Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “better”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A U.S. scientific community review of carbon cycle science gaps and opportunities to better support earth system science and carbon management

Greenhouse gas (GHG) emissions continue to grow, while natural carbon reservoirs are becoming increasingly vulnerable to anthropogenic pressures, climate extremes, and disturbance. These changes are impacting humans, ecosystems, and natural resources worldwide. Tracking and mitigating GHG emissions require a pivot to operational monitoring of regional carbon flux and stock changes. The current GHG observing system is addressing needs at two distinct scales: 1) Local scale (< 1 km), related to anthropogenic point source emissions, and 2) global scales (> 1000 km), related to land and ocean carbon sinks. More focus on intermediate (10–1000 km) scales is needed to more effectively monitor progress in reducing carbon emissions, enhancing removals, and maintaining sinks. Representatives from carbon cycle biomass and flux communities across United States government agencies and academic institutions met in September 2024 to discuss the rationale and scientific context for more effectively implementing an operational system for GHG monitoring in support of urban and national carbon management needs. To guide development of this system, we propose a multi-tiered global spaceborne observing framework for carbon flux and stock, prioritizing: 1) frequent GHG partial columns for carbon emissions and removals; 2) continuous time series and data fusion of biomass from Lidar and Synthetic Aperture Radar (SAR) for carbon stocks, and 3) expanded coverage of tropical, high latitude, and oceanic regions to monitor carbon cycle tipping points and feedbacks. This system should be complemented by expanded surface and airborne networks for oceanic and terrestrial/aquatic ecosystems for calibration, ground truthing, and study of under-sampled regions.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the substantive effectiveness of SEA: Towards a better understanding

Evaluating the substantive effectiveness of strategic environmental assessment (SEA) is vital in order to know to what extent the tool fulfills its purposes and produces expected results. However, the studies that have evaluated the substantive effectiveness of SEA produce varying outcomes as regards the tool's contribution to decision-making and have used a variety of approaches to appraise its effectiveness. The aim of this article is to discuss the theoretical concept of SEA substantive effectiveness and to present a new approach that can be applied for evaluation studies. The SEA effectiveness evaluation framework that will be presented is composed of concepts of, and approaches to, SEA effectiveness derived from SEA literature and planning theory. Lessons for evaluation can be learned from planning theory in particular, given its long history of analyzing and understanding how sources of information and decisions affect (subsequent) decision-making. Key concepts of this new approach are 'conformance' and 'performance'. In addition, this article presents a systematic overview of process and context factors that can explain SEA effectiveness, derived from SEA literature. To illustrate the practical value of our framework for the assessment and understanding of substantive effectiveness of SEA, three Dutch SEA case studies are examined. The case studies have confirmed the usefulness of the SEA effectiveness assessment framework. The framework proved helpful in order to describe the cumulative influence of the three SEAs on decision-making and the ultimate plan. - Highlights: Black-Right-Pointing-Pointer A new framework to evaluate the substantive effectiveness of SEA is presented. Black-Right-Pointing-Pointer The framework is based on two key concepts: 'conformance' and 'performance.' Black-Right-Pointing-Pointer The practical applicability of the framework is demonstrated by three Dutch cases. Black-Right-Pointing-Pointer The framework allows for a more systematic understanding of SEA effectiveness. Black-Right-Pointing-Pointer Finally, this paper presents explanations for SEA effectiveness.

54 ENVIRONMENTAL SCIENCES↗

A review of smart building sensing system for better indoor environment control

Here this paper aims to provide a systemic review of how indoor sensors influence in managing optimal energy saving, thermal comfort, visual comfort, and indoor air quality in the built environment. The optimal management of energy saving and occupant comfort plays a vital role in the built environment because the occupant's productivity and health are highly influenced by indoor environmental quality. In order to do this, there must be a functional sensing system that connects the environment variables (e.g., temperature) with building environmental control systems such as the heating, ventilation, and air-conditioning system. This paper starts with an overview of the importance of energy saving and occupant comfort in the built environment. It then discusses sensors and their importance in the built environment and reviews the different types of sensors, which explains them in terms of how they influence the indoor built environment and occupant productivity. The paper further explores the application of sensors in the built environment and analyzes this in terms of energy saving, thermal comfort, visual comfort, and indoor air quality. Following this, the data analysis is discussed in terms of data, information, and knowledge accrued from the sensors. Lastly, the paper discusses the future challenges for the improvement of building indoor environmental quality and energy saving by the application of sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Ag and Zr solutes on dislocation emission from Σ11(332)[110] symmetric tilt grain boundaries in Cu: Bigger is not always better

Solute additions are commonly used to stabilize nanocrystalline materials against grain growth, and can simultaneously enhance the strength of the material by impeding dislocation emission from the grain boundaries. In this study we demonstrate using molecular dynamics (MD) simulations that the effect of solutes on dislocation nucleation depends on the distribution of solutes at the grain boundary, and can vary dramatically depending on the solute type. Solutes with a smaller positive size mismatch to the host can be more effective in suppressing dislocation emission from grain boundaries than others that have larger mismatch. In particular, although Ag solutes have a smaller misfit with Cu than Zr solutes, the effect of Ag on the dislocation nucleation from grain boundaries in Cu can be larger than the corresponding effect of Zr. Furthermore, these findings are relevant to the search for optimal solute additions, which can strengthen a nanocrytalline material by suppressing the nucleation of dislocation slip from grain boundaries, while stabilizing it against grain growth.

36 MATERIALS SCIENCE↗

Is Multibeam IMRT Better Than Standard Treatment for Patients With Left-Sided Breast Cancer?

Purpose: When treatment intent is to include breast and internal mammary lymph nodes (IMNs) in the clinical target volume (CTV), a significant volume of the heart may receive radiation, which may result in late morbidity. The value of conformal intensity-modulated radiation therapy (IMRT) to avoid heart dose was studied. Methods and Materials: Breast, IMNs, and normal tissues were contoured for 30 consecutive patients previously treated with RT after lumpectomy for left-sided breast cancer. Eleven-beam, conformal, inverse-planned IMRT plans were developed and compared with best standard plans. Conformity Index (CI), Homogeneity Index (HI), and doses to normal tissues were compared. Results: Intensity-modulated RT significantly improved (two-sided paired t test) HI (0.95 vs. 0.74), CI (0.91 vs. 0.48), volume of the heart receiving more than 30 Gy (V30-heart) (1.7% vs. 12.5%), and volume of lung receiving more than 20-Gy (V20-left lung) (17.1% vs. 26.6%), all p < 0.001. The mean Healthy Tissue Volume (HTV = CT set - PTV) dose was similar between IMRT and best standard plans (6.0 and 6.9 Gy, respectively), but IMRT increased the volume of normal tissues receiving low-dose RT: V5-right lung (13.7% vs. 2.0%), V5-right breast (29.2% vs. 7.9%), and V5-HTV (31.7% vs. 23.6%), all p < 0.001. IMRT plans were generated in less than 60 min and treatment delivered in approximately 20 min, suggesting that this technique is clinically applicable. Conclusions: IMRT significantly improved conformity and homogeneity for plans when the breast + IMNs were in the CTV. Heart and lung volume receiving high doses were decreased, but more healthy tissue received low doses. A simple algorithm based on amount of heart included in the standard plan showed limited ability to predict the benefit from IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Chemoradiation With Carboplatin-5-Fluorouracil Versus Cisplatin in Locally Advanced Oropharyngeal Cancers: Is More Always Better?

Purpose: The optimal chemotherapy regimen remains undefined in the treatment of locally advanced oropharyngeal cancer by concomitant chemoradiation. This article compares two platinum-based chemotherapy regimens. Methods and Materials: In this retrospective study, we reviewed all consecutive patients treated for Stage III or IVA-B oropharyngeal cancer using either a combination of carboplatin and 5-fluorouracil (5FU) every 3 weeks or high-dose cisplatin every 3 weeks concomitant with definitive radiation therapy. Results: A total of 200 patients were treated with carboplatin-5FU and 53 patients with cisplatin. Median potential follow-up was 43 months. The 3-year overall survival rates for carboplatin-5FU and cisplatin respectively were 79.1% and 74.9% (p = 0.628), the 3-year disease-free survival rates were 76.0% and 71.3% (p = 0.799), and the 3-year locoregional control rates were 88.4% and 94.2% (p = 0.244). Conclusions: We could not demonstrate differences between these two regimens, which both proved efficacious. Polychemotherapy and monochemotherapy therefore seem comparable in this retrospective analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Fecal Incontinence After High-Dose Radiotherapy for Prostate Cancer: Better Prediction Using Longitudinal Definitions

Purpose: To model late fecal incontinence after high-dose prostate cancer radiotherapy (RT) in patients accrued in the AIROPROS (prostate working group of the Italian Association of Radiation Oncology) 0102 trial using different endpoint definitions. Methods and Materials: The self-reported questionnaires (before RT, 1 month after RT, and every 6 months for {<=}3 years after RT) of 586 patients were available. The peak incontinence (P{sub I}NC) and two longitudinal definitions (chronic incontinence [C{sub I}NC], defined as the persistence of Grade 1 or greater incontinence after any Grade 2-3 event; and mean incontinence score [M{sub I}NC], defined as the average score during the 3-year period after RT) were considered. The correlation between the clinical/dosimetric parameters (including rectal dose-volume histograms) and P{sub I}NC (Grade 2 or greater), C{sub I}NC, and M{sub I}NC of {>=}1 were investigated using multivariate logistic analyses. Receiver operating characteristic curves and the area under the curve were used to assess the predictive value of the different multivariate models. Results: Of the 586 patients, 36 with a Grade 1 or greater incontinence score before RT were not included in the present analysis. Of the 550 included patients, 197 (35.8%) had at least one control with a Grade 1 or greater incontinence score (M{sub I}NC >0). Of these 197 patients, 37 (6.7%), 22 (4.0%), and 17 (3.1%) were scored as having P{sub I}NC, M{sub I}NC {>=}1, and C{sub I}NC, respectively. On multivariate analysis, Grade 2 or greater acute incontinence was the only predictor of P{sub I}NC (odds ratio [OR], 5.9; p = .0009). Grade 3 acute incontinence was predictive of C{sub I}NC (OR, 9.4; p = .02), and percentage of the rectal volume receiving >40 Gy of {>=}80% was predictive of a M{sub I}NC of {>=}1 (OR, 3.8; p = .008) and of C{sub I}NC (OR, 3.6; p = .03). Previous bowel disease, previous abdominal/pelvic surgery, and the use of antihypertensive (protective factor) correlated highly with both C{sub I}NC and M{sub I}NC {>=}1. The predictive values of the models for C{sub I}NC (area under the curve, 0.83) and M{sub I}NC {>=}1 (area under the curve, 0.73) were greater than the ones for P{sub I}NC (area under the curve, 0.62) and more reliable (p = .0001-.0003 against p = .02). Nomograms for the two longitudinal definitions were derived. Conclusions: The longitudinal definitions of fecal incontinence (C{sub I}NC and M{sub I}NC {>=}1) were helpful in accounting for both the persistence and the severity of the incontinence. A significant fraction of peak events was consequential to acute incontinence, and a longer duration of symptoms mainly depended on the rectal dose bath (percentage of rectal volume receiving >40 Gy), and pretreatment clinical factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?

Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleason score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the National Comprehensive Cancer Network classification. Conclusions: The PPC is an independent and powerful predictor of clinical outcomes of prostate cancer after RT. A risk model replacing T stage with the PPC to reduce subjectivity demonstrated potentially improved stratification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Hypofractionated Radiation Therapy: Injection of Hyaluronic Acid to Better Preserve The Rectal Wall

Purpose: The aim of this study was to evaluate the contribution of an injection of hyaluronic acid (HA) between the rectum and the prostate for reducing the dose to the rectal wall in a hypofractionated irradiation for prostate cancer. Methods and Materials: In a phase 2 study, 10 cc of HA was injected between the rectum and prostate. For 16 patients, the same intensity modulated radiation therapy plan (62 Gy in 20 fractions) was optimized on 2 computed tomography scans: CT1 (before injection) and CT2 (after injection). Rectal parameters were compared: dose to 2.5 cc (D2.5), 5 cc (D5), 10 cc (D10), 15 cc (D15), and 20 cc (D20) of rectal wall and volume of rectum covered by the 90% isodose line (V90), 80% (V80), 70% (V70), 60% (V60), and 50% (V50). Results: The mean V90, V80, V70, V60, and V50 values were reduced by 73.8% (P<.0001), 55.7% (P=.0003), 43.0% (P=.007), 34% (P=.002), and 25% (P=.036), respectively. The average values of D2.5, D5, D10, D15, and D20 were reduced by 8.5 Gy (P<.0001), 12.3 Gy (P<.0001), 8.4 Gy (P=.005), 3.7 Gy (P=.026), and 1.2 Gy (P=.25), respectively. Conclusions: The injection of HA significantly limited radiation doses to the rectal wall.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Field Size and Length of Plantar Spur on Treatment Outcome in Radiation Therapy of Plantar Fasciitis: The Bigger the Better?

Purpose: Radiation therapy is well established in the treatment of painful plantar fasciitis or heel spur. A retrospective analysis was conducted to investigate the effect of field definition on treatment outcome and to determine the impact of factors potentially involved. Methods and Materials: A review of treatment data of 250 patients (285 heels) with a mean follow-up time of 11 months showed that complete symptom remission occurred in 38%, partial remission in 32%, and no change in 19% (11% were lost to follow-up). Variables such as radiologic evidence of plantar spurs, their length, radiation dose, field size, age, sex, and onset of pain before administration of radiation therapy were investigated in univariate and multivariate regression analyses. Results: Treatment response depended upon age >53 years, length of heel spur ≤6.5 mm (or no radiologic evidence of a heel spur), and onset of pain <12 months before radiation therapy. Patients with these clinical prerequisites stood a 93% chance of clinical response. Without these prerequisites, only 49% showed any impact. No influence of field size on treatment outcome became evident. Conclusion: Patients with short plantar heel spurs benefit from radiation therapy equally well as patients without any radiologic evidence. Moreover, smaller field sizes have the same positive effect as commonly used large field definitions covering the entire calcaneal bone. This leads to a recommendation of a considerable reduction of field size in future clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Better Efficacy of Synchrotron Spatially Microfractionated Radiation Therapy Than Uniform Radiation Therapy on Glioma

Purpose: Synchrotron microbeam radiation therapy (MRT) is based on the spatial fractionation of the incident, highly focused synchrotron beam into arrays of parallel microbeams, typically a few tens of microns wide and depositing several hundred grays. This irradiation modality was shown to have a high therapeutic impact on tumors, especially in intracranial locations. However, mechanisms responsible for such a property are not fully understood. Methods and Materials: Thanks to recent progress in dosimetry, we compared the effect of MRT and synchrotron broad beam (BB) radiation therapy delivered at comparable doses (equivalent to MRT valley dose) on tumor growth control and on classical radiobiological functions by histologic evaluation and/or transcriptomic analysis. Results: MRT significantly improved survival of rats bearing 9L intracranial glioma compared with BB radiation therapy delivered at a comparable dose (P<.001); the efficacy of MRT and BB radiation therapy was similar when the MRT dose was half that of BB. The greater efficacy of MRT was not correlated with a difference in cell proliferation (Mki67 and proliferating cell nuclear antigen) or in transcriptomic stimulation of angiogenesis (vascular endothelial growth factor A or tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 2) but was correlated with a higher cell death rate (factor for apoptosis signals) and higher recruitment of macrophages (tyrosine kinase with immunoglobulin-like and epidermal growth factor-like domains 1 and CD68 transcripts) a few days after MRT. Conclusions: These results show the superiority of MRT over BB radiation therapy when applied at comparable doses, suggesting that spatial fractionation is responsible for a specific and particularly efficient tissue response. The higher induction of cell death and immune cell activation in brain tumors treated by MRT may be involved in such responses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗