Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Training and Validation of Spectral Gap Filling Algorithm for Cpf-Ceres Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is set to launch an SI-traceable reflective solar (RS) spectrometer aboard the International Space Station to measure Earth-reflected solar radiation with a radiometric uncertainty of 0.3% (k=1). The CPF intercalibration team has devised a cutting-edge methodology to accurately transfer the benchmark CPF calibration reference to the shortwave (SW) channel (200-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument. The spectral range of CPF measurements spans from 350-2300 nm, while the CERES SW channel measures the Earth-reflected broadband solar radiances between 200 nm to 5 μm. To conduct precise CPF-CERES intercalibration analysis, the CPF-like spectral radiances outside the CPF spectral range need to be estimated to match the CERES SW spectral range. In response, the team has developed a fast algorithm that leverages spectrally redundant information within the CPF-measured portion through principal component analysis (PCA) and utilizes pre-established spectral correlation relationships among wavelengths to extend the CPF spectrum below 350 nm and above 2300 nm. Our results show that the algorithm achieves excellent accuracy in generating the missing energy in the UV and IR portions. The RMS error in the UV region is less than 4.5x10-3 W/m2/sr/nm, while in the IR region, it is smaller than 8x10-5 W/m2/sr/nm. Our methodology was validated using measured EMIT radiance data, which covers the spectral range from 0.381 μm to 2.493 μm. We employed EMIT radiances within the wavelength range of 0.43 – 2.25 μm to generate radiances for both the shorter wavelength range (0.381 – 0.43 μm) and longer wavelength range (2.25 – 2.493 μm). The generated radiances agree very well with the measured EMIT radiances. The standard deviation in the integrated broadband radiances was about 0.1%, and the bias is less than 0.004% for over 1.5 million EMIT measured samples. These statistics show that the spectral gap filling algorithm is robust and effective in substantially reducing the spectral difference-induced uncertainty in the CPF-CERES intercalibration samples.

Qiguang Yang↗

Summary of the status of the Nimbus-7 SMMR

The present state of calibration of the Nimbus-7 SMMR is described, and its relevance to retrievals of sea surface temperatures is discussed. The asymmetry in the polarization rotation was studied by calibrating the SMMR signals without the polarization rotation correction within a data set consisting of about 300 orbits, and the phase shift was determined by regression analysis. The largest phase shift was observed in the 1.4 cm vertical polarization channel - almost 11 degrees. The in-orbit calibration adjustment scheme is described, and the result of applying it to the 4.6 cm vertical polarization channel is shown.

Gloersen, P.↗

End-to-end test of the electron-proton spectrometer

A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

Cash, B. L.↗

Design and construction of a wide angle diffuse source

A Multispectral Scanner (MSS) has been under development for some time and is now undergoing tests for final calibration. It has four bands, each containing six channels. Thus it has 24 detectors which receive radiation by fiber optics. It is shown that a spherical integrator makes a satisfactory extended source for the calibration of the scanner.

Mohr, E. I.↗

Calibration of a satellite infrared radiometer

The calibration procedure is described for a two-channel imaging radiometer on board the Heat Capacity Mapping Mission, a single sensor satellite in a near polar orbit. The Heat Capacity Mapping Radiometer measures radiation temperature and reflectivity with an instantaneous FOV of 600 m and a noise equivalent temperature of 0.4 K at 280 K in the thermal IR channel. Unexplained changes in the system during satellite launch were treated through comparison with surface/atmosphere data to force agreement. This necessitated an offset from the prelaunch calibration by 5.5 K. Later comparisons showed no difference. Possible explanations are presented.

Barnes, W. L.↗

Investigation of cloud properties and atmospheric stability with MODIS

The last half year was spent in preparing Version 1 software for delivery, and culminated in transfer of the Level 2 cloud mask production software to the SDST in April. A simulated MODIS test data set with good radiometric integrity was produced using MAS data for a clear ocean scene. ER-2 flight support and MAS data processing were provided by CIMSS personnel during the Apr-May 96 SUCCESS field campaign in Salina, Kansas. Improvements have been made in the absolute calibration of the MAS, including better characterization of the spectral response for all 50 channels. Plans were laid out for validating and testing the MODIS calibration techniques; these plans were further refined during a UW calibration meeting with MCST.

Menzel, P.↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Radiometric Performance of CERES Instruments Aboard Terra

The Terra satellite platform carries the first two flight models of the Clouds and the Earth’s Radiant Energy System, which make radiometric measurements of the Earth to examine the roles of cloud feedback and radiation balance in the Earth System. The Terra-borne instruments use three channels: the shortwave (0.2 - 5 µm), total (0.2 – 100 µm) and window (8 – 12 µm), which are calibrated using an onboard internal calibration module to track the long-term stability of each channel. Observed measurements are converted to top-of-atmosphere radiances by accounting for the instrument optics and detector sensitivity coefficients determined from prelaunch calibrations. Trends in the instrument’s radiometric performance determined through on-orbit calibrations and vicarious studies were applied, and these corrections have shown to produce a stable data record of radiative fluxes over the lifetime of the mission. Changes in instrument observations and new methods to account for them as a result of the discontinuation of station keeping for Terra will be discussed.

Alexander Jarnot↗

MSG SEVIRI Applications for Weather and Climate: Cloud Properties and Calibrations

SEVIRI data are cross-calibrated against the corresponding Aqua and Terra MODIS channels. Compared to Terra MODIS, no significant trends are evident in the 0.65, 0.86, and 1.6 micron channel gains between May 2004 and May 2006, indicating excellent stability in the solar-channel sensors. On average, the corresponding Terra reflectances are 12, 14, and 1% greater than the their SEVIRI counterparts. The Terra 3.8- micron channel brightness temperatures T are 7 and 4 K greater than their SEVIRI counterparts during day and night, respectively. The average differences between T for MODIS and SEVIRI 8.6, 10.8, 12.0, and 13.3- micron channels are between 0.5 and 2 K. The cloud properties are being derived hourly over Europe and, in initial comparisons, agree well with surface observations. Errors caused by residual calibration uncertainties, terminator conditions, and inaccurate temperature and humidity profiles are still problematic. Future versions will address those errors and the effects of multilayered clouds.

Minnis, Patrick↗

Determinability of inter-annual global and regional climatic changes of the earth radiation budget

The degradation characteristics of Earth Radiation Budget (ERB) experiments are examined with reference to the results of recent investigations into the calibration adjustments of the Wide Field of View channels on board the Nimbus 6 and 7 ERB experiments. The mechanisms of degradation are discussed, and changes in the transmissive and reflective properties of radiometers affecting their sensitivities and calibrations are estimated. It is emphasized that in order to observe interannual climate change on a global or a regional scale, calibration adjustments are a necessity.

Ardanuy, P. E.↗

The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

Meister, Gerhard↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗

EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a relative uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of 'insensitive' line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (plus 2nd order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIT and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

Thomas, Roger J.↗

LANDSAT instruments characterization

The present CALDUMP tape consists of five calibration files and one reduced calibration file. The calibration files, each with data of 200 pixels, cover an entire calibration region starting from the 6251 minor frame (mf). Program LEE.FOR was developed to edit these five files into seven .CAL files in the TAE mode. Program PCAL.FOR reads the .CAL files and plots the 1000 pixels of any scan line in linear or log scale. The typical spectra of the calibration region of forward and reverse scans are shown. The positions of the start and the end of shutter obscuration and the calibration pulse are shifted increasingly or decreasingly from Channel 1 to Channel 16, due to the timing of data acquisition. To produce TRAPP usable input files are, the following procedures need to be taken: (1) determine the start of shutter obscuration position; (2) determine the calibration pulse and background region relative to the start of shutter obscuration; and (3) determine the end of shutter obscuration position.

Lee, Y.↗

GOME Total Ozone and Calibration Error Derived Usign Version 8 TOMS Algorithm

The Global Ozone Monitoring Experiment (GOME) is a hyper-spectral satellite instrument measuring the ultraviolet backscatter at relatively high spectral resolution. GOME radiances have been slit averaged to emulate measurements of the Total Ozone Mapping Spectrometer (TOMS) made at discrete wavelengths and processed using the new TOMS Version 8 Ozone Algorithm. Compared to Differential Optical Absorption Spectroscopy (DOAS) techniques based on local structure in the Huggins Bands, the TOMS uses differential absorption between a pair of wavelengths including the local stiucture as well as the background continuum. This makes the TOMS Algorithm more sensitive to ozone, but it also makes the algorithm more sensitive to instrument calibration errors. While calibration adjustments are not needed for the fitting techniques like the DOAS employed in GOME algorithms, some adjustment is necessary when applying the TOMS Algorithm to GOME. Using spectral discrimination at near ultraviolet wavelength channels unabsorbed by ozone, the GOME wavelength dependent calibration drift is estimated and then checked using pair justification. In addition, the day one calibration offset is estimated based on the residuals of the Version 8 TOMS Algorithm. The estimated drift in the 2b detector of GOME is small through the first four years and then increases rapidly to +5% in normalized radiance at 331 nm relative to 385 nm by mid 2000. The lb detector appears to be quite well behaved throughout this time period.

Gleason, J.↗

Landsat 8 Remote Sensing Reflectance (Rrs) Products: Evaluations, Intercomparisons, and Enhancements

The Operational Land Imager (OLI) onboard Landsat-8 is generating high-quality aquatic science products, the most critical of which is the remote sensing reflectance (Rrs), defined as the ratio of water-leaving radiance to the total downwelling irradiance just above water. The quality of the Rrs products has not, however, been extensively assessed. This manuscript provides a comprehensive evaluation of Level-1B, i.e., top of atmosphere reflectance, and Rrs products available from OLI imagery under near-ideal atmospheric conditions in moderately turbid waters. The procedure includes a) evaluations of the Rrs products at sites included in the Ocean Color component of the Aerosol Robotic Network (AERONET-OC), b) intercomparisons and cross-calibrations against other ocean color products, and c) optimizations of vicarious calibration gains across the entire OLI observing swath. Results indicate that the near-infrared and shortwave infrared (NIR-SWIR) band combinations yield the most robust and stable Rrs retrievals in moderately turbid waters. Intercomparisons against products derived from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Moderate Resolution Imaging Spectroradiometer onboard the Aqua platform (MODISA) indicate slight across-track non-uniformities (<1%) associated with OLI scenes in the blue bands. In both product domains (TOA and Rrs), on average, the OLI products were found larger in radiometric responses in the blue channels. Following the implementation of updated vicarious calibration gains and accounting for across-track non-uniformities, matchup analyses using independent in-situ validation data confirmed improvements in Rrs products. These findings further support high-fidelity OLI-derived aquatic science products in terms of both demonstrating a robust atmospheric correction method and providing consistent products across OLI's imaging swath.

Pahlevan, Nima↗

Evaluation of EPIC Oxygen Bands Stability With Radiative Transfer Simulations Over the South Pole

The Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) satellite orbiting the Sun at the Lagrange-1 point was launched without onboard calibration systems. Vicarious calibration is conducted for 8 of the 10 UV/VIS/NIR channels using other low earth orbiting satellite instruments, while its two O 2 bands (688 nm and 764nm) rely on indirect moon-view calibrations because the same narrow-band O 2 bands are not readily available from other in-flight instruments. This study compares EPIC measurements from the four O 2 bands aiming at examining sensor stability over a uniquely suited location, i.e., the permanently snow-covered South Pole. The study utilizes radiative transfer model simulations with in-situ atmospheric soundings taken at South Pole during months of December and January from 2015 to 2022. The absolute discrepancy between the model simulations and observations is less than 1.0% for the two reference bands, but 5.75% and 15.63% for the 688nm, and 764 nm absorption bands, respectively. The simulated A-band and B-band ratios are 16.09% and 4.74% higher than that from the observations. Various sensitivities are conducted to estimate possible contributions to the discrepancies from input atmospheric profiles, spectral surface albedos and surface BRDF. While none of the input uncertainties is likely to account for the large discrepancies in the oxygen absorption bands, a small shift in the instrument response function could be the main reason for these biases. On the other hand, the model simulations are able to capture systematic variations with observed angular measurements and explain the multi-year trends found in observed O 2 band ratios due to satellite orbit shifting. When model simulated contributions from the angle variations are deducted from the observed O 2 band ratios, the residual O 2 band ratios are found to be stable since 2015.

EPIC↗

Tone calibration technique: A digital signaling scheme for mobile applications

Residual carrier modulation is conventionally used in a communication link to assist the receiver with signal demodulation and detection. Although suppressed carrier modulation has a slight power advantage over the residual carrier approach in systems enjoying a high level of stability, it lacks sufficient robustness to be used in channels severely contaminated by noise, interference and propagation effects. In mobile links, in particular, the vehicle motion and multipath waveform propagation affect the received carrier in an adverse fashion. A residual carrier scheme that uses a pilot carrier to calibrate a mobile channel against multipath fading anomalies is described. The benefits of this scheme, known as tone calibration technique, are described. A brief study of the system performance in the presence of implementation anomalies is also given.

Davarian, F.↗