Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “core drill”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Folded Resonant Horns for Power Ultrasonic Applications

Folded horns have been conceived as alternatives to straight horns used as resonators and strain amplifiers in power ultrasonic systems. Such systems are used for cleaning, welding, soldering, cutting, and drilling in a variety of industries. In addition, several previous NASA Tech Briefs articles have described instrumented drilling, coring, and burrowing machines that utilize combinations of sonic and ultrasonic vibrational actuation. The main advantage of a folded horn, relative to a straight horn of the same resonance frequency, is that the folded horn can be made shorter (that is, its greatest linear dimension measured from the outside can be made smaller). Alternatively, for a given length, the resonance frequency can be reduced. Hence, the folded-horn concept affords an additional degree of design freedom for reducing the length of an ultrasonic power system that includes a horn.

Sherrit, Stewart↗

Precision Subsampling System for Mars Surface Missions

The ability to analyze heterogeneous rock samples at fine spatial scales would represent a powerful addition to our planetary in situ analytical toolbox. This is particularly true for Mars, where the signatures of past environments and, potentially, habitability are preserved in chemical and morphological variations across sedimentary layers and among mineral pr.ases in a given rock specimen. On Earth, microbial life often associates with surfaces at the interface of chemical nutrients, and ultimately retains sub-millimeter to millimeter-scale layer confinement in fossilization. On Mars, and possibly other bodies, trace chemical markers (elemental, organic/molecular, isotopic, chiral, etc.) and fine-scale morphological markers (e.g., micro-fossils) may he too subtle, degraded, or ambiguous to be detected, using miniaturized instrumentation, without some concentration or isolation. This is because (i) instrument sensitivity may not be high enough to detect trace markers in bulk averages; and (ii) instrument s~lectiviry may not be sufficient to distinguish such markers from interfering/counteracting signals from the bulk. Moreover from a fundamental chemostratigraphic perspective there would be a great benefit to assessing specific chemical and stable isotopic gradients, over millimeter-to-centimeter scales and beyond, with higher precision than currently possible in situ. We have developed a precision subsampling system (PSS) that addresses this need while remaining relatively flexible to a variety of instruments that may take advantage of the capability on future missions. The PSS is relevant to a number of possible lander/rover missions, especially Mars Sample Return. Our specific PSS prototype is undergoing testing under Mars ambient conditions, on a variety of natural analog rocks and rock drill cores, using a set of complementary flight-compatible measurement techniques. The system is available for testing with other contact instruments that may benefit from precision sampling.

Mahaffy, P. R.↗

System of extraction of volatiles from soil using microwave processes

A device for the extraction and collection of volatiles from soil or planetary regolith. The device utilizes core drilled holes to gain access to underlying volatiles below the surface. Microwave energy beamed into the holes penetrates through the soil or regolith to heat it, and thereby produces vapor by sublimation. The device confines and transports volatiles to a cold trap for collection.

Ethridge, Edwin C.↗

Lunar Water Resource Demonstration (LWRD)

Lunar Water Resource Demonstration (LWRD) is part of RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction). RESOLVE is an ISRU ground demonstration: (1) A rover to explore a permanently shadowed crater at the south or north pole of the Moon (2) Drill core samples down to 1 meter (3) Heat the core samples to 150C (4) Analyze gases and capture water and/or hydrogen evolved (5) Use hydrogen reduction to extract oxygen from regolith

Muscatello, Anthony C.↗

Selection, Development and Results for The RESOLVE Regolith Volatiles Characterization Analytical System

The RESOLVE project requires an analytical system to identify and quantitate the volatiles released from a lunar drill core sample as it is crushed and heated to 150 C. The expected gases and their range of concentrations were used to assess Gas Chromatography (GC) and Mass Spectrometry (MS), along with specific analyzers for use on this potential lunar lander. The ability of these systems to accurately quantitate water and hydrogen in an unknown matrix led to the selection of a small MEMS commercial process GC for use in this project. The modification, development and testing of this instrument for the specific needs of the project is covered.

Lueck, Dale E.↗

A Mars Sample Return Sample Handling System

We present a sample handling system, a subsystem of the proposed Dragon landed Mars Sample Return (MSR) mission [1], that can return to Earth orbit a significant mass of frozen Mars samples potentially consisting of: rock cores, subsurface drilled rock and ice cuttings, pebble sized rocks, and soil scoops. The sample collection, storage, retrieval and packaging assumptions and concepts in this study are applicable for the NASA's MPPG MSR mission architecture options [2]. Our study assumes a predecessor rover mission collects samples for return to Earth to address questions on: past life, climate change, water history, age dating, understanding Mars interior evolution [3], and, human safety and in-situ resource utilization. Hence the rover will have "integrated priorities for rock sampling" [3] that cover collection of subaqueous or hydrothermal sediments, low-temperature fluidaltered rocks, unaltered igneous rocks, regolith and atmosphere samples. Samples could include: drilled rock cores, alluvial and fluvial deposits, subsurface ice and soils, clays, sulfates, salts including perchlorates, aeolian deposits, and concretions. Thus samples will have a broad range of bulk densities, and require for Earth based analysis where practical: in-situ characterization, management of degradation such as perchlorate deliquescence and volatile release, and contamination management. We propose to adopt a sample container with a set of cups each with a sample from a specific location. We considered two sample cups sizes: (1) a small cup sized for samples matching those submitted to in-situ characterization instruments, and, (2) a larger cup for 100 mm rock cores [4] and pebble sized rocks, thus providing diverse samples and optimizing the MSR sample mass payload fraction for a given payload volume. We minimize sample degradation by keeping them frozen in the MSR payload sample canister using Peltier chip cooling. The cups are sealed by interference fitted heat activated memory alloy caps [5] if the heating does not affect the sample, or by crimping caps similar to bottle capping. We prefer cap sealing surfaces be external to the cup rim to prevent sample dust inside the cups interfering with sealing, or, contamination of the sample by Teflon seal elements (if adopted). Finally the sample collection rover, or a Fetch rover, selects cups with best choice samples and loads them into a sample tray, before delivering it to the Earth Return Vehicle (ERV) in the MSR Dragon capsule as described in [1] (Fig 1). This ensures best use of the MSR payload mass allowance. A 3 meter long jointed robot arm is extended from the Dragon capsule's crew hatch, retrieves the sample tray and inserts it into the sample canister payload located on the ERV stage. The robot arm has capacity to obtain grab samples in the event of a rover failure. The sample canister has a robot arm capture casting to enable capture by crewed or robot spacecraft when it returns to Earth orbit

Wilson, David↗

Revisiting the West Clearwater Lake Impact Structure, Canada

The West and East Clearwater Lake impact structures are two of the most distinctive and recognizable impact structures on Earth. Known regionally as the "Clearwater Lake Complex", these structures are located in northern Quebec, Canada (56 deg 10 N, 74 deg 20 W) approximately 125 km east of Hudson Bay. The currently accepted diameters are 36 km and 26 km for the West and East structures, respectively. Long thought to represent a rare example of a double impact, recent age dating has called this into question with ages of approximately 286 Ma and approximately 460-470 Ma being proposed for the West and East structures, respectively. Relatively little is known about the East Clearwater Lake structure. There is no surface exposure and what information there is comes from geophysics and two drill cores obtained in the 1960s. In contrast, the West Clearwater Lake structure is relatively well preserved with large ring of islands in the approximately 30 km diameter lake. Much of the work done on West Clearwater stems from field investigations carried out in 1977 driven by the Apollo program, with a focus on the impact melt rocks and other impactites, which are well exposed on the ring of islands. To our knowledge, the Clearwater Lake impact structures have not been the focus of detailed impact geology field investigations since the 1977 expedition and the only geological map that exists is from the 1960s and is at the reconnaissance level. Our knowledge of impact cratering processes have increased substantially since this time, as have the analytical techniques available for samples. This provided the motivation for a joint Canadian-US-UK expedition to the West Clearwater Lake impact structure in August and September 2015, under the auspices of the FINESSE (Field Investigations to Enable Solar System Science and Exploration) project, part of NASA's Solar System Exploration Research Virtual Institute (SSERVI). We focus here on the impactites of the West Clearwater Lake impact structure. Other ongoing studies, also presented at this conference, focus on central uplift formation, the impact-generated hydrothermal system, xxxx and using WCIS as an analog test site for crew studies of sampling protocols].

West Clearwater Lake↗

Auto-Gopher: A Wireline Deep Sampler Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

The ability to penetrate subsurfaces and perform sample acquisition at depth of meters may be critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of enabling acquisition of samples from depths of several meters where if used on Mars would be beyond the oxidized and sterilized zone. For this purpose, we developed a rotary-hammering coring drill, called Auto-Gopher, which employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor that rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that can be fed into and retrieved from the drilled hole using a winch and a cable. It includes an inchworm anchoring mechanism allowing the drill advancement and weight on bit control without twisting the reeling and power cables. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The design and fabrication of this device were presented in previous publications. This paper presents the results of laboratory and field tests and lessons learned from this development.

piezoactuation↗

Metabolic Potential and Activity in Fluids of the Coast Range Ophiolite Microbial Observatory, California, USA

Metabolic potential and activity associated with hydrogen and carbon monoxide were characterized in fluids sampled from the the Coast Range Ophiolite Microbial Observatory (CROMO). CROMO consists of two clusters of science-dedicated wells drilled to varying depths up to 35m in the actively serpentinizing, Jurassic-age Coast Range Ophiolite of Northern California, along with a suite of pre-existing monitoring wells at the same site. Consistent with the fluid chemistry observed in other serpentinizing systems, CROMO fluids are highly alkaline, with pH up to 12.5, high in methane, with concentrations up 1600 micromolar, and low in dissolved inorganic carbon (DIC), with concentrations of 10's to 100's of micromolar. CROMO is conspicuous for fluid H2 concentrations that are consistently sub-micromolar, orders of magnitude lower than is typical of other systems. However, higher H2 concentrations (10's -100's of micromolar) at an earlier stage of fluid chemical evolution are predicted by, or consistent with: thermodynamic models for fluid chemistry based on parent rock composition equivalent to local peridotite and with water:rock ratio constrained by observed pH; the presence of magnetite at several wt% in CROMO drill cores; and concentrations of formate and carbon monoxide that would require elevated H2 if formed in equilibrium with H2 and DIC. Calculated Gibbs energy changes for reaction of H2 and CO in each of several metabolisms, across the range of fluid composition encompassed by the CROMO wells, range from bioenergetically feasible (capable of driving ATP synthesis) to thermodynamically unfavorable. Active consumption relative to killed controls was observed for both CO and H2 during incubation of fluids from the pre-existing monitoring wells; in incubations of freshly cored solids, consumption was only observed in one sample set (corresponding to the lowest pH) out of three. The specific metabolisms by which H2 and CO are consumed remain to be determined.

Hydrogen↗

Carbon and Sulfur Isotopic Signatures of Ancient Life and Environment at the Microbial Scale: Neoarchean Shales and Carbonates

An approach to coordinated, spatially resolved, in situ carbon isotope analysis of organic matter and carbonate minerals, and sulfur three- and four-isotope analysis of pyrite with an unprecedented combination of spatial resolution, precision, and accuracy is described. Organic matter and pyrite from eleven rock samples of Neoarchean drill core express nearly the entire range of delta(sup 13)C, delta(sup 34)S, Delta(sup 33)S, and Delta(sup 36)S known from the geologic record, commonly in correlation with morphology, mineralogy, and elemental composition. A new analytical approach (including a set of organic calibration standards) to account for a strong correlation between H/C and instrumental bias in SIMS delta(sup 13)C measurement of organic matter is identified. Small (2-3 microns) organic domains in carbonate matrices are analyzed with sub-permil accuracy and precision. Separate 20- to 50-micron domains of kerogen in a single approx. 0.5 cu cm sample of the approx. 2.7 Ga Tumbiana Formation have delta(sup 13)C = −52.3 +/- 0.1per mille and −34.4 +/- 0.1per mille, likely preserving distinct signatures of methanotrophy and photoautotrophy. Pyrobitumen in the approx. 2.6 Ga Jeerinah Formation and the approx. 2.5 Ga Mount McRae Shale is systematically 13C-enriched relative to co-occurring kerogen, and associations with uraniferous mineral grains suggest radiolytic alteration. A large range in sulfur isotopic compositions (including higher Delta(sup 33)S and more extreme spatial gradients in Delta(sup 33)S and Delta(sup 36)S than any previously reported) are observed in correlation with morphology and associated mineralogy. Changing systematics of delta(sup 34)S, Delta(sup 33)S, and Delta(sup 36)S, previously investigated at the millimeter to centimeter scale using bulk analysis, are shown to occur at the micrometer scale of individual pyrite grains. These results support the emerging view that the dampened signature of mass-independent sulfur isotope fractionation (S-MIF) associated with the Mesoarchean continued into the early Neoarchean, and that the connections between methane and sulfur metabolism affected the production and preservation of S-MIF during the first half of the planet's history.

isotopic signatures↗

Mars 2020 Sampling and Caching Subsystem Environmental Development Testing and Preliminary Results

The Environmental Development Testing program supported the development test efforts of the Mars 2020 Sampling and Caching Subsystem from May to November 2015. The engineering prototype Brassboard Corer was attached to a five degree-of-freedom robotic arm to execute a 96-test matrix of ambient and low pressure tests in the 10 ft. thermal vacuum chamber at the NASA Jet Propulsion Laboratory, California Institute of Technology. The Pretest, Test, and Post Test procedures are described, and some preliminary results are discussed. Data and observations from this test campaign inform the future development of the software and hardware toward the Mars 2020 flight design, including the next iteration of the rock coring drill, the Engineering Development Unit Corer.

Kriechbaum, Kristo↗

Thermal design of the sample handling assembly in the sampling and caching subsystem on the Mars 2020 rover

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to collect a set of Martian regolith samples for potential future return to Earth. Regolith and rock samples will be collected and placed into sample tubes using a coring drill, located at the end of a large Robotic Arm, on the outside of the rover. Filled sample tubes will be transferred from the outside of the Rover into the Adaptive Caching Assembly (ACA), located inside the Rover chassis, via the Bit Carousel. Once the filled sample tube is brought into the ACA, the Sample Handling Assembly (SHA) will transfer it to all of the internal processing stations of the ACA for volume assessment, sealing and finally drop-off on the Martian surface. The ACA is a volume within the rover chassis that is not temperature-controlled. Actuators inside the SHA and its End Effector (EE) must be warmed to above -55°C and -25°C, respectively, prior to use. This paper discusses the thermal design of the SHA that uses heaters and temperature sensors to warm up and maintain the temperature-sensitive arm components within temperature limits during operation. Thermal performance predictions for Mars surface operations are also presented.

Lee, Chern-Jiin↗

In-Space Inspection Needs: Opportunities for advanced NDE tools such as x-ray CT for additively manufactured parts, in-situ resource utilization, geological applications, and more

It is now 50 years since the first human presence on the surface of the Moon and as we strive to return with women and men in the next few years, we embrace new technical challenges, goals, and innovative solutions to address 21st century objectives. These new ambitions carry fresh challenges and risks, with the field of NDE playing an increasingly more relevant role towards meeting these essential goals. In recent years, more advanced NDE tools have triggered a rapid expansion of applications for the space industry. In particular, x-ray Computed Tomography (CT) has proven to be a trusted and powerful asset for spaceflight hardware inspection, as well as applied geotechnical analysis for natural materials (e.g., rocks, soils) for NASA and across industry. However, such methods have yet to be extended to “deep space” applications such as those that are now part of the US National Space Policy Directive (SPD-1) and the accelerated push to return humans to the Moon (i.e., Artemis). For this reason, advancing these powerful Earth-based laboratory methods via new technologies, integrated computational solutions, and creative engineering approaches is directly aligned with national space policies, as well as with multiple NASA Strategic Plan priorities. The use of x-ray CT at scales as fine as a few microns or smaller can identify spacecraft part failure modes relevant to quality assurance for flight hardware and AM parts such as those recently developed for ISS. This technology could also identify valuable metallic phases within geological materials (i.e., rocks or drill cores), enabling resource-relevant triage of samples for In-Situ Resource Utilization (ISRU) and high science value sample return to Earth laboratories. There is also significant application for 3D imaging tools for medical use such as inspecting protective gear as well as bone density degradation studies which are critical in establishing a sustained presence in space. Timing for development of these tools for space use is advantageous as we prepare for new opportunities in the next few years and recognize recent commercial technology advancements which make it feasible. Moreover, as NASA strives to take full advantage of developments in AM technologies, including In-Space Manufacturing (ISM), it is widely recognized that NDE tools such as CT will play an essential role in acceptance of these parts for widespread use. New in-space 3D inspection tools with complimentary technology such as AI-based automated feature recognition (accelerated by machine learning), rapid compositional analysis, and advanced sample manipulation, would be a game-changing step toward a new class of crew-based laboratory sensors once human outposts on the Moon are established.

In-Space Non-Destructive Evaluation↗

Verifying Mars 2020 Sampling and Caching Robotic Functions with Position Budgeting Process and Tool

The Mars 2020 Perseverance Rover was launched on July 30th, 2020 with one of the most complex robotic systems ever implemented on an interplanetary mission. Much of this robotic complexity resides in the Rover Sampling and Caching Subsystem (SCS) to enable collection of Martian samples for eventual return to earth and preparation of surfaces for close-up surface science observations. Two robotic arms are used by SCS: the large Robotic Arm (RA) positions the coring drill and science instruments mounted to the Turret for surface interactions, and the smaller Sample Handling Assembly (SHA) manipulates Sample Tube Assemblies (STA) within the Adaptive Caching Assembly (ACA) to prepare them for sample collection, processing, and hermetic sealing. The robotic arms interact with the Martian surface and other SCS components in many ways and in a variety of configurations, with positioning accuracy requirements ranging from tens of millimeters for some surface interactions down to sub-millimeter accuracy for some ACA interactions.This paper describes the process and tool used to calculate the SCS robotic interaction positioning budgets and verify the as-built hardware when delivered. To ensure that these robotic systems are able to perform their tasks, each robotic interaction with another element was broken down into its composite functions. To calculate a positioning budget margin for each function, an allowable was defined and then compared to the list of error sources that contribute to misalignment. Across the subsystem, over 250 functions were identified to be assessed, with almost 500 error sources feeding into their budget calculations. In addition to using as-built values in the budgets for SCS Verification and Validation (V&V) after the hardware was complete, these budgets were populated with design data during the design phase to identify areas of concern and guide hardware design to ensure positive position budget margins.Because of the size of the SCS team that had inputs to the positioning budgets and the sheer number of items in the budgets that needed to be created, updated, and verified, having a tool that would allow for simultaneous access and robust data integrity and processing was imperative. To accomplish this, a web-based MySQL database was created that allowed users to create function position budgets, link individual errors and allowables to them, and view function position budget margin reports. Each error and allowable records data for lateral, normal, angular, and clocking errors, with the ability to add as-built data for up to four different hardware builds. Margin reports can be generated for either design values alone or replacing design data with as-built data when available. These as-built reports are used for final verification of the SCS positioning requirements. Ultimately, the SCS positioning budget process and database tool led to successful interactions during test and an SCS robotic system that is ready to perform sample acquisition and caching on the surface of Mars.

Williams, Jeffrey↗

Mars 2020 Perseverance Rover SHERLOC Instrument Isolation System

The NASA Jet Propulsion Laboratory (JPL) successfully landed the Mars 2020 Perseverance Rover at Jezero Crater on the Martian surface. Perseverance’s main mission objective is to cache Martian rock and regolith samples in hermetically sealed tubes to be brought back to Earth by future missions. To achieve this goal the rover is equipped with a 2-meter-long Robotic Arm (RA) which manipulates the Turret to interact with the surface. The Turret is comprised of science instruments and tools that enable surface sampling and science. The backbone of the Turret hardware is the Rotary Percussive Coring Drill. The science instruments, which are directly mounted to the structural housing of this drill, must be able to withstand not only the launch and entry, descent and landing (EDL) loads of the vehicle but also the dynamic percussive environment, induced by the drill throughout surface operations. This paper discusses the technical hardware design, development and testing of a vibration isolation system to protect the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Instrument from these dynamic environments. The hardware design aspect of this problem was limited by both size and mass constraints. The Turret is tightly configured and the physical space in which hardware can reside is restricted due to multiple axes of surface interaction points. Another driving requirement is the extreme range of thermal non-operational environment from -135C to +90C. This, in addition to SHERLOC being a heavier instrument than previously integrated on a turret, made the use of isolation systems employed on previous rover missions problematic. The final design incorporates custom wire mesh springs preloaded within titanium hexapod struts equipped with flexure ends. Custom versions of commercially available wire mesh springs were designed and tested. These custom springs differed in dimension, density and stiffness from the off the shelf options. The newly designed springs went through various stages of flight acceptance testing. Detailed physics-based modeling to understand what loads the isolation system would experience was used to define the test conditions for the springs and entire isolation subsystem. The testing program developed around this was extensive to fully characterize the isolation performance over cleanliness levels, temperature and life. Another major aspect of this work was developing a method of replicating the drill’s percussive environment for performance and life testing of Turret mounted hardware. Attaching the instrument to an operating drill for testing was not a viable option. A method of using a Highly Accelerated Life Test (HALT) table was developed and applied across the project as the most representative and tunable option to physically simulate this new environment. This method, along with launch environment random vibration testing, was used to build an entire dynamic qualification and flight hardware test program. The results of the design, modeling, testing and analysis of the SHERLOC Isolation System is described throughout the following paper.

Krafchak, Todd↗

Protracted oxygenation across the Cambrian–Ordovician transition: A key initiator of the Great Ordovician Biodiversification Event?

Fluctuations in marine oxygen concentrations have been invoked as a primary driver for changes in biodiversity throughout Earth history. Expansions in reducing marine conditions are commonly invoked as key causal mechanisms for mass extinctions, while increases in marine oxygenation are becoming an increasingly common causal mechanism invoked for biodiversification events. Here we utilize a multiproxy approach to constrain local and global marine paleoredox conditions throughout the late Cambrian–Early Ordovician from two drill core successions in Baltoscandia. Local paleoredox proxies such as manganese concentrations and iron speciation reveal that both sites in the Baltic paleobasin had persistently anoxic and predominantly euxinic (anoxic and sulfidic) bottom water conditions throughout the study interval. Corresponding trace metal datasets indicate nuanced contraction and expansion of global anoxic and euxinic conditions along continental margins during the late Cambrian–Early Ordovician. Lastly, thallium isotope data from these locally reducing sections suggest a global expansion of oxygenated shelf and deeper marine environments from the late Cambrian into the Early Ordovician. This evidence for increasingly oxic marine environments coincides with increases in burrowing depth and tiering in marine animals, as well as diversification of body fossils throughout this ~8-million-year interval. The collective geochemical datasets provide some of the first direct paleoredox evidence for an increase in marine oxygen concentrations as a key mechanism for the Ordovician radiation of marine life

anoxia↗

Experimental Evaluation of Actinide Transport in a Fractured Granodiorite

The objective of this study was to demonstrate and evaluate new experimental methods for quantifying the potential for actinide transport in deep fractured crystalline rock formations. We selected a fractured granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model system because field experiments have already been conducted with uranium and additional field experiments using other actinides are planned at the site. Thus, working on this system provides a unique opportunity to compare lab experiment results with fieldscale observations. Rock cores drilled from the GTS were shipped to Los Alamos National Laboratory, characterized by x-ray diffraction and microscopy, and used in batch sorption and column breakthrough experiments. Solutions with pH 6.8 and 8.8 were tested. Solutions were switched to radionuclide-free synthetic Grimsel groundwater after near-steady actinide/colloid breakthrough occurred in column experiments. We are currently evaluating actinide adsorption/desorption rates as a function of water chemistry (initial focus on pH), with future testing planned to evaluate the influence of carbonate concentrations, flow rates, and mineralogy in solutions and suspensions with bentonite colloids. (auth)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗