects of attenuation and diffraction. A comparison between the carbonated and uncarbonated samples demonstrates that pores and micro-cracks are affected by the carbonation product and these significantly change the measured nonlinearity parameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

CONTRIBUTION OF THE ACCRETION DISK, HOT CORONA, AND OBSCURING TORUS TO THE LUMINOSITY OF SEYFERT GALAXIES: INTEGRAL AND SPITZER OBSERVATIONS

We estimate the relative contributions of the supermassive black hole (SMBH) accretion disk, corona, and obscuring torus to the bolometric luminosity of Seyfert galaxies, using Spitzer mid-infrared (MIR) observations of a complete sample of 68 nearby active galactic nuclei (AGNs) from the INTEGRAL all-sky hard X-ray (HX) survey. This is the first HX-selected (above 15 keV) sample of AGNs with complementary high angular resolution, high signal-to-noise, MIR data. Correcting for the host galaxy contribution, we find a correlation between HX and MIR luminosities: L{sub 15{mu}m}{proportional_to}L{sup 0.74{+-}0.06}{sub HX}. Assuming that the observed MIR emission is radiation from an accretion disk reprocessed in a surrounding dusty torus that subtends a solid angle decreasing with increasing luminosity (as inferred from the declining fraction of obscured AGNs), the intrinsic disk luminosity, L{sub Disk}, is approximately proportional to the luminosity of the corona in the 2-300 keV energy band, L{sub Corona}, with the L{sub Disk}/L{sub Corona} ratio varying by a factor of 2.1 around a mean value of 1.6. This ratio is a factor of {approx}2 smaller than for typical quasars producing the cosmic X-ray background. Therefore, over three orders of magnitude in luminosity, HX radiation carries a large, and roughly comparable, fraction of the bolometric output of AGNs. We estimate the cumulative bolometric luminosity density of local AGNs at {approx}(1-3) Multiplication-Sign 10{sup 40} erg s{sup -1} Mpc{sup -3}. Finally, the Compton temperature ranges between kT{sub c} Almost-Equal-To 2 and Almost-Equal-To 6 keV for nearby AGNs, compared to kT{sub c} Almost-Equal-To 2 keV for typical quasars, confirming that radiative heating of interstellar gas can play an important role in regulating SMBH growth.

79 ASTRONOMY AND ASTROPHYSICS↗

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing↗

DISENTANGLING PLANETS AND STELLAR ACTIVITY FOR GLIESE 667C

Gliese 667C is an M1.5V star with a multi-planet system, including planet candidates in the habitable zone. The exact number of planets in the system is unclear, because the existing radial velocity (RV) measurements are known to contain contributions from stellar magnetic activity. Following our analysis of Gliese 581, we have analyzed the effect of stellar activity on the HARPS/HARPS-TERRA RVs of GJ 667C, finding a significant RV-activity correlation when using the width (FWHM) of the HARPS cross-correlation function to trace the magnetic activity. When we correct for this correlation, we confirm the detections of the previously observed planets b and c in the system, while simultaneously ascribing the RV signal near 90 days ({sup p}lanet d{sup )} to an artifact of the stellar rotation. We are unable to confirm the existence of the additional RV periodicities described in Anglada-Escudé et al. in our activity-corrected data.

79 ASTRONOMY AND ASTROPHYSICS↗

Charged pion photoproduction with the {Delta}(1232) baryon beyond the resonance region

We investigate the charged pion photoproduction off the proton target with the {Delta}(1232) baryon, i.e., {gamma}p{yields}{pi}{sup -{Delta}++}(1232) and {gamma}p{yields}{pi}{sup +{Delta}0}(1232), based on the effective Lagrangian method, beyond the resonance region, {radical}(s) > or approx. 2 GeV. We employ the {pi}- and {rho}-meson Regge trajectories in the t channel, in addition to the proton and {Delta} pole, in the s and u channels, respectively, and the contact-interaction contributions. A specific scheme for the form factor which satisfies the Ward-Takahashi identity, crossing symmetry, and on-shell condition is taken into account. We also consider a smooth interpolation between the Regge and Feynman propagators for the t-channel meson exchanges as a function of the Mandelstam variable s. We present the numerical results for the energy and angular dependences of the cross sections and the double- and single-polarization observables. It turns out that the present framework reproduces the experimental data qualitatively very well. In particular, the interpolation between the two propagators plays a crucial role in reproducing the high-energy experimental data correctly. The {pi}{sup +} decay-angle distribution is also studied using the {Delta}{sup ++}-decay frame, i.e., the Gottfried-Jackson frame. The present results will be a useful guide for future high-energy photon-beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical Improvements in PV Degradation Rate Determination

As photovoltaic (PV) penetration of the power grid increases, it becomes vital to know how decreased power output may affect cost over time. In order to predict power delivery, the decline or degradation rates must be determined accurately. For non-spectrally corrected data several complete seasonal cycles (typically 3-5 years) are required to obtain reasonably accurate degradation rates. In a rapidly evolving industry such a time span is often unacceptable and the need exists to determine degradation rates accurately in a shorter period of time. Occurrence of outliers and data shifts are two examples of analytical problems leading to greater uncertainty and therefore to longer observation times. In this paper we compare three methodologies of data analysis for robustness in the presence of outliers, data shifts and shorter measurement time periods.

14 SOLAR ENERGY↗