Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Microstructural Evolution and ORR Activity of Nanocolumnar Platinum Thin Films with Different Mass Loadings Grown by High Pressure Sputtering

Nanocolumnar platinum thin films (Pt-TFs) with different Pt mass loadings were grown by high pressure sputtering (HIPS) and investigated as oxygen reduction reaction (ORR) electrocatalysts for polymer electrolyte membrane fuel cell applications. Mass loading was controlled by changing the sputter deposition time. A cauliflower-like columnar microstructure was achieved by depositing the Pt-TFs onto a microporous layer (MPL)-like surface composed of carbon particles in order to mimic catalyst-coated gas diffusion electrodes. Microstructural evolution of HIPS Pt-TFs and their ORR activity were investigated. Electrochemical characterization of the nanocolumnar Pt-TFs was performed by cyclic voltammetry and rotating disk electrode measurements on Pt-TF/MPL-like-layer/glassy-carbon samples in an aqueous perchloric acid electrolyte. The electrochemically active surface area increased from 18 to 39 m 2 g –1 as the Pt mass loading was decreased. Specific activity of the films was similar (~600 μA cm –2 ) for all Pt mass loadings, due to the similar nanoparticle sizes of ~5 nm as observed by transmission electron microscopy and X-ray diffraction. Furthermore, mass activity of the films increased from 0.11 to 0.26 A mg –1 as the Pt mass loading was decreased, which is an indication of the effective Pt utilization and better access through the catalyst layer at lower Pt mass loadings.

08 HYDROGEN↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. A wave energy converter (WEC) should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Furthermore, the WEC should be adaptable to different sea states. Herethis work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. It is hypothesized that opening the flaps should result in load shedding at the base of the support structure by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. Increased loads at the structure’s natural period can be mitigated by an axial power take-off damping acting as an additional design parameter to control the loads at the WEC’s support structure.

16 TIDAL AND WAVE POWER↗

Integrated ELM and divertor power flux control using RMPs with low input torque in EAST in support of the ITER research plan

Experiments have been carried out at the EAST tokamak to study ITER-relevant scenario integration issues, related to edge localized mode (ELM) control in H-mode plasmas by the application of three-dimensional (3D) resonant magnetic perturbations (RMPs), which have a large impact on the execution of the ITER research plan. The EAST experiments have successfully demonstrated ELM suppression at normalized torque inputs similar to ITER. The application of RMP fields with high toroidal mode number (n = 4) reduces the impact of ELM control on energy and particle confinement compared to those use lower n (n = 1, 2) RMPs. Injection of successive pellets is found to be effective in increasing the plasma density in ELM-suppressed H-modes and reducing the divertor power without triggering large ELMs at EAST. Access to high recycling and radiative divertor conditions while maintaining ELM suppression has been demonstrated in EAST by the use of gas fuelling and neon impurity seeding. Both approaches have been found to be effective in reducing power fluxes to the divertor strike points in near-separatrix lobes for both n = 2 and n = 4 RMPs. Furthermore, reduction of power fluxes in off-separatrix lobes is only effective for n = 4 RMP application, which is consistent with magnetic topology modelling (including plasma response) results showing a shallow penetration into the confined plasma region of field lines connected to these lobes compared to n = 2. The EAST results support the use of high n 3D fields for ELM suppression in ITER high Q DT scenarios since they provide optimum integration features regarding energy and particle confinement, pellet fuelling, radiative divertor operation while eliminating ELM transient power loads and being compatible with low torque input.

pellet fuelling↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of thermal treatment on structure and catalytic performance of ceria-zirconia supported copper oxide (CuO x /Ce y Zr 1-y O 2 ) catalysts for CO oxidation

Copper oxide (CuO x ) supported on ceria-zirconia (Ce y Zr 1-y O 2 , y = 1.0, 0.5, 0.0) catalysts were investigated to elucidate the effects of thermal treatment on their physicochemical properties and catalytic performance in carbon monoxide (CO) oxidation. Here, the catalysts were synthesized via a one-pot chemical vapor deposition (OP-CVD) method at 700˚C and 900˚C with controlled Cu loading. Characterization techniques, including synchrotron X-ray diffraction (S-XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), inductively coupled plasma spectroscopy (ICP), and N 2 adsorption-desorption, were implemented to probe the crystalline structure, molecular and electronic structure, oxygen vacancies, specific surface area (SSA) and metal loading. CO oxidation was chosen as a model reaction to explore the structure-catalytic performance relationship. A ∼100% CO conversion was achieved at < 150˚C, particularly with the CuO x /CeO 2 catalyst calcined at 700˚C. In contrast, calcination at 900˚C caused a ∼90% decrease in SSA and a ∼24% increase in T 50 . Activity tests revealed that increasing ZrO 2 content lowered CO oxidation activity despite generating more defect sites. In-situ measurement of the 700 °C calcined samples revealed the presence of stable and unstable defects in CuO x /Ce 0.5 Zr 0.5 O 2 and CeO 2 respectively, which play a key role in the activity of the catalysts. The results highlight that catalytic performance is closely related to the SSA. Furthermore, an optimum calcination temperature favor significant oxygen vacancy formation with required CuO x -support interactions, enhancing redox properties and catalytic performance.

36 MATERIALS SCIENCE↗

Real-time hybrid controls of energy storage and load shedding for integrated power and energy systems of ships

This paper presents an original energy management methodology to enhance the resilience of ship power systems. The integration of various energy storage systems (ESS), including battery energy storage systems (BESS) and super-capacitor energy storage systems (SCESS), in modern ship power systems poses challenges in designing an efficient energy management system (EMS). The EMS proposed in this paper aims to achieve multiple objectives. The primary objective is to minimize shed loads, while the secondary objective is to effectively manage different types of ESS. Considering the diverse ramp-rate characteristics of generators, SCESS, and BESS, the proposed EMS exploits these differences to determine an optimal long-term schedule for minimizing shed loads. Furthermore, the proposed EMS balances the state-of-charge (SoC) of ESS and prioritizes the SCESS’s SoC levels to ensure the efficient operation of BESS and SCESS. For better computational efficiency, we introduce the receding horizon optimization method, enabling real-time EMS implementation. Further, a comparison with the fixed horizon optimization (FHO) validates its effectiveness. Simulation studies and results demonstrate that the proposed EMS efficiently manages generators, BESS, and SCESS, ensuring system resilience under generation shortages. Additionally, the proposed methodology significantly reduces the computational burden compared to the FHO technique while maintaining acceptable resilience performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanomolar Sensitivity Chirality Transfer from Designed Helical Repeat Proteins to Achiral CdS Nanorods

Bridging chirality across length scales with inorganic− organic hybrid materials is a rapidly expanding area of research. Here, we establish asymmetry at CdS nanorod (NR) interfaces using a designed helical repeat protein bearing four cysteine residues (DHR- 4Cys). Hydrophobic NRs are transferred into water with glycine, and then glycine is displaced by DHR-4Cys, leveraging the thiophilicity of cadmium. Circular dichroism (CD) in the visible, coincident with CdS electronic transitions, reveals a chiral DHR-4Cys:CdS interface. Here, the dissymmetry factor [g-factor = 4.5 × 10 −4 (short NRs) and 5.0 × 10 −4 (long NRs)] is weakly dependent on the NR length, and CD persists at nanomolar protein loadings. Additionally, control experiments demonstrate that DHR-4Cys:CdS NR chirality is dictated by the local coordination of Cys with no significant contribution from the chiral secondary structure of the protein (g-factors of short and long Cys:CdS NRs are 4.8 × 10 −4 and 4.0 × 10 −4 , respectively). Together with far-UV CD and transmission electron microscopy, which provide evidence of preserved protein structure, these results provide the first demonstration that a structurally defined protein can induce chirality in CdS nanocrystals while maintaining protein structure at biologically relevant concentrations.

Cadmium sulfide↗

Dimolybdenum Paddlewheel Complexes with Cation Binding Sites as Electrolyte Additives to Manipulate the Solid-Electrolyte Interphase at Lithium Metal Anodes

The use of electrolyte additives at millimolar loadings to control the surface chemistry of lithium metal anodes (LMAs) is a leading strategy to improve lithium metal batteries and promote electrosynthetic reactions. Whereas previous studies employed either inorganic or organic additives, in this study, we report the first organometallic additive, Mo 2 (mea) 4 [1, mea = 2-(2-methoxyethoxy)acetate], a dimolybdenum paddlewheel complex that is stable under Li plating conditions and features cation binding sites in the second coordination sphere that promote reversible Li + coordination. Binding of Li + ions to 1 induces immobilization of cationically charged aggregates (or products thereof) into the solid electrolyte interphase (SEI), imparting multiple beneficial functions. The modified SEI was found to protect the LMA against parasitic side reactions, produce modest but measurable improvements to Li plating properties (e.g., overpotential, surface structure, and Coulombic efficiency), and improve interfacial charge transport properties. Furthermore, the most notable benefit to battery cycling performance appears in calendar aging tests, which show that the presence of the additive protects the LMA from parasitic side reactions that would otherwise decrease overall cell cycling efficiency over time. Collectively, these data disclose a tactic for designing electrolyte additives using principles of organometallic synthesis.

Additives↗

Enhancing Low-Temperature Syngas Production via Surface Tailoring of Supported Intermetallic Nanocatalysts

An active and coke-resistant silica-encapsulated intermetallic Ni 3 Zn nanoparticle catalyst was developed for low-temperature (450 °C) dry reforming of methane (DRM). The catalyst exhibited a remarkable 4-fold increase in activity (4.5 s –1 ) with over 99% CO selectivity and 3 orders of magnitude less carbonaceous species and demonstrated remarkable stability (70 h) compared to that of a monometallic Ni catalyst. Here, the key is the combined effect of surface ensemble structure and electronic interaction modulation through the surface composition tailoring achieved by off-stoichiometric Ni and Zn loading in controlling surface chemistry for achieving different activities and H 2 /CO ratios. Characterized by ion spectroscopy, X-ray photoelectron spectroscopy, and the neutron pair distribution function, it was revealed that paired Ni δ – –Zn δ+ active sites are crucial for DRM. Transient infrared spectroscopy and isotopic analysis uncovered the synergistic effect of Ni δ – –Zn δ+ sites in activating C–H bonds and dissociating CO 2 to prevent coke formation under low-temperature conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Suppressing Excessive Light Rain on Aerosol Radiative Effects and Health Risks

Global climate models (GCMs) have been used widely to study radiative forcing and health risks of aerosols. A recent study using two GCMs found that light rain plays a dominant role in controlling aerosol loading. However, “too much light rain and too little heavy rain” is a longstanding bias in GCMs. It is unclear how much light rain affects aerosol-cloud-radiation interactions and health risks from air pollution. Here, in this work, we show that, with the correction of the rainfall intensity spectrum in the National Center for Atmospheric Research Community Atmosphere Model version 5.3 by introducing a stochastic deep convection scheme, the reduced frequency of light rain (1–20 mm d -1 ) results in changes of aerosol direct radiative effects (DRE) of up to -0.5 ± 0.03 W/m 2 and aerosol cloud radiative effects (CRE) of up to -0.9 ± 0.03 W/m 2 . The total (CRE + DRE) radiative effects of light rain-mediated aerosol changes exceed the present-day anthropogenic forcing of aerosols relative to preindustrial levels from the Coupled Model Intercomparison Project (CMIP5&6) models. However, the correction of the rainfall intensity spectrum has little effect on anthropogenic aerosol forcing (defined as the radiative perturbation due to changes in aerosol concentrations between the industrial era and preindustrial levels). Due to increased exposure to fine particulates (PM 2.5 ), the estimated global total premature mortality is much higher than previously estimated, by 300,000 ± 60,000 deaths per year, and is more severe in populous regions such as India and China. The findings in this study highlight the need to understand uncertainties in radiative effects and health risks of aerosols due to simulation biases of precipitation in GCMs.

54 ENVIRONMENTAL SCIENCES↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Distributional Deep Reinforcement Learning-Based Emergency Frequency Control

Emergency frequency control is one of the most critical approaches to maintain power system stability after major disturbances. With the increasing number of grid-connected renewable energy sources, existing model-based methods of frequency control are facing up with challenges of computational speed and scalability for large-scale systems. In this paper, the emergency frequency control problem is formulated as a Markov Decision Process (MDP) and solved through a novel Distributional Deep Reinforcement Learning (DDRL) method, namely the distributional soft actor critic (DSAC) method. Compared with other RL methods that only estimate the mean value, the proposed DSAC model estimates the distribution of value function over returns. This advancement can lead to more insights and knowledge for the agent, with the benefit of a much faster and more stable learning process, and the improved frequency control performance. Here, the simulation results on IEEE 39-bus and IEEE 118-bus systems demonstrate the effectiveness and robustness of proposed models, as well as the advantage compared to other state-of-the-art DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗