ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

Robotic Specialization in Autonomous Robotic Structural Assembly

Robotic in-space assembly of large space structures is a long-term NASA goal to reduce launch costs and enable larger scale missions. Recently, researchers have proposed using discrete lattice building blocks and co-designed robots to build high-performance, scalable primary structure for various on-orbit and surface applications. These robots would locomote on the lattice and work in teams to build and reconfigure building-blocks into functional structure. However, the most reliable and efficient robotic system architecture, characterized by the number of different robotic 'species' and the allocation of functionality between species, is an open question. To address this problem, we decompose the robotic building-block assembly task into functional primitives and, in simulation, study the performance of the the variety of possible resulting architectures. For a set consisting of five process types (move self, move block, move friend, align bock, fasten block), we describe a method of feature space exploration and ranking based on energy and reliability cost functions. The solution space is enumerated, filtered for unique solutions, and evaluated against energy and reliability cost functions for various simulated build sizes. We find that a 2 species system, dividing the five mentioned process types between one unit cell transport robot and one fastening robot, results in the lowest energy cost system, at some cost to reliability. This system enables fastening functionality to occupy the build front while reducing the need for that functional mass to travel back and forth from a feed station. Because the details of a robot design affect the weighting and final allocation of functionality, a sensitivity analysis was conducted to evaluate the effect of changing mass allocations on architecture performance. Future systems with additional functionalities such as repair, inspection, and others may use this process to analyze and determine alternative robot architectures.

Bernus, Borbala↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

pnnl/simple-building-calculator

The Simple Building Calculator is a web application that estimates annual energy use using regression models that have been fit to simulation results for the DOE Commercial Prototype Building Models. The tool is a single-page application that will allow a user to rapidly analyze the impact of energy efficiency measures and design options on building performance. As it uses linear regression models rather than more complicated machine learning models or physics based simulation, the tool can deploy easily and run client-side.

Xu, Weili↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Computerized energy analysis for the Mars operations support building

A detailed computerized building load simulation of the Operations Support Building at the Mars Deep Space Station, Goldstone, California is described. Five energy conservation suggestions were investigated prior to implementation. The results showed that cost savings of about 16 percent of present energy costs are possible.

Yung, C. S.↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Geothermal: Borefield Design, Thermal Conductivity, and Subsurface Modeling Data - Chicago, IL

This dataset encompasses the development of a geothermal energy system for the West Woodlawn neighborhood in Chicago, Illinois. This project is part of a broader initiative to design and deploy geothermal heating and cooling systems at a community scale. The dataset includes thermal conductivity test results, calculations for borehole sizing based on the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) method, as well as simulated thermal loads based on actual energy usage from individual buildings. Also provided here are files used for numerical modeling via COMSOL Multiphysics to simulate borefield design and subsurface thermal behavior. Two manuscripts are attached, which outline the broad objectives of the project and a description of the numerical modeling methodology and results.

15 GEOTHERMAL ENERGY↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Advanced Multiphysics Simulation Capability for Radiant's Microreactor Design

Argonne National Laboratory and Idaho National Laboratory, through a Department of Energy Gateway for Accelerated Innovation in Nuclear Voucher, supported key analysis needs of Radiant related to (i) air jacket thermal fluid performance, (ii) evaluation of decay heat source terms defining air jacket technical requirements, and (iii) assessment of modeling methodologies employed for core analysis. All of these activities center on numerical simulation of various aspects of Kaleidos using the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, the Cardinal multiphysics application, the OpenMC Monte Carlo code, and the Nek5000 computational fluid dynamics (CFD) code. This project builds upon an earlier Nuclear Energy Advanced Modeling and Simulation (NEAMS) Thermal-Hydraulic (T/H) Center of Excellence (CoE) project focused on initial demonstration of Cardinal multiphysics simulation of High Temperature Gas Reactors (HTGRs) and now focuses on Radiant’s Kaleidos concept.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BEopt™ (Building Energy Optimization Tool) version 3.0.1 3/16/2023 [SWR-05-41]

The BEopt™ (Building Energy Optimization Tool) software provides capabilities to evaluate residential building designs and identify cost-optimal efficiency packages at various levels of whole-house energy savings along the path to zero net energy. The BEopt software can be used to analyze both new construction and existing home retrofits, as well as single-family detached and multi-family buildings, through evaluation of single building designs, parametric sweeps, and cost-based optimizations. The BEopt software provides detailed simulation-based analysis based on specific house characteristics, such as size, architecture, occupancy, vintage, location, and utility rates. Discrete envelope and equipment options, reflecting realistic construction materials and practices, are evaluated. The BEopt software uses EnergyPlus®, the Department of Energy's flagship simulation engine. Simulation assumptions are based on ANSI/RESNET/ICC Standards and the Building America Housing Simulation Protocols. The sequential search optimization technique used by the BEopt software: Finds minimum-cost building designs at different target energy-savings levels Identifies multiple near-optimal designs along the path, allowing for equivalent solutions based on builder or contractor preference. Download A BEopt™ Version 3.0.1 Beta release (Mar. 16, 2023) is now available. Download the BEopt 3.0.1 Beta setup file.

Christensen, Craig↗