Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conclusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Indoor Environmental Exposures and Exacerbation of Asthma: An Update to the 2000 Review by the Institute of Medicine

Background: Previous research has found relationships between specific indoor environmental exposures and exacerbation of asthma. Objectives: In this review we provide an updated summary of knowledge from the scientific literature on indoor exposures and exacerbation of asthma. Methods: Peer-reviewed articles published from 2000 to 2013 on indoor exposures and exacerbation of asthma were identified through PubMed, from reference lists, and from authors’ files. Articles that focused on modifiable indoor exposures in relation to frequency or severity of exacerbation of asthma were selected for review. Research findings were reviewed and summarized with consideration of the strength of the evidence. Results: Sixty-nine eligible articles were included. Major changed conclusions include a causal relationship with exacerbation for indoor dampness or dampness-related agents (in children); associations with exacerbation for dampness or dampness-related agents (in adults), endotoxin, and environmental tobacco smoke (in preschool children); and limited or suggestive evidence for association with exacerbation for indoor culturable Penicillium or total fungi, nitrogen dioxide, rodents (nonoccupational), feather/down pillows (protective relative to synthetic bedding), and (regardless of specific sensitization) dust mite, cockroach, dog, and dampness-related agents. Discussion: This review, incorporating evidence reported since 2000, increases the strength of evidence linking many indoor factors to the exacerbation of asthma. Conclusions should be considered provisional until all available evidence is examined more thoroughly. Conclusion: Multiple indoor exposures, especially dampness-related agents, merit increased attention to prevent exacerbation of asthma, possibly even in nonsensitized individuals. Additional research to establish causality and evaluate interventions is needed for these and other indoor exposures.

60 APPLIED LIFE SCIENCES↗

A retrospective review of von Neumann’s analysis of hidden variables in quantum mechanics

This article reviews the history of J. von Neumann’s analysis of hidden variables in quantum mechanics and the subsequent analysis by others. In his book The Mathematical Foundations of Quantum Mechanics , published in 1932, von Neumann performed an analysis of the consequences of introducing hidden parameters (hidden variables) into quantum mechanics. He arrived at two principal conclusions: first, hidden variables cannot be incorporated into the existing theory of quantum mechanics without major modifications, and second, if they did exist, the theory would have already failed in situations where it has been successfully applied. This analysis has been taken as an “incorrect proof” against the existence of hidden variables, possibly due to a mistranslation of the German word prufen . von Neumann’s so-called proof isn’t even wrong as such a proof does not exist, but it is an examination of the limitations imposed by internal consistency of the Hilbert space formulation of the theory. One of the earliest attempts to eliminate uncertainty, by D. Bohm, requires a major modification of quantum mechanics (observables are not represented by Hermitian operators), which supports von Neumann’s first principal conclusion. However, testing the Bohm theory requires constructing a physically impossible initial state. As such, the theory has no experimental consequences, so W. Pauli referred to it as an “uncashable check”. As there are no observable consequences, the Bohm theory is possibly a counterexample to von Neumann’s second conclusion that hidden variables in particular would have already led to a failure of the theory.

density matrix↗

Deep Vadose Zone Respiration Contributions to Carbon Dioxide Fluxes from a Semiarid Floodplain

Core Ideas A significant fraction of CO 2 fluxes from a semiarid floodplain originates from below the root zone. Measured and calculated field CO 2 fluxes are consistent. Laboratory‐measured respiration rates are consistent with field results. Although CO 2 fluxes from soils are often assumed to originate within shallow soil horizons (<1‐m depth), relatively little is known about respiration rates at greater depths. We compared measured and calculated CO 2 fluxes at the Rifle floodplain along the Colorado River and measured CO 2 production rates of floodplain sediments to determine the relative importance of deeper vadose zone respiration. Calculations based on measured CO 2 gradients and estimated effective diffusion coefficients yielded fluxes that are generally consistent with measurements obtained at the soil surface (326 g C m −2 yr −1 ). Carbon dioxide production from the 2.0‐ to 3.5‐m depth interval was calculated to contribute 17% of the total floodplain respiration, with rates that were larger than some parts of the shallower vadose zone and underlying aquifer. Microbial respiration rates determined from laboratory incubation tests of the sediments support this conclusion. The deeper unsaturated zone typically maintains intermediate water and air saturations, lacks extreme temperatures and salinities, and is annually resupplied with organic carbon from snowmelt‐driven recharge and by water table decline. This combination of favorable conditions supports deeper unsaturated zone microbial respiration throughout the year.

Tokunaga, Tetsu K.↗

SINGLE-SHELL TANK INTEGRITY PROJECT ANALYSIS OF RECORD-PRELIMINARY MODELING PLAN FOR THERMAL AND OPERATING LOADS

This document is a Phase I deliverable for the Single-Shell Tank Analysis of Record effort. This document is not the Analysis of Record. The intent of this document is to guide the Phase II detailed modeling effort. Preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. The preliminary analysis document reviews and preliminary modeling analysis results are reported herein. In addition, this report provides recommendations for the next phase of the SST AOR project, SST detailed modeling. Efforts and results discussed in this report do not include seismic modeling as seismic modeling is covered by a separate report. The combined results of both static and seismic models are required to complete this effort. The SST AOR project supports the US Department of Energy's (DOE) Office of River Protection (ORP) mission for obtaining a better understanding of the structural integrity of Hanford's SSTs. The 149 SSTs, with six different geometries, have experienced a range of operating histories which would require a large number of unique analyses to fully characterize their individual structural integrity. Preliminary modeling evaluations were conducted to determine the number of analyses required for adequate bounding of each of the SST tank types in the Detailed Modeling Phase of the SST AOR Project. The preliminary modeling was conducted in conjunction with the Evaluation Criteria report, Johnson et al. (2010). Reviews of existing documents were conducted at the initial stage of preliminary modeling. These reviews guided the topics that were explored in the SST preliminary modeling. The reviews determined the level of detail necessary to perform the analyses of the SSTs. To guide the Phase II detailed modeling effort, preliminary finite element models for each of the tank types were developed and different case studies were performed on one or more of these tank types. Case studies evaluated include thermal loading, waste level variation, the sensitivity of boundary effects (soil radial extent), excavation slope or run to rise ratio, soil stratigraphic (property and layer thickness) variation at different farm locations, and concrete material property variation and their degradation under thermal loads. Conclusions were derived from case studies on one of the tank types when no additional runs of similar cases on other types of tanks were found necessary to derive those conclusions. The document reviews provided relatively complete temperature histories for Type IV tanks. The temperature history data for Type I, II, and III tanks was almost nonexistent for years prior to 1975. Document reviews indicate that there might be additional useful data in the US Department of Energy, Richland Operations Office (DOE-RL) records in Seattle, WA, and these records need to be reviewed to extract data that might have been disregarded during previous reviews. Thermal stress analyses were conducted using different temperature distribution scenarios on Type IV tanks. Such studies could not be carried out for other tank types due to lack of temperature history data. The results from Type IV tank analyses indicate that factors such as temperature distribution in the tank waste and rate of rise in waste temperature have a significant impact on the thermal stresses in the tank structures. Overall, the conclusion that can drawn from the thermal stress analyses is that these studies should be carried out for all tank types during the detailed analysis phase with temperature values that are reasonably close to the typical temperature histories of the respective tank types. If and/or when additional waste temperature data is acquired for tank Type I, II, and III tanks, additional cases need to be considered as tank structural integrity is sensitive to thermal loads. A few case studies were also performed using Type IV-b models to comprehend the effects of excavation boundaries, change in soil stratigraphy (layer thickness and properties), and radial extent of soil in the finite element models. The result from the case studies indicates that the slight variation in soil stratigraphy has little effects on the tank sections force and moment demands under mechanical loads. The case study for excavation slope or backfill transition boundary indicated that inclusion of such boundary yields conservative demands in the wall region while demands at other locations remain unaffected. Hence this excavation slope will be modeled in the detailed analysis of SSTs.

54 ENVIRONMENTAL SCIENCES↗

Comparison of the PLTEMP code flow instability predictions with measurements made with electrically heated channels for the advanced test reactor.

When the University of Missouri Research Reactor (MURR) was designed in the 1960s the potential for fuel element burnout by a phenomenon referred to at that time as 'autocatalytic vapor binding' was of serious concern. This type of burnout was observed to occur at power levels considerably lower than those that were known to cause critical heat flux. The conversion of the MURR from HEU fuel to LEU fuel will probably require significant design changes, such as changes in coolant channel thicknesses, that could affect the thermal-hydraulic behavior of the reactor core. Therefore, the redesign of the MURR to accommodate an LEU core must address the same issues of fuel element burnout that were of concern in the 1960s. The Advanced Test Reactor (ATR) was designed at about the same time as the MURR and had similar concerns with regard to fuel element burnout. These concerns were addressed in the ATR by two groups of thermal-hydraulic tests that employed electrically heated simulated fuel channels. The Croft (1964), Reference 1, tests were performed at ANL. The Waters (1966), Reference 2, tests were performed at Hanford Laboratories in Richland Washington. Since fuel element surface temperatures rise rapidly as burnout conditions are approached, channel surface temperatures were carefully monitored in these experiments. For self-protection, the experimental facilities were designed to cut off the electric power when rapidly increasing surface temperatures were detected. In both the ATR reactor and in the tests with electrically heated channels, the heated length of the fuel plate was 48 inches, which is about twice that of the MURR. Whittle and Forgan (1967) independently conducted tests with electrically heated rectangular channels that were similar to the tests by Croft and by Walters. In the Whittle and Forgan tests the heated length of the channel varied among the tests and was between 16 and 24 inches. Both Waters and Whittle and Forgan show that the cause of the fuel element burnout is due to a form of flow instability. Whittle and Forgan provide a formula that predicts when this flow instability will occur. This formula is included in the PLTEMP/ANL code.Error! Reference source not found. Olson has shown that the PLTEMP/ANL code accurately predicts the powers at which flow instability occurs in the Whittle and Forgan experiments. He also considered the electrically heated tests performed in the ANS Thermal-Hydraulic Test Loop at ORNL and report by M. Siman-Tov et al. The purpose of this memorandum is to demonstrate that the PLTEMP/ANL code accurately predicts the Croft and the Waters tests. This demonstration should provide sufficient confidence that the PLTEMP/ANL code can adequately predict the onset of flow instability for the converted MURR. The MURR core uses light water as a coolant, has a 24-inch active fuel length, downward flow in the core, and an average core velocity of about 7 m/s. The inlet temperature is about 50 C and the peak outlet is about 20 C higher than the inlet for reactor operation at 10 MW. The core pressures range from about 4 to about 5 bar. The peak heat flux is about 110 W/cm{sup 2}. Section 2 describes the mechanism that causes flow instability. Section 3 describes the Whittle and Forgan formula for flow instability. Section 4 briefly describes both the Croft and the Waters experiments. Section 5 describes the PLTEMP/ANL models. Section 6 compares the PLTEMP/ANL predictions based on the Whittle and Forgan formula with the Croft measurements. Section 7 does the same for the Waters measurements. Section 8 provides the range of parameters for the Whittle and Forgan tests. Section 9 discusses the results and provides conclusions. In conclusion, although there is no single test that by itself closely matches the limiting conditions in the MURR, the preponderance of measured data and the ability of the Whittle and Forgan correlation, as implemented in PLTEMP/ANL, to predict the onset of flow instability for these tests leads one to the conclusion that the same method should be able to predict the onset of flow instability in the MURR reasonably well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada National Security Site, Nye County, Nevada: Review of the Performance Assessments and Composite Analyses (2012 Annual Summary Report)

The Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site (National Security Technologies, LLC 2007a) requires an annual review to assess the adequacy of the performance assessments (PAs) and composite analyses (CAs), with the results submitted to the U.S. Department of Energy (DOE) Office of Environmental Management. The Disposal Authorization Statements for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) also require that such reviews be made and that secondary or minor unresolved issues be tracked and addressed as part of the maintenance plan (DOE 1999a, 2000). The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office performed an annual review of the Area 3 and Area 5 RWMS PAs and CAs for fiscal year (FY) 2012. This annual summary report presents data and conclusions from the FY 2012 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (RD) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada National Security Site (NNSS) relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and RD activities were reviewed to determine the adequacy of the CAs. Important developments in FY 2012 include the following: Release of a special analysis for the Area 3 RWMS assessing the continuing validity of the PA and CA; Development of a new Area 5 RWMS closure inventory estimate based on disposals through FY 2012; Evaluation of new or revised waste streams by special analysis; and Development of version 4.114 of the Area 5 RWMS GoldSim PA model. The Area 3 RWMS has been in inactive status since July 1, 2006, with the last shipment received in April 2006. The FY 2012 review of operations, facility design, closure plans, monitoring results, and RD results for the Area 3 RWMS indicates no changes that would impact PA validity. A special analysis using the Area 3 RWMS v2.102 GoldSim PA model was prepared to update the PA results for the Area 3 RWMS in FY 2012. The special analysis concludes that all performance objectives can be met and the Area 3 RWMS PA remains valid. There is no need to the revise the Area 3 RWMS PA. Review of Area 5 RWMS operations, design, closure plans, monitoring results, and RD activities indicates no significant changes other than an increase in the inventory disposed. The FY 2012 PA results, generated with the Area 5 RWMS v4.114 GoldSim PA model, indicate that there continues to be a reasonable expectation of meeting all performance objectives. The results and conclusions of the Area 5 RWMS PA are judged valid, and there is no need to the revise the PA. A review of changes potentially impacting the CAs indicates that no significant changes occurred in FY 2012. The continuing adequacy of the CAs was evaluated with the new models, and no significant changes that would alter CA results or conclusions were found. The revision of the Area 3 RWMS CA, which will include the Underground Test Area source term (Corrective Action Unit [CAU] 97), is scheduled for FY 2024, following the completion of the Yucca Flat CAU 97 Corrective Action Decision Document/Corrective Action Plan in FY 2016. Inclusion of the Frenchman Flat CAU 98 results in the Area 5 RWMS CA is scheduled for FY 2016, pending the completion of the CAU 98 closure report in FY 2015. Near-term RD efforts will focus on continuing development of the Area 3 and Area 5 RWMS GoldSim PA/CA and inventory models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TMI-2 – A Case Study for PWR Instrumentation Performance During a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focussed upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Independent Review of AFC 2A, 2B, and 2E ATR Irradiation Tests

As part of the Department of Energy Advanced Fuel Cycle program, a series of fuels development irradiation tests have been performed in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. These tests are providing excellent data for advanced fuels development. The program is focused on the transmutation of higher actinides which best can be accomplished in a sodium-cooled fast reactor. Because a fast test reactor is no longer available in the US, a special test vehicle is used to achieve near-prototypic fast reactor conditions (neutron spectra and temperature) for use in ATR (a water-cooled thermal reactor). As part of the testing program, there were many successful tests of advanced fuels including metals and ceramics. Recently however, there have been three experimental campaigns using metal fuels that experienced failure during irradiation. At the request of the program, an independent review committee was convened to review the post-test analyses performed by the fuels development team, to assess the conclusions of the team for the cause of the failures, to assess the adequacy and completeness of the analyses, to identify issues that were missed, and to make recommendations for improvements in the design and operation of future tests. Although there is some difference of opinion, the review committee largely agreed with the conclusions of the fuel development team regarding the cause of the failures. For the most part, the analyses that support the conclusions are sufficient.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TMI-2 - A Case Study for PWR Instrumentation Performance during a Severe Accident

The accident at the Three Mile Island Unit 2 (TMI-2) reactor provided a unique opportunity to evaluate sensors exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during this accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. As part of a program initiated in 2012 by the Department of Energy Office of Nuclear Energy (DOE-NE), a review was completed to gain insights from prior TMI-2 sensor survivability and data qualification efforts. This new effort focused upon a set of sensors that provided critical data to TMI-2 operators for assessing the condition of the plant and the effects of mitigating actions taken by these operators. In addition, the effort considered sensors providing data required for subsequent accident simulations. Over 100 references related to instrumentation performance and post-accident evaluations of TMI-2 sensors and measurements were reviewed. Insights gained from this review are summarized within this report. For each sensor, a description is provided with the measured data and conclusions related to the sensor’s survivability, and the basis for conclusions about its survivability. As noted within this document, several techniques were invoked in the TMI-2 post-accident evaluation program to assess sensor status, including comparisons with data from other sensors, analytical calculations, laboratory testing, and comparisons with sensors subjected to similar conditions in large-scale integral tests and with sensors that were similar in design but more easily removed from the TMI-2 plant for evaluations. Conclusions from this review provide important insights related to sensor survivability and enhancement options for improving sensor performance. In addition, this document provides recommendations related to the sensor survivability and data evaluation process that could be implemented in upcoming Fukushima Daiichi recovery efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An evaluation of the carbon sequestration potential of the Cambro-Ordovician Strata of the Illinois and Michigan basins

The studies summarized herein were conducted during 2009–2014 to investigate the utility of the Knox Group and St. Peter Sandstone deeply buried geologic strata for underground storage of carbon dioxide (CO 2 ), a practice called CO 2 sequestration (CCS). In the subsurface of the midwestern United States, the Knox and associated strata extend continuously over an area approaching 500,000 sq. km, about three times as large as the State of Illinois. Although parts of this region are underlain by the deeper Mt. Simon Sandstone, which has been proven by other Department of Energy-funded research as a resource for CCS, the Knox strata may be an additional CCS resource for some parts of the Midwest and may be the sole geologic storage (GS) resource for other parts. One group of studies assembles, analyzes, and presents regional-scale and point-scale geologic information that bears on the suitability of the geologic formations of the Knox for a CCS project. New geologic and geo-engineering information was developed through a small-scale test of CO 2 injection into a part of the Knox, conducted in western Kentucky. These studies and tests establish the expectation that, at least in some locations, geologic formations within the Knox will (a) accept a commercial-scale flow rate of CO 2 injected through a drilled well; (b) hold a commercial-scale mass of CO 2 (at least 30 million tons) that is injected over decades; and (c) seal the injected CO 2 within the injection formations for hundreds to thousands of years. In CCS literature, these three key CCS-related attributes are called injectivity, capacity, and containment. The regional-scale studies show that reservoir and seal properties adequate for commercial-scale CCS in a Knox reservoir are likely to extend generally throughout the Illinois and Michigan Basins. Information distinguishing less prospective subregions from more prospective fairways is included in this report. Another group of studies report the results of reservoir flow simulations that estimate the progress and outcomes of hypothetical CCS projects carried out within the Knox (particularly within the Potosi Dolomite subunit, which, in places, is highly permeable) and within the overlying St. Peter Sandstone. In these studies, the regional-scale information and a limited amount of detailed data from specific boreholes is used as the basis for modeling the CO 2 injection process (dynamic modeling). The simulation studies were conducted progressively, with each successive study designed to refine the conclusions of the preceding one or to answer additional questions. The simulation studies conclude that at Decatur, Illinois or a geologically similar site, the Potosi Dolomite reservoir may provide adequate injectivity and capacity for commercial-scale injection through a single injection well. This conclusion depends on inferences from seismic-data attributes that certain highly permeable horizons observed in the wells represent laterally persistent, porous vuggy zones that are vertically more common than initially evident from wellbore data. Lateral persistence of vuggy zones is supported by isotopic evidence that the conditions that caused vug development (near-surface processes) were of regional rather than local scale. Other studies address aspects of executing and managing a CCS project that targets a Knox reservoir. These studies cover well drilling, public interactions, representation of datasets and conclusions using geographic information system (GIS) platforms, and risk management.

54 ENVIRONMENTAL SCIENCES↗

Final Report. Grant DOE DE-FG02-04ER54768

The magnetized spherical implosion campaign funded by this grant is summarized in this progress report. The main goal of this grant was to improve the seed eld generator MIFEDS (Magneto- Inertial Fusion Energy Delivery System) on the OMEGA laser to enable experiments at high elds (> 8 T) and to carry out magnetized spherical implosion experiments to study the e ect of magnetic elds on the fusion yield. New experiments were carried out in the last budget period to study the e ect of higher elds and shaped laser pulses. These new experiments improved the magnetized implosion database and allowed us to improve the con dence of our conclusions with respect to the e ect of magnetic elds on implosion performance. The main conclusion is that adding magnetic eld leads to a 30% higher neutron yield, but using seed magnetic eld higher than 8 T does not further increase the neutron yield. A further conclusion is that the yield enhancement due to the magnetic eld is approximately independent of the laser pulse shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discriminating Tailing Piles using VNIR Imagery and SVMs

This report describes a brief investigation into the use of multispectral satellite imagery and a machine learning technique to discriminate between the soils in two tailing piles in the U1a Complex at the Nevada National Security Site. The south pile dates from the late 1960s and the north pile dates from the early 2000s and is where recent tailings have been dumped. Our approach is to use commercially available satellite imagery of the U1a tailing piles and a Support Vector Machine (SVM) to discriminate between the soils in these piles. Experiments were performed using multispectral pixels selected from around the U1a Complex to train the support vector machine. Pixels in the scene were then classified by the SVM. Classification performance was assessed qualitatively through study of the classification imagery output by the SVM. These qualitative assessments provide the conclusions drawn by the investigation: 1. A SVM can be used to discriminate between different types of materials in satellite imagery. 2. The VNIR imagery used in this investigation does not provide the features needed by the SVM to discriminate between the two tailing piles at the U1a Complex-the soils look too similar in these spectral bands to discriminate. The remainder of the report details the experiments performed to reach these conclusions and the limitations and caveats associated with the conclusions.

97 MATHEMATICS AND COMPUTING↗

Coincidence of the Measured Voltage Peak and the Measured Current Inflection Point in Exploding Metals

Exploding Bridgewire (EBW) Detonators and Exploding Foil Initiators (EFI's, e.g. Slappers) have unique current and voltage characteristics marked by a large voltage spike and an inflection point in the current. Mathematically, it is shown that the voltage peak and the current inflection point must align in time. Models concur with the math and show voltage peaks occurring at the same point in time as the inflection point. Circuit analysis is performed to demonstrate why the voltage peak and current inflection point will almost never align in time for an experiment. To correctly analyze exploding metal behavior, the current inflection point and voltage peak must be manually aligned in time. These conclusions apply to single detonators where current and voltage is measured on those detonators. In multi-detonator systems, the conclusions herein apply only for cases where current and voltage are obtained for each detonator individually. The conclusions will begin to break down as measurements become combined.

36 MATERIALS SCIENCE↗

HFTS-2 (Final Report)

This report delves into the research program, identified tasks, various studies, observations, results, and conclusions under the Hydraulic Fracturing Test Site (HFTS-2) project. This test site is located in Loving County close to the Texas, New Mexico border. The program targeted the Wolfcamp formation in Delaware Basin. The aim of the project was to improve our understanding of hydraulic fracturing processes to not only optimize unconventional resource development in US Basins but to minimize environmental footprint as well. Various new diagnostic technologies were demonstrated at this site, including distributed acoustic microseismic, high resolution strain using Rayleigh frequency band (DSS-RFS), and in-fill proppant logging tool. Significant conclusions from this study include: 1) lateral and vertical fracture growth mapping as well as proppant transport behavior, 2) Use of DSS-RFS as a diagnostic tool to understand cluster level behavior, 3) Validation of proppant log, both at core scale as well as in-fill well implementation, and 4) New modeling tools to map far-field strain response using distributed strain sensing data. Specifically, far-field fracture distribution is influenced by linear fracture corridors defined by the stress-state as well as clustering behavior influenced by spatio-temporal effects. Depletion impacts on new stimulation was demonstrated and technically quantified. Significant vertical fracture height growth was observed. However, our understanding is limited by available gauge data availability. Numerical strain modeling techniques have been developed and demonstrated to help understand observed strain response behavior. Finally, proppant log has been further validated as a useful tool to map propped zones within the SRV. It has also shown very strong correlation with observed drawdown behavior at this test site. This report will detail many of these studies as well as technical results and conclusions from said studies. These include general subsurface characterization work, completion designs as implemented, studies looking at fracture geometry, high resolution microseismic study including source mechanisms, advanced DSS-RFS studies including drainage characterization, core characterization results, proppant analysis (core and in-fill child well), geochemistry, etc.

02 PETROLEUM↗

Application of Principal Component Analysis to Electrochemical Reprocessing PM and NMAC

In this report, data from an electrorefiner (ER) for nuclear fuel reprocessing is evaluated for process monitoring (PM) conclusions. This data comes from tests performed at the Idaho National Laboratory in 2022. Multivariate approaches utilizing methods of Principal Component Analysis (PCA) is applied. This is based off established work in process monitoring for fault detection in industrial facilities. This report will discuss the background, methods, and results of the application and some of the conclusions and applications that can be drawn from them. PCA is applied to two different electrorefiner (ER) operations that occurred at Idaho National Laboratory between August and October 2022. The first operation occurred with little incident while the second had several noted faults in the equipment in operational logs. The data from the first run was used to train the data for “normal” operations and applied to both sets of data to determine when operations were in an “off-normal” condition and identify where the fault occurs through PCA. PCA was able to identify off-normal events and identify the cause for off-normal operations. These identified off-normal events matched with the events and their causes in the operational logs. However, small amounts of variance in the data led to false detection of “off-normal” events. Thus, careful selection of training data and a-posteriori conclusions based off operator assessments will both be required for application of PCA to PM applications. This work demonstrated that multivariate approaches and latent variables are applicable to pyroprocessing PM applications and can be further expanded in future work as quality variables such as salt concentration from sensors and sampling become available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HFTS-1 (Final Report)

Despite the long history of hydraulic fracturing, the optimal number of fracturing stages during multi-stage fracture stimulation in horizontal wells can be a complex subject. In addition to the increased expense of multistage fracturing in horizontal wells, increasing the number of fracturing stages does not always correlate with a commensurate increase in production. The problem is the application of a uniform fracture stimulation design to all stages with no consideration for geological variations along the wellbore. The result is an inefficient use and costly waste of energy and water. Optimization of the fracturing process requires an understanding of the cause-and-effect relationship between fracturing parameters and local geological properties at a given location along the wellbore. Realizing that the generalized rock mechanics theories and hypotheses are not truly applicable to fractured and laminated shales, quantifiable impacts of a shale’s geomechanical and depositional features are a prerequisite for design and implementation of optimized hydraulic fractures. The overarching goal of this project is to understand and define the relationships of shale geology and fracture dynamics using detailed field data that includes coring of the fracture domain. Finally, resource recovery from shale formations is estimated to be less than fifteen percent. Research proposed in this project will establish the foundations for investigating enhanced recovery techniques for increased resource recovery in existing fracture treated wells. Natural gas as an EOR fluid is in the initial stages of being used broadly in the oil and gas industry and as such, many aspects of the process need to be researched and addressed prior to widespread acceptance. In addition, re-fracturing techniques, particularly using cemented liners also need to be further investigated. This project explores several of these EOR techniques in greater detail, not just at the theoretical level, but through actual field test sites. This report delves into the research program, identified tasks, several studies, observations, results, and conclusions under the Hydraulic Fracturing Test Site (HFTS) project. This test project is subdivided into three distinct phases and each phase is discussed in detail under separate sections. The original test site for Phase 1 as well as the Phase 2 site are in Midland Basin in Texas and operated by Laredo Petroleum. In the first two phases, the program targeted the Wolfcamp formation in Midland Basin. Phase 3 of the study targeted the EagleFord play in South Texas with Devon Energy as the operator. Significant conclusions from this study include: 1) lateral and vertical fracture growth mapping as well as proppant transport behavior, 2) Use of field gas and its applicability for huff n puff EOR injection in the Midland Basin, 3) Development and validation of proppant log, both at core scale as well as in-fill well implementation by analyzing drilling mud return samples, 4) Applicability of liner refracturing including best practices for enhanced unit level productivity. This report will detail all these studies as well as technical results and conclusions from said studies. These include general subsurface characterization work, completion designs as implemented, studies looking at fracture geometry, high resolution microseismic study, advanced crosswell strain mapping studies including drainage characterization, core characterization results, proppant analysis (core and observation wells), geochemistry, etc. to name a few.

02 PETROLEUM↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

The riddle of the redshifts

Somewhat more than 40 years ago Hubble and Humason conclusively established that the redshifts of the galaxies are proportional to their apparent brightnesses. With this discovery came the general conclusion that the redshifts were due to the Doppler effect and that the universe is expanding. The discovery of QSOs with large redshifts led to the conclusion that if the redshifts were measures of distance the objects were at immense distances and in general some 50 times brighter than most luminous galaxies. Arguments for and against the cosmological redshift hypothesis are evaluated, giving attention to QSO variability, questions of relativistic expansion, the redshift-apparent magnitude diagram, the redshift-angular diameter relation, the distribution of redshifts, multiple redshifts, and distance measurements in extragalactic astronomy.

Burbidge, G.↗