Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

HRP's Healthcare Spin-Offs Through Computational Modeling and Simulation Practice Methodologies

Spaceflight missions expose astronauts to novel operational and environmental conditions that pose health risks that are currently not well understood, and perhaps unanticipated. Furthermore, given the limited number of humans that have flown in long duration missions and beyond low Earth-orbit, the amount of research and clinical data necessary to predict and mitigate these health and performance risks are limited. Consequently, NASA's Human Research Program (HRP) conducts research and develops advanced methods and tools to predict, assess, and mitigate potential hazards to the health of astronauts. In this light, NASA has explored the possibility of leveraging computational modeling since the 1970s as a means to elucidate the physiologic risks of spaceflight and develop countermeasures. Since that time, substantial progress has been realized in this arena through a number of HRP funded activates such as the Digital Astronaut Project (DAP) and the Integrated Medical Model (IMM). Much of this success can be attributed to HRP's endeavor to establish rigorous verification, validation, and credibility (VV&C) processes that ensure computational models and simulations (M&S) are sufficiently credible to address issues within their intended scope. This presentation summarizes HRP's activities in credibility of modeling and simulation, in particular through its outreach to the community of modeling and simulation practitioners. METHODS: The HRP requires all M&S that can have moderate to high impact on crew health or mission success must be vetted in accordance to NASA Standard for Models and Simulations, NASA-STD-7009 (7009) [5]. As this standard mostly focuses on engineering systems, the IMM and DAP have invested substantial efforts to adapt the processes established in this standard for their application to biological M&S, which is more prevalent in human health and performance (HHP) and space biomedical research and operations [6,7]. These methods have also generated substantial interest by the broader medical community though institutions like the National Institutes of Health (NIH) and the Food and Drug Administration (FDA) to develop similar standards and guidelines applicable to the larger medical operations and research community. DISCUSSION: Similar to NASA, many leading government agencies, health institutions and medical product developers around the world are recognizing the potential of computational M&S to support clinical research and decision making. In this light, substantial investments are being made in computational medicine and notable discoveries are being realized [8]. However, there is a lack of broadly applicable practice guidance for the development and implementation of M&S in clinical care and research in a manner that instills confidence among medical practitioners and biological researchers [9,10]. In this presentation, we will give an overview on how HRP is working with the NIH's Interagency Modeling and Analysis Group (IMAG), the FDA and the American Society of Mechanical Engineers (ASME) to leverage NASA's biomedical VV&C processes to establish a new regulatory standard for Verification and Validation in Computational Modeling of Medical Devices, and Guidelines for Credible Practice of Computational Modeling and Simulation in Healthcare.

Mulugeta, Lealem↗

Energy storage: The future enabled by nanomaterials

Lithium-ion batteries, which power portable electronics, electric vehicles, and stationary storage, have been recognized with the 2019 Nobel Prize in chemistry. The development of nanomaterials and their related processing into electrodes and devices can improve the performance and/or development of the existing energy storage systems. We provide a perspective on recent progress in the application of nanomaterials in energy storage devices, such as supercapacitors and batteries. The versatility of nanomaterials can lead to power sources for portable, flexible, foldable, and distributable electronics; electric transportation; and grid-scale storage, as well as integration in living environments and biomedical systems. To overcome limitations of nanomaterials related to high reactivity and chemical instability caused by their high surface area, nanoparticles with different functionalities should be combined in smart architectures on nano- and microscales. The integration of nanomaterials into functional architectures and devices requires the development of advanced manufacturing approaches. We discuss successful strategies and outline a roadmap for the exploitation of nanomaterials for enabling future energy storage applications, such as powering distributed sensor networks and flexible and wearable electronics.

catalysis (heterogeneous)↗

Covalently-Bonded Laminar Assembly of Van der Waals Semiconductors with Polymers: Toward High-Performance Flexible Devices

Van der Waals semiconductors (vdWS) offer superior mechanical and electrical properties and are promising for flexible microelectronics when combined with polymer substrates. However, the self-passivated vdWS surfaces and their weak adhesion to polymers tend to cause interfacial sliding and wrinkling, and thus, are still challenging the reliability of vdWS-based flexible devices. Here, in this study, an effective covalent vdWS–polymer lamination method with high stretch tolerance and excellent electronic performance is reported. Using molybdenum disulfide (MoS 2 ) and polydimethylsiloxane (PDMS) as a case study, gold–chalcogen bonding and mercapto silane bridges are leveraged. The resulting composite structures exhibit more uniform and stronger interfacial adhesion. This enhanced coupling also enables the observation of a theoretically predicted tension-induced band structure transition in MoS 2 . Moreover, no obvious degradation in the devices’ structural and electrical properties is identified after numerous mechanical cycle tests. This high-quality lamination enhances the reliability of vdWS-based flexible microelectronics, accelerating their practical applications in biomedical research and consumer electronics.

36 MATERIALS SCIENCE↗

An improved aesthesiometer

Biomedical tool measures cutaneous sensory perception by allowing consistent application of regular and determinable pressure to skin of the individual. Device is of relatively simple construction, inexpensive to manufacture, and easy to operate.

Wright, D.↗

Nanotechnologv Enabled Biological and Chemical Sensors

Nanotechnology is an enabling technology that will impact almost all economic sectors: one of the most important and with great potential is the health/medical sector. - Nanomaterials for drug delivery - Early warning sensors - Implantable devices - Artificial parts with improved characteristics Carbon nanotubes and nanofibers show promise for use in sensor development, electrodes and other biomedical applications.

Koehne, Jessica↗

Advances in bioelectronics: Materials, devices, and translational applications

Modern electronics and materials science are bringing revolutionary advances to biointerface design and are shattering the limits of what is possible in the areas of biomedical diagnostics and sensing, neuroscience, and prosthetics. Furthermore, this special issue highlights the rapid progress in all areas of bioelectronics and includes contributions that explore the interfaces between electronics, materials science, and other engineering disciplines, as well as biochemistry, biophysics, and general biology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Transseptal Guidewire Stabilization for Device Closure of a Large Pulmonary Arteriovenous Malformation

A 46-year-old man presenting with massive hemoptysis was found to have a large pulmonary arteriovenous malformation (PAVM) in the right lung. Closure of the PAVM with an Amplatzer-type duct occluder was hampered by inability to advance the device delivery sheath into the PAVM due to vessel tortuosity and inadequate guidewire support. Atrial septal puncture was performed and a femorofemoral arteriovenous guidewire loop through the right pulmonary artery, PAVM, and left atrium was created. Traction on both ends of the guidewire loop allowed advancement of the device delivery sheath into the PAVM and successful completion of the procedure. Transseptal guidewire stabilization can be a valuable option during device closure of large PAVMs when advancement, stability, or kinking of the device delivery sheath is an issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mammograms restoration by using Wiener filter

Restoration of digital mammograms, as a pre-processing tool, using deconvolution procedures, is analysed. It implies, knowing Modulation Transfer Function (MTF) of the mammography device and the estimation of the mammogram’s noise. Wiener filter is used, as the most objective in mammograms restoration by deconvolution. Using MATLAB program the deconvolution procedures are conducted in two ways with different level of approximation. The first method approximates the noise/signal power ratio by a constant and the second method uses autocorrelation functions of the noise and signals. Abilities and limitations of the methods are analysed and checked by using the raw images of the bar-pattern due to better visualisation of the obtained results. The raw images are obtained at a Computed Radiography (CR) mammography device in Clinical Centre in Podgorica. It is found that quality of the restored image highly depends of knowledge of type and magnitude of noise. In the both methods spatial resolution of the restored images are improved, but much better in a case where autocorrelation functions of the noise and signal are used. This procedure is proposed as an objective pre-processing tool to put back imperfectness of mammography devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Science & Technology Review May/June 2008

This month's issue has the following articles: (1) Biomedical Technology Has a Home at Livermore--Commentary by Cherry A. Murray; (2) Shaping the Future of Aneurysm Treatments--Livermore foam devices may offer significant advantages for treating some forms of aneurysms; (3) Ring around a Stellar Shell: A Tale of Scientific Serendipity--Using a three-dimensional model, Livermore scientists have solved a long-standing puzzle of stellar evolution; and (4) On Assignment in Washington, DC--Livermore personnel in Washington, DC, support federal sponsors and become valuable assets to Laboratory programs.

59 BASIC BIOLOGICAL SCIENCES↗

A case study of technology transfer: Cardiology

Research advancements in cardiology instrumentation and techniques are summarized. Emphasis is placed upon the following techniques: (1) development of electrodes which show good skin compatibility and wearer comfort; (2) contourography - a real time display system for showing the results of EKGs; (3) detection of arteriosclerosis by digital computer processing of X-ray photos; (4) automated, noninvasive systems for blood pressure measurement; (5) ultrasonoscope - a noninvasive device for use in diagnosis of aortic, mitral, and tricuspid valve disease; and (6) rechargable cardiac pacemakers. The formation of a biomedical applications team which is an interdisciplinary team to bridge the gap between the developers and users of technology is described.

Schafer, G.↗

Summer institute in biomedical engineering, 1973

Design and development work is reported for an air filter, an infant weight scale, multiple electrode cardiography, a white noise hearing aid, and a tibial torsion correction device.

Deloatch, E. M.↗

NASA Tech Briefs, March 2008

Topics covered include: WRATS Integrated Data Acquisition System; Breadboard Signal Processor for Arraying DSN Antennas; Digital Receiver Phase Meter; Split-Block Waveguide Polarization Twist for 220 to 325 GHz; Nano-Multiplication-Region Avalanche Photodiodes and Arrays; Tailored Asymmetry for Enhanced Coupling to WGM Resonators; Disabling CNT Electronic Devices by Use of Electron Beams; Conical Bearingless Motor/Generators; Integrated Force Method for Indeterminate Structures; Carbon-Nanotube-Based Electrodes for Biomedical Applications; Compact Directional Microwave Antenna for Localized Heating; Using Hyperspectral Imagery to Identify Turfgrass Stresses; Shaping Diffraction-Grating Grooves to Optimize Efficiency; Low-Light-Shift Cesium Fountain without Mechanical Shutters; Magnetic Compensation for Second-Order Doppler Shift in LITS; Nanostructures Exploit Hybrid-Polariton Resonances; Microfluidics, Chromatography, and Atomic-Force Microscopy; Model of Image Artifacts from Dust Particles; Pattern-Recognition System for Approaching a Known Target; Orchestrator Telemetry Processing Pipeline; Scheme for Quantum Computing Immune to Decoherence; Spin-Stabilized Microsatellites with Solar Concentrators; Phase Calibration of Antenna Arrays Aimed at Spacecraft; Ring Bus Architecture for a Solid-State Recorder; and Image Compression Algorithm Altered to Improve Stereo Ranging.

Source record↗

A Year in Space: Early Results and Lessons Learned from the First Year-Long Expedition Aboard the International Space Station

Two ISS crewmembers recently completed the first year-long orbital stay in two decades. International cooperation was central to the success of Mikhail Kornienko from Russia and Scott Kelly from the United States. Their expedition leveraged current mission experience and capitalized on recent advances in health monitoring technology. This unique effort began in 2012 when the program managers of the ISS partner nations adopted two separate goals: greater multilateral cooperation to increase efficiency of inflight research and a year-long expedition to gain familiarity with in-flight durations approaching that required for a Mars mission. These goals were unified when a set of bilateral Russian and American human research investigations was assigned to the year-long mission, augmented by additional investigations from Europe and Japan. For example, Kelly was assigned 18 investigations (twice the complement on standard six-month missions) including two joint U.S.-Russian studies, and two Russian and two Japanese studies. The core set of American investigations was a repetition of six studies Kelly had done on his previous six-month ISS mission, to allow a direct comparison of physiological and behavioral responses of the longer and shorter durations in this single individual. The remainder of his assignments plus those of Kornienko were drawn from currently active national investigations documenting human adaptation to long-duration spaceflight factors or effectiveness of countermeasures against known deleterious adaptations. The two joint U.S.-Russian investigations were the flagship biomedical studies of the year-long expedition. The "Fluid Shifts" study collocated American research equipment alongside a Russian operational stressor device to document the pattern and impacts of the headward fluid shift long known to occur in weightlessness, including its role in ocular changes recently observed in some astronauts. The "Field Test" study investigated the ability of the astronaut and cosmonaut to perform rudimentary tasks requiring sensorimotor coordination immediately after landing to define human capabilities soon after landing on Mars after an extended transit. Both investigations were highly successful in large part to the thorough integration of the implementation processes of the two partners. Kelly's assignment as the one-year crewmember also provided a serendipitous opportunity for the "Twins Study" comparing changes in his body at the genetic level with those occurring on Earth in his identical twin brother Mark Kelly. Data analysis from this expedition will commence in earnest after frozen in-flight samples are delivered to Earth in May aboard a commercial cargo spacecraft. Detailed results are expected in early 2017. Preliminary results and implementation improvements will be reviewed in this presentation.

Charles, J. B.↗

CHARACTERIZING SURFACE LAYERS IN NITINOL USING X-RAY PHOTOELECTRON SPECTROSCOPY

Nitinol is a shape memory alloy whose properties allow for large reversible deformations and a return to its original geometry. This nickel-titanium (NiTi) alloy has become a material used widely in the biomedical fi eld as a stent to open up collapsed arteries. Both ambient and biological conditions cause surface oxidation in these devices which in turn change its biocompatibility. The thickness of oxidized layers can cause fractures in the material if too large and can allow for penetration if too thin. Depending on the type and abundance of the chemical species on or near the surface, highly toxic metal ions can leak into the body causing cell damage or even cell death. Thus, biocompatibility of such devices is crucial. By using highly surface sensitive x-ray photoelectron spectroscopy to probe the surface of these structures, it is possible to decipher both layer composition and layer thickness. Two samples, both of which were mechanically polished, were investigated. Of the two samples, one was then exposed to a phosphate buffered saline (PBS) solution to mimic the chemical properties of blood, while the other remained unexposed. Although both samples were found to have oxide layers of appropriate thickness (on the order of a few nm), it was found that the sample exposed to the saline solution had a slightly thicker oxide layer and more signifi cantly, a phosphate layer very near the surface suggesting toxic metal components are well contained within the sample. These are considerable indications of a biocompatible device.

Christopfel, R↗

Achieving tissue-level softness on stretchable electronics through a generalizable soft interlayer design

Soft and stretchable electronics have emerged as highly promising tools for biomedical diagnosis and biological studies, as they interface intimately with the human body and other biological systems. Most stretchable electronic materials and devices, however, still have Young’s moduli orders of magnitude higher than soft bio-tissues, which limit their conformability and long-term biocompatibility. Here, we present a design strategy of soft interlayer for allowing the use of existing stretchable materials of relatively high moduli to versatilely realize stretchable devices with ultralow tissue-level moduli. We have demonstrated stretchable transistor arrays and active-matrix circuits with moduli below 10 kPa—over two orders of magnitude lower than the current state of the art. Benefiting from the increased conformability to irregular and dynamic surfaces, the ultrasoft device created with the soft interlayer design realizes electrophysiological recording on an isolated heart with high adaptability, spatial stability, and minimal influence on ventricle pressure. In vivo biocompatibility tests also demonstrate the benefit of suppressing foreign-body responses for long-term implantation. With its general applicability to diverse materials and devices, this soft-interlayer design overcomes the material-level limitation for imparting tissue-level softness to a variety of bioelectronic devices.

42 ENGINEERING↗

Organocatalysis in ring opening copolymerization as a means of tailoring molecular weight dispersity and the subsequent impact on physical properties in 4D printable photopolymers

Vat photopolymerization 3D printing has traditionally relied on free radical crosslinking between alkenes to produce non-degradable parts, which may have limited use in the biomedical and clinical spaces. Photopolymer resins containing functionalized degradable polymers, specifically polyesters, are greatly interesting for 3D printing tissue scaffolds and medical devices. Unfortunately, most polyesters produced for these applications have been made using metal-containing catalysts, which are not without risk for medical applications. Organocatalysis is a viable alternative route to achieving the same types of polyesters. Here, ring opening copolymerization (ROCOP) of allyl and cyclohexene-containing polyesters is examined using bipyridine and a guanidine-containing catalyst. The role of the catalysts, initiators, and cocatalysts are examined for bulk, open air ROCOP reactions. Unlike previous efforts with organocatalysis, the examined catalysts here could be used to tailor the dispersity of the polyesters, with ~10 kDa polyesters with dispersity ranging from 1.3 to 2.5 examined for the impact on rheological and thermomechanical properties related to resin/part behavior. The bipyridine catalysts and a thiourea cocatalyst further are shown, through the introduction of new fluorescence emissions of the purified polyesters. As a result, this work demonstrates that tuning the dispersity of polyester photopolymers provides a direct method of tailoring physical and optical properties in 3D/4D printable materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for Impeding Degradation of Porous Silicon Structures

This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer chains were evaluated, Si mass loss from the nanovectors was slowed down, and the PEGylated structures were almost fully degraded within 18 24 hours in serum and within 48 hours in PBS. The most dramatic effect was observed for high MW PEGs 3,400 and 5,000 Da, which prominently inhibited the degradation of the systems, with complete degradation achieved only after four days. For these PEGs, during the early stages of the degradation, there was a lag period of little or no Si mass loss from the nanovector. The obtained profiles were in agreement with the erosion of the nanovector surface as observed by scanning electron microscopy.

Vilentchouk, Biana Godin↗