Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optical Time Transfer for Bistatic SAR Spacecraft

A spacecraft-to-spacecraft optical time-transfer simulation has been developed as a tool for informing NASA’s Surface Deformation and Change (SDC) mission architecture. The SDC mission will combine radar images from multiple spacecraft to improve understanding of the Earth’s sea-level and landscape changes. Spacecraft must be precisely synchronized in order to create sharp radar images. Simulation of multiple spacecraft time-synchronizing via laser communication can inform technology choices of a mission by providing a picosecond-precision level estimate of clock error. This timing and ranging simulation has been combined with a radar system performance analysis pipeline. The simulated timing errors are used to predict performance of bistatic SAR systems in the presence of oscillator noise and time synchronization in accuracy. This analysis includes both analytic approximation equations from existing literature, and a numerical radar simulation to extract key system performance parameters like phase error and signal-to-noise ratio (SNR)degradation. Precision time-transfer techniques facilitate the accurate synchronization of clocks between any combination of terminals. Most time-transfer technology for comparing two clocks at different terminals use radio frequencies (RF) to measure the time delay between the sending and receiving of signals. Laser technology offers the capability to transmit high data rates with systems that are of smaller size and lower power than comparable RF systems. The clocks on independent spacecraft will have some phase and frequency errors between them that result in clock drift. The two clock models that are included in this bi-directional MATLAB simulation are a cesium-based Chip-Scale Atomic Clock (CSAC) and a rubidium-based Miniature Atomic Clock (MAC). The CSAC has flown as hardware for small satellite missions such as the University of Florida’s CHOMPTT mission. A study of example orbits, including that of NASA NASA-ISRO Synthetic Aperture Radar Mission (NISAR) mission, and lasing rates demonstrate the impact of flight configuration parameters on the synchronization error between two spacecraft. The MATLAB timing simulation uses a Runge-Kutta 4th-order method to propagate spacecraft orbits and computes the light-travel time estimate between them. The simulation outputs the estimated range and estimated clock error based on a user-defined spacecraft cluster configuration. The radar simulation and analytic approximations are applied to evaluate a potential future NASA bistatic SAR constellation architecture. In the proposed architecture, satellites follow each other in the same orbit at 800 km altitude, with a 210 km baseline. We also baseline the CSAC as an ultra stable oscillator, and use NASA’s NISAR for baseline radar system parameters to compute a clock-system introduced phase error of 5.6 degrees without synchronization by frequent time transfer. We build on this base case with a sensitivity analysis of radar performance over a proposed range of constellation and radar system parameters. With this analysis pipeline, we comment on which radar parameters should or should not be changed to minimize synchronization requirements. This analysis technique could be extended or modified to evaluate the timing requirements of other geometries for other future multistatic SAR missions, or other interferometric satellite missions.

Surface Deformation and Change↗

Copernicus observations of C I and CO in diffuse interstellar clouds

Copernicus was used to observe absorption lines of C I in its ground state and excited fine structure levels and CO toward 29 stars. We use the C I data to infer densities and pressures within the observed clouds, and because our results are of higher precision than previous work, much more precise estimates of the physical conditions in clouds are obtained. In agreement with previous work, the interstellar thermal pressure appears to be variable, with most clouds having values of p/k between 1000/cu cm K and 10,000/cu cm K, but there are some clouds with p/k as high as 100,000/cu cm K. Our results are consistent with the view that the interstellar thermal pressure is so variable that the gas undergoes continuous dynamic evolution. Our observations provide useful constraints on the physical processes on the surfaces of grains. In particular, we find that grains are efficient catalysts of interstellar H2 in the sense that at least half of the hydrogen atoms that strike grains come off as part of H2. Results place strong constraints on models for the formation and destruction of interstellar CO. In many clouds, an order of magnitude less CO than predicted in some models was found.

Jenkins, E. B.↗

Diffusion in liquid state and solidification of binary system (M-7)

Diffusion is one of the most fundamental physical phenomena. It relates to the manufacturing of almost all materials. Therefore, the precise knowledge of diffusivities of relevant materials is necessary for the optimization of these processes. On the other hand, such knowledge is indispensable to understanding the diffusion mechanism and structure of liquid metal in the field of physical metallurgy. Many diffusion experiments on solid metal were undertaken and a lot of data were accumulated. But on liquid metals there are few measurements because of experimental difficulties, such as thermal convection, induced by very slight temperature gradients in the specimen. Under microgravity conditions, the movement of liquid metal due to density differences and thermal convection must be suppressed markedly. Therefore, the transportation process will be controlled only by the diffusion of constituent atoms. These conditions offer the optimum environments for the diffusion experiment. The experiments are briefly described. Diffusion couples are prepared by attaching end to end two rods of different pure metals using hot press equipment. These couples are inserted into a graphite crucible and then doubly enclosed by two silica ampoules, respectively. The specimen is inserted into a tantalum cartridge, which is welded in a vacuum using an electron-beam apparatus. These cartridges are charged in the continuous heating furnace in space and held at a given temperature for a predetermined time and then solidified. The concentration distribution of elements in these specimens will be measured along the rod axis by means of an electron probe microanalyzer. The counterdiffusivity of the liquid metal binary system is determined on the basis of the compensated concentration distribution profile for thermal contraction.

Dan, T.↗

Oxygen isotopes in deep sea spherules

The determination of the genetic relationships between the dust and small particles in the solar system, and the meteorites and larger bodies are examined. Oxygen isotopes proved useful in the identification of such relationships between one meteorite group and another. Of the various samples of submillimeter extraterrestrial particles available for laboratory study, only the deep sea spherules are abundant enough for precise oxygen isotope analysis using existing techniques. Complications arise in interpretation of the isotopic data, since these particles were melted during passage through the Earth's atmosphere, and have been in contact with seawater for prolonged periods. Spherules that were originally silicates are considered with the originally metallic ones to deduce their preterrestrial isotopic compositions. The type 1 spherules which enter the atmosphere as metallic particles, contain only atmospheric oxygen. The type S spherules contain a mixture of atmospheric oxygen and their original extraterrestrial oxygen. It is suggested that the Earth's mesosphere is strongly enriched in heavy isotopes of oxygen at altitudes near 90 km at which the iron particles are oxidized. Fractionation due to the combined diffusion of O atoms and O2 molecules may be responsible.

Mayeda, T. K.↗

Technology Demonstration Missions

Technology Demonstration Missions (TDM) is in its third year of execution, being initiated in 2010 and baselined in January of 2012. There are 11 projects that NASA Marshall Space Flight Center (MSFC) has contributed to or led: (1) Evolvable Cryogenics (eCryo): Cyrogenic Propellant Storage and Transfer Engineering Development Unit (EDU), a proof of manufacturability effort, used to enhance knowledge and technology related to handling cryogenic propellants, specifically liquid hydrogen. (2) Composites for Exploration Upper Stage (CEUS): Design, build, test, and address flight certification of a large composite shell suitable for the second stage of the Space Launch System (SLS). (3) Deep Space Atomic Clock (DSAC): Spaceflight to demo small, low-mass atomic clock that can provide unprecedented stability for deep space navigation. (4) Green Propellant Infusion Mission (GPIM): Demo of high-performance, green propellant propulsion system suitable for Evolved Expendable Launch Vehicle (EELV) Secondary Payload Adapter (ESPA)-class spacecraft. (5) Human Exploration Telerobotics (HET): Demonstrating how telerobotics, remote control of a variety of robotic systems, can take routine, highly repetitive, dangerous or long-duration tasks out of human hands. (6) Laser Communication Relay Demo (LCRD): Demo to advance optical communications technology toward infusion into deep space and near Earth operational systems, while growing the capabilities of industry sources. (7) Low Density Supersonic Decelerator (LDSD): Demo new supersonic inflatable decelerator and parachute technologies to enable Mars landings of larger payloads with greater precision at a wider range of altitudes. (8) Mars Science Laboratory (MSL) Entry Descent & Landing Instrumentation (MEDLI): Demo of embedded sensors embedded in the MSL heat shield, designed to record the heat and atmospheric pressure experienced during the spacecraft's high-speed, hot entry in the Martian atmosphere. (9) Solar Electric Propulsion (SEP): 50-kW class spacecraft that uses flexible blanket solar arrays for power generation and an electric propulsion system that delivers payload from low-Earth orbit to higher orbits. (10) Solar Sail Demonstration (SSD): Demo to validate sail deployment techniques for solar sails that are propelled by the pressure of sunlight. (11) Terrestrial HIAD Orbit Reentry (THOR): Demo of a 3.7-m Hypersonic Inflatable Aerodynamic Decelerator (HIAD) entry vehicle to test second generation aerothermal performance and modeling.

McDougal, John↗

Time maintenance system for the BMDO MSX spacecraft

The Johns Hopkins University Applied Physics Laboratory (APL) is responsible for designing and implementing a clock maintenance system for the Ballistic Missile Defense Organizations (BMDO) Midcourse Space Experiment (MSX) spacecraft. The MSX spacecraft has an on-board clock that will be used to control execution of time-dependent commands and to time tag all science and housekeeping data received from the spacecraft. MSX mission objectives have dictated that this spacecraft time, UTC(MSX), maintain a required accuracy with respect to UTC(USNO) of +/- 10 ms with a +/- 1 ms desired accuracy. APL's atomic time standards and the downlinked spacecraft time were used to develop a time maintenance system that will estimate the current MSX clock time offset during an APL pass and make estimates of the clock's drift and aging using the offset estimates from many passes. Using this information, the clock's accuracy will be maintained by uplinking periodic clock correction commands. The resulting time maintenance system is a combination of offset measurement, command/telemetry, and mission planning hardware and computing assets. All assets provide necessary inputs for deciding when corrections to the MSX spacecraft clock must be made to maintain its required accuracy without inhibiting other mission objectives. The MSX time maintenance system is described as a whole and the clock offset measurement subsystem, a unique combination of precision time maintenance and measurement hardware controlled by a Macintosh computer, is detailed. Simulations show that the system estimates the MSX clock offset to less than+/- 33 microseconds.

Hermes, Martin J.↗

Theoretical analysis of isotope effects on ozone formation in oxygen photochemistry

In situ measurements of stratospheric ozone and laboratory studies of ozone production in electric discharge through oxygen have shown previously that ozone containing heavy isotopes of oxygen (O-17, O-18) may be formed preferentially. In order to assess the relevance of thee latter experiment to the stratospheric measurements, detailed understanding of the effect of isotopic substitution on the O3 formation reaction O + O2 + M yields O3 + M and on the O atom exchange reaction O + O2 + O yields O2 + O is necessary. In this work, an estimate of the effect of isotopic substitution on the recombination rate is made by us of approximate dynamical theories and statistical mechanics. The results indicate the possibility of isotope effects on the O + O2 recombination rate of the order of several percent at stratospheric temperatures. In general, recombination reactions involving heavy (mass 49, 50) O3 formation are found to be slower than the reaction leading to normal (mass 48) O3 formation. The calculated isotope effects are sufficiently small that the uncertainties in the model input and the approximations in the dynamical theories will probably make the quantitative nature of these results subject to considerable uncertainty. This isotope effect should not be observable in the atmosphere given the precision of the current measurements but may be crucial in the understanding of the laboratory experiments, where observed enhancements are only of the order of several percent. Possible reasons for this discrepancy between the observed enhancement and predicted depletion are presented.

Kaye, J. A.↗

Contamination of optical surfaces in Earth orbit

Glass and glass ceramic samples exposed to the low earth orbit environment for approximately 5.5 years on the Long Duration Exposure Facility (LDEF) were found to display limited degradation in optical transmission. Commercial optical quality fused silica samples display decreases in transmission in the 200 to 400 nm wavelength region, and this degradation appears to be a consequence of surface contamination. The contamination, found only on internal surfaces of samples, was measured by medium energy backscattering spectrometry and found to be primarily carbon. Additional thin film contamination by a species with atomic mass near 64, which was present at the level of about 8 x 10 exp 14/sq. cm has not been identified. These observations are consistent with the interpretation that organic binders used in the black absorbing paint (Chem Glaze Z-306) inside the sample holding tray were concentrated in the vicinity of the samples and photolytically cracked by solar UV radiation. The resulting decomposition products were deposited on the interior sample surface and gave rise to the optical transmission loss. No detectable contamination was observed on the external or space exposed surface of the samples. No measurable damage was detected which could be attributed to the direct action of gamma or UV radiation on the glass samples. These results emphasize the need for special precautions in the preparation of spacecraft carrying precision optical components on long duration missions.

Donald L Kinser↗

The Influence of Redox Conditions on the Seismic Properties of Polycrystalline Olivine

Eight olivine specimens were fabricated by use of a solgel method and hot-pressing at 1200 degrees Centigrade and 300 megapascals (MPa) inside of welded Pt capsules. Each hot-pressed specimen was then recovered, precision ground, and wrapped in Pt, Ni or NiFe foil to vary oxygen fugacity (fO2) during the subsequent forced torsional oscillation measurements. Mechanical testing was conducted at 10 oscillation periods between 1 and 1000 seconds, at a confining pressure of 200 MPa, during a slow staged-cooling from a maximum temperature of 1200 degrees Centigrade down to room temperature. After mechanical testing, each specimen was axially sectioned and EBSD (Electron BackScatter Diffraction) was used for the determination of the representative grain size, and grain size distribution of each sample. In addition, each longitudinal section was mapped via FTIR (Fourier Transform Infrared Spectroscopy) to determine the spatial distribution and concentrations of chemically bound and molecular water. Amongst these eight specimens, chemically bound ‘water’ contents were observed to vary between 0 and 1150 atom parts per million (ppm) H/Si, and molecular water concentrations varied between 0 and 245 atom ppm H/Si. Our forced-oscillation results demonstrate that the measured magnitude of anelastic relaxation within the experimental ‘window’ of oscillation periods is unrelated to the water content. Rather, a relationship was observed between the magnitude of anelastic relaxation and the prevailing redox conditions, which is influenced by the choice of metal sleeving used during the mechanical test. Further, regardless of water content or metal sleeving, each specimen exhibits coupled variations in shear modulus and dissipation within the observational window, indicative of ‘high-temperature background’ behavior, that can be described by a Burgers-type model. During initial fitting of the Burgers models, the unrelaxed shear modulus at a reference temperature of 900°C (elastic unloading/reloading shear modulus G (sub UR)) and the temperature derivative of the unrelaxed shear modulus (dGU/dT), were treated as adjustable parameters. For all Fe-bearing olivine samples we observe deficits of G (sub UR) and increased values of dGU/dT, relative to the expected elastic (anharmonic) behavior for Fo (Forsterite content percentage) (sub 90) olivine. This behavior is indicative of anelastic relaxation occurring at shorter periods than observable within the ‘window’ of oscillation periods used in the mechanical test. Moving towards a comprehensive and seismologically applicable Burgers model, which includes this newly observed effect of redox conditions on anelastic relaxation, we will present our progress on reconciling truly anharmonic and elastic behavior of Fo (sub 90) olivine with our observed forced-oscillation data.

Cline, C. J., II↗

Design, Fabrication, and Testing of Emissive Probes to Determine the Plasma Potential of the Plumes of Various Electric Thrusters

A significant problem in the use of electric thrusters in spacecraft is the formation of low-energy ions in the thruster plume. Low-energy ions are formed in the plume via random collisions between high-velocity ions ejected from the thruster and slow-moving neutral atoms of propellant effusing from the engine. The sputtering of spacecraft materials due to interactions with low-energy ions may result in erosion or contamination of the spacecraft. The trajectory of these ions is determined primarily by the plasma potential of the plume. Thus, accurate characterization of the plasma potential is essential to predicting low-energy ion contamination. Emissive probes were utilized to determine the plasma potential. When the ion and electron currents to the probe are balanced, the potential of such probes float to the plasma potential. Two emissive probes were fabricated; one utilizing a DC power supply, another utilizing a rectified AC power source. Labview programs were written to coordinate and automate probe motion in the thruster plume. Employing handshaking interaction, these motion programs were synchronized to various data acquisition programs to ensure precision and accuracy of the measurements. Comparing these experimental values to values from theoretical models will allow for a more accurate prediction of low-energy ion interaction.

Chen, Erinna M.↗

The resonance lines of MG2 as diagnostics of the upper solar chromosphere

The resonance lines of singly ionized magnesium, the MgII h&k lines at about 280 nm, are two of the small number of lines in the solar spectrum that are optically thick in the chromospheric part of the solar atmosphere. Potentially these lines contain information on the initial temperature rise that occurs at the top of the photosphere. Unfortunately, few good observations of the lines exist due to their wavelength near 280 nm the ultraviolet. However, a fair number of observations (on the order of 200) are available from the data base of the UltraViolet Polarimeter and Spectrometer (UVSP) instrument that flew on board of NASA's Solar Maximum Mission (SMM) satellite. In addition, this data base contains a number of spectra that include the Mg I resonance line at (lambda)285.2nm, just longward of the h&k lines. The neutral magnesium line is not as strong as its ionic counterparts and samples slightly lower parts of the atmosphere. Its width is a sensitive diagnostic of the ionization balance between neutral and singly ionized magnesium, which determines the opacity scale (and formation height) of other diagnostically important MgI lines like the 457.1 nm intercombination line, the magnesium b lines and the infrared MgI emission lines near 12 microns. Analysis of the observed line profiles shows that it is necessary to include the effects of partial frequency redistribution (PRD) in the formation of the line as in the case of the h&k lines. This implies that the core of the line is very sensitive to the way scattering is treated in the modeling of the line, and in turn this allows us to separate the uncertain effects in the atomic data (viz. the Van der Waals broadening) from the uncertainties in the underlying atmospheric model. The main objective of this research was to compare observed spectra of the magnesium resonance lines against theoretical line profiles calculated from recent models of the solar atmosphere by Fontenla et al., hereafter called FAL. These models extend earlier solar models by Avrett et al. and provide yet a better match between observed and calculated spectra, in particular of the hydrogen Lyman line, by including the effects of ambipolar diffusion of hydrogen and helium in the mass and energy transport equations for the chromosphere-corona transition region. Although the transition region models can be built self-consistently (without additional observational input) once the proper boundary conditions are given at the top of the chromosphere, there are uncertainties in the models precisely because these boundary conditions are not well known. With the analysis of UVSP magnesium observations we strive to constrain these uncertainties.

Avrett, Eugene H.↗

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Thermodynamic properties and theoretical rocket performance of hydrogen to 100,000 K and 1.01325 x 10 to the 8th power N/sq m

The composition and thermodynamic properties were calculated for 100 to 110,000 K and 1.01325 x 10 to the 2nd power to 1.01325 x 10 to the 8th power N/sq m for chemical equilibrium in the Debye-Huckel and ideal-gas approximations. Quantities obtained were the concentrations of hydrogen atoms, protons, free electrons, hydrogen molecules, negative hydrogen ions, hydrogen diatomic molecular ions, and hydrogen triatomic molecular ions, and the enthalpy, entropy, average molecular weight, specific heat at constant pressure, density, and isentropic exponent. Electronically excited states of H and H2 were included. Choked, isentropic, one-dimensional nozzle flow with shifting chemical equilibrium was calculated to the Debye-Huckel and ideal-gas approximations for stagnation temperatures from 2500 to 100,000 K. The mass flow per unit throat area and the sonic flow factor were obtained. The pressure ratio, temperature, velocity, and ideal and vacuum specific impulses at the throat and for pressure ratios as low as 0.000001 downstream were found. For high temperatures at pressures approaching 1.01325 x 10 to the 8th power N/sq m, the ideal-gas approximation was found to be inadequate for calculations of composition, precise thermodynamic properties, and precise nozzle flow. The greatest discrepancy in nozzle flow occurred in the exit temperature, which was as much as 21 percent higher when the Debye-Huckel approximation was used.

Patch, R. W.↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Attitude stability of LDEF: Refinement of results from the silver pinhole camera

A measurement was previously described of the angular offset and attitude stability of the LDEF spacecraft using a simple pinhole camera device in the UAH experiment A0114. This device uses a silver surface to record the impact zone of atmospheric atomic oxygen passing through a small pinhole on the front surface of the satellite. The shape and size of this zone are well defined if the satellite velocity and gas temperature are known. The circular symmetry of the zone would be distorted by oscillation of the LDEF about its stable attitude, or by the effect of the co-rotation of the Earth's atmosphere for cases of satellites in nonequatorial orbits. The observed ellipticity of 1.05 with the major axis in the yaw direction is equivalent to an oscillation of + or - 0.2 deg about the stable attitude. The uncertainty in that measurement was estimated at about 0.1 deg. A refined analysis based on summing distributions of flux versus incidence angle for a large number of orbital positions, and including a co-rotating atmosphere, indicates that the combined distributions produce a result consistent with the measured exposed spot. It is suggested that, within the precision of the measurements, no actual oscillation of the LDEF is required to produce the results. Thus, the LDEF may have maintained a stable attitude to better than 0.1 deg, even under conditions of maximum aerodynamic perturbation when the silver oxygen record was made. This error is some two orders of magnitude lower than the predicted uncertainty in yaw oscillation and may indicate that the predict methodologies are too conservative.

Peters, P. N.↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

Components in interstellar molecular hydrogen

Results are reported for precise spectrophotometric measurements of the profiles of selected Lyman absorption lines produced by hydrogen molecules in various rotational levels along the line of sight to 13 stars which have shown some evidence for an increase in line width with increasing rotational quantum number (J). The line profiles were measured by multiple scans with the Copernicus satellite telescope. Based on analysis of the radial velocities, derivations of the column densities, and line-profile fitting, the following conclusions are made: (1) the increase in interstellar H2 line width with increasing J results from the presence of the most shortward component, which is relatively weak at low J but becomes more important at higher J; (2) the relative column densities found for the different J levels in each component may be fitted by a theoretical model in which rotational excitation is due to absorption of UV photons followed by radiative quadrupole spontaneous transitions or collisionally induced downward transitions between different J levels; (3) the atomic hydrogen density is between 300 and 1000 per cu cm in the most shortward component for each of three stars; (4) the approaching gas which produces each shortward component must be in the form of thin sheets; and (5) the sheets are the compressed gas behind a shock front moving through the interstellar medium.

Spitzer, L., Jr.↗