Examining Ohmic Losses in Fuel-Cell Catalyst Layers with Different Pt/C Ratios
A model of a fuel-cell cathode with distinct proton conductivities at the agglomerate and electrode scales was used to simulate polarization curves under conditions with facile oxygen transport. Here, the model was applied to electrodes containing agglomerates with different ratios of platinum to carbon in order to examine the hypothesis that intra-agglomerate proton conductivity is substantially lower than ionomer conductivity. The model predicts decreasing performance and increasing sensitivity to Pt/C ratio as intra-agglomerate conductivity declines relative to a constant through-electrode conductivity. Experiments on catalyst layers with Vulcan supports do not show the predicted trend indicating that mesoscale intra-agglomerate conductivity is not orders of magnitude lower than bulk ionomer conductivity.