At least 253 records · Page 14

Advanced collapsible tank for liquid containment

Tanks for bulk liquid containment will be required to support advanced planetary exploration programs. Potential applications include storage of potable, process, and waste water, and fuels and process chemicals. The launch mass and volume penalties inherent in rigid tanks suggest that collapsible tanks may be more efficient. Collapsible tanks are made of lightweight flexible material and can be folded compactly for storage and transport. Although collapsible tanks for terrestrial use are widely available, a new design was developed that has significantly less mass and bulk than existing models. Modelled after the shape of a sessible drop, this design features a dual membrane with a nearly uniform stress distribution and a low surface-to-volume ratio. It can be adapted to store a variety of liquids in nearly any environment with constant acceleration field. Three models of 10L, 50L, and 378L capacity have been constructed and tested. The 378L (100 gallon) model weighed less than 10 percent of a commercially available collapsible tank of equivalent capacity, and required less than 20 percent of the storage space when folded for transport.

Flanagan, David T.↗

High-Capacity Spacesuit Evaporator Absorber Radiator (SEAR)

Future human space exploration missions will require advanced life support technology that can operate across a wide range of applications and environments. Thermal control systems for space suits and spacecraft will need to meet critical requirements for water conservation and adaptability to highly variable thermal environments. This paper describes a Space Evaporator Absorber Radiator (SEAR) that has been designed to meet performance requirements for future life support systems. A SEAR system comprises a lithium chloride absorber radiator (LCAR) for heat rejection coupled with a space water membrane evaporator (SWME) for heat acquisition. SEAR systems provide heat pumping to minimize radiator size, thermal storage to accommodate variable environmental conditions, and water absorption to minimize use of expendables. We have built and tested a flightlike, high-capacity LCAR, demonstrated its performance in thermal vacuum tests, and explored the feasibility of an ISS demonstration test of a SEAR system. The new LCAR design provides the same cooling capability as prior LCAR prototypes while enabling over 30% more heat absorbing capacity. Studies show that it should be feasible to demonstrate SEAR operation in flight by coupling with an existing EMU on the space station.

Izenson, Michael G.↗

Solution-Based, Anion-Doping of Li 4 Ti 5 O 12 Nanoflowers for Lithium-Ion Battery Applications

Solution–based, anionic doping represents a convenient strategy with which to improve upon the conductivity of candidate anode materials such as Li 4 Ti 5 O 12 (LTO). As such, novel synthetic hydrothermally–inspired protocols have primarily been devised herein, aimed at the large–scale production of unique halogen–doped, micron–scale, three–dimensional, hierarchical LTO flower–like motifs. Although fluorine (F) doping has been explored, the use of chlorine (Cl) dopants is the primary focus here. Several experimental variables, such as dopant amount, lithium hydroxide concentration, and titanium butoxide purity, were probed and perfected. Furthermore, the Cl doping process did not damage the intrinsic LTO morphology. The analysis, based on interpreting a compilation of SEM, XRD, XPS, and TEM–EDS results, was used to determine an optimized dopant concentration of Cl. Electrochemical tests demonstrated an increased capacity via cycling of 12 % for a Cl–doped sample as compared with pristine LTO. Moreover, the Cl–doped LTO sample described in this study exhibited the highest discharge capacity yet reported at an observed rate of 2C for this material at 143mAh g –1 . Overall, these data suggest that the Cl dopant likely enhances not only the ion transport capabilities, but also the overall electrical conductivity of our as–prepared structures. Furthermore, to help explain these favorable findings, theoretical DFT calculations were used to postulate that the electronic conductivity and Li diffusion were likely improved by the presence of increased Ti 3+ ion concentration coupled with widening of the Li migration channel.

25 ENERGY STORAGE↗

The Upgrade of the SNS Extraction Kicker Power Supplies for the Proton Power Upgrade

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS) aims to enhance the linear accelerator's power output from 1.4 to 2.8 megawatts. A critical focus lies on upgrading the Extraction Kicker Power Supplies to handle the amplified beam power. The existing capacitor charging power supplies lacked the capability to charge the Blumlein-type Pulse Forming Network (PFN) to the required 40 kV at a repetition rate of 60 Hz. To address this limitation, an initial solution involving the use of a resonant charging circuit was proposed. However, a challenge arose with a self-firing issue in the thyristor switch, which proved unsolvable within the given timeframe. Facing a critical decision point in the project, an alternative approach was explored: integrating a supplementary power supply to enhance the overall power capacity. This solution was tested and ultimately chosen as the path forward. To accommodate the additional power supply, the power distribution system had to undergo upgrades. Throughout this endeavor, a comprehensive examination of the system took place, with meticulous identification of key components. This paper delves into the technical challenges encountered during the process and the corresponding solutions that were implemented.

Tan, Yugang [ORNL] (ORCID:0000000155968252)↗

Shorting at Long Duration: Impact of Extended Discharge Capacity on Battery Solid Electrolytes

Long-duration energy storage (LDES) is critical to a stable, resilient, and decarbonized electric grid. While batteries are emerging as important LDES devices, extended, high-power discharges necessary for cost-competitive LDES present new materials challenges. Here, focusing on a new generation of low-temperature molten sodium batteries, we explore here unique phenomena related to long-duration discharge through a well-known solid electrolyte, NaSICON. Specifically, molten sodium symmetric cells at 110°C were cycled at 0.1 A cm -2 for 1-23 h discharges. Longer discharges led to unstable overpotentials, reduced resistances, and decreased electrolyte strength, caused by massive sodium penetration not observed in shorter duration discharges. Scanning electron microscopy informed mechanisms of sodium penetration and even “healing” during shorter-duration cycling. Importantly, these findings show that traditional, low-capacity, shorter-duration tests may not sufficiently inform fundamental materials phenomena that will impact LDES battery performance. This case highlights the importance that candidate LDES batteries be tested under pertinent long-duration conditions.

25 ENERGY STORAGE↗

Can we safely go to 200 °C? An integrated approach to assessing impacts to the engineered barrier system in a high-temperature repository

Abstract. This presentation gives on overview of the complex thermo-hydro-mechanical-chemical (THMC) processes occurring during the disposal of heat-producing high-level radioactive waste in geologic repositories. A specific focus is on the role of compacted bentonite, which is commonly used as an engineered backfill material for emplacement tunnels because of its low permeability, high swelling pressure, and radionuclide retention capacity. Laboratory and field tests integrated with THMC modeling have provided an effective way to deepen our understanding of temperature-related perturbations in the engineered barrier system; however, most of this work has been conducted for maximum temperatures around 100 ∘C. In contrast, some international disposal programs have recently started investigations to understand whether local temperatures in the bentonite of up to 200 ∘C could be tolerated with no significant changes to safety relevant properties. Raising the maximum temperature is attractive for economical and safety reasons but faces the challenge of exposing the bentonite to significant temperature increases. Strong thermal gradients may induce complex moisture transport processes while geochemical processes, such as cementation and perhaps also illitization effects may occur, all of which could strongly affect the bentonite and near-field rock properties. Here, we present initial investigations of repository behavior exposed to strongly elevated temperatures. We will start discussing our current knowledge base for temperature effects in repositories exposed to a maximum temperature of 100 ∘C, based on data and related modeling analysis from a large heater experiment conducted for over 18 years in the Grimsel Test Site in Switzerland. We then show results from coupled THMC simulations of a nuclear waste repository in a clay formation exposed to a maximum temperature of 200 ∘C. We also explore preliminary data from a bench-scale laboratory mock-up experiment, which was designed to represent the strong THMC gradients occurring in a “hot” repository, and we finally touch on a full-scale field heater test to be conducted soon in the Grimsel Test Site underground research laboratory in Switzerland (referred to as HotBENT).

Birkholzer, Jens T. (ORCID:0000000279891912)↗

Nondestructive testing of electro thermal devices

This paper describes the results of a recent investigation into 'thermal time constant' nondestructive testing of high reliability electrical fuses. The use of established nondestructive test technology for examining the quality and firing characteristics of electro-explosive devices has been successfully applied to the inspection and prediction of the functional performance of electrical fuses. The technique requires application of a low level current pulse to the electrical fuse with an oscilloscope display of the curve as generated by the temperature coefficient of resistance feedback. The heating curve of temperature vs time is composed of one predominant thermal time constant, which is the product of the test unit's thermal capacity and thermal resistance. It has been found that the quality of the individual electrical fuse, for instance, the relative condition of the critical internal weld or solder joint, can be examined nondestructively.

Earnest, J. E., Jr.↗

Nickel hydrogen cell characterization test results

Charge control studies on nickel hydrogen cells are discussed. Characterization test data for the cells are presented in graphical form. The test areas covered were capacity versus temperature, ampere-hour cycling efficiency, and the charge method which involved voltage level with current limiting.

Otzinger, B.↗

Reconnaissance and recovery of the brighter asteroids. Brief summary of the entire project

An inexpensive method of baking large (8- by 10-inch) IIIa-J plates in 2 percent forming gas was found and successfully tested. The large storage capacity and fine grain structure of the emulsion made the sky fog negligible on plates of one-hour exposure at Link. Plates were taken through the end of October 18, 1981 on various asteroids from the recent critical lists published in the Minor Planet Circulars and the Russian Ephemeris of Minor Planets.

Edmonson, F. K.↗

An advanced Ni-Cd battery cell design

The evolution of an advanced Ni-Cd space battery cell design continues to prove very promising. High oxygen/hydrogen gas recombination rates (currently up to a C/5 charge rate) and increased electrolyte activation level tolerance (currently up to 5.6 grams Ah of positive capacity) were demonstrated by test. A superior performance, extended life battery cell offering advantages should soon be available for mission applications

Miller, L.↗

High capacity demonstration of honeycomb panel heat pipes

High capacity honeycomb panel heat pipes were investigated as heat rejection radiators on future space platforms. Starting with a remnant section of honeycomb panel measuring 3.05-m long by 0.127-m wide that was originally designed and built for high-efficiency radiator fins, features were added to increase thermal transport capacity and thus permit test evaluation as an integral heat transport and rejection radiator. A series of subscale panels were fabricated and reworked to isolate individual enhancement features. Key to the enhancement was the addition of a liquid sideflow that utilizes pressure priming. A prediction model was developed and correlated with measured data, and then used to project performance to large, space-station size radiators. Results show that a honeycomb panel with 5.08-cm sideflow spacing and core modification will meet the design load of a 50 kW space heat rejection system.

Tanzer, H. J.↗

Aerobic fitness in women and responses to lower body negative pressure

The role of tolerance to orthostatic stress in the maintenance of high aerobic fitness in women was investigated by examining the responses of heart rate, stroke volume, cardiac output, Heather index of contractility, arterial pressure, peripheral resistance, change in calf circumference, and thoracic impedance of healthy female subjects to lower body negative pressure (LBNP) applied for 5 min at -50 mm Hg or until a subject became presyncopal. The testing protocol involved a stepwise reduction in pressure and consisted of two parts: an LBNP test in supine position followed by a treadmill test to peak aerobic capacity. Women were found to exhibit the same response pattern to LBNP as was previously reported by Convertino et al. (1984) for men. The results do not support the hypothesis that orthostatic tolerance in women is inversely related to aerobic fitness, as demonstrated by a finding that the peak aerobic capacity of subjects who became presyncopal did not differ from the peak of the tolerant subjects, and that hemodynamic responses to LBNPL were not a function of aerobic capacity.

Frey, Mary Anne Bassett↗

Advanced underwater lift device

Flexible underwater lift devices ('lift bags') are used in underwater operations to provide buoyancy to submerged objects. Commercially available designs are heavy, bulky, and awkward to handle, and thus are limited in size and useful lifting capacity. An underwater lift device having less than 20 percent of the bulk and less than 10 percent of the weight of commercially available models was developed. The design features a dual membrane envelope, a nearly homogeneous envelope membrane stress distribution, and a minimum surface-to-volume ratio. A proof-of-concept model of 50 kg capacity was built and tested. Originally designed to provide buoyancy to mock-ups submerged in NASA's weightlessness simulators, the device may have application to water-landed spacecraft which must deploy flotation upon impact, and where launch weight and volume penalties are significant. The device may also be useful for the automated recovery of ocean floor probes or in marine salvage applications.

Flanagan, David T.↗