Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Electric Water Heaters for Transactive Systems: Model Evaluations and Performance Quantification

Electric water heaters (EWHs) are opportune appliances for implementing demand-side control. EWH models serve as a fundamental step toward accurately estimating EWH flexibility potential and designing proper control strategies. Existing studies have adapted numerous modeling approaches in evaluating the potential of EWHs for a variety of grid applications. This paper presents an analytical study that evaluates the performance of state-of-art EWH models in terms of accuracy and computational complexity for adaptation in evaluation studies for the transactive system. The work proposes a transactive control strategy that optimally utilizes the thermal inertia of EWHs for providing grid services. Here, the performance of the control strategy and the impact of modeling accuracy is evaluated for device-level and feeder-level use cases using the IEEE 123 node test distribution system appropriately populated with EWHs. The simulation results illustrate the effectiveness of the control strategy in reducing the feeder demand during peak period by 13% and also quantities the impact of using simplified modeling approaches for determining the potential of EWHs for providing grid services.

42 ENGINEERING↗

The dynamics and control of large flexible space structures, part 11

A mathematical model is developed to predict the dynamics of the proposed Spacecraft Control Laboratory Experiment during the stationkeeping phase. The Shuttle and reflector are assumed to be rigid, while the mass connecting the Shuttle to the reflector is assumed to be flexible with elastic deformations small as compared with its length. It is seen that in the presence of gravity-gradient torques, the system assumes a new equilibrium position primarily due to the offset in the mass attachment point to the reflector from the reflector's mass center. Control is assumed to be provided through the Shuttle's three torquers and throught six actuators located by painrs at two points on the mass and at the reflector mass center. Numerical results confirm the robustness of an LQR derived control strategy during stationkeeping with maximum control efforts significantly below saturation levels. The linear regulator theory is also used to derive control laws for the linearized model of the rigidized SCOLE configuration where the mast flexibility is not included. It is seen that this same type of control strategy can be applied for the rapid single axis slewing of the SCOLE through amplitudes as large as 20 degrees. These results provide a definite trade-off between the slightly larger slewing times with the considerable reduction in over-all control effort as compared with the results of the two point boundary value problem application of Pontryagin's Maximum Principle.

Bainum, Peter M.↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results

NASA is supporting the development of Electrified Aircraft Propulsion (EAP) technology due to its potential to reduce aircraft fuel burn, emissions, and noise as well as improving safety and performance. One focus of this research is the electrification of conventional turbomachinery propulsion systems, which offers ways to improve the performance and operability of turbine-engine powered aircraft through the addition of electro-mechanical systems. These hybrid-electric turbine engines provide additional actuation and energy management control opportunities for improving stability and transient response behavior. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test performed at the NASA Electric Aircraft Testbed (NEAT) during the summer of 2022. The test demonstrates the feasibility and performance of an advanced energy management control strategy by integrating a simulated turbofan engine with scaled electro-mechanical hardware. A full-scale real-time reference model of a geared turbofan was run alongside a scaled electro-mechanical system representing the electrified turbofan components operating at a megawatt-scale power level. The model was interfaced with the hardware through a novel closed-loop control and scaling algorithm that emulated the dynamic speed and torque response of the turbofan shafts. The control strategy was implemented on the electrical machines connected to the emulated turbomachinery shafts. The results from the testbed are compared against simulations that predict the testbed and geared turbofan model operation. The energy management control strategy successfully changed the operating point of the engine model and improved its stability during throttle transients. These results also demonstrate the success of the novel closed loop control and scaling approach for emulating turbomachinery and elevate the Technology Readiness Level (TRL) of the energy management control strategy.

Aeronautics↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results

NASA is supporting the development of Electrified Aircraft Propulsion (EAP) technology due to its potential to reduce aircraft fuel burn, emissions, and noise as well as improving safety and performance. One focus of this research is the electrification of conventional turbomachinery propulsion systems, which offers ways to improve the performance and operability of turbine-engine powered aircraft through the addition of electro-mechanical systems. These hybrid-electric turbine engines provide additional actuation and energy management control opportunities for improving stability and transient response behavior. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test performed at the NASA Electric Aircraft Testbed (NEAT) during the summer of 2022. The test demonstrates the feasibility and performance of an advanced energy management control strategy by integrating a simulated turbofan engine with scaled electro-mechanical hardware. A full-scale real-time reference model of a geared turbofan was run alongside a scaled electro-mechanical system representing the electrified turbofan components operating at a megawatt-scale power level. The model was interfaced with the hardware through a novel closed-loop control and scaling algorithm that emulated the dynamic speed and torque response of the turbofan shafts. The control strategy was implemented on the electrical machines connected to the emulated turbomachinery shafts. The results from the testbed are compared against simulations that predict the testbed and geared turbofan model operation. The energy management control strategy successfully changed the operating point of the engine model and improved its stability during throttle transients. These results also demonstrate the success of the novel closed loop control and scaling approach for emulating turbomachinery and elevate the Technology Readiness Level (TRL) of the energy management control strategy.

Aeronautics↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Incorporating Residential Smart Electric Vehicle Charging in Home Energy Management Systems

Electric vehicles (EVs) are expected to drastically increase residential electricity consumption and could provide a significant source of flexible demand. Aggregating smart EV charge controllers with other smart home devices through a home energy management system can lead to more optimal outcomes that benefit homeowners, utilities, and grid operators. Control strategies should consider occupant convenience by accounting for the need for fully charged EVs near the EV departure time. In this paper, we develop an EV charging framework that accounts for occupant convenience using OCHRE, a residential energy model, and foresee, a home energy management system. We simulate a community with high EV penetration and show that integrated, smart EV charging reduces peak demand and smooths night-time energy consumption. Simulation results show that the proposed control strategy nearly eliminates peak period EV charging and reduces the daily peak demand from EVs by 23%.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Independent temperature and humidity control of a precooled desiccant air cooling system with proportional and fuzzy logic + proportional based controllers

Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.

42 ENGINEERING↗

An Adaptive Virtual Oscillator Control Structure for Grid-Forming Inverters

The electrical grid is facing unprecedented challenges due to the increasing penetration of inverter-based resources. Grid forming inverters (GFMIs) are a promising technology to address these challenges. Recently, the virtual oscillator based GFMI control is attracting more attention due to its superior performance over other control strategies. In this article, an adaptive control strategy is proposed to provide flexible operation and transition between grid-connected and islanded modes. The controller adapts the virtual oscillator's parameter values depending on the operation mode. It also provides a feedback signal using a measured frequency to account for any steady-state errors and to allow a seamless transition from grid-connected to islanded mode. Finally, to show the feasibility of the proposed controller, this article discusses the simulation results from the implementation of the controller on a single inverter system and on a group of inverters on a large practical utility feeder, the IEEE 13 node feeder, using the DIgSILENT simulation environment.

adaptive control↗

Shape control of large space structures

A survey has been conducted to determine the types of control strategies which have been proposed for controlling the vibrations in large space structures. From this survey several representative control strategies were singled out for detailed analyses. The application of these strategies to a simplified model of a large space structure has been simulated. These simulations demonstrate the implementation of the control algorithms and provide a basis for a preliminary comparison of their suitability for large space structure control.

Hagan, M. T.↗

Impact of Blockchain Delay on Grid-Tied Solar Inverter Performance

This paper investigates the impact of the delay resulting from a blockchain, a promising security measure, for a hierarchical control system of inverters connected to the grid. The blockchain communication network is designed at the secondary control layer for resilience against cyberattacks. To represent the latency in the communication channel, a model is developed based on the complexity of the blockchain framework. Taking this model into account, this work evaluates the plant’s performance subject to communication delays, introduced by the blockchain, among the hierarchical control agents. In addition, this article considers an optimal model-based control strategy that performs the system’s internal control loop. The work shows that the blockchain’s delay size influences the convergence of the power supplied by the inverter to the reference at the point of common coupling. In the results section, real-time simulations on OPAL-RT are performed to test the resilience of two parallel inverters with increasing blockchain complexity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Active Control of Rotating Stall Demonstrated for a Multistage Compressor With Inlet Distortion

Aircraft compressors can suffer debilitating consequences as a result of rotating stall and surge events caused by inlet distortions. This is particularly true of aircraft during takeoff, when the compressor is operating at peak performance close to the surge line. Significant research has been conducted by the NASA Glenn Research Center in the area of compressor stability enhancement through active and passive control methods. Most recently, an experiment was conducted at the Wright Patterson Air Force Base Research Laboratory on a two-stage fan with inlet guide vanes and inlet distortion. In this joint Small Business Innovation Research effort between Scientific Systems and Glenn, control of rotating stall was demonstrated in a multistage transonic fan. This twostage fan with inlet guide vanes was tested under clean and distorted inlet conditions. The compressor was also configured with a circumferential distortion screen capable of 180 of distortion and with 14 high-velocity injectors upstream of the first rotor. Twelve of these injectors could oscillate up to frequencies of 450 Hz. The additional two injectors were located next to each other and were used in concert with each other as a single, on/off, high-authority actuator. In a first test of injection in this multistage environment, 12 of the valves were opened 50 percent of their full stroke to assess steady injection through the compressor. This baseline injection is shown in the compressor characteristic of the following figure, and stall margin improvements are tracked from this baseline condition. The compressor was then tested with clean inlet conditions using 12 injectors and active control. Pressure disturbances were tracked before rotating stall, and a constant gain control scheme reduced the stalling mass flow by 10.8 percent over the baseline. With the distortion screen present in the inlet, a pole-zero cancellation control scheme was used to achieve a 6.4-percent decrease in stalling mass flow. These improvements also are shown in the figure. In a final experiment, actively controlled, high-frequency injection from the 12 valves was used in conjunction with the high-authority actuators. In this test, the stalling mass flow of the compressor was reduced by 27 percent as indicated in the graph. These results were obtained by injecting less than 2 percent of the total compressor throughflow into the rotor tip region via 14 injection ports. These results mark the first successful demonstration of actively controlled air injection as a stall-control strategy for multistage compressors operating at speeds typical of an actual gas turbine engine. A goal of continuing research is to determine the combination of air-injection parameters and control strategies that are most effective in providing stall control for both clean and distorted inlet flow conditions for multistage environments. Other goals include the demonstration of stall control at many locations along the core compressor and development and application of active stall control strategies that will be integral flightworthy components of onboard engine hardware.

VanSchalkwyk, Christian↗

Model-free control for frequency response support in microgrids utilizing wind turbines

Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Evaluation Functions for Fault Tolerant Multi-Rover Systems

The ability to evolve fault tolerant control strategies for large collections of agents is critical to the successful application of evolutionary strategies to domains where failures are common. Furthermore, while evolutionary algorithms have been highly successful in discovering single-agent control strategies, extending such algorithms to multiagent domains has proven to be difficult. In this paper we present a method for shaping evaluation functions for agents that provide control strategies that both are tolerant to different types of failures and lead to coordinated behavior in a multi-agent setting. This method neither relies of a centralized strategy (susceptible to single point of failures) nor a distributed strategy where each agent uses a system wide evaluation function (severe credit assignment problem). In a multi-rover problem, we show that agents using our agent-specific evaluation perform up to 500% better than agents using the system evaluation. In addition we show that agents are still able to maintain a high level of performance when up to 60% of the agents fail due to actuator, communication or controller faults.

Agogino, Adrian↗

Space shuttle flying qualities and criteria assessment

Work accomplished under a series of study tasks for the Flying Qualities and Flight Control Systems Design Criteria Experiment (OFQ) of the Shuttle Orbiter Experiments Program (OEX) is summarized. The tasks involved review of applicability of existing flying quality and flight control system specification and criteria for the Shuttle; identification of potentially crucial flying quality deficiencies; dynamic modeling of the Shuttle Orbiter pilot/vehicle system in the terminal flight phases; devising a nonintrusive experimental program for extraction and identification of vehicle dynamics, pilot control strategy, and approach and landing performance metrics, and preparation of an OEX approach to produce a data archive and optimize use of the data to develop flying qualities for future space shuttle craft in general. Analytic modeling of the Orbiter's unconventional closed-loop dynamics in landing, modeling pilot control strategies, verification of vehicle dynamics and pilot control strategy from flight data, review of various existent or proposed aircraft flying quality parameters and criteria in comparison with the unique dynamic characteristics and control aspects of the Shuttle in landing; and finally a summary of conclusions and recommendations for developing flying quality criteria and design guides for future Shuttle craft.

Myers, T. T.↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Towards a Stronger Foundation: Digitizing Commercial Buildings with Brick to Enable Portable Advanced Applications

Most large commercial buildings have digital controls for their heating, ventilation, and air-conditioning (HVAC) and lighting systems with the potential to implement advanced control strategies and data analytics. However, advanced control strategies and data analytics are rarely deployed at scale due to non-standard naming conventions and heterogenous building configurations. Semantic metadata standards, like Brick, show promise to proliferate these applications across many buildings, but they have not been widely adopted by industry due to barriers such as perceived risk and unfamiliarity with the technology. This paper describes the workflow we established and evaluated while using it to develop over ten Brick models of existing buildings. Through this process, we observed that digitizing existing commercial buildings is a cost and labor-intensive effort in which understanding the buildings’ data streams is the major bottleneck. Yet, we conclude this investment is worthwhile since various use case applications such as fault detection and diagnostics, thermal comfort analysis, and HVAC control optimization can utilize the same Brick model. The paper also explores the challenges and lessons learned we encountered while creating these data models, such as: 1) difficulties in finding metadata descriptions and relationships for existing buildings; 2) handling missing concepts in the schema needed to model a building; 3) lack of guidance on how to structure the data model or how much detail to include; 4) unfamiliarity with technologies, which makes the learning curve steep for applications developers. Finally, we also describe future directions for semantic metadata research and development to make such transformative technologies more accessible to practitioners.

Roa, Carlos Duarte↗

Simulation of traffic control signal systems

In recent years there has been considerable interest in the development and testing of control strategies for networks of urban traffic signal systems by simulation. Simulation is an inexpensive and timely method for evaluating the effect of these traffic control strategies since traffic phenomena are too complex to be defined by analytical models and since a controlled experiment may be hazardous, expensive, and slow in producing meaningful results. This paper describes the application of an urban traffic corridor program, to evaluate the effectiveness of different traffic control strategies for the Massachusetts Avenue TOPICS Project.

Connolly, P. J.↗