Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing EnergyPlus capabilities to model dynamic building envelopes using python plugin

Nearly half of the energy consumption in the United States is related to buildings, resulting in an urgent need to develop innovative technologies to improve building energy efficiency. Dynamic building envelopes, comprising switchable insulation and thermal energy storage materials, have been proposed recently as a promising solution to reduce buildings' heating and cooling loads by thermally coupling the indoor environment with the ambient environment when beneficial while decoupling them when outdoor conditions are not favorable. Although various related technologies are still underway, the whole-building energy modeling tools, like EnergyPlus, do not have the capability to simulate the transient and dynamic nature of dynamic envelope materials and components to accurately predict their impact on building energy use. The objective of this study is to formulate a method in EnergyPlus simulation engine to model multilayer envelopes, comprising dynamic building materials with variable thermophysical properties, and discuss the changes made to the program using a Python plugin. Furthermore, the thermal performance of the dynamic envelopes using the proposed method is compared and verified with the results from a well-established commercial code, COMSOL Multiphysics. A parametric assessment is also conducted to evaluate the energy efficiency benefits of dynamic envelopes in a single-family residential building, demonstrating total annual energy savings up to 11.6 %, when a dynamic envelope operates alone, and up to 18.2 % when it is combined with a thin layer of phase change material as a thermal storage medium. Finally, a United States wide energy efficiency assessment is presented to showcase the geographical spread of the energy savings. The method designed and implemented in this study provides the researchers with the ability to implement their dynamic insulation methods in EnergyPlus and evaluate the whole building energy impact.

25 ENERGY STORAGE↗

Low-cost phase change material as an energy storage medium in building envelopes: Experimental and numerical analyses

A promising approach to increasing the energy efficiency of buildings is the implementation of a phase change material (PCM) in the building envelope. Numerous studies over the last two decades have reported the energy saving potential of PCMs in building envelopes, but their wide application has been inhibited, in part, by their high cost. This article describes a novel PCM made of naturally occurring fatty acids/glycerides trapped into high density polyethylene (HDPE) pellets and its performance in a building envelope application. The PCM-HDPE pellets were mixed with cellulose insulation and then added to an exterior wall of a test building in a hot and humid climate, and tested over a period of several months, To demonstrate the efficacy of the PCM-enhanced cellulose insulation in reducing the building envelope heat gains and losses, side-by-side comparison was performed with another wall section filled with cellulose-only insulation. Further, numerical modeling of the test wall was performed to determine the actual impact of the PCM-HDPE pellets on wall-generated heating and cooling loads and the associated electricity consumption. The model was first validated using experimental data and then used for annual simulations using typical meteorological year (TMY3) weather data. Furthermore, this article presents the experimental data and numerical analyses showing the energy-saving potential of the new PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Thermal impact of adhesive-mounted rooftop PV on underlying roof shingles

Adhesive mounting of residential rooftop photovoltaics (PV) is an alternative to traditional rack mounting that reduces installation costs. Adhesive mounting is fast, simple and reduces the need for skilled labor. In our novel design that further reduces the installation costs, a lightweight (glassless and frameless) PV module is directly adhered to a shingled roof using an adhesive tape, creating a <5 mm air gap between the PV back-panel and the roof shingle surface. Although the gap is sufficient for moisture and rainwater transport under the PV panel, potential heat buildup under the module may adversely impact the long-term durability of the shingles. Heat buildup may also increase the heat flux through the roof, resulting in an overall increase in building cooling loads. This study investigates the thermal behavior of the roof under an adhered PV system. Two identical test huts with dark shingle-covered roofs were located in the hot, desert climate of Albuquerque, NM. Adhesively-mounted lightweight PV modules were installed on the south-facing roof of one of the test huts (PV hut), with the other one serving as a reference hut. During the summer season, the asphalt roof shingles under the PV modules experienced a 13 °C reduction in daytime peak temperature compared with the exposed shingles. No evidence of heat buildup under the PV module was observed. It was also found that the temperature of shingles underneath the adhesive was up to 6 °C higher than for shingles underneath the gap space at the daily peak time. Thin but ventilated air gap between the PV back-panel and the roof shingles helped remove the heat, while the adhesive pads (patches) served as thermal bridges between the PV module and the roof. Daily peak heat flow through the attic ceiling was almost 49% lower in the PV hut compared to the reference hut. These results show no evidence of an adverse thermal impact of the adhesive-mounted PV system on the roofing materials, while demonstrating a potential for a notable reduction in space conditioning energy requirements.

14 SOLAR ENERGY↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent energy buildings based on RES and nanotechnology

The paper presents the design features, the energy modelling and optical performance details of two pilot Intelligent Energy Buildings, (IEB). Both are evolution of the Zero Energy Building (ZEB) concept. RES innovations backed up by signal processing, simulation models and ICT tools were embedded into the building structures in order to implement a new predictive energy management concept. In addition, nano-coatings, produced by TiO2 and ITO nano-particles, were deposited on the IEB structural elements and especially on the window panes and the PV glass covers. They exhibited promising SSP values which lowered the cooling loads and increased the PV modules yield. Both pilot IEB units were equipped with an on-line dynamic hourly solar radiation prediction model, implemented by sensors and the related software to manage effectively the energy source, the loads and the storage or the backup system. The IEB energy sources covered the thermal loads via a south façade embedded in the wall and a solar roof which consists of a specially designed solar collector type, while a PV generator is part of the solar roof, like a compact BIPV in hybrid configuration to a small wind turbine.

14 SOLAR ENERGY↗

Clamp cell with in situ pressure monitoring for low-temperature neutron scattering measurements

In this study, a clamp pressure cell for neutron scattering experiments at low temperatures and in external magnetic fields under pressure up to 2 GPa has been fabricated and tested. The cell provides optical access to the sample space that allows instantaneous pressure determination during sample loading, cooling and measuring using ruby and/or samarium doped strontium tetraborate fluorescence monitoring. Additionally, a new calibration curve of the pressure-induced shift of the 7 D 0 - 5 F 0 (0-0) line in the fluorescent spectrum of SrB 4 O 7 :Sm 2+ for moderate pressures, P≤2 GPa, is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic and Mechanical Design of a 15-T Large Aperture Dipole Magnet for Cable Testing

© 2019 IEEE. A large aperture Nb 3 Sn dipole is proposed to replace the magnet assembly of EDIPO, which was irreversibly damaged in 2016. The goal is to generate a background field of 15 T at 4.2 K in a clear aperture of approximately 100×150 mm 2 and over a uniform length of 1000 mm in order to test superconducting cables for both fusion and high-energy physics applications. The magnet features a block-type coil design wound with wide Rutherford cable (two alternative coil cross sections are considered) and supported by a mechanical structure based on keys-and-bladders technology. In the end regions, the coils tilt up (flare) through a hard-way bend of the cables to provide room for the test well, following a layout already adopted in the LBNL HD2 and CERN-CEA FRESCA2 magnets. The two considered coil design alternatives aim at minimizing the mechanical stress in the coil windings. One coil pack design makes the use of two double pancake coils per pole, whereas the other alternative features three double pancakes per pole. Both design options are presented focusing on the results of numerical computations carried out with finite-element models to investigate peak stresses in the coils during room-temperature pre-loading, cool down, and powering.

Sarasola, Xabier (ORCID:0000000324306939)↗

Low-bay Lighting Energy Conservation Measures

This software requires inputs of simple low-bay lighting system inventory information and calculates the energy and cost benefits of various retrofit opportunities. This tool includes energy conservation measures for: Low-wattage T8 lighting retrofit, T12 to T8 lighting retrofit, LED Exit signs retrofit, Occupancy sensors, Screw-in lighting retrofit, and central lighting controls. This tool calculates energy savings, demand reduction, cooling load reduction, heating load increases, cost savings, building life cycle costs including: Simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

Ian Metzger, JesseDean↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates

Traditional thermal designs of building envelope assemblies are based on static energy flows, yet building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles and their dynamic operation can decrease thermal efficiency. Design work supporting the development of low-energy houses showed that conventional insulations may not always be the most cost effective solution to improvement envelope thermal performance. PCM-enhanced building envelopes that simultaneously reduce the total cooling loads and shift the peak-hour loads are the focus of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Generation High Density Thermal Battery Based on Advanced Metal Hydride

In a world that is facing an energy crisis and environmental pollution, the development of an electric vehicle (EV) as zero-emission, energy-efficiency mode of transportation has taken on an accelerated pace. Most of major automotive manufacturers have launched aggressive programs to develop new-generation EVs, and some economical EVs have been commercialized. Moreover, market forecasting has suggested that Hybrid Electric Vehicles (HEVs), Plug-in Hybrid Electric Vehicles (PHEVs), and Electric Vehicles (EV), will be a growing component of the US vehicle fleets in the near future. By supplying power to EV, a rechargeable electric battery is one of the most crucial components in EV. However, the capacity and cost of an electric battery represent the highest barriers to wide scale adoption of electric vehicles as the large and expensive batteries needed to provide significant driving range can result in unattractive vehicle design and price points. In addition to the electric energy that has been used in powertrain, a key drain on the electrical battery system of an EV is needed to serve cabin heating and cooling loads. Cabin climate conditioning can significantly reduce the electric range of plug-in and full electric vehicles, by as much as 40% in extreme cases, or inversely and can increase the battery size and cost by a comparable amount for the same range. Therefore, significant reduction in the size/cost of EV batteries or a significant increase in driving range can be enabled by eliminating the need for cabin climate load to draw on the electrical battery system. The work of this project focused on a concept that employs metal hydride materials and chloride-ammonia as energy storage materials to build a new generation thermal battery with sufficient energy density to meet the above requirements. The high-energy density of metal hydride material makes the thermal battery meet the requirements of HVAC system for EB automobiles. The present research focused on a specific on-board application to develop a novel HVAC system for EV. However, the methodology of the thermal battery could be extended to a much broader range of applications, including other transportation vehicles such as long haul trucks, stationary HVAC, solar thermal energy storage systems, and waste heat recovery and storage systems. Multiple prototypes were designed, fabricated, and tested. The results successfully demonstrate the principles of the thermal battery using advanced metal hydrides. The performance of the concept-demonstration-unit showed both high heating/cooling power and high energy densities. Although the feasibility of the “Thermal Battery” has been demonstrated by this project, the commercial applications of this technology remain challenging. Either the volumetric or the gravimetric energy density of the materials used often cannot be both met. The solution to this problem is to work with vehicle HAVC designers to identify design innovations that can take advantages of the thermal battery without compromising the performance of the vehicles.

25 ENERGY STORAGE↗

Cost Analysis of Simple Phase Change Material-Enhanced Building Envelopes in Southern U.S. Climates

Traditional thermal designs of building envelope assemblies are based on static energy flows, yet building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles and their dynamic operation can decrease thermal efficiency. Design work supporting the development of low-energy houses showed that conventional insulations may not always be the most cost effective solution to improvement envelope thermal performance. PCM-enhanced building envelopes that simultaneously reduce the total cooling loads and shift the peak-hour loads are the focus of this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗