Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Long-Term High-Temperature High-Pressure Cable for Geothermal Logging Tools

Downhole logging tools are commonly used to characterize multi-thousand-foot geothermal wells. The elevated temperatures, pressures, and harsh chemical environments present significant challenges for the long-term operation of these tools, especially when real-time data transmission to the surface is required via data cable lines. Teflon-based single or multi-conductor cables with grease-filled cable heads are typically used for downhole tools. However, over extended periods of operation, the gr

15 GEOTHERMAL ENERGY↗

Low Frequency Cable Dual Shield Penetration Using Complete Transfer Immittance Model

This report discusses low frequency coupling and subsequent penetration of a dual shield cable using a transfer immittance model with reciprocal sources. Configurations include: 1) where the cable is above a ground plane and shorted at both ends, 2) a monopole arrangement where it is shorted at one end and open at the other end, and 3) a monopole arrangement where the open end is loaded by a disc. The open circuit voltage within the cable is estimated for each case.

42 ENGINEERING↗

SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only SMR technologies, but also Advanced Reactors design. An Electrical Penetration Assembly (EPA) is a component used to allow electrical power and signal conductors as well as optical fiber through the nuclear reactor’s containment structure while maintaining a pressure barrier. The EPA ensures the containment's integrity both during the normal operation and also accident conditions by providing a sealed passage for power and signals. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and also more severe normal operating conditions.This document describes cost effective approaches to qualify a unique EPA for Small Modular Reactor (SMR) technologies as legacy LWR EPA technologies will likely have inherent material performance insufficiencies. The DBA profiles for SMRs (and some Advanced Reactor Technologies) are more severe than the legacy qualification requirements making the design of the qualification testing system challenging as the temperatures and pressures can approach the limits permitted by ASME Pressure Vessel Code, as well as accident temperatures exceeding the capability of polymeric gaskets and dielectrics. Small Modular Reactors are designed to have, as the name suggests, modularity which implies sized for factory fabrication and subsequent assembly at the power plant site. SMR containment is much smaller than a legacy Light Water Reactor containment. The containment walls are likely to be comprised of stainless steel. Qualifying Electrical Penetration Assemblies (EPAs) through these steel vessels are of interest in this work. Methods are presented here that discuss critical safety and cost effectiveness for these SMR EPA’s test systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flat cable insulation stripping machine

Flat cable insulation stripping machine operates on a principle of variable parameters of abradive wheel speed, wheel pressure on the flat cable, and flat cable feed speed into the abradive wheel. Application of connectors is handled efficiently with this flat terminal termination technique.

Schaefer, J. H.↗

Checking flat conductor cable spacing by means of a moire pattern

Moire tester detects small variations in flat conductor cable spacing by a quick, visual inspection. This device compares the cable to be tested with the negative of a very precise standard cable. The moire, consisting of bands of light and dark zones and its irregularities, can be interpreted as errors in spacing.

Angele, W.↗

Dynamics of a spinning space station with a counterweight connected by multiple cables.

A unique and relatively simple approach is presented for obtaining the linearized equations of motion. A conservative system consisting of two rigid bodies connected by any number of massless cables with linear axial stiffness is assumed. The cable forces and torques are expanded in a Taylor series about the equilibrium values of the system coordinates which results in a cable stiffness matrix. The method of obtaining the equilibrium values of the coordinates is discussed and results are presented. The range of validity of the linear model is determined by comparing results with a digital simulation of the nonlinear system.

Nixon, D. D.↗

A proposed adjustable RF cable connector

In system that requires negligible loss, it may be necessary to adjust cable length to exact multiple of transmitted wavelength. Adjustable cable connector saves time and cost by eliminating need to add to or cut from cable. Device was especially designed for use with high frequencies. For particular application, connector of suitable dimensions should be used.

Stringer, E. J.↗

Stable group delay cable

It was found that group delay is function of pressure in air dielectric coaxial cable. For example, 600-ft air dielectric cable will change phase 10 deg at 150 MHz when air pressure in cable changes from zero to 20 psi.

Clements, P. A.↗

User's guide for a computer program to analyze the LRC 16 ft transonic dynamics tunnel cable mount system

The theoretical derivation of the set of equations is discussed which is applicable to modeling the dynamic characteristics of aeroelastically-scaled models flown on the two-cable mount system in a 16 ft transonic dynamics tunnel. The computer program provided for the analysis is also described. The program calculates model trim conditions as well as 3 DOF longitudinal and lateral/directional dynamic conditions for various flying cable and snubber cable configurations. Sample input and output are included.

Barbero, P.↗

The three dimensional motion and stability of a rotating space station-cable - Counterweight configuration

The three dimensional equations of motion for a cable connected space station - counterweight system are developed using a Lagrangian formulation. The system model employed allows for cable and end body damping and restoring effects. The equations are then linearized about the equilibrium motion and nondimensionalized. To first degree, the out-of-plane equations uncouple from the in-plane equations. Therefore, the characteristic polynomials for the in-plane and out-of-plane equations are developed and treated separately. From the general in-plane characteristic equation, necessary conditions for stability are obtained. The Routh-Hurwitz necessary and sufficient conditions for stability are derived for the general out-of-plane characteristic equation. Special cases of the in-plane and out-of-plane equations (such as identical end masses, and when the cable is attached to the centers of mass of the two end bodies) are then examined for stability criteria.

Bainum, P. M.↗

The three dimensional motion and stability of a rotating space station: Cable-counterweight configuration

The three dimensional equations of motion for a cable connected space station--counterweight system are developed using a Lagrangian formulation. The system model employed allows for cable and end body damping and restoring effects. The equations are then linearized about the equilibrium motion and nondimensionalized. To first degree, the out-of-plane equations uncouple from the inplane equations. Therefore, the characteristic polynomials for the in-plane and out-of-plane equations are developed and treated separately. From the general in-plane characteristic equation, necessary conditions for stability are obtained. The Routh-Hurwitz necessary and sufficient conditions for stability are derived for the general out-of-plane characteristic equation. Special cases of the in-plane and out-of-plane equations (such as identical end masses, and when the cable is attached to the centers of mass of the two end bodies) are then examined for stability criteria.

Bainum, P. M.↗

Design, development, fabrication and testing of high temperature Flat Conductor Cable (FCC)

The results are presented of a development program for a flat, 25-conductor signal cable and a flat, 3-conductor power cable. Flat cables employ conductors made of strips or flattened round copper conductors insulated with polyimide films. It is shown that conductor thickness ranges from 0.003 to 0.010 inch, and begins to soften and loose mechanical strength at temperatures above 200 C.

Rigling, W. S.↗

Cables and connectors: A compilation

A technological compilation on devices and techniques for various types of electrical cables and connections is presented. Data are reported under three sections: flat conductor cable technology, newly developed electrical connectors, and miscellaneous articles and information on cables and connector techniques.

Source record↗

Overhead tray for cable test system

System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.

Saltz, K. T.↗

Relative stiffness of flat-conductor cable

Bending moment data were taken on ten different cable samples and normalized to express all stiffness factors in terms of cable 5.1 cm in width. Relative stiffness data and nominal physical characteristics are tabulated and presented in graphical form for designers who may be interested in finding torques exerted on critical components by short lengths of cable.

Hankins, J. D.↗

Splicing shielded cables

Simple repair technique retains cable characteristic impedance. Shielded-Cable Splicing Technique retains cable characteristic impedance. Procedure involves splicing inner conductors in staggered pattern, installing jumper braid by heat-shrinking two solder sleeves, and placing insulation sleeve over repaired section and heat-shrinking it. Two possible insulation materials are modified polyvinylidene fluoride and polytetrafluoroethylene.

Lind, W. P.↗

Test report for twinax cable (Rockwell type MB0150-051)

A controlled impedance twisted pair shielded cable was tested to determine the frequency response and effects of mismatched termination. It was found that a long length of this cable, about 100 feet, exhibited a frequency sensitive attenuation roll-off greater than 1.5 db down at 5 MHz. It was also determined that improper termination resulted in losses of 1/2 to 1 db within the frequency range of 200 KHz to greater than 1-1/2 MHz. The test results indicate a possible problem where mismatched connectors are used in video signal cables.

Doland, G. D.↗