Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuation correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

BNF C-band Scanning ARM Precipitation Radar 2nd Generation (CSAPR-2) Extracted Radar Columns and In-Situ Sensors (RadCLss)

Corrected Moments in Antenna Coordinates (CMAC) calculates quantitative precipitation estimates (QPE) from empirical relationships based on equivalent radar reflectivity factor, specific differ- ential phase, and specific attenuation. To evaluate these empirical relationships, the Extracted Radar Columns and In-Situ Sensors (RADclss) product was developed. Utilizing Py-ART, RAD- clss extracts CMAC radar columns above various ARM and partner locations. These columns are then spatiotemporally synced with in-situ observations at the surface utilizing the Atmospheric data Community Toolkit (ACT; Theisen et al. 2025), allowing direct comparison of radar parameters with rain gauges and laser disdrometers for further investigation.

bankhead↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

Full-Scale Turbofan-Engine Turbine-Transfer Function Determination Using Three Internal Sensors

Existing NASA/Honeywell EVNERT full-scale static engine test data is analyzed by using source-separation techniques in order to determine the turbine transfer of the currently sub-dominant combustor noise. The results are used to assess the combustor-noise prediction capability of the Aircraft Noise Prediction Program (ANOPP). Time-series data from three sensors internal to the Honeywell TECH977 research engine is used in the analysis. The true combustor-noise turbine-transfer function is educed by utilizing a new three-signal approach. The resulting narrowband gain factors are compared with the corresponding constant values obtained from two empirical acoustic-turbine-loss formulas. It is found that a simplified Pratt & Whitney formula agrees better with the experimental results for frequencies of practical importance. The 130 deg downstream-direction far-field 1/3-octave sound-pressure levels (SPL) results of Hultgren & Miles are reexamined using a post-correction of their ANOPP predictions for both the total noise signature and the combustion-noise component. It is found that replacing the standard ANOPP turbine-attenuation function for combustion noise with the simplified Pratt & Whitney formula clearly improves the predictions. It is recommended that the GECOR combustion-noise module in ANOPP be updated to allow for a user-selectable switch between the current transmission-loss model and the simplified Pratt & Whitney formula. The NASA Fundamental Aeronautics Program has the principal objective of overcoming today's national challenges in air transportation. The Subsonic Fixed Wing Project's Reduce-Perceived-Noise Technical Challenge aims to develop concepts and technologies to dramatically reduce the perceived aircraft noise outside of airport boundaries. The reduction of aircraft noise is critical to enabling the anticipated large increase in future air traffic.

Hultgren, Lennart S.↗

Bringing discrete-time Langevin splitting methods into agreement with thermodynamics

In light of the recently published complete set of statistically correct Grønbech–Jensen (GJ) methods for discrete-time thermodynamics, we revise a differential operator splitting method for the Langevin equation in order to comply with the basic GJ thermodynamic sampling features, namely, the Boltzmann distribution and Einstein diffusion, in linear systems. This revision, which is based on the introduction of time scaling along with flexibility of a discrete-time velocity attenuation parameter, provides a direct link between the ABO splitting formalism and the GJ methods. This link brings about the conclusion that any GJ method has at least weak second order accuracy in the applied time step. It further helps identify a novel half-step velocity, which simultaneously produces both correct kinetic statistics and correct transport measures for any of the statistically sound GJ methods. Explicit algorithmic expressions are given for the integration of the new half-step velocity into the GJ set of methods. Finally, numerical simulations, including quantum-based molecular dynamics (QMD) using the QMD suite Los Alamos Transferable Tight-Binding for Energetics, highlight the discussed properties of the algorithms as well as exhibit the direct application of robust, time-step-independent stochastic integrators to QMD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wave attenuation in the marginal ice zone during LIMEX

The effect of ice cover on ocean-wave attenuation is investigated for waves under flexure in the marginal ice zone (MIZ) with SAR image spectra and the results of models. Directional wavenumber spectra are taken from the SAR image data, and the wave-attenuation rate is evaluated with SAR image spectra and by means of the model by Liu and Mollo-Christensen (1988). Eddy viscosity is described by means of dimensional analysis as a function of ice roughness and wave-induced velocity, and comparisons are made with the remotely sensed data. The model corrects the open-water model by introducing the effects of a continuous ice sheet, and turbulent eddy viscosity is shown to depend on ice thickness, floe sizes, significant wave height, and wave period. SAR and wave-buoy data support the trends described in the model results, and a characteristic rollover is noted in the model and experimental wave-attenuation rates at high wavenumbers.

Liu, Antony K.↗

CALIPSO IIR Version 2 Level 1b Calibrated Radiances: Analysis and Reduction of Residual Biases in the Northern Hemisphere

Version 2 of the Level 1b calibrated radiances of the Imaging Infrared Radiometer (IIR) on board the Cloud-Aerosol Lidar and Infrared Satellite Observation (CALIPSO) satellite has been released recently. This new version incorporates corrections of small but systematic seasonal calibration biases previously revealed in Version 1 data products mostly north of 30° N. These biases – of different amplitudes in the three IIR channels 8.65 µm (IIR1), 10.6 µm (IIR2), and 12.05 µm (IIR3) – were made apparent by a striping effect in images of IIR inter-channel brightness temperature differences (BTDs) and through seasonal warm biases of nighttime IIR brightness temperatures in the 30–60° N latitude range. The latter were highlighted through observed and simulated comparisons with similar channels of the Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Aqua spacecraft. To characterize the calibration biases affecting Version 1 data, a semi-empirical approach is developed, which is based on the in-depth analysis of the IIR internal calibration procedure in conjunction with observations such as statistical comparisons with similar MODIS/Aqua channels. Two types of calibration biases are revealed: an equalization bias affecting part of the individual IIR images and a global bias affecting the radiometric level of each image. These biases are observed only when the temperature of the instrument increases, and they are found to be functions of elapsed time since night-to-day transition, regardless of the season. Correction coefficients of Version 1 radiances could thus be defined and implemented in the Version 2 code. As a result, the striping effect seen in Version 1 is significantly attenuated in Version 2. Systematic discrepancies between nighttime and daytime IIR–MODIS BTDs in the 30–60° N latitude range in summer are reduced from 0.2 K in Version 1 to 0.1 K in Version 2 for IIR1–MODIS29. For IIR2–MODIS31 and IIR3–MODIS32, they are reduced from 0.4 K to close to zero, except for IIR3–MODIS32 in June, where the night-minus-day difference is around −0.1 K.

Garnier, Anne↗

Measurement of the production cross section of 31 GeV/ c protons on carbon via beam attenuation in a 90-cm-long target

The production cross section of 30.92 GeV/c protons on carbon is measured by the NA61/SHINE spectrometer at the CERN Super Proton Synchrotron by means of beam attenuation in a copy (replica) of the 90-cm-long target of the T2K neutrino oscillation experiment. The employed method for direct production cross-section estimation minimizes model corrections for elastic and quasielastic interactions. The obtained production cross section is $σ_{\text{prod}}$ = 227.6 ± 0.8(stat)$_{\text{-3.2}}^{\text{+1.9}}$(sys) – 0.8(mod) mb. It is in agreement with previous NA61/SHINE results obtained with a thin carbon target, while providing improved precision with a total fractional uncertainty of less than 2%. This direct measurement will reduce the uncertainty of the T2K neutrino flux prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-diagnosis of model suitability for continuous measurements of stream-dissolved organic carbon derived from in situ UV–visible spectroscopy

Application of high-frequency monitoring of dissolved organic carbon (DOC) is difficult in instances where training datasets are challenging to develop (e.g., remote locations) and the relationship between optical features and DOC concentration changes due to environmental or landscape shifts (e.g., climate or land-use change). We developed and compared three partial least squares (PLS) models using in situ water level measurements, conductivity, and UV–Vis spectral attenuation to predict DOC. Two site-specific models were developed using data from a hillslope-dominated forest or a low-relief wetland-pond-dominated stream catchment. The third model, using data from both sites, exhibited the best performance (DOC range = 4–15.5 mg C L −1 , mean = 8.38 mg C L −1 , training RMSE = 0.34 mg C L −1 , internal validation RMSE = 0.50 mg C L −1 , external validation RMSE = 2.43 mg C L −1 ). We further demonstrate using PLS model statistics to monitor performance and elucidate when and how models should be updated. These statistics, Hotelling's T 2 and squared prediction errors, are useful consistency checks for the predictions made and detect underlying inconsistencies that, if undetected, can reduce the robustness of DOC prediction. For example, via the T 2 statistic, we identified the summer–autumn transition as a period when DOC composition differed from what was represented in the training dataset. We also determined that elevated SUVA 254 values contributed to the overall bias observed in predictions made during the subsequent year as part of the external validation. This enabled the application of a bias correction that reduced the RMSE from 2.43 to 0.89 mg C L −1 . The method presented here could be applied to future monitoring programs enabling model updates to monitor DOC fluxes accurately from optical datasets (e.g., attenuance or fluorescence) in the face of developing datasets in remote locations or environmental change. In conclusion, implementation of this approach may also identify possible regime shifts or landscape and hydrologic change associated with climate and other environmental changes relevant to terrestrial to aquatic fluxes.

UV-VIS spectroscopy↗

A Pn magnitude scale m b ( Pn ) for earthquakes along the equatorial Mid-Atlantic Ridge

We developed a short-period Pn magnitude scale m b (Pn) for earthquakes along the equatorial Mid-Atlantic Ridge. Due to low signal-to-noise ratios, teleseismic body wave magnitude and long-period surface wave magnitude cannot be confidently determined for small earthquakes of m b < 4. Local magnitude scales are also not useful for these events because the oceanic environment does not allow the propagation of crustal phases. However, regional high-frequency Pn waves from these small- to moderate-size (m b 3–6) earthquakes are well recorded in the equatorial Atlantic region and can be used to assign magnitudes. We measured over 2041 Pn peak amplitudes on vertical records from about 21 stations in northeastern Brazil and 11 stations in western Africa in the distance range of 700–3700 km. We analysed data from 189 events from the global centroid moment tensor catalogue to tie our m b (Pn) scale to M w so that seismic moments can be readily estimated. Pn arrivals show apparent group velocity between 7.9 km s –1 at short ranges (~1000 km) and up to 9.1 km s –1 at 3500 km. The measured peak amplitudes have a frequency between 0.8 and 3 Hz at 1000–1800 km, but at greater distances, 1800–3700 km, they show a remarkably consistent frequency of about 0.8 Hz. The peak amplitude attenuates at a higher rate at short distances (~0.65 magnitude units between 700 and 2000 km) but attenuates at a lower rate at long distances (~0.35 magnitude units between 2000 and 3700 km). The low rate of amplitude decay with distance and nearly constant frequency content of the peak amplitudes suggest that Pn waves propagate efficiently in the lower part of the upper mantle in the equatorial Atlantic Ocean basins. Furthermore, these are important attributes of oceanic Pn waves that can be used to assign magnitude for small- to moderate-size earthquakes in the equatorial mid-Atlantic region. The estimated station corrections correlate well with upper mantle low-velocity anomalies, especially in Brazil.

58 GEOSCIENCES↗

Method for beam hardening correction in quantitative computed X-ray tomography

Each voxel is assumed to contain exactly two distinct materials, with the volume fraction of each material being iteratively calculated. According to the method, the spectrum of the X-ray beam must be known, and the attenuation spectra of the materials in the object must be known, and be monotonically decreasing with increasing X-ray photon energy. Then, a volume fraction is estimated for the voxel, and the spectrum is iteratively calculated.

Yan, Chye Hwang↗

Estimation of the Attenuation Caused by Power Line Towers on an E1-HEMP Induced Excitation

In a transmission line, the coupling between a line and a tower above ground is evaluated when the excitation is an E1 high-altitude electromagnetic pulse (HEMP). The model focuses on capturing correctly the effect of the coupling on the peak of the HEMP induced current that propagates along the line. This assessment is necessary to accurately estimate the effect of the excitation on the systems and components of the power grid. This analysis is a step towards a quantitative evaluation of HEMP excitation on the power grid. The results obtained indicate that the effect can be significant, especially for lines heights of 20 meters or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supply Warehouse#3, SWMU 088 Operations, Maintenance, and Monitoring Report Kennedy Space Center, Florida

This document presents the findings, observations, and results associated with Operations, Maintenance, and Monitoring (OM&M) activities of Corrective Measures Implementation (CMI) activities conducted at Supply Warehouse #3 (SW3) located at John F. Kennedy Space Center (KSC), Florida from October 8, 2015, to September 12, 2016, and performance monitoring results for semi-annual sampling events conducted in March and September 2016. The primary objective of SW3 CMI is to actively decrease concentrations of trichloroethene (TCE) and vinyl chloride (VC) to less than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs), and the secondary objective is to reduce TCE, cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE), 1,1-dichloroethene (11DCE), and VC concentrations to less than FDEP Groundwater Cleanup Target Levels (GCTLs). The SW3 facility has been designated Solid Waste Management Unit (SWMU) 088 under KSC's Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Based on the results to date, the SW3 air sparging (AS) system is operating at or below the performance criteria as presented in the 2008 SW3 Corrective Measures Implementation (CMI) Work Plan and 2009 and 2012 CMI Work Plan Addenda. Since the start of AS system operations on December 19, 2012, through the September 2016 groundwater sampling event, TCE concentrations have decreased to less than the GCTL in all wells within the Active Remediation Zone (ARZ), and VC results remain less than NADC but greater than GCTL. Based on these results, team consensus was reached at the October 2016 KSC Remediation Team (KSCRT) meeting to continue AS system operations and semi-annual performance monitoring of volatile organic compounds in March 2017 at ten monitoring wells at select locations, and in September 2017 at four monitoring wells at select locations to reduce VC concentrations to below GCTL. Additionally, surface water samples will be collected at locations SW0001, SW0002, and SW0003 during both the March and September 2017 events. Team consensus was also reached at the October 2017 KSCRT meeting to continue with operation and maintenance (O&M) of the AS system at SW3.

REPORT↗

Radar Autofocus Algorithm Incorporating a priori Terrain Knowledge for Correction of Mars’ Ionospheric Distortion in MARSIS Observations

Low-frequency subsurface radar observations of Mars’ polar ice deposits by MARSIS (Mars Advanced Radar for Subsurface and Ionosphere Sounding) are heavily impacted by the electron content of Mars’ ionosphere. The resulting ionospheric distortion can be represented as attenuation and bulk delay, in addition to higher-order frequency dispersion effects. Baseline, uncorrected images are often unusable when the solar zenith angle is less than 90◦ (day side). In this work, a radar autofocus algorithm is developed that estimates and inverts ionospheric distortion, producing a focused radargram of the ice deposit subsurface. Previously published autofocus algorithms have sought to maximize peak-to-noise contrast, which may yield sub-optimal results for complex terrain. Instead, a maximum likelihood approach is developed that incorporates simulated surface clutter returns for the current spacecraft position, based on the Mars Orbiter Laser Altimeter (MOLA) elevation model of the Martian surface. An ancillary product is a surface-only clutter simulation for each orbit, which is necessary to identify true subsurface features.

McMichael, Joseph G.↗

Fast Light Optical Gyroscopes

Next-generation space missions are currently constrained by existing spacecraft navigation systems which are not fully autonomous. These systems suffer from accumulated dead-reckoning errors and must therefore rely on periodic corrections provided by supplementary technologies that depend on line-of-sight signals from Earth, satellites, or other celestial bodies for absolute attitude and position determination, which can be spoofed, incorrectly identified, occluded, obscured, attenuated, or insufficiently available. These dead-reckoning errors originate in the ring laser gyros themselves, which constitute inertial measurement units. Increasing the time for standalone spacecraft navigation therefore requires fundamental improvements in gyroscope technologies. One promising solution to enhance gyro sensitivity is to place an anomalous dispersion or fast light material inside the gyro cavity. The fast light essentially provides a positive feedback to the gyro response, resulting in a larger measured beat frequency for a given rotation rate as shown in figure 1. Game Changing Development has been investing in this idea through the Fast Light Optical Gyros (FLOG) project, a collaborative effort which began in FY 2013 between NASA Marshall Space Flight Center (MSFC), the U.S. Army Aviation and Missile Research, Development, and Engineering Center (AMRDEC), and Northwestern University. MSFC and AMRDEC are working on the development of a passive FLOG (PFLOG), while Northwestern is developing an active FLOG (AFLOG). The project has demonstrated new benchmarks in the state of the art for scale factor sensitivity enhancement. Recent results show cavity scale factor enhancements of approx.100 for passive cavities.

Smith, David D.↗

In-Flight Calibration of Hitomi Soft X-Ray Spectrometer (3) Effective Area

We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) on board the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for artifacts when observing high count rate sources with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5–20 keV band, which we modeled with a single power-law continuum attenuated by interstellar extinction. We evaluated the systematic uncertainty of the spectral parameters by various calibration items. In the 2–12 keV band, the SXS result is consistent with the literature values in flux (2.20 ± 0.08 × 10(exp −8) erg s(exp-1) cm(exp −2) with a 1 σ statistical uncertainty) but is softer in the power-law index (2.19 ± 0.11). The discrepancy is attributable to the systematic uncertainty of about +6%/−7% and +2%/−5% respectively for the flux and the power-law index. The softer spectrum is affected primarily by the systematic uncertainty of the Dewar gate valve transmission and the event screening.

Tsujimoto, Masahiro↗

Applied Science Investigations to Facilitate Closure of the F-Area and H-Area Seepage Basins

This report provides a roadmap of applied science studies that will facilitate reaching long term monitoring end state corrective actions for groundwater contamination at the F-Area Seepage Basins and the H-Area Seepage Basins at the Savannah River Site in Aiken, SC. The F-Area and H-Area Seepage Basins are waste units on the Savannah River Site in Aiken, SC at which low-level radioactive solutions were disposed into unlined basins, resulting in groundwater contamination. The current contaminants of interest in the groundwater are tritium, iodine-129, strontium-90, uranium isotopes and nitrate. Remediation at both sites has continued since 1988, consisting of closure and capping of the basins, operation of a groundwater pump-and-treat system from 1997 to 2004, and replacement of this system with a comprehensive in situ attenuation-based remedy. This report was requested by the U.S. Department of Energy - Office of Environmental Management in consultation with the Savannah River National Laboratory and Savannah River Nuclear Solutions - Area Completions Projects to provide a scientific basis for proactively addressing groundwater issues that may need to be resolved prior to final corrective actions at the F-Area and H-Area Seepage Basins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concentration measurements in an axisymmetric jet using laser-induced fluorescence

Errors associated with the use of an image processing technique to correct images of an axisymmetric jet produced by laser-induced fluorescence are analyzed. In particular, attention is given to errors related to the alignment of the optical system, spreading of the laser light sheet, laser light attenuation due to light absorption by the fluorescent dye, and solubility effects. Although the above effects are negligible in the case of a small low-concentration jet, they are not negligible in all fluorescent dye experiments.

Shoe, B.↗

Airborne HSRL Assessment of CALIOP Aerosol Extinction Retrievals Constrained by Column AOD

Current operational CALIOP aerosol extinction profile retrievals usually rely on accurately specifying the relationship between aerosol extinction and backscattering (i.e. lidar ratio). Uncertainties in the assigned lidar ratios are typically the largest source of systematic error (~30-50%) in the CALIOP retrievals of aerosol extinction, backscatter, and aerosol optical depth. Alternatively, column aerosol optical depth (AOD) can be used to solve the lidar equation and obtain column-equivalent lidar ratios and retrieve aerosol extinction profiles from the CALIOP attenuated backscatter profiles. These derived lidar ratios correspond to the aerosols in the altitude range from 0-7 km. We derive column-equivalent aerosol lidar ratios and aerosol extinction profiles from CALIOP attenuated backscatter profiles constrained using co-located column AODs provided by several instruments/techniques: Synergized Optical Depth of Aerosols (SODA), Ocean-Derived Column Optical Depths (ODCOD), MODIS (dark target), MODIS (Multi-Angle Implementation of Atmospheric Correction-MAIAC), and PARASOL (Generalized Retrieval of Aerosol and Surface Properties-GRASP). These various retrievals of AOD and the column-average aerosol lidar ratios and aerosol extinction profiles derived from CALIOP using these AOD constraints are evaluated using the extensive record of coincident and co-located airborne HSRL measurements of AOD, aerosol lidar ratio, and aerosol extinction profiles acquired during more than 140 HSRL underflights of CALIPSO since 2006. The HSRL technique allows for the independent measurement of extinction and backscatter without the need for external constraints or assumptions regarding the lidar ratios. Initial comparisons with these coincident HSRL aerosol extinction profiles show that the CALIOP aerosol extinction profiles retrieved using these various AOD constraints are generally in better agreement with the HSRL measurements than aerosol extinction profiles from the operational techniques. The quality of agreement depends on the accuracy and magnitude of the AOD constraint. We present these comparisons of AOD, column aerosol lidar ratio, and aerosol extinction profiles for each of the AOD constraints described above.

lidar↗