Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherent x-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

Structural Mechanism of an Efficacy Photoswitch Targeting the β 2 ‐adrenergic Receptor

The field of photopharmacology develops light-responsive drugs that can modulate protein activity, enabling precise and dynamic investigations of their roles in health and disease. Adrenergic receptors are prominent targets for this approach because they are prototypical G protein-coupled receptors with high clinical relevance in bronchial and cardiovascular diseases. Here, we employed the azobenzene-based compound photoazolol-1 in combination with time-resolved serial crystallography at X-ray free-electron lasers to resolve the molecular mechanisms by which photoswitchable β-blockers modulate activity of the β 2 -adrenoceptor (β 2 AR). Time-resolved structures of the receptor bound to trans-photoazolol-1 (pre-photoconversion), a strained intermediate in the nanosecond range, and the fully photoisomerized cis-photoazolol-1 reveal how isomerization of the azobenzene moiety induces distinct conformational changes within the orthosteric ligand binding pocket. Within seconds, light-excited photoazolol-1 adopts a new binding pose, altering interactions with extracellular loop 2 and shifting the positions of transmembrane helices 5, 6, and 7. Functional assays of β 2 AR in cellular membranes show that photoazolol-1 acts as an efficacy photoswitch, changing from an inverse agonist to a neutral antagonist upon isomerization without leaving the binding pocket. In combination, these findings suggest a molecular mechanism for activity modulation via efficacy photoswitches and provide a framework for designing ligands that exploit light-driven transitions within the binding pocket to achieve spatiotemporal control of receptor function.

G protein-coupled receptors↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Shake-Down Spectroscopy as State- and Site-Specific Probe of Ultrafast Chemical Dynamics

Tracking the multifarious ultrafast electronic and structural changes occurring in a molecule during a photochemical transformation is a challenging endeavor that benefits from recent experimental and computational progress in time-resolved techniques. Measurements of valence electronic states, which provide a global picture of the bonding structure of the molecule, and core electronic states, which provide insight into the local environment, traditionally require different approaches and are often studied separately. Here, we demonstrate that X-ray pulses from a seeded free-electron laser (FEL) enable the measurement of high-resolution, time-resolved X-ray photoelectron spectra (XPS) that capture weak satellite states resulting from shake-down processes in a valence-excited molecule. This approach effectively combines the advantages of both valence- and core-state investigations. We applied this method to investigate photoexcited CS2 molecules, where the role of internal conversion (IC) and intersystem crossing (ISC) in determining the predissociation dynamics is controversial. We present XPS spectra from photoexcited CS2, obtained at the FERMI FEL. High-resolution measurements, compared to the corresponding spectra obtained from accurate multireference quantum chemical calculations, reveal that shake-down satellite channels are highly sensitive to both valence electronic and geometric changes. Previous studies of the predissociation dynamics have led to uncertain assignments of the branching between singlet and triplet excited states. We derive a propensity rule that demonstrates the spin-selectivity of the shake-downs. This selectivity allows us to unequivocally assign contributions from the bright and dark singlet excited states, with populations tracked along the predissociation dynamic pathway.

Thompson, Henry J. [Univ. of Southampton (United K↗

Epitaxial strain tuning of Er 3+ in ferroelectric thin films

Er 3+ color centers are promising candidates for quantum science and technology due to their long electron and nuclear spin coherence times, as well as their desirable emission wavelength. By selecting host materials with suitable, controllable properties, we introduce new parameters that can be used to tailor the Er 3+ emission spectrum. PbTiO 3 is a well-studied ferroelectric material with known methods of engineering different domain configurations through epitaxial strain. By distorting the structure of Er 3+ -doped PbTiO 3 thin films, we can manipulate the crystal fields around the Er 3+ dopant. This is resolved through changes in the Er 3+ resonant fluorescence spectra, tying the optical properties of the defect directly to the domain configurations of the ferroelectic matrix. Additionally, we are able to resolve a second set of peaks for films with in-plane ferroelectric polarization. We hypothesize these results to be due to either the Er 3+ substituting different sites of the PbTiO 3 crystal, differences in charges between the Er 3+ dopant and the original substituent ion, or selection rules. Systematically studying the relationship between the Er 3+ emission and the epitaxial strain of the ferroelectric matrix lays the pathway for future optical studies of spin manipulation by altering ferroelectric order parameters.

36 MATERIALS SCIENCE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Excited State Covalency, Dynamics, and Photochemistry of Square Planar Ni-Thiolate Complexes Revealed by Ultrafast X-ray Absorption

Highly covalent Ni bis(dithiolene) and related complexes provide an ideal platform for investigating the effects of metal–ligand orbital hybridization on excited state character and dynamics. In particular, we focus on the ligand field excited states that dominate the photophysics of first-row transition metal complexes. Here, we investigate if they can be significantly delocalized off the metal center, possibly yielding photochemical reactivity more similar to charge transfer excited states than metal-centered ligand field excited states. Here [Ni(mpo) 2 ] (mpo = 2-mercaptopyridine- N-oxide) provides a representative example for the larger chemical class and is an active electro- and photo-catalyst for proton reduction. A detailed characterization of the excited state electronic structure, dynamics, and photochemistry of [Ni(mpo) 2 ] is presented based on ultrafast transient X- ray absorption spectroscopy at the Ni and S 1s core absorption K-edges. By comparing the ultrafast Ni K-edge absorption to ab initio calculations, we identify an excited state relaxation mechanism where an initial ligand-to-metal charge transfer excitation results in both excited state electron transfer (generating a catalytically relevant reduced photoproduct [Ni(mpo) 2 ] − ) and relaxation to a pseudo-tetrahedral triplet ligand field excited state. From the ultrafast S K-edge absorption, the ligand field excited state is found to be highly delocalized onto the thiolate ligands and a tetrahedral structural distortion is shown to substantially influence the degree of delocalization. The results identify a significant structural coordinate to target when aiming to control the excited state covalency in square planar complexes.

Lim, Hyeongtaek [SLAC National Accelerator Laborat↗

Strain-induced topological transitions in epitaxial films of cadmium arsenide

Strain in epitaxial thin films can have a profound influence on their electronic bands. Here, we investigate the influence of epitaxial strains on the electronic states of (001)-oriented cadmium arsenide (Cd 3 As 2 ) thin films, which are two-dimensional topological insulators. Cd 3 As 2 films were grown coherently on Al 1−x In x Sb buffer layers with varying degrees of lattice mismatch to Cd 3 As 2 , producing in-plane stresses that ranged from compressive to tensile. Using magneto-transport measurements of the Landau levels of the lowest subbands, we show that films under compression remain in the two-dimensional topological insulator state, while a sufficiently large tensile stress induces a transition to a topologically trivial phase. These results qualitatively agree with expectations from theoretical models for these films. At the topological transition, the gap avoids completely closing, and we discuss possible origins.

36 MATERIALS SCIENCE↗

Lunar accelerometer network gravitational observatory (LANGO)

With ground-based interferometers detecting hundreds of gravitational-wave (GW) events, GW astronomy has continued to blossom. U.S. and European scientists are developing plans to construct third-generation ground-based interferometers. ESA has proceeded through the mission formulation phase of space-based interferometer in a lower-frequency band, 10 –4 –0.1 Hz. Despite all these exciting developments, there is still a missing frequency band, 0.1–10 Hz. This mid-frequency band is rich with interesting astrophysical events. Coalescence and merger of intermediate-mass black holes (IMBHs) will occur in this frequency band. Coalescing stellar-mass BHs will pass through this frequency band days before they reach the frequency band of LIGO and Virgo. Detection of such signals would enable a mid-frequency detector to issue an advance notice to the high-frequency GW detectors, as well as to optical, x-ray and γ-ray telescopes. We propose Lunar Accelerometer Network Gravitational Observatory (LANGO) to detect GWs in this frequency band. In the first phase (LANGO 1), we propose to deploy four ambient-temperature (250 K) accelerometers in the tetrahedral or in a square configuration on the hemisphere facing the Earth. After successful operation at 250 K, LANGO would be upgraded to a cryogenic (4 K) version with over two orders of magnitude increased sensitivity (LANGO 2), with coherent rejection of seismic noise implemented. LANGO is a full-tensor detector, capable of determining the source direction and wave polarization. Each test mass (TM) is suspended as a pendulum with resonance frequency ∼ 0.01 Hz, thus is only weakly coupled to the lunar surface horizontally. LANGO is designed to detect the relative motion of globally separated, nearly free, TMs by using the Moon as a large quiet platform. LANGO 1 and 2 accelerometers aim at sensitivities ⩽ 10 –11 m s –2 Hz –1/2 and ⩽ 10 –13 m s –2 Hz –1/2 in the horizontal axes over the frequency band of 1 mHz–10 Hz, which yield GW sensitivities 1.1 x 10 -21 Hz -1/2 and 3.8 x 10 -24 Hz -1/2 at 1 Hz, respectively. The LANGO accelerometers will be 10 3 –10 5 times more sensitive than Apollo seismometers. With such sensitivity, LANGO will also make great contribution to the advancement of lunar geophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Static and dynamic topological defects in the domain textures in the helical antiferromagnet Ni 2 ⁢CoTeO 6

Real-space Bragg coherent x-ray-diffractive imaging unveils the formation of bubble and stripe antiferromagnetic (AFM) phase domains on the surface of Ni 2 ⁢CoTeO 6 single crystal. The stripe domains exhibit dislocation-type topological defects. The defects typically form as defect-antidefect pairs and can be created or annihilated by temperature changes and local heating. Thermal fluctuations of the AFM domain walls are observed near the Néel temperature. Topological defect pairs dynamically form and disappear in the fluctuating state. These observations provide a real-space perspective on the dynamics of the AFM phase transition in a helical antiferromagnet. Finally, the remarkable tunability of AFM domain walls in a helical antiferromagnet underscores their potential for AFM spintronics applications.

36 MATERIALS SCIENCE↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Einstein SSS and MPC observations of Aql X-1 and 4U1820-30

The results of timing and spectral analyses of the X-ray sources Aql X-1 (X1908+005) and 4U1820-30 (NGC6624) are reported using data obtained with the Einstein SSS (Solid State Spectrometer) and MPC (Monitor Proportional Counter) instruments. A classic type I burst was observed from Aql X-1 in both detectors and a coherent modulation with a period of 131.66 + or - 0.02 ms and a pulsed fraction of 10 percent was detected in the SSS data. There is no evidence for a loss of coherance during the approximately 80 sec when the burst is observable. The 2 sigma upper limit on the rate of change of the pulse period is 0.00005s/s. It is argued that an asymmetrical burst occurring on a neutron star rotating at 7.6 Hz offers a plausible explanation for the oscillation. The data from 4U1820-30 show that the amplitude of the 685 sec modulation, identified as the orbital period, is independent of energy down to 0.6 keV. The SSS data show that the light curve in the 0.6 to 4.5 keV band is smoother than at higher energies.

Kelley, R. L.↗

Detection of coherent 7.6 Hz oscillations during a burst from Aquila X-1

The results are reported of timing and spectral analysis of the X-ray source Aql X-1 (X1908 + 005) using data obtained with the Einstein SSS and MPC instruments. A classic type I burst was observed from Aql X-1 in both detectors, and a coherent modulation with a period of 131.66 + or - 0.02 (7.6 Hz) and a pulsed fraction of 10 percent was detected in the SSS data (0.64-4.5 keV) during the period of enhanced emission. The signal has a random occurrence probability of less than 5 x 10 to the -5th. The sensitivity of the MPC for high-resolution timing during the burst is greatly reduced because of the low-duty cycle during the burst, and the modulation is not detected. There is no evidence for a loss of coherence during the 80 s or so when it is observable. It is argued that an asymmetrical burst occurring on a neutron star rotating at 7.6 Hz offers a plausible explanation for the oscillation.

Schoelkopf, R. J.↗

A search for fast gamma-ray pulsars with OSSE

Pulsar mode data from the Oriented Scintillation Spectrometer Experiment (OSSE) onboard the Compton Gamma Ray Observatory (CGRO), with time resolution between 125 microsecs and 8 ms, have been analyzed for the presence of short-period gamma-ray pulsations. Observations of known point sources (including SN 1987A, SN 1993J, GRO J0422+32, and several pulsars) and of regions where higher densities of pulsars are expected (including the Galactic center, the Galactic plane and arms, and the Large Magellanic Cloud) are included in the study. Both isolated pulsars and pulsars in close binary systems are searched for; in the latter case, the quadratic coherence recovery technique is used to correct for broadening of the pulsar signal from orbital motion. No new gamma-ray pulsars have been detected. Upper limits on the pulsed gamma-ray flux from isolated pulsars in the 50-210 keV energy range of OSSE are between 0.2 x 10(exp -3) and 2.0 x 10(exp -3) photons/s/sq cm for pulse periods between 250 microsecs and 0.5 s. Upper limits on the pulsed flux from binary pulsars are between 1.5 x 10(exp -3) and 6.4 x 10(exp -3) photons/s/sq cm for the same energy band and pulse period range. We estimate that, in the Galaxy, there are fewer than approximately 125 isolated pulsars similar to PSR B1509-58 with radiation peaks in the OSSE band but undetected in the radio and X-rays bands.

Hertz, P.↗

Cygnus X-1: A Case for a Magnetic Accretion Disk?

With the advent of Rossi X-ray Timing Explorer (RXTE), which is capable of broad spectral coverage and fast timing, as well as other instruments which are increasingly being used in multi-wavelength campaigns (via both space-based and ground-based observations), we must demand more of our theoretical models. No current model mimics all facets of a system as complex as an x-ray binary. However, a modern theory should qualitatively reproduce - or at the very least not fundamentally disagree with - all of Cygnus X-l's most basic average properties: energy spectrum (viewed within a broader framework of black hole candidate spectral behavior), power spectrum (PSD), and time delays and coherence between variability in different energy bands. Below we discuss each of these basic properties in turn, and we assess the health of one of the currently popular theories: Comptonization of photons from a cold disk. We find that the data pose substantial challenges for this theory, as well as all other in currently discussed models.

Nowak, Michael A.↗

RXTE Observation of Cygnus X-1: Spectra and Timing

We present preliminary results from the analysis of an R.XTE observation of Cyg X-1 in the hard state. We show that the observed X-ray spectrum can be explained with a model for an accretion disk corona (ADC), in which a hot sphere is situated inside of a cold accretion disk (similar to an advection dominated model). ADC Models with a slab-geometry do not successfully fit the data. In addition to the spectral results we present the observed temporal properties of Cyg X-1, i.e. the coherence-function and the time-lags, and discuss the constraints the. temporal properties imply for the accretion geometry in Cyg X-1.

Wilms, J.↗

A Search for Short-Period Accreting Pulsars with BATSE

Accreting X-ray pulsar systems can be detected and monitored by the BATSE Pulsar Monitor at full sensitivity only above the Nyquist period of 2.048 s, since it uses the DISCLA data type. Systems with shorter periods than 2 s can be observed, but with a reduced sensitivity, since only the aliased power is measured. While persistent sources in the period range below that have been found by earlier spacecraft, transient systems may still be undiscovered, due to limited time coverage of the galactic plane with all-sky instruments. BATSE data with a time resolution of 31 ms (PSR single-sweep mode) has been collected for four energy channels spanning 20-50 keV , at scheduled times for particular detectors and detector combinations which view the galactic plane. The data spans Nov 1993 to present, with a typical exposure of 15000 s per day to approximately 1/8 of the plane. An accelerated FFT-based search is in progress on these data. Data are segmented into approximately 300 second intervals, barycentered for 3 possible source directions spaced by 30 degrees about the detector normal, with the time series accelerated for each of 15 steps, each spaced by 5 x 10(exp -5). To avoid loss of coherence due to system orbital velocities, FFTs are averaged over each 1/4 day interval separately. Results of this search are presented, including examples of detection of Her X-1, Cen X-3, and other pulsars.

Wilson, R. B.↗