Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Pulse Generation Framework with Augmented Program-aware Basis Gates and Criticality Analysis

Near-term intermediate scale quantum (NISQ) de- vices are subject to considerable noise and short coherence time. Consequently, it is critical to minimize circuit execution latency. Traditionally, each basis gate of a transpiled circuit is decoded into a fixed episode of the device control pulses. Recently, people started to investigate merged pulse generation for customized gates through quantum optimal control (QOC). However, existing QOC approaches face the challenges of (i) restricted search space due to prohibitive compilation overhead; (ii) suboptimal end-to-end performance due to aggressive local optimization and falsely introduced dependency among the customized gates; (iii) inadequate adaptivity towards system calibration, which is critical for NISQ devices. In this work, we propose PAQOC, a novel QOC framework that can (i) automatically detect frequently encountered gate patterns in the logical circuit by modeling the problem as a subgraph mining process and reuse these patterns to enable much larger search space exploration (i.e., program aware); (ii) systemically construct customized gate-set based on the impact to the overall program latency (i.e., criticality-aware); and (iii) quickly adapt to system re-calibration thanks to the small-scale pattern-based gate generation (i.e., adaptivity-aware). PAQOC achieves a good tradeoff between circuit performance and compilation time, allowing fully automatic, single stop, ad- hoc customized pulse generation for more efficient execution of user programs on NISQ devices. Evaluations using fifteen applications show that PAQOC can achieve on average 1.95× speedup of the circuit latency and achieve on average 36.7% reduction in compilation overhead. With PAQOC, circuits can run faster with reduced noise, allowing deeper circuits to be tested within the coherence time of present NISQ platforms.

Chen, Yanhao↗

Magnitude calibration of a fixed head star tracker using Astro-1 flight data

The Astro-1 UV astronomy mission was hampered by the failures of the automatic star acquisition procedure. The acquisition procedure depended on the Instrument Pointing Subsystem's Fixed Head Star Trackers (FHST) to acquire, track and identify guidestars of known visual magnitude. During the Astro-1 mission it was suspected that the star magnitudes measured by the FHST were much lower than predicted. A postflight investigation of the Astro-1 flight data confirmed and quantified this suspicion. Star magnitude calibration curves computed from the flight data depict the variance from the preflight calibration curves. These results are helping engineers to plan improvements to the acquisition procedure for the upcoming Astro-2 mission.

Rakoczy, John M.↗

Rapid and precise measurement of flatband voltage

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.

Li, S. P.↗

Systems Analyze Water Quality in Real Time

A water analyzer developed under Small Business Innovation Research (SBIR) contracts with Kennedy Space Center now monitors treatment processes at water and wastewater facilities around the world. Originally designed to provide real-time detection of nutrient levels in hydroponic solutions for growing plants in space, the ChemScan analyzer, produced by ASA Analytics Inc., of Waukesha, Wisconsin, utilizes spectrometry and chemometric algorithms to automatically analyze multiple parameters in the water treatment process with little need for maintenance, calibration, or operator intervention. The company has experienced a compound annual growth rate of 40 percent over its 15-year history as a direct result of the technology's success.

Source record↗

TESS Data Release Notes:Reprocessing of Sectors 14–19, DR30 & DR33

TESS data release 30 (DR30) provides reprocessed data products of Sector 14 to 19. The updated data products were generated using version 4.0 of the science processing pipeline and conform to the final set of data anomaly flags defined over the last two years of TESS data analysis and pipeline development. Data release 33 (DR33) corresponds to a multisector search for transiting planets in the same reprocessed data. A detailed description of the changes in the data products in DR30 and DR33 is discussed in§2, and a brief list of changes is summarized here: The timestamps for 2 minute cadence and FFI data are more accurate. The differences between reprocessed data and previous data releases are less than 2.0 seconds in all cases. Photometric apertures were increased in size for targets with T mag<11. Three new Data Anomaly Flags were added to mitigate the effects of scattered light:–Cadences with strong scattered light signals or saturation effects that corrupt the calibration data are flagged and removed from analysis (bit 15, value 16384, “Bad Calibration Exclude”).–Scattered light data anomaly flags are customized for each target, and flagged automatically based on the local background level (bit 13, value 4096, ”Scattered light flag”).–Cadences with insufficient targets to derive cotrending basis vectors are flagged and the PDCSAP FLUX light curves are set to NULL at these times (bit 16, value 32768, “Insufficient Targets for Error Correction Exclude”). The planet search of the reprocessed light curves produced a different set of TCEs from the original processed data. Although there is a high degree of overlap between the original and reprocessed data (∼83% of targets produced TCEs in common), new TCEs were produced in DR30 and not every TCE from previous data releases was recovered. The same is true of the multisector search results from DR33 compared to DR28

TESS'↗

Infrared Sky Imager (IRSI) Instrument Handbook

The Infrared Sky Imager (IRSI) deployed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility is a Solmirus Corp. All Sky Infrared Visible Analyzer. The IRSI is an automatic, continuously operating, digital imaging and software system designed to capture hemispheric sky images and provide time series retrievals of fractional sky cover during both the day and night. The instrument provides diurnal, radiometrically calibrated sky imagery in the mid-infrared atmospheric window and imagery in the visible wavelengths for cloud retrievals during daylight hours. The software automatically identifies cloudy and clear regions at user-defined intervals and calculates fractional sky cover, providing a real-time display of sky conditions.

54 ENVIRONMENTAL SCIENCES↗

Advanced Signal Conditioners for Data-Acquisition Systems

Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

Lucena, Angel↗

An integrated approach to monitoring the calibration stability of operational dual-polarization radars

The stability of weather radar calibration is a mandatory aspect for quantitative applications, such as rainfall estimation, short-term weather prediction and initialization of numerical atmospheric and hydrological models. Over the years, calibration monitoring techniques based on external sources have been developed, specifically calibration using the Sun and calibration based on ground clutter returns. In this paper, these two techniques are integrated and complemented with a self-consistency procedure and an intercalibration technique. The aim of the integrated approach is to implement a robust method for online monitoring, able to detect significant changes in the radar calibration. The physical consistency of polarimetric radar observables is exploited using the self-consistency approach, based on the expected correspondence between dual-polarization power and phase measurements in rain. This technique allows a reference absolute value to be provided for the radar calibration, from which eventual deviations may be detected using the other procedures. In particular, the ground clutter calibration is implemented on both polarization channels (horizontal and vertical) for each radar scan, allowing the polarimetric variables to be monitored and hardware failures to promptly be recognized. The Sun calibration allows monitoring the calibration and sensitivity of the radar receiver, in addition to the antenna pointing accuracy. It is applied using observations collected during the standard operational scans but requires long integration times (several days) in order to accumulate a sufficient amount of useful data. Finally, an intercalibration technique is developed and performed to compare colocated measurements collected in rain by two radars in overlapping regions. The integrated approach is performed on the C-band weather radar network in northwestern Italy, during July&ndash;October 2014. The set of methods considered appears suitable to establish an online tool to monitor the stability of the radar calibration with an accuracy of about 2 dB. In conclusion, this is considered adequate to automatically detect any unexpected change in the radar system requiring further data analysis or on-site measurements.

54 ENVIRONMENTAL SCIENCES↗

Fast calibration of gas flowmeters

Digital unit automates calibration sequence using calculator IC and programmable read-only memory to solve calibration equations. Infrared sensors start and stop calibration sequence. Instrument calibrates mass flowmeters or rotameters where flow measurement is based on mass or volume. This automatic control reduces operator time by 80 percent. Solid-state components are very reliable, and digital character allows system accuracy to be determined primarily by accuracy of transducers.

Lisle, R. V.↗

Automatic analysis of stereoscopic GOES/GOES and GOES/NOAA image pairs for measurement of hurricane cloud top height and structure

Results are presented from a baseline study using an synthetic stereo image pair to test the Automatic Stereo Analysis (ASA) technique for reproducing cloud top structure. The ASA analysis, display, and calibration procedures are described. A GEO/LEO (GOES/NOAA AVHRR) image pair from Hurrican Allen in 1980 is used to illustrate the results that can be obtained using the ASA technique. Also, results are presented from applying the ASA technique to a GEO/GEO (GOES/GOES) image pair of Hurricane Gilbert in 1988.

Hasler, A. F.↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Control Of Length Of Welding Arc

Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

Iceland, William F.↗

A non-cooperative meta-modeling game for automated third-party calibrating, validating and falsifying constitutive laws with parallelized adversarial attacks

The evaluation of constitutive models, especially for high-risk and high-regret engineering applications, requires efficient and rigorous third-party calibration, validation and falsification. While there are numerous efforts to develop paradigms and standard procedures to validate models, difficulties may arise due to the sequential, manual, and often biased nature of the commonly adopted calibration and validation processes, thus slowing down data collections, hampering the progress towards discovering new physics, increasing expenses and possibly leading to misinterpretations of the credibility and application ranges of proposed models. This work attempts to introduce concepts from game theory and machine learning techniques to overcome many of these existing difficulties. Here, we introduce an automated meta-modeling game where two competing AI agents systematically generate experimental data to calibrate a given constitutive model and to explore its weakness such that the experiment design and model robustness can be improved through competitions. The two agents automatically search for the Nash equilibrium of the meta-modeling game in an adversarial reinforcement learning framework without human intervention. In particular, a protagonist agent seeks to find the more effective ways to generate data for model calibrations, while an adversary agent tries to find the most devastating test scenarios that expose the weaknesses of the constitutive model calibrated by the protagonist. By capturing all possible design options of the laboratory experiments into a single decision tree, we recast the design of experiments as a game of combinatorial moves that can be resolved through deep reinforcement learning by the two competing players. Our adversarial framework emulates idealized scientific collaborations and competitions among researchers to achieve a better understanding of the application range of the learned material laws and prevent misinterpretations caused by conventional AI-based third-party validation. Numerical examples are given to demonstrate the wide applicability of the proposed meta-modeling game with adversarial attacks on both human-crafted constitutive models and machine learning models.

97 MATHEMATICS AND COMPUTING↗

The least squares process of MEDIA for computing DRVID calibration polynomials

A process is described and evaluated for computing a least squares polynomial approximation of data points in which the optimum degree of the polynomial is automatically determined. An iterative smoothing technique is used to replace every point with the value taken on by a moving least squares polynomial computed from a subset of points centered at the point to be replaced. The optimum degree of the resulting polynomial approximation is determined by analyzing the finite differences of each successive set of smoothed points. To evaluate the process, both artificially constructed data and actual Mariner Mars 1971 (MM'71) tracking data are used. This process was incorporated into a transmission media calibration computer program (MEDIA), which calibrates radiometric data to overcome the effects on the tracking signal of charged particle media. MEDIA was used in support of MM'71.

Leavitt, R. K.↗

Instrumentation for measuring aircraft noise and sonic boom

Improved instrumentation suitable for measuring aircraft noise and sonic booms is described. An electric current proportional to the sound pressure level at a condenser microphone is produced and transmitted over a cable and amplified by a zero drive amplifier. The converter consists of a local oscillator, a dual-gate field-effect transistor mixer, and a voltage regulator/impedance translator. The improvements include automatic tuning compensation against changes in static microphone capacitance and means for providing a remote electrical calibration capability.

Zuckerwar, A. J.↗

Carbon monoxide measurement in the global atmospheric sampling program

The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

Dudzinski, T. J.↗

System Measures Loads In Bolts

Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

Allison, Sidney G.↗